首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 140 毫秒
1.
HPLC/FLD法测定环境样品和食品中的苯并[a]芘   总被引:2,自引:1,他引:1  
样品用环已烷提取,提取液经硅镁型吸附剂-氧化铝柱净化后上机分析。色谱条件:Ultimate—C18柱,梯度洗脱,A相为水-乙腈(体积比40:60),B相为乙腈,荧光检测器(λex=350nm,λem=430nm)。在此色谱条件下,比较了Waters—PAHs(多环芳烃)柱与Ultimate—C18柱分离16种PAHs(多环芳烃)的异同,发现苯并[a]芘在Ultimate—C18柱上与其他多环芳烃同样有良好的分离效果。仪器检出限为2pg,方法检出限:气体样品0.1ng/m^3;水样0.2ng/L;食用油0.2μg/kg;海洋生物、陆地生物、家禽等生物样品为0.02μg/kg。  相似文献   

2.
建立了一种准确、快速、简便的烟丝中苯并[a]芘残留的超高效液相色谱-荧光(UPLC-FLR)测定方法.将烟末用环己烷超声提取40 min后过滤,滤液旋蒸浓缩至干再用甲醇-丙酮(V甲酵∶:V丙酮=10∶1)反萃后定容于容量瓶中,经0.2 μm的滤膜过滤后检测.荧光检测器激发波长365nm,发射波长410 nm.流动相为乙...  相似文献   

3.
建立了一种快速、新颖的高效液相色谱荧光检测法测定天然生育酚中痕量苯并[a]芘.天然生育酚样品经中性氧化铝柱色谱富集和净化后在 XDB-C,18反相柱上,采用水-乙腈(体积比20比80)为流动相进行分离,采用荧光检测器进行检测,其激发波长为 260 nm,发射波长为 408 nm.苯并[a]芘的定量下限为 0.50 ng·g-1.加标回收率大于 77.9%.分析了 3 个不同试样,测定结果的相对标准偏差在 3.0%~10.6%之间.  相似文献   

4.
用化学刻蚀法制作了不锈钢丝固相微萃取(SPME)纤维头,与高效液相色谱(HPLC)联用测定了环境水样中的痕量苯并[a]芘(B[a]p),考察了影响SPME的实验参数如萃取时间、解吸时间、萃取温度、搅拌速率和离子强度对萃取效率的影响,建立了测定水样中痕量B[a]p的SPME-HPLC方法。方法的线性范围0.10~4.00 ng/mL,相对标准偏差为7.5%(n=6),检出限为0.04 ng/mL,实际水样的加标回收率90.0%~105.0%。微萃取头机械强度高、寿命长、制作成本低,方法适用于测定环境水样中的痕量B[a]p。  相似文献   

5.
建立了固相萃取-高效液相色谱-荧光法检测方便面和烤肠中苯并[a]芘的方法。采用正己烷作为提取溶剂,经苯并[a]芘专用固相萃取柱HiCapt Benzo富集净化,高效液相色谱-荧光法对样品中苯并[a]芘进行分离分析。苯并[a]芘的质量浓度在0.5~20.0μg/kg范围内与色谱峰面积呈良好的线性关系,相关系数R2为0.9997。方便面和烤肠中苯并[a]芘的加标回收率分别为92.2%~98.3%和95.9%~97.9%,日内和日间相对标准偏差分别为3.34%~5.01%和2.11%~4.07%。与传统方法相比,该方法快速简单、有机溶剂消耗少,在油炸烟熏食品的苯并[a]芘分析中具有较大应用前景。  相似文献   

6.
工业废水中苯并[a]芘的高效液相色谱法测定   总被引:2,自引:0,他引:2  
工业废水中苯并[a]芘的高效液相色谱法测定汤加云高恩革(攀枝花钢铁(集团)公司劳动卫生防护研究所攀枝花617023)关键词工业废水苯并(a)芘高效液相色谱法萃取中图分类号O657.72苯并[a]芘简称Bap,又名3,4-苯并芘,是一种由五个苯环构成的...  相似文献   

7.
采用固相萃取方法,建立了草珊瑚中苯并[α]芘的高效液相色谱荧光测定方法。以正己烷为提取溶剂对草珊瑚样品进行提取,经中性氧化铝固相萃取柱净化样品后,用高效液相色谱荧光检测器检测,荧光检测器激发波长为370 nm,发射波长为425 nm,流动相为乙腈-水(85∶15),流速为1.0 m L/min。结果表明:苯并[α]芘在0~20 ng/m L浓度范围内线性关系良好,相关系数(r)为0.999 9,定量下限为0.36μg/kg,回收率为84.4%~101.9%,相对标准偏差(RSD)为1.6%~5.6%。该方法准确,灵敏度高,重复性好,适用于植物药材中苯并[α]芘残留的测定。  相似文献   

8.
建立了在线液相-气相二维色谱测定卷烟主流烟气中的苯并[a]芘方法.采用剑桥滤片捕集烟气粒相物,环己烷萃取,以D12-苯并[a]芘为内标,然后用在线液相-气相二维色谱测定:样品直接进样进入液相色谱,经微型硅胶柱分离,含苯并[a]芘的部位切割进人气相色谱,排干溶剂后启动气相色谱升温,经毛细管柱进行分离,用质谱检测.本方法将烟气苯并[a]芘测定中的硅胶柱层析和气相色谱-质谱分析在线连接起来,可不经样品前处理净化直接进样分析;而且每次进样可达40 μL,与常规气相色谱-质谱分析最大进样2.0 μ.L相比,分析灵敏度提高了20倍.方法线性范围达0.08~ 50 ng/L,相关系数为r2=0.999,回收率为94.2%~105.5%;检出限和定量限分别为0.09和0.30 ng/支,应用本方法对14个不同类型市售卷烟和2R4F标准烟进行了测定,结果与GB/T21130-2007测定结果相符合.  相似文献   

9.
大气漂尘中苯并[a]芘的简单同步荧光测定   总被引:2,自引:0,他引:2  
通过选择合适的能量差(Δ-υ=1 400 cm-1),建立了大气漂尘中苯并[a]芘的恒能量同步荧光分析法。苯并[a]芘在甲醇与十二烷基磺酸钠(SDS)溶液中均有良好的线性关系(R>0.999),检出限分别达到1.34 nmol/L与0.40 nmol/L。该法亦可应用于18种多环芳烃混合物中苯并[a]芘的鉴别。  相似文献   

10.
建立了集萃取与净化于一体的加速溶剂/固液固萃取(AS/SLSE)卷烟烟气中痕量苯并[a]芘(BaP)的样品前处理方法。卷烟烟气经捕集后,用AS/SLSE提取和净化,萃取液浓缩后进行色谱分析。优化了AS/SLSE吸附剂、萃取温度、吹扫体积、静态萃取时间及循环次数等条件。在优化条件下(5 g硅镁型吸附剂、萃取温度100℃、吹扫体积40%、静态萃取时间3 min循环2次,样品连续萃取3次),AS/SLSE-气相色谱/质谱法(GC/MS)分析卷烟烟气中苯并[a]芘方法的检出限为1.0μg/L,回收率为97.1%,相对标准偏差(RSD)为2.5%。方法成功用于卷烟烟气样品的分析,测定结果与国家标准推荐方法吻合。  相似文献   

11.
《Analytical letters》2012,45(14):2271-2279
Abstract

A simple and sensitive method was developed to simultaneously determine phenanthrene and benzo(a)pyrene in water samples using synchronous fluorescence spectroscopy with a 56-nm Δλ. The method was used to simultaneously determine both compounds in samples of spiked surface water. Analytical recoveries were 96.9–101.1% for phenanthrene and 95.8–103.5% for benzo(a)pyrene. Analytical results were checked for precision with 15 measurements for each compound. Relative standard deviations were 1.9% for phenanthrene and 2.9% for benzo(a)pyrene, which shows that the proposed method is quite precise.  相似文献   

12.
Abstract

We report the direct determination of two polycyclic aromatic hydrocarbons (PAH), Benzo(a)Pyrene [B(a)P] and Pyrene (Pyr), in solid environmental samples, i.e. a marine sediment and scrapings from the interior walls of a steel foundry, by the supersonic jet/laser induced fluorescence technique. We have found limits of detection (LOD) for these samples of 900ng (1.8ppm) for B(a)P and 200ng (0.4ppm) for Pyr. The LOD's for prepared solutions were 100 ng for B(a)P and 40 ng for Pyr. In validating the procedure we have also analyzed a standard mixture of PAH. The results of our analyses of the solid environmental samples agree well with those obtained by chromatography in other laboratories. We have found evidence of incomplete recovery of PAH from soil sediments by a prolonged low temperature Soxhlet extraction using methylene chloride.  相似文献   

13.
A rapid and simple method was optimized and validated for the separation and quantification of anthracene and benzo(a)pyrene, two of the most toxic polycyclic aromatic hydrocarbons, at ultratrace levels in aqueous samples by direct injection. The determination of anthracene and benzo(a)pyrene was performed by reverse-phase high-performance liquid chromatography (HPLC) with fluorescence detection. A fractional factorial matrix and a Box–Behnken design were chosen for screening and optimization purposes, respectively. The optimized parameters that significantly influenced the system were the flow rate (1?mL?min?1), mobile-phase strength (90% acetonitrile:10% deionized water), column temperature (35°C), and excitation wavelength (254 and 267?nm for anthracene and benzo(a)pyrene, respectively). The injection volume and emission wavelength were fixed at 100?µL and 416?nm, respectively. The quantification limits were 75?ng?L?1 for anthracene and 30?ng?L?1 for benzo(a)pyrene. The relative standard deviations for the recovery and intra and interday precision values were lower than 20%. The method allows the analysis of aqueous samples with a good resolution for anthracene and benzo(a)pyrene below values permitted by the recently developed European Directive 2013 Directive. 2013. Directive 2013/39/EU of the European parliament and of the council of 12 August 2013 amending directives 2000/60/EC and 2008/105/EC as regards priority substances in the field of water policy. Official Journal of the European Union L 226:117. [Google Scholar]/39/EU for inland surface waters. In addition, this work provides guidelines for the simultaneous optimization of several parameters by experimental design.  相似文献   

14.
采用高效液相色谱-荧光检测法测定多环芳烃化合物蒽和荧蒽。在Shim-packCLC-phenyl柱上,以50%的乙腈水溶液作流动相,12min内实现了两组分的同时分离测定。线性范围为0~80μg/mL,检测限低于50ng/mL,相对标准偏差小于1%。  相似文献   

15.
高效液相色谱-蒸发光散射检测器测定食品中胆固醇含量   总被引:1,自引:0,他引:1  
建立了可满足各类食品(包括动物性食品、动植物混合食品)中胆固醇的HPLC—ELSD快速测定方法。样品经50%(w)KQH直接皂化和石油醚萃取后进行色谱分析。色i普柱为ODS柱,流动相为乙醇和乙脯,通过优化梯度洗脱条件,在20min内实现了胆固醇与干扰物质(如植物甾醇)的有效分离,分离度月大于1.5。胆固醇色谱峰面积的自然对数与浓度的自然对数呈良好的线性关系(r〉0.9996),检出限(LOD)为0.20μg(S/N=3),定量下限(LOQ)为0.56μg(S/N=10),回收率为93%-96%(n=6),重复性RSD〈3.0%(n=6)。  相似文献   

16.
植物油中苯并芘含量测定研究   总被引:2,自引:0,他引:2  
为建立固相萃取-液相色谱法测定植物油中苯并芘的检验方法,将植物油中的苯并芘用中性氧化铝固相萃取小柱萃取和净化后用反相色谱柱分离,荧光检测器进行了检测。结果表明,苯并芘质量浓度在0.001~0.1μg/mL范围内与峰面积具有良好的线性关系,相关系数r=0.9999,检测限为0.4μg/kg,回收率在88.1%~94.2%之间,RSD为2.42%,操作简便,对样液的净化效果好,结果准确可靠。  相似文献   

17.
苯并[a]芘是一种强致癌物质,它是有机化合物在高温条件下发生聚合反应产生的,主要在垃圾焚烧、高温炼油等过程中产生。其一旦产生就很难分解,因此危害较大。无公害食品植物油的理化指标中规定苯并[a]芘的含量要低于10μg/kg。本文采用基质固相分散萃取技术处理植物油样品,减少了有机溶剂的用量,缩短了分析时间,提高了分析效率。处理后的样品经高效液相色谱法(HPLC)的快速测定,所得结果完全能满足食品检验的需要。  相似文献   

18.
应用反相高效液相色谱-荧光检测技术,发展了人血清中14种胆汁酸分析的新方法,流动相中加入β环糊精作为添加剂,等度冲洗,一次分析可在60min内完成,且可以达到基线分离。由于胆汁酸的紫外吸收弱,采用4-溴甲基-7-甲氧基香豆素作为荧光试剂衍生。激发波长320nm,发射波长380nm。血清样品经预处理,回收率介于660%~916%之间。在0025~15mg/L质量浓度范围,色谱峰面积对浓度作线性回归分析,回归系数介于09908~09986之间。方法快速、简单、灵敏度高。  相似文献   

19.
建立了测定烤肉中苯并(α)芘含量的高效液相色谱法。采用CNW~Athena C_(18)色谱柱(250 mm×4.6 mm,5μm),流动相为甲醇–水(90∶10),流量为1.0 m L/min,柱温为35℃,进样体积为10μL,荧光检测器激发波长为365 nm,发射波长为410 nm,以色谱峰面积标准曲线法定量。苯并(α)芘的质量浓度在0~0.2μg/m L范围内与色谱峰面积呈良好的线性关系,相关系数为0.999 5,检出限为0.07μg/kg,加标回收率为91.3%~92.6%,测定结果的相对标准偏差为1.21%~1.40%(n=5)。该法样品预处理简便,检测时间短,灵敏度高,适用于烤肉中苯并(α)芘的含量测定。  相似文献   

20.
苯并[a]芘是一种强致癌物质,它是有机化合物在高温条件下发生聚合反应产生的,主要在垃圾焚烧、高温炼油等过程中产生。其一旦产生就很难分解,因此危害较大。无公害食品植物油的理化指标中规定苯并[a]芘的含量要低于10μg/kg。本文采用基质固相分散萃取技术处理植物油样品,减少了有机溶剂的用量,缩短了分析时间,提高了分析效率。处理后的样品经高效液相色谱法(HPLC)的快速测定,所得结果完全能满足食品检验的需要。1实验部分1.1仪器与试剂W a ters A lliance2695高效液相色谱仪,配四元泵溶剂淋洗系统、自动进样系统、2475荧光检测器。SUPE…  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号