首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Fluorescence and terbium-sensitised luminescence properties of new quinolone garenoxacin have been studied. The fluorimetric method allows the determination of 0.060-0.600 μg ml−1 of garenoxacin in aqueous solution containing HCl/KCl buffer (pH 1.5) with λexc=282 nm and λem=421 nm. Micellar-enhanced fluorescence was also studied, leading to a higher than 400% increase in analytical signal in presence of 12 mM sodium dodecyl sulphate (SDS), allowing the determination of 0.020-0.750 μg ml−1 of garenoxacin. The terbium-sensitised luminescence method allows the determination of 0.100-1.500 μg ml−1 of garenoxacin in 12 mM SDS solution containing 0.08 M acetic acid/sodium acetate buffer (pH 4.1) and 7.5 mM Na2SO3 (chemical deoxygenation agent), with λexc=281 nm and λem=546 nm. Relative standard deviation (R.S.D.) values for the three methods were in the range 1.0-2.0%. The proposed procedures have been applied to the determination of garenoxacin in spiked human urine and serum.  相似文献   

2.
Biswas S  Chowdhury B  Ray BC 《Talanta》2004,64(2):308-312
A highly sensitive and virtually specific method has been developed for the trace and ultra trace 5 ng ml−1-1 μg ml−1 fluorimetric analysis of nitrite. The method is based on the quenching action of nitrite on the native fluorescence of murexide (ammonium purpurate) [λex=349.0 nm, λem=444.5 nm] in the acid range of 0.045-0.315 (M) H2SO4. The method is very precise and accurate (S.D.=±0.4877 and R.S.D.=0.4878% for the determination of 0.1 μg ml−1 of nitrite in 11 replicates). Relatively large excesses of over 35 cations and anions do not interfere. The proposed technique has been successfully applied for the determination of nitrite and nitrate in ground water, surface water and sea water, nitrite in soil and nitrate in forensic samples. The method has also been extended for the analysis of NOx in air.  相似文献   

3.
A new, simple and sensitive spectrofluorimetric method for the determination of salicylic acid (λex = 315 nm, λem = 408 nm) using As(III) as a sensitizing reagent has been investigated by measuring the increase of fluorescence intensity of salicylic acid due to the complexation of As(III)-salicylic acid in presence of sodium dodecyl sulfate (SDS) 10−3 M. Under optimum conditions, a significant relationship was obtained between the fluorescence intensity and salicylic acid concentration. A linear calibration curve was obtained in the range 13.8-13812 μg l−1 with product-moment correlation coefficient (R) 0.99985 and detection limit 4.2 μg l−1. The R.S.D. is 2.35% (n = 5).The method was applied successfully to the determination of salicylic acid in human serum.  相似文献   

4.
The screen-printed four-electrode system was used as the amperometric transducer for determination of phenols and pesticides using immobilised tyrosinase, peroxidase, acetylcholinesterase and butyrylcholinesterase. Acetylthiocholine chloride was chosen as substrate for cholinesterases to measure inhibition by pesticides, hydrogen peroxide served as co-substrate for peroxidase to measure phenols. The compatibility of hydrolases and oxidoreductases working in the same array was studied. The detection of p-cresol, catechol and phenol as well as of pesticides including carbaryl, heptenophos and fenitrothion was carried out in flow-through and steady state arrangements. In addition, the effects of heavy metals (Cu2+, Cd2+, Fe3+), fluoride (NaF), benzene and dimethylsulphoxide on cholinesterase activities were evaluated. It was demonstrated that electrodes modified with hydrolases and oxidoreductases can function in the same array.The achieved R.S.D. values obtained for the flow system were below 4% for the same sensor and less than 10% within a group of five sensors. For the steady state system, R.S.D.s were approximately twice higher. One assay was completed in less than 6 min. The limit of detection for catechol using tyrosinase was equal to 0.35 and 1.7 μM in the flow and steady state systems, respectively. On the contrary, lower limits of detection for pesticides were achieved in the steady state system—carbaryl 26 nM, heptenophos 14 nM and fenitrothion 0.58 μM.  相似文献   

5.
《Analytica chimica acta》2003,493(1):35-45
A novel, versatile and sensitive continuous-flow on-line solid phase fluorescence based system is proposed for the simultaneous determination of benomyl and carbendazim. The continuous-flow system is based on the on-line preconcentration and resolution of the pesticides on a solid sensing zone, followed by the sequential measure of their native fluorescence, monitored at 235/306 and 293/398 nm (λexc/λem for carbendazim and benomyl, respectively), and later desorption of these analytes (from the flow-through cell filled with C18 silica gel) using aqueous methanol mixtures as carrier and eluent solutions.A double discrimination is used for the simultaneous monitoring of these analytes: (1) the usage of two pair of excitation/emision wavelengths, performed by the use of a multiwavelength fluorescence detection mode and (2) a temporary sequentiation in the arrival of the analytes to the sensing system by on-line separation due to the different kinetics showed by the analytes in the sorption-desorption process performed just in the solid support placed in the flow-through cell. Carbendazim is determined the first, because it shows a weaker retention in the C18 bonded phase silica beads, while benomyl is strongly fixed. Then, benomyl is conveniently eluted from the flow-through sensing zone and its native fluorescence signal is measured (at 398 nm). The sensor was calibrated for two different injection volumes: 400 and 2000 μl. Using a 2000 μl sample volume, the analytical signal showed linearity in the range 0.050-1.0 and 0.020-0.50 μg ml−1 with detection limits of 3.0 and 7.5 ng ml−1 for carbendazim and benomyl, respectively, and R.S.D. values smaller than 2% for both analytes. A recovery study was performed on four different spiked environmental water samples at concentration levels from 0.05 to 0.35 μg ml−1. The recovery percentage ranged from 97 to 104%, and from 98 to 104%, for benomyl and carbendazim, respectively.  相似文献   

6.
Agarwal S  Aggarwal SG  Singh P 《Talanta》2005,65(1):104-110
The present paper describes the extractive quantification of zinc-dithiocarbamate fungicides, i.e. ziram (zinc bis-dimethyldithiocarbamate) and zineb (zinc ethylene-1,2-bis-dithiocarbamate) in fog-water samples. The method is based on the releasing of equivalent amount of zinc from the fungicides and its subsequent determination by visible spectrophotometry or by flame-atomic absorption spectrometry (flame-AAS). For spectrophotometry, the sample contained up to 48 μg of ziram and 42 μg of zineb was first equilibrated with chloroform. The recovery results show that only ziram content was extracted into chloroform. Then, the sample was treated with NH4SCN and surfactants (i.e. CPC and TX-100) solutions, and extracted with toluene to remove interference of inorganic zinc and other metal ions, if present in the sample. The residue was further used for zineb determination. The chloroform extract and residue were then digested separately with nitric acid to release Zn(II), which were then analyzed spectrophotometerically with 4-(2-pyridylazo)-resorcinol in the micellar medium (TX-100) for the determination of ziram and zineb, respectively. The complex shows λmax at 495 nm. The molar absorptivity in terms of ziram/zineb was determined to be (8.05) × 104 L mole−1 cm−1. The detection limits for ziram and zineb were calculated to be 20 and 21 μg L−1 (with R.S.D. < 1.5%), respectively. Whereas, the optimum concentration ranges were 0.08-1.6 and 0.07-1.4 mg L−1, respectively. Alternatively, the Zn contents present in chloroform extract and in residue were directly analyzed using flame-AAS without undergoing the digestion procedure, and ziram and zineb were determined, respectively. The optimum concentration ranges were 0.9-4.8 and 0.8-4.3 mg L−1, while the detection limits were calculated to be 145 and 144 μg L−1, respectively with R.S.D. < 2.5%. The methods are free from interference of almost all ions [including Zn(II)] and other dithiocarbamate pesticides, which can commonly associate with ziram/zineb in fog-water.  相似文献   

7.
A simple method for the rapid and simultaneous analysis of dichlorvos (DDVP), malathion, carbaryl, and 2,4-dichlorophenoxy acetic acid (2,4-D) in citrus fruit, which uses flow-injection ion spray ionization tandem mass spectrometry, has been developed for the first time. The method involves the combined use of stable isotopically labeled internal standards (DDVP-d6, malathion-d10, carbaryl-d7, and 2,4-D-d5) and a multiple reaction monitoring technique. The average recoveries for the pesticides at the same concentrations as their tolerance levels (DDVP: 0.1-0.2 μg g−1; malathion: 0.5-4.0 μg g−1; carbaryl: 1.0 μg g−1; 2,4-D: 1.0-2.0 μg g−1) ranged from 90 to 119% with the relative standard deviation (R.S.D.) ranging from 1.0 to 13.1% (n = 5). Analysis time, including sample preparation and determination, was only 15 min. The present method is effective for screening DDVP, malathion, carbaryl, and 2,4-D in citrus fruit.  相似文献   

8.
Hydrogen peroxide and nicotinamide adenine dinucleotide (NADH) may be determined amperometrically using screen-printed electrodes chemically modified with iron(III) hexacyanoosmate(II) (Osmium purple) in flow injection analysis (FIA). The determination is based on the exploitation of catalytic currents resulting from the oxidation/reduction of the modifier. The performance of the sensor was characterized and optimized by controlling several operational parameters (applied potential, pH and flow rate of the phosphate buffer). Comparison has been made with analogous complexes of ruthenium (Ruthenium purple) and iron (Prussian blue). Taking into account the sensitivity and stability of corresponding sensors, the best results were obtained with the use of Osmium purple. The sensor exhibited a linear increase of the amperometric signal with the concentration of hydrogen peroxide in the range of 0.1-100 mg L−1 with a detection limit (evaluated as 3σ) of 0.024 mg L−1 with a R.S.D. 1.5% for 10 mg L−1 H2O2 under optimized flow rate of 0.4 mL min−1 in 0.1 M phosphate buffer carrier (pH 6) and a working potential of +0.15 V versus Ag/AgCl. Afterwards, a biological recognition element - either glucose oxidase or ethanol dehydrogenase - was incorporated to achieve a sensor facilitating the determination of glucose or ethanol, respectively. The glucose sensor gave linearity between current and concentration in the range from 1 to 250 mg L−1 with a R.S.D. 2.4% for 100 mg L−1 glucose, detection limit 0.02 mg L−1 (3σ) and retained its original activity after 3 weeks when stored at 6 °C. Optimal parameters in the determination of ethanol were selected as: applied potential +0.45 V versus Ag/AgCl, flow rate 0.2 mL min−1 in 0.1 M phosphate buffer carrier (pH 7). Different structural designs of the ethanol sensor were tested and linearity obtained was up to 1000 mg L−1 with a maximum R.S.D. of 5.1%. Applications in food analysis were also examined.  相似文献   

9.
Simone M. Marques 《Talanta》2009,77(4):1497-327
Two new methods for inorganic pyrophosphate (PPi) quantification are described. They are based on the enzymatic conversion of PPi into ATP by firefly luciferase (Luc, E.C. 1.13.12.7) in the presence of dehydroluciferyl-adenylate (L-AMP) followed by the determination of ATP by one of two different procedures, either UV-monitored (260 nm) ion-pair-HPLC (IP-HPLC) (method A) or luciferase-dependent bioluminescence in the presence of its substrate, firefly luciferin (d-LH2) (method B). These methods were subjected to optimization using experimental design methodologies to obtain optimum values for the selected factors: method A—incubation time (tinc = 15 min), inactivation time of the enzyme (tinac = 2 min), pH of the reaction mixture (pH 7.50) and the concentrations of L-AMP ([L-AMP] = 40 μM) and luciferase ([Luc] = 0.1 μM); method B—concentrations of L-AMP ([L-AMP] = 2 μM), luciferase ([Luc] = 50 nM) and luciferin ([LH2] = 30 μM). Method A has a linear response over the range of 0.1-20 μM of PPi, with a limit of detection (LOD) of 0.5 μM and a limit of quantitation (LOQ) of 1.8 μM. Precision, expressed as relative standard deviation (R.S.D.), is 7.4% at 1 μM PPi and 5.9% at 8 μM PPi. Method B has a linear response over the range of 0.75-6.0 μM of PPi, with LOD and LOQ of 0.624 and 2.23 μM, respectively, and a R.S.D. of 5.1% at 2.5 μM PPi and 4.9% at 5 μM PPi. Under optimized conditions sensitive and robust methods can be obtained for the analysis of PPi impurities in commercial nucleotides and tripolyphosphate (P3).  相似文献   

10.
A simple microwave-assisted extraction and partitioning method (MAEP) using water-acetonitrile and n-hexane for desorption and simultaneous partitioning, respectively, together with gas chromatography (GC) was studied to determine representative pesticides (trifluralin, metolachlor, chlorpyriphos and triadimefon) with a broad range of physico-chemical properties in agricultural soils. Three points were considered crucial in this study: instrumental and sample-associated factors affecting extraction of the target compounds were studied through experimental design; the spiking procedure at trace levels was carried out to reproduce the solute-soil sorption taking place in the environment as closely as possible; and results were analyzed taking into account the adsorption behaviour of the compounds on different kinds of soils. The complete analytical procedure proposed consisted of the MAEP of pesticides from 1.0 g of soil with 1 mL of 1:1 water/acetonitrile mixture, and 5 mL of hexane for trapping. The microwave heating program applied was 2 min at 250 W and 10 min at 900 W, and 130 °C maximum temperature. After extraction, the hexane layer was evaporated to dryness; the residue was re-dissolved and directly analyzed by gas chromatography electron capture detection (GC-ECD). Clean chromatograms were obtained without any additional cleanup step. Besides the four pesticides used to optimise MAEP, the method was applied to determine an additional group of pesticides (triallate, acetochlor, alachlor, endosulphan I and II, endrin, methoxychlor and tetradifon) in different soils. Most of the compounds studied were recovered in good yields with relative standard deviations (R.S.D.s) below 9% and detection limits ranged from 0.004 to 0.036 μg g−1. The described method is efficient and fast to determine hydrophobic pesticides at ng g−1 level in soil with different clay-to-organic matter ratios.  相似文献   

11.
A facile fluorescent method for the determination of hydrazine in aqueous solution with excellent sensitivity was developed. 5-Chlorosalicylaldehyde (CS), a readily commercially available compound, was applied as the derivatization reagent in this work. Under the addition of CS to hydrazine aqueous solution (ethanol/water/acetic acid = 30/66/4), an intense fluorescence enhancement was observed at 570 nm with a large stokes shift of ∼170 nm. Upon the optimal condition, the fluorescence intensity linearly increased with the concentration of hydrazine in the range of 0.2 and 9.3 μM with a correlation coefficient of R2 = 0.9995 (n = 10) and a detection limit of 0.08 μM. The R.S.D. was 2.0% (n = 5). Determination of hydrazine in river and drinking water samples was successfully performed. Hydrazine vapor sensing by the proposed method was also reported.  相似文献   

12.
A high-performance liquid chromatographic method has been developed for the determination in human plasma of the specific serotonin reuptake inhibitor (SSRI) antidepressant paroxetine and its three main metabolites (M1, M2, M3). Fluorescence detection was used, exciting at λ = 294 nm and monitoring emission at λ = 330 nm for paroxetine (λexc = 280 nm, λem = 330 nm for M1 and M2; λexc = 268 nm, λem = 290 nm for M3). Separation was obtained on a reversed-phase C18 column using a mobile phase composed of 66.7% aqueous phosphate at pH 2.5 and 33.3% acetonitrile. Imipramine (λexc = 252 nm, λem = 390 nm) was used as the internal standard. A careful pre-treatment of plasma samples was developed, using solid-phase extraction with C8 cartridges (50 mg, 1 mL). The calibration curves were linear over a working range of 2.5-100 ng mL−1 for paroxetine and of 5-100 ng mL−1 for all metabolites. The limit of detection (LOD) was 1.2 ng mL−1 for PRX and 2.0 ng mL−1 for the metabolites. The method was applied with success to plasma samples from depressed patients undergoing treatment with paroxetine. Hence, the method seems to be suitable for the therapeutic drug monitoring of paroxetine and its main metabolites in depressed patients’ plasma.  相似文献   

13.
A new chemiluminescence biochemical oxygen demand (BODCL) determining method was studied by employing redox reaction between quinone and Baker's yeast. The measurement was carried out by utilizing luminol chemiluminescence (CL) reaction catalyzed by ferricyanide with oxidized quinone of menadione, and Saccharomyces cerevisiae using a batch-type luminometer. In this study, dimethyl sulfoxide was used as a solvent for menadione. After optimization of the measuring conditions, the CL response to hydrogen peroxide in the incubation mixture had a linear response between 0.1 and 100 μM H2O2 (r2 = 0.9999, 8 points, n = 3, average of relative standard deviation; R.S.D.av = 4.22%). Next, a practical relationship between the BODCL response and the glucose glutamic acid concentration was obtained over a range of 11-220 mg O2 L−1 (6 points, n = 3, R.S.D.av 3.71%) with a detection limit of 5.5 mg O2 L−1 when using a reaction mixture and incubating for only 5 min. Subsequently, the characterization of this method was studied. First, the BODCL responses to 16 pure organic substances were examined. Second, the influences of chloride ions, artificial seawater, and heavy metal ions on the BODCL response were investigated. Real sample measurements using river water were performed. Finally, BODCL responses were obtained for at least 8 days when the S. cerevisiae suspension was stored at 4 °C (response reduction, 69.9%; R.S.D. for 5 testing days, 18.7%). BODCL responses after 8 days and 24 days were decreased to 69.9% and 35.8%, respectively, from their original values (R.S.D. for 8 days involving 5 testing days, 18.7%).  相似文献   

14.
Luminescent silicon dioxide nano-particles with size of 20 nm, which containing dibromofluorescein (D) were synthesized by sol-gel method (symbolized by D-SiO2).The particles can emit intense and stable room temperature phosphorescence signal on polyamide membrane when Pb(Ac)2 was used as a heavy atom perturber. The λexmax/λemmax was 457/622 nm. Our research indicated that the specific immune reaction between goat-anti-human IgG antibody labeled with D-SiO2 and human IgG could be carried out on polyamide membrane quantitatively, and the phosphorescence intensity of the particle was enhanced after the immunoreactions. Thus a new method of solid substrate room temperature phosphorescence immunoassay (SS-RTP-IA) for the determination of human IgG was established basing on antibody labeled with the D-SiO2 nanoparticles. The linear range of this method was 0.0624-20.0 pg human IgG spot−1 (corresponding concentration: 0.156-50.0 ng ml−1, the sample volume: 0.40 μl spot−1) with a limit of detection (LD) as 0.018 pg spot−1, and the regression equation of working curve was ΔIp = 7.201 mIgG (pg spot−1) + 82.57. Samples containing 0.156 and 50.0 ng ml−1 of IgG were measured repeatedly for 11 times and R.S.D.s were 4.1 and 3.4%, respectively. Results showed that this method had the merits as sensitive, accurate and precise.  相似文献   

15.
Tang B  Yue T  Wu J  Dong Y  Ding Y  Wang H 《Talanta》2004,64(4):955-960
A novel fluorescent reagent o-vanillin-8-aminoquinoline(OVAQ) was synthesized, and its infrared spectrum, elemental analysis and acid-base dissociation constants were obtained. The fluorescent reaction of this reagent with Cr(III) was studied. In acetonitrile-water (1:1, (v/v)) medium of pH 6.00, Cr(III) could react with fluorescent reagent OVAQ (λex/em=280/314 nm) to form a 1:1 non-fluorescent complex. The linear range of the spectrofluorimetric method proposed was from 8.2 to 130 μg l−1, and the detection limit was 2.5 μg l−1. The interferences of 25 foreign ions were also studied. This method could be easily performed and was successfully applied to the determination of Cr(III) and total chromium in domestic and industrial waste water samples.  相似文献   

16.
In this work, we develop a simple and rapid sensing method for the visual and fluorescent detection of acetamiprid (AC) based on the inner-filter effect (IFE) of gold nanoparticles (AuNPs) on ratiometric fluorescent quantum dots (RF-QDs). The RF-QDs based dual-emission nanosensor was fabricated by assembling green emissive QDs (QDs539 nm, λem = 539 nm) on the surface of red emissive QDs (QDs661 nm, λem = 661 nm)-doped silica microspheres. The photoluminescence (PL) intensity of RF-QDs could be quenched by AuNPs based on IFE. Acetamiprid can adsorb on the surface of AuNPs due to its cyano group that has good affinity with gold, which could induce the aggregation of AuNPs accompanying color change from red to blue. Thus, the IFE of AuNPs on RF-QDs was weakened and the PL intensity of RF-QDs was recovered accordingly. Under the optimized conditions, the PL intensity of the RF-QDs/AuNPs system was proportional to the concentration of AC in the range of 0.025–5.0 μg mL−1, with a detection limit of 16.8 μg L−1. The established method had been used for AC detection in environmental and agricultural samples with satisfactory results.  相似文献   

17.
A novel method was developed for the determination of amiodarone and desethylamiodarone by high-performance liquid chromatography (HPLC) coupled with chemiluminescent (CL) detection. The procedure is based on the post-column photolysis of the analytes into photoproducts which are active in the tris(2,2′-bipyridyl)ruthenium(III) [Ru(bpy)33+] CL system. Ru(bpy)33+ was on-line generated by photo-oxidation of the Ru(II) complex in the presence of peroxydisulfate. The separation was carried out on a Mediterranea C18 column with isocratic elution using a mixture of methanol and 0.017 mol L−1 ammonium sulfate buffer of pH 6.8. Under the optimum conditions, analytical curves, based on standard solutions, were linear over the range 0.1-50 μg mL−1 for amiodarone and 0.5-25 μg mL−1 for desethylamiodarone. The detection limits of amiodarone and desethylamiodarone were 0.02 and 0.11 μg mL−1, respectively. Intra- and inter-day precision values of 0.9% relative standard deviation (R.S.D.) (n = 10) and 1.6% R.S.D. (n = 15), respectively, were obtained. The method was applied successfully to the determination of these compounds in serum and pharmaceutical formulations.  相似文献   

18.
A new biochemical oxygen demand (BOD) sensing method employing a double-mediator (DM) system coupled with ferricyanide and a lipophilic mediator, menadione and the eukaryote Saccharomyces cerevisiae has been developed. In this study, a stirred micro-batch-type microbial sensor with a 560 μL volume and a two-electrode system was used. The chronamperometric response of this sensor had a linear response between 1 μM and 10 mM hexacyanoferrate(II) (r2 = 0.9995, 14 points, n = 3, average of relative standard deviation and R.S.D.av = 1.3%). Next, the optimum conditions for BOD estimation by the DM system (BODDM) were investigated and the findings revealed that the concentration of ethanol, used to dissolve menadione, influenced the sensor response and a relationship between the sensor output and glucose glutamic acid concentration was obtained over a range of 6.6-220 mg O2 L−1 (five points, n = 3, R.S.D.av 6.6%) when using a reaction mixture incubated for 15 min. Subsequently, the characterization of this sensor was studied. The sensor responses to 14 pure organic substances were compared with the conventional BOD5 method and other biosensor methods. Similar results with the BOD biosensor system using Trichosporon cutaneum were obtained. In addition, the influence of chloride ion, artificial seawater and heavy metal ions on the sensor response was investigated. A slight influence of 20.0 g L−1 chloride ion and artificial seawater (18.4 g L−1 Cl) was observed. Thus, the possibility of BOD determination for seawater was suggested in this study. In addition, no influence of the heavy metal ions (1.0 mg L−1 Fe3+, Cu2+, Mn2+, Cr3+ and Zn2+) was observed. Real sample measurements using both river water and seawater were performed and compared with those obtained from the BOD5 method. Finally, stable responses were obtained for 14 days when the yeast suspension was stored at 4 °C (response reduction, 93%; R.S.D. for 6 testing days, 9.1%).  相似文献   

19.
This paper describes a novel method that combines dansyl chloride (DNS-CL) derivatization with high-performance liquid chromatography-electrospray ionization tandem mass spectrometry (LC-ESI/MS/MS) for the sensitive and selective determination of piperazine phosphate in human plasma. After addition of ondansetron hydrochloride as internal standard (IS), piperazine phosphate was derivatized and then extracted with ethyl acetate. After being evaporated and reconstituted, the sample was analyzed using LC-ESI/MS/MS. Separation was achieved using an Agilent ZORBAX SB-C18 (150 mm × 2.1 mm I.D., 3.5 μm) column and isocratic elution with 10 mM ammonium acetate solution (pH 3.0)-methanol (50: 50, v/v). Detection was performed on a triple-quadrupole mass spectrometer utilizing electrospray ionization (ESI) interface operating in positive ion and selected reaction monitoring (SRM) mode with the precursor to product ion transitions m/z 320 → 171 for DNS-CL-piperazine phosphate and m/z 294 → 170 for the IS. The method was fully validated for its selectivity, sensitivity, linearity, precision, accuracy, recovery, matrix effect and stability. The coefficient (r) of piperazine phosphate with a linear range of 0.1-15 μg mL−1 was 0.9974-0.9995. The limit of detection and lower limit of quantification in human plasma were 0.01 and 0.1 μg mL−1, respectively. The validated LC-ESI/MS/MS method has been successfully applied to a bioequivalence study of piperazine phosphate trochiscus in Chinese healthy male volunteers.  相似文献   

20.
Polychlorotrifluoroethylene (PCTFE) in the form of beads was applied, as packing material for flow injection on-line column preconcentration and separation systems coupled with flame atomic absorption spectrometry (FAAS). Its performance characteristics were evaluated for trace copper determination in environmental samples. The on-line formed complex of metal with diethyldithiophosphate (DDPA) was sorbed on the PCTFE surface. Isobutyl methyl ketone (IBMK) at a flow rate of 2.8 mL min−1 was used to elute the analyte complex directly into the nebulizer-burner system of spectrophotometer. The proposed sorbent material reveal, excellent chemical and mechanical resistance, fast adsorption kinetics permitting the use of high sample flow rates up to 15 mL min−1 without loss of retention efficiency. For copper determination, with 90 s preconcentration time the sample frequency was 30 h−1, the enhancement factor was 250, which could be further improved by increasing the loading (preconcentration) time. The detection limit (3s) was cL = 0.07 μg L−1, and the precision (R.S.D.) was 1.8%, at the 2.0 μg L−1 Cu(II) level. For lead determination, the detection limit was cL = 2.7 μg L−1, and the precision (R.S.D.) 2.2%, at the 40.0 μg L−1 Pb(II) level. The accuracy of the developed method was evaluated by analyzing certified reference materials and by recovery measurements on spiked natural water samples.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号