首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Xu F  Jabasini M  Liu S  Baba Y 《The Analyst》2003,128(6):589-592
On a polymethylmethacrylate (PMMA) microchip, double-stranded DNA fragments with a wide size range from 50 bp to 20 kbp were separated by two polymer solutions. One was a hydroxypropylmethylcellulose-4000 (HPMC-4000) solution of 1.3% (w/v) to separate fragments below 590 bp, and another was a mixed four molecular weight poly(ethylene oxide) solution at a total concentration of 0.1% to separate fragments above 520 bp. The widths at half height (wh) of the fragments had a good relationship with their migration times (tR) in both polymer solutions. Such a relationship was suitable for obtaining the wh values of unresolved peaks, calculating the resolution of two adjacent fragments, and optimizing microchip separation matrices. Based on the relativity, a low viscosity medium containing 2% HPMC-50 and 8% glucose was optimized for high-performance separation of a phiX174 HaeIII restriction fragment digest.  相似文献   

2.
Chiou SH  Huang MF  Chang HT 《Electrophoresis》2004,25(14):2186-2192
The separation of DNA by capillary electrophoresis using poly(ethylene oxide) (PEO) containing gold nanoparticles (GNPs) is presented. The impacts of PEO, GNPs, ethidium bromide (EtBr), and pH on the separation of double-stranded DNA have been carefully explored. Using a capillary dynamically coated with 5.0% poly(vinylpyrrolidone) and filled with 0.2% PEO containing 0.3 x GNPs (the viscosity less than 15 cP), we have demonstrated the separation of DNA markers V and VI within 5 min at pH 8.0 and 9.0. In terms of resolution and reproducibility, GNPs have a greater impact on the separation of DNA at pH 9.0. Resolution improvements for large DNA fragments (> 300 base pairs, bp) are greater than those for small ones in the presence of GNPs. It is important to point out that reproducibility is excellent (relative standard deviations for the migration times less than 0.5%) and thus no further dynamic coating is required in at least 20 consecutive runs in the presence of GNPs. Using 0.2% PEO (pH 9.0) containing 0.3 x GNPs, the separation of DNA fragments ranging in size from 21 to 23,130 bp was accomplished in 7 min. The results presented in this study show the advantage of PEO containing GNPs for DNA separation, including rapidity, high resolving power, excellent reproducibility, and ease of filling capillaries.  相似文献   

3.
Liu T  Liang D  Song L  Nace VM  Chu B 《Electrophoresis》2001,22(3):449-458
A mixture of two polyoxybutylene-polyoxyethylene-polyoxybutylene (BEB) triblock copolymers (B6E46B6 and B10E271B10, respectively) was used as a new separation medium for separating double-stranded DNA (dsDNA) fragments by capillary electrophoresis (CE). The two block copolymer mixtures were designed to form mixed flower-like micelles in dilute solution and a homogeneous gel-like open-network with hydrophobic clusters as cross-linking points at higher polymer concentrations. Being a polyoxyalkylene block copolymer gel, the separation medium has some special advantages, including the temperature-dependent sol-gel transition that makes sample injection easy, and the self-coating of the inner capillary wall that makes experimental procedures simple and reproducible. Furthermore, it can shorten the elution time and further improve the separation resolution, especially for small dsDNA fragments, when compared with EPE-type separation media, e.g., F127 (E99P69E99, with P being polyoxypropylene) block copolymer gels formed by the closed packing of spherical micelles. Single base pair resolution can be achieved by using the new separation medium for dsDNA fragments up to over 100 base pairs.  相似文献   

4.
The impact of gold nanoparticles (GNPs) on the microchip electrophoretic separation of double-stranded (ds) DNA using poly(ethylene oxide) (PEO) is described. Coating of the 75-microm separation channel on a poly(methyl methacrylate) (PMMA) plate in sequence with poly(vinyl pyrrolidone), PEO, and 13-nm GNPs is effective to improve reproducibility and resolution. In this study, we have also found that adding 13-nm GNPs to 1.5% PEO is extremely important to achieve high resolution and reproducibility for DNA separation. In terms of the stability of the GNPs, 100 mM glycine-citrate buffer at pH 9.2 is a good buffer system for preparing 1.5% PEO. The separation of DNA markers V and VI ranging in size from 8 to 2176 base pairs has been demonstrated using the three-layer-coated PMMA microdevice filled with 1.5% PEO containing the GNPs. Using these conditions, the analysis of the polymerase chain reaction products of UGT1A7 was complete in 7 min, with the relative standard deviation values of the peak heights and migration times less than 2.3% and 2.0%, respectively. In conjunction with stepwise changes of the concentrations of ethidium bromide (0.5 and 5 microg/ml), this method allows improved resolution and sensitivity for DNA markers V and VI.  相似文献   

5.
Song L  Liu T  Liang D  Fang D  Chu B 《Electrophoresis》2001,22(17):3688-3698
Mixtures of two polymers with totally different chemical structures, polyacrylamide and polyvinylpyrrolidone (PVP) have been successfully used for double-stranded DNA separation. By polymerization of acrylamide in a matrix of PVP solution, the incompatibility of these two polymers was suppressed. Laser light scattering (LLS) studies showed that highly entangled interpenetrating networks were formed in the solution. Further systematic investigation showed that double-stranded DNA separation was very good in these interpenetrating networks. With a concentration combination of as low as 2% w/v PVP (weight-average molecular mass Mr = 1 x 10(6) g/mol) + 1% w/v polyacrylamide (Mr = 4 x 10(5) g/mol), the 22 fragments in pBR322/HaeIII DNA, including the doublet of 123/124 bp, have been successfully separated within 6.5 min. Under the same separation conditions, similar resolution could only be achieved by using polyacrylamide (Mr = 4 x 10(5) g/mol) with concentrations higher than 6% w/v and could not be achieved by using only PVP (Mr = 1 x 10(6) g/mol) with a concentration as high as 15% w/v. It is noted that the interpenetrating network formed by 2% PVP and 1% polyacrylamide has a very low viscosity and can dynamically coat the inner wall of a fused-silica capillary. The separation reached an efficiency of more than 10(7) theoretical plate numbers/m and a reproducibility of less than 1% relative standard deviation of migration time in a total of seven runs. The interpenetrating network could stabilize polymer chain entanglements. Consequently, the separation speed was increased while retaining resolution.  相似文献   

6.
Huang MF  Huang CC  Chang HT 《Electrophoresis》2003,24(17):2896-2902
The analysis of double-stranded (ds) DNA fragments by capillary electrophoresis (CE) using poly(ethylene oxide) (PEO) solution containing gold nanoparticles (GNPs) is presented, focusing on evaluating size dependence of the GNPs and PEO on resolution and speed. To prevent the interaction of the capillary wall with DNA, the capillary was dynamically coated with polyvinylpyrrolidone. Using different PEO solutions containing GNPs ranging in diameter from 3.5 to 56 nm, we have achieved reproducible, rapid, and high-resolution DNA separations. The results indicate that the sizes of PEO and GNPs as well as the concentration of PEO affect resolution. The separation of DNA ranging in size from 8 to 2176 base pairs (bp) was accomplished in 5 min using 0.2% PEO (8 MDa) containing 56 nm GNPs. We have also demonstrated the separations of the DNA fragments ranging from 5 to 40 kbp using 0.05% PEO (2 MDa) containing 13 nm GNPs or 0.05% PEO (4 MDa) containing 32 nm GNPs. With very low viscosity (< 15 cP), automatic replacement of the sieving matrices is easy, indicating a great potential for high-throughput DNA analysis using capillary array electrophoresis systems.  相似文献   

7.
Liang D  Chu B 《Electrophoresis》2002,23(16):2602-2609
Effects of concentration gradient on double-stranded DNA (dsDNA) separation by capillary electrophoresis are presented. By using a concentration gradient in the range between 0.8% and 3.2% for poly(N,N-dimethylacrylamide) (PDMA), the presence of a mesh-size gradient in the capillary could enhance the separation of larger size DNA fragments, better than that based on a single uniform concentration over the same capillary length. A decrease in the column length could make the gradient effect more obvious. An optimal capillary length could be achieved by using a judicious combination of the concentration gradient and the concentration range, yielding a maximum resolution for the system. The standard deviation of the migration time measured for each DNA fragment was less than 5% in ten continuous runs, suggesting that the gradient formed inside the column was quite stable.  相似文献   

8.
Positive ion electrospray ionization mass spectra of 16 base-pair double-stranded (ds)DNA have been obtained with essentially no ions from single-stranded DNA present. Single-stranded DNA was minimized by: (1) careful choice of DNA sequences; (2) the use of a relatively high salt concentration (0.1 M ammonium acetate, pH 8.5), and, (3) a low desolvation temperature (40 degrees C). Similarly, ESI-MS complexes of dsDNA with cisplatin, daunomycin and distamycin were obtained that contained only negligible amounts of single-stranded DNA. The complexes with daunomycin and distamycin were more stable to strand separation in the gas phase than dsDNA alone. This is in agreement with solution studies and with other recent gas phase results. These data contrast with many earlier ESI-MS studies of dsDNA and DNA/drug complexes in which ions from ssDNA are also normally observed.  相似文献   

9.
Using the zwitterionic buffer N-2-hydroxyethylpiperazine-N'-2-ethanesulfonic acid (HEPES) in the presence of a high-molecular-mass hydroxypropylmethylcellulose (HPMC) as a sieving polymer and ethidium bromide double-stranded DNA (dsDNA) was separated in an untreated capillary. The HEPES buffer shielded the DNA against the capillary wall interaction and decreased the electroosmotic flow enabling a good separation of the DNA similar to that obtained in a commercially coated capillary. In addition to the low cost of the untreated capillary it can be washed after each run. Furthermore, stacking with hydrodynamic injection filling about half of the capillary volume is demonstrated.  相似文献   

10.
We describe a highly efficient method for reversible photocircularization of oligonucleotide (ODN) on a double-stranded DNA template: 5-carboxyvinyl-2'-deoxyuridine-containing ODN was reversibly circularized around the target sequence of the double-stranded plasmid DNA resulting in formation of a catenated plasmid.  相似文献   

11.
A novel molecular tool for double-stranded (ds) DNA detection using synthetic peptide is described. The peptide was designed based on the DNA binding domain of the lambda phage CRO repressor (CRO). The designed peptides contain helix-turn-helix (HTH), which is DNA binding motif. A cyclic peptide and a mutant peptide based on CRO were also designed, and the resulting affinity for dsDNA was increased. Furthermore, native amino acids of the peptide were replaced with arginine to increase the affinity for dsDNA. The affinity of these peptides for DNA binding was assessed by surface plasmon resonance (SPR) technique.  相似文献   

12.
Wang Y  Liang D  Hao J  Fang D  Chu B 《Electrophoresis》2002,23(10):1460-1466
A noncross-linked interpenetrating polymer network (IPN), consisting of poly(N,N-dimethylacrylamide) (PDMA) and polyvinylpyrrolidone (PVP, weight-average molecular weight M(w) = 1 x 10(6) g/mol) was synthesized by polymerizing N,N-dimethylacrylamide (DMA) monomers directly in PVP buffer solution and tested as a separation medium for double-stranded (ds)DNA analysis without further purification. Due to the incompatibility of PVP and PDMA, a simple solution mixture could incur a microphase separation and showed poor performance on dsDNA separation. However, a dramatic improvement was achieved by the formation of an IPN. We attributed the high sieving ability of IPN as due to an increase in the number of entanglements by the more extended polymer chains. Apparent viscosity studies showed that the IPN had a much higher viscosity than the simple mixture containing the same amount of PDMA and PVP. In 1 x Tris-borate-EDTA (TBE) buffer, the concentration ratio of PDMA and PVP had a great effect on the DNA separation. At optimal conditions, the 22 fragments in pBR322/HaeIII DNA were successfully separated within 15 min, with a resolution of better than 1.0 for 123/124 bp.  相似文献   

13.
The adsorption of DNA on surfaces is a widespread procedure and is a common way for fabrication of biosensors, DNA chips, and nanoelectronic devices. Although the biologically relevant and prevailing in vivo structure of DNA is its double-stranded (dsDNA) conformation, the characterization of DNA on surfaces has mainly focused on single-stranded DNA (ssDNA). Studying the structure of dsDNA on surfaces is of invaluable importance to microarray performance since their effectiveness relies on the ability of two DNA molecules to hybridize and remain stable. In addition, many of the enzymatic transactions performed on DNA require dsDNA, rather than ssDNA, as a substrate. However, it is not established that adsorbed dsDNA remains in its structure and does not denature. Here, two methodologies have been developed for distinguishing between surface-adsorbed single- and double-stranded DNA. We demonstrate that, upon formation of a dense monolayer, the nonthiolated strand comprising the dsDNA is released and the monolayer consists of mostly ssDNA. The fraction of dsDNA within the ssDNA monolayer depends on the length of the oligomers. A likely mechanism leading to this rearrangement is discussed.  相似文献   

14.
A polymer solution, formed by mixing two polyoxybutylene-polyoxyethylene-polyoxybutylene (BEB) triblock copolymers (B10E270B10 and B6E46B6), was tested as a new separation medium for double-stranded DNA separation in capillary electrophoresis. The mixture of B10E270B10 and B6E46B6 has a viscosity-adjustable property and a dynamic coating ability, which makes the medium very easy to handle. The performance of the mixture on the DNA separation is greatly affected by the mass ratio of the two constituents. There is a minimum amount of concentration for B10E270B10, below which the medium will lose its performance. The addition of B6E46B6 increases both the selectivity and the separation efficiency. The optimal concentration, with 3% (w/v) B10E270B10 and 5% (w/v) B6E46B6, is determined with the consideration of both speed and resolution. A resolution of 1.3 was achieved on the separation of 123/124 base pairs in the pBR322/HaeIII digest within 20 min by using a 10 cm column of 75 microm I.D., demonstrating the potential use of mixtures of amphiphilic block copolymers as an effective DNA separation medium.  相似文献   

15.
We developed a method for the analysis of multiplexed double-stranded DNA (dsDNA) samples complexed to various intercalating dyes using entangled polymer solution. A commercial single-column capillary electrophoresis (CE) instrument with diode array detection was used for multiplexed detection of DNA samples by addition of intercalating fluorescent molecules. A Phi X174HinfI and a pGEM DNA ladder (1 mg/mL) were used for the electrophoretic separation of dsDNA fragments ranging in size from 24 to 726 and 36 to 2645 bp, respectively. The results suggested that simultaneous electrophoretic separation of different DNA ladders multiplexed with different dyes could be performed in the same capillary yielding fast DNA sizing separations. CE analysis, which is often overpowered by slab gel in sample throughput, could now overcome this disadvantage by allowing multiplexed sample analysis in a fraction of the time needed for slab gel analysis. The separation efficiency of stained DNA molecules with both dyes were dramatically improved with buffers containing a large cation such as tetrapentylammonium ion (Npe(4) (+)) as the only cation in the buffer.  相似文献   

16.
Cross-linking of polyelectrolytes such as DNA gives gels that are osmotically highly swollen but contract upon addition of electrolytes and, in particular, upon association of oppositely charged cosolutes with the polyelectrolyte chain. The deswelling behavior of cross-linked DNA gels thus reflects the DNA-cosolute interactions and provides a basis for the development of responsive DNA formulations. Gels of both single- and double-stranded DNA have interesting applications, and a comparison between them provides the basis for understanding mechanisms. Denaturation of cross-linked ds-DNA gels was induced by heating them above the melting temperature and then cooling. This process, studied by fluorescence using ethidium bromide, appeared to be reversible when a heating/cooling cycle was performed. The swelling behavior upon addition of different cosolutes, such as metal ions, polyamines, charged proteins, and surfactants, was investigated for different DNA gel samples, including long and short ds-DNA and long and short ss-DNA. The DNA molecular weight was found to have only a slight effect on the deswelling curves, whereas conformation exhibited a pronounced effect. In general, single-stranded DNA gels exhibited a larger collapse in the presence of cations than did double-stranded DNA. This difference was more pronounced with surfactants than with the other cosolutes investigated. The difference between double- and single-stranded DNA was attributed to differences in linear charge density, chain flexibility, and hydrophobicity. For surfactants with different chain lengths, the swelling behavior displayed by ss-DNA can be interpreted in terms of an interplay between hydrophobic and electrostatic interactions, the latter being influenced by polymer flexibility. Increasing hydrophobicity of the network leads to a decreased critical aggregation concentration (cac) for the surfactant/gel complex, as a result of the strengthened hydrophobic attractive force between the surfactant and the gel chain. The swelling of DNA gels appears to be reversible and to be independent of DNA conformation. Surfactant-induced deswelling of DNA gels under some conditions appears to be quite homogeneous, whereas under other conditions, there is a separation into a collapsed region in the outer parts of the gel sample and an inside swollen part. Such "skin" formation is quite different for ss- and ds-DNA, with ss-DNA giving more pronounced skin formation over a wider range of binding ratio, beta. For example, no macroscopic separation into collapsed and swollen regions was observed at intermediate degrees of binding for ds-DNA gels, whereas a dense surfactant-rich surface phase (skin) was found to coexist with a swollen core network for ss-DNA gels with beta>0.5. One explanation for this difference is the large deformation energy required for the compression of the very stiff ds-DNA chains.  相似文献   

17.
L Song  D Fang  R K Kobos  S J Pace  B Chu 《Electrophoresis》1999,20(14):2847-2855
The separation of double-stranded DNA (dsDNA) fragments in polymethylmethacrylate (PMMA) capillary electrophoresis (CE) chips by using E99P69E99 as a separation medium has been demonstrated. The PMMA CE chips were simply manufactured by micromachining and adhesive tape sealing. To make the separation channel compatible with the separation medium, a dynamic nonionic surfactant coating procedure was developed, which made the plastic separation channel sufficiently hydrophilic to allow the separation medium to fill the channel by capillary action. Subsequent separation of DNA fragments was successful with a separation efficiency of the order of 10(4) theoretical plates over an effective separation distance of 1.5 cm. By using an applied electric field strength of 200 V/cm, the separation of low DNA mass ladder was completed within 5 min. The simple coating procedure, together with the self-assembled viscosity-adjustable separation medium, should be useful to meet some of the essential requirements for developing single-use disposable CE chips. Coating the channels with polymer blends of PMMA and the separation medium also showed promise.  相似文献   

18.
We have evaluated double-stranded DNA separations in microfluidic devices which were designed to couple a sample preconcentration step based on isotachophoresis (ITP) with a zone electrophoretic (ZE) separation step as a method to increase the concentration limit of detection in microfluidic devices. Developed at ACLARA BioSciences, these LabCard trade mark devices are plastic 32 channel chips, designed with a long sample injection channel segment to increase the sample loading. These chips were designed to allow stacking of the sample into a narrow band using discontinuous ITP buffers, and subsequent separation in the ZE mode in sieving polymer solutions. Compared to chip ZE, the sensitivity was increased by 40-fold and we showed baseline resolution of all fragments in the PhiX174/HaeIII DNA digest. The total analysis time was 3 min/sample, or less than 100 min per LabCard device. The resolution for multiplexed PCR samples was the same as obtained in chip ZE. The limit of detection was 9 fg/microL of DNA in 0.1xpolymerase chain reaction (PCR) buffers using confocal fluorescence detection following 488 nm laser excitation with thiazole orange as the fluorescent intercalating dye.  相似文献   

19.
A probe-regulated simultaneous separation (PRESS) using capillary electrophoresis (CE) was developed for separating single-stranded (ss) DNAs. We synthesized two DNA conjugate probes, -(5'-TGTGTGTGT-3')p-AAm(q)- and -(5'-GCCACCAGC-3')m-AAm(n)-, by copolymerizing 5'-methacryloyl-modified ssDNA with acrylamide (AAm), and characterized them in detail. The two probes showed lower electrophoretic mobilities than 5'-methacryloyl-modified ssDNAs. Furthermore, -(5'-TGTGTGTGT-3')p-AAm(q)- showed slightly faster electrophoretic mobility toward the anode than -(5'-GCCACCAGC-3')m-AAm(n)- due to its higher molar fraction of negatively-charged ssDNA. We successfully separated target ssDNAs having the same chain length by using two ssDNA conjugate probes that showed different electrophoretic mobilities, although the separation of these ssDNAs was difficult in conventional capillary electrophoresis systems.  相似文献   

20.
DNA fragments have been analyzed by matrix-assisted laser desorption ionization (MALDI) and electrospray mass spectrometry. In many cases, only the single-stranded oligonucleotides have been detected. Recently, spectra of intact double-stranded DNA have been obtained in both electrospray and massive cluster impact ionization. We show here the first MALDI spectra of intact double-stranded DNA (EcoR1 adaptor 12/16) that is clearly not due to nonspecific dimer formation. 6-Aza-2-thiothymine was used as the matrix in the presence of ammonium citrate. Via the same procedure but with other matrices commonly employed for oligonucleotide analysis, the intact DNA duplex was not detected. No sign of the homodimer of either of the single strands is observed. Although the spectrum also shows peaks attributable to each of the single strands, these are demonstrated to arise from the DNA solution and not the sample preparation or desorption process.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号