首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 750 毫秒
1.
A molecularly imprinted solid phase extraction (MISPE) method has been developed for the rapid screening of metformin. Newly synthesized molecularly imprinted polymer (MIP) particles were slurry-packed into a micro-column for selective solid phase extraction (SPE) of metformin. With CH3CN flowing at 0.5 ml/min, a total binding capacity of 1600 ng metformin was determined for the 20 mg of MIP particles. A broad range of MISPE conditions was evaluated with respect to sample solvent, pH, and buffer compositions. A 95±2% binding could be achieved from one 20-μl injection of sample solution in acetonitrile plus phosphate buffer, up to 1200 ng of metformin. However, the micro-column interacted indiscriminately with phenformin, a structural analogue, to attain 49±2% binding. Separation of phenformin from metformin was ultimately achieved, using differential pulsed elution (DPE) with 1 M trifluoromethacrylic acid in acetonitrile. Final pulsed elution (FPE) using 3% trifluoroacetic acid in methanol was good for the quantitative elution of metformin. The MISPE–DPE–FPE method, with UV detection at 240 nm, afforded a detection limit of 0.8 μg/ml (or 16 ng) for metformin. Each MISPE–DPE–FPE analysis required less than 5 min to complete.  相似文献   

2.
Zhu G  Fan J  Gao Y  Gao X  Wang J 《Talanta》2011,84(4):1124-1132
A surface molecularly imprinted polymer (MIP) was synthesized by using imidazole as the template and modified silica particles as the support material. The static adsorption, solid phase extraction (SPE) and high-performance liquid chromatography (HPLC) experiments were performed to investigate the adsorption properties and selective recognition characteristics of the polymer for imidazole and its structural analogs. It was shown that the maximum binding capacities of imidazole on the MIP and the non-imprinted polymer (NIP) were 312 and 169 μmol g−1, respectively. The adsorption was fast and the adsorption equilibrium was achieved in 30 min. The binding process could be described by pseudo-second order kinetics. Compared with the corresponding non-imprinted polymer, the molecularly imprinted polymer exhibited much higher adsorption performance and selectivity for imidazole. The selective separation of imidazole from a mixture of 1-hexyl-3-methylimidazolium bromide ([C6mim][Br]) and 2,4-dichlorophenol could be achieved on the MIP-SPE column. The recoveries of imidazole and [C6mim][Br] were 97.6-102.7% and 12.2-17.3%, respectively, but 2,4-dichlorophenol could not be retained on the column. The surface molecularly imprinted polymer presented here may find useful application as a solid phase absorbent to separate trace imidazole in environmental water samples. This may also form the basis for our research program on the preparation and application of alkyl-imidazolium imprinted polymers.  相似文献   

3.
In this work, a novel method is described for the determination of bromhexine in biological fluids using molecularly imprinted solid-phase extraction as the sample cleanup technique combined with high performance liquid chromatography (HPLC). The water-compatible molecularly imprinted polymers (MIPs) were prepared using methacrylic acid as functional monomer, ethylene glycol dimethacrylate as cross-linker, chloroform as porogen and bromhexine as the template molecule. The novel imprinted polymer was used as a solid-phase extraction sorbent for the extraction of bromhexine from human serum and urine. Various parameters affecting the extraction efficiency of the polymer have been evaluated. The optimal conditions for molecularly imprinted solid-phase extraction (MISPE) consisted of conditioning 1 mL methanol and 1 mL of deionized water at neutral pH, loading of 5 mL of the water sample (25 μg L−1) at pH 6.0, washing using 2 mL acetonitrile/acetone (1/4, v/v) and elution with 3× 1 mL methanol/acetic acid (10/1, v/v). The MIP selectivity was evaluated by checking several substances with similar molecular structures to that of bromhexine. Results from the HPLC analyses showed that the calibration curve of bromhexine using MIP from human serum and urine is linear in the ranges of 0.5-100 and 1.5-100 μg L−1 with good precisions (3.3% and 2.8% for 5.0 μg L−1), respectively. The recoveries for serum and urine samples were higher than 92%.  相似文献   

4.
Tianhe Jiang  Baolin Chu  Wei Yan 《Talanta》2009,78(2):442-447
A molecularly imprinted polymer (MIP) has been synthesized by a thermo-polymerization method using methacrylic acid (MAA) as functional monomer, ethylene glycol dimethacrylate (EGDMA) as cross-linker, acetonitrile as porogenic solvent, and 17β-estradiol as template. The MIP showed obvious affinity for 17β-estradiol in acetonitrile solution, which was confirmed by absorption experiments. After optimization of molecularly imprinted solid-phase extraction (MISPE) conditions, three structurally related estrogenic compounds (17β-estradiol, estriol, and diethylstilbestrol) were used to evaluate the selectivity of the MIP cartridges. The MIP cartridges exhibited highly selectivity for E2, the recoveries were 84.8 ± 6.53% for MIPs and 19.1 ± 1.93% for non-imprinted polymer (NIP) cartridges. The detection and quantification limits correspond to 0.023 and 0.076 mg L−1. Furthermore, the MISPE methods were used to selectively extract E2 from fish and prawn tissue prior to HPLC analysis. This MISPE-HPLC procedure could eliminate all matrix interference simultaneously and had good recoveries (78.3-84.5%).  相似文献   

5.
In this work, a novel molecularly imprinted polymer (MIP) for use as a solid phase extraction sorbent was developed for the determination of coenzyme Q10 (CoQ10) in liver extract. CoQ10 is an essential cofactor in mitochondrial oxidative phosphorylation and a powerful antioxidant agent found in low concentrations in biological samples. This fact and its high hydrophobicity make the analysis of CoQ10 technically challenging. Accordingly, a MIP was synthesised using coenzyme Q0 as the template, methacrylic acid as the functional monomer, acetonitrile as the porogen, ethylene glycol dimethacrylate as the crosslinker and benzoyl peroxide as the initiator. Various parameters affecting the polymer preparation and extraction efficiency were evaluated. Morphological characterisation of the MIP and its proper comparison with C18 as a sorbent in solid phase extraction were performed. The optimal conditions for the molecularly imprinted solid phase extraction (MISPE) consisted of 400 μL of sample mixed with 30 mg of MIP and 600 μL of water to reach the optimum solution loading. The loading was followed by a washing step consisting of 1 mL of a 1-propanol solution (1-propanol:water, 30:70,v/v) and elution with 1 mL of 1-propanol. After clean-up, the CoQ10 in the samples was analysed by high performance liquid chromatography. The extraction recoveries were higher than 73.7% with good precision (3.6–8.3%). The limits of detection and quantification were 2.4 and 7.5 μg g−1, respectively, and a linear range between 7.5 and 150 μg g−1 of tissue was achieved. The new MISPE procedure provided a successful clean-up for the determination of CoQ10 in a complex matrix.  相似文献   

6.
A new molecularly imprinted polymer (MIP) was specifically synthesized as a smart material for the recognition of metformin hydrochloride in solid-phase extraction. Particles of this MIP were packed into a stainless-steel tubing (50 mm x 0.8 mm i.d.) equipped with an exit frit. This micro-column was employed in the development of a molecularly imprinted solid-phase extraction (MISPE) method for metformin determination. The MISPE instrumentation consisted of a micrometer pump, an injector valve equipped with a 20-microl sample loop, a UV detector, and an integrator. With CH3CN as the mobile phase flowing at 0.5 ml/min, 95 +/- 2% binding could be achieved for 1200 ng of metformin from one injection of a phosphate-buffered sample solution (pH 2.5). Methanol + 3% trifluoroacetic acid was good for quantitative pulsed elution (PE) of the bound metformin. The MISPE-PE method, with UV detection at 240 nm, afforded a detection limit of 16 ng (or 0.8 microg/ml) for metformin. However, the micro-column interacted indiscriminately with phenformin with a 49 +/- 2% binding. A systematic investigation of binding selectivity was conducted with respect to sample composition (including the solvent, matrix, pH, buffer and surfactant effects). An intermediate step of differential pulsed elution used acetonitrile with 5% picric acid to remove phenformin and other structural analogues. A final pulsed elution of metformin for direct UV detection was achieved using 3% trifluoroacetic acid in methanol.  相似文献   

7.
In this work, a molecularly imprinted polymer (MIP) of morphine (MO) was prepared through thermal radical copolymerization of methacrylic acid (MAA) and ethylene glycol dimethacrylate (EDMA) in the presence of MO templates, and a molecularly imprinted sorbent assay (MIA) based on a colorimetric reporter was developed to determine the adsorption isotherm of MO-MIP binding. In practice, the MO-bound MIP was brought into contact with an aqueous mixture of Fe3+ and [Fe(CN)6]3− so that the 3-phenolic group of MO was oxidized and Fe3+ was reduced to Fe2+. As a result, the MO-bound MIP was stained with Prussian blue (PB), which was attributed to the instant co-precipitation of Fe2+ and [Fe(CN)6]3− (Ksp=10−40). Accordingly, MO-MIP binding of the blue dye could be detected by visible spectroscopy. In addition, such staining could successfully distinguish MO from codeine. Upon data analyses, a two-site binding isotherm with two dissociation constants of 6.00×10−5 and 1.03×10−3 M was found for MO-MIP binding. MIAs for non-MIP were also performed. In addition, the results of flow-system characterizations and the particle size effect are also described in this paper.  相似文献   

8.
A molecularly imprinted polymer (MIP) designed to enable the selective extraction of carbamazepine (CBZ) from effluent wastewater and urine samples has been synthesised using a non-covalent molecular imprinting approach. The MIP was evaluated chromatographically in the first instance and its affinity for CBZ also confirmed by solid-phase extraction (SPE). The optimal conditions for SPE consisted of conditioning of the cartridge using acidified water purified from a Milli-Q system, loading of the sample under basic aqueous conditions, clean-up using acetonitrile and elution with methanol. The attractive molecular recognition properties of the MIP gave rise to good CBZ recoveries (80%) when 100 mL of effluent water spiked with 1 μg L−1 was percolated through the polymer. For urine samples, 2 mL samples spiked with 2.5 μg L−1 CBZ were extracted with a recovery of 65%. For urine, the linear range was 0.05-24 mg L−1, the limit of detection was 25 μg L−1 and precision, expressed as relative standard deviation at 0.5 mg L−1 (n = 3), was 3.1% and 12.6% for repeatability and reproducibility between days, respectively.  相似文献   

9.
A kind of new temperature sensitive molecularly imprinted polymer (MIP) with ofloxacin (OFL) as template was prepared for the coating of solid phase microextraction (SPME). Dopamine was self-polymerized on stainless steel fiber (SSF) as the SPME support followed by silanization. Then MIP was synthesized as SPME coating on the modified SSF in a capillary, with N-isopropyl acrylamide as temperature sensitive monomer and methacrylic acid as functional monomer. The synthesis could be well repeated with multiple capillaries putting in the same reaction solution. The obtained MIP fiber was evaluated in detail with different techniques and various adsorption experiments. At last the MIP fiber was used to extract the OFL in milk. Satisfied recoveries between 89.7 and 103.4% were obtained with the limit of quantification (LOQLC) of 0.04 μg mL−1 by the method of SPME coupled with high performance of liquid chromatography (HPLC).  相似文献   

10.
Two molecularly imprinted polymers (MIPs), in the physical form of well-defined polymer microspheres, were synthesised via precipitation polymerisation (PP) using an antiepileptic drug, carbamazepine (CBZ), as template molecule, methacrylic acid as functional monomer and either divinylbenzene 80 (DVB-80) or a mixture of DVB-80 and ethylene glycol dimethacrylate (EGDMA) as crosslinking agents. The MIP obtained using DVB-80 alone as crosslinking agent (MIP A) had a narrow particle size distribution (9.5 ± 0.5 μm) and a well-developed permanent pore structure (specific surface area in the dry state = 758 m2 g−1), whereas when a mixture of DVB-80 and EGDMA (MIP B) were used as crosslinking agents, the polymer obtained had a broader particle size distribution (6.4 ± 1.8 μm) and a relatively low specific surface area (23 m2 g−1). The molecular recognition character of both polymers was evaluated by means of LC and then a molecularly imprinted solid-phase extraction (MISPE) protocol; CBZ was recognised by both polymers, and useful cross-selectivity for oxcarbazepine (OCBZ), which is the main metabolite of CBZ, also observed. In a detailed bioanalytical study, MIP A was selected in preference to MIP B since MIP A enabled a high volume of sample to be extracted such that lower limits of detection were achievable using this polymer. High recoveries of CBZ and OCBZ were obtained in a MISPE protocol when 50 mL of human urine spiked at 0.2 mg L−1 were percolated through MIP A (90% and 83%, respectively).  相似文献   

11.
A new molecularly imprinted electrochemiluminescence (ECL) sensor was proposed for highly sensitive and selective determination of ultratrace Be2+ determination. The complex of Be2+ with 4-(2-pyridylazo)-resorcinol (PAR) was chosen as the template molecule for the molecularly imprinted polymer (MIP). In this assay, the complex molecule could be eluted from the MIP, and the cavities formed could then selectively recognize the complex molecules. The cavities formed could also work as the tunnel for the transfer of probe molecules to produce sound responsive signal. The determination was based on the intensity of the signal, which was proportional to the concentrations of the complex molecule in the sample solution, and the Be2+ concentration could then be determined indirectly. The results showed that in the range of 7 × 10−11 mol L−1 to 8.0 × 10−9 mol L−1, the ECL intensity had a linear relationship with the Be2+ concentrations, with the limit of detection of 2.35 × 10−11 mol L−1. This method was successfully used to detect Be2+ in real water samples.  相似文献   

12.
(Liquid + liquid) equilibrium (LLE) data for the {water + acetic acid + dibasic esters mixture (dimethyl adipate + dimethyl glutarate + dimethyl succinate)} system have been determined experimentally at T = (298.2, 308.2, and 318.2) K. Complete phase diagrams were obtained by determining solubility curve and tie-line data. The reliability of the experimental tie-line data was confirmed by using the Othmer-Tobias correlation. The UNIFAC model was used to predict the phase equilibrium in the system using the interaction parameters determined from experimental data between CH2, CH3COO, CH3, COOH, and H2O functional groups. Distribution coefficients and separation factors were compared with previous studies.  相似文献   

13.
A sorbent was synthesized and investigated for molecularly imprinted solid phase extraction (MISPE). Molecularly imprinted polymers (MIP) were synthesized via precipitation polymerization procedure, where 4-vinyl pyridine (4-VP) was used as functional monomer and ethylene glycol dimethacrylate (EDMA) as cross-linking agent. The imprinting effect of the MISPE was evaluated by elution experiments. The resulting MISPE showed high extraction selectivity to water-soluble and fat-soluble synthetic colorants. The determination of multi-residue for three kinds of water-soluble and six kinds of fat-soluble synthetic colorants in chilli products was also investigated by HPLC coupled with MISPE. The mean recoveries calculated by solvent calibration curve for water-soluble and fat-soluble synthetic colorants were from 72.1% to 95.6% for chilli spice and 72.1% to 92.3% for chilli powder. The decision limit (CCα) and the detection capability (CCβ) obtained for water-soluble and fat-soluble synthetic colorants were in the range of 1.2–1.6 and 1.9–2.4 μg kg−1 in chilli spice and chilli powder. The resulting MISPE was successfully used off-line for the determination of nine kinds of synthetic colorants in chilli products.  相似文献   

14.
The synthesis of a T-2 toxin imprinted polymer and its application in food analysis are reported for the first time. A molecularly imprinted polymer (MIP) for the selective recognition of T-2 toxin (T-2) was synthesized by bulk polymerization. Methacrylamide and ethyleneglycol dimethacrylate were applied as functional monomer and cross-linker, respectively. Molecularly imprinted solid-phase extraction (MISPE) procedures were optimized for further application in the analysis of T-2. Scatchard plot analysis revealed that two classes of imprinted binding sites were formed in the imprinted polymer. The dissociation constant (KD) of the higher affinity binding sites was 7.0 μmol/l, while the KD of the lower affinity binding sites was 54.7 μmol/l. The performance of the MIP throughout the clean-up of spiked maize, barley and oat sample extracts was compared with the results obtained when using non-imprinted polymer, OASIS HLB® and immunoaffinity columns (IAC). Depending on the food matrix and the spiked concentration, recoveries after MISPE and non-imprinted solid-phase extraction varied respectively from 60% to 73% and from 21% to 57%. Recoveries obtained after clean-up using OASIS HLB® and IAC were in the range of 74–104% and 60–85%, respectively. Although highest recoveries were obtained with OASIS HLB® sorbents, the designed MIP and the IAC were superior regarding selectivity, cross-reactivity, matrix effect, limits of detection (LOD) and limits of quantification (LOQ). Depending on the matrix, LOD after MISPE ranged from 0.4 μg/kg to 0.6 μg/kg and LOQ from 1.4 μg/kg to 1.9 μg/kg. LOD and LOQ after OASIS HLB® clean-up varied from 0.9 μg/kg to 3.5 μg/kg and from 3.1 μg/kg to 11.7 μg/kg, respectively. The LOD and LOQ values obtained with IAC were in the range of 0.3–2.3 μg/kg and 1.0–7.7 μg/kg, respectively. Analysis of 39 naturally contaminated samples (maize, barley and oat) by liquid chromatography tandem mass spectrometry revealed that the MIP could be an excellent alternative for clean-up of contaminated food samples.  相似文献   

15.
A covalent interaction-based molecularly imprinted polymer (MIP) material for 3-chloro-1,2-propanediol (3-MCPD), a post-testicular anti-fertility agent and possible carcinogen and mutagen in food products containing acid-hydrolyzed vegetable proteins, has been successfully fabricated using 4-vinylphenylboronic acid as the functional monomer. Rebinding assay revealed that the binding constant, KB, for the receptor sites and non-specific sites are 1.93±0.1×104 and 2.74±0.7×102 M−1, respectively. The estimated number of receptor site, Bmax, imprinted is 123.3±3 μmol/g of MIP. The MIP material is able to act as a potentiometric chemosensor for 3-MCPD via increase in Lewis acidity of the receptor sites upon reaction of the arylboronic acid with 3-MCPD to form the more acidic arylboronic acid esters. A simple pH glass electrode is sufficient to monitor the analyte-specific rebinding. In unbuffered aqueous media, linear potentiometric response from 0 to 350 ppm of 3-MCPD can be achieved. The MIP-based chemosensing in a soya sauce matrix has also been attempted. It is found that the dynamic range of the potentiometric chemosensing response of the MIP material is much reduced, probably due to the blocking or deactivation of receptor sites by interferents in soya sauces. Nevertheless, the present work demonstrated the feasibility of using MIP-based chemosensors as semi-quantitative analytical tools for screening purposes in quality control of food products.  相似文献   

16.
Silica particles have been used as supports for the preparation of three different propazine-imprinted polymer formats. First format refers to grafting of thin films of molecularly imprinted polymers (MIPs) using an immobilised iniferter-type initiator (inif-MIP). The other two new formats were obtained by complete filling of the silica pores with the appropriate polymerisation mixture leading to a silica-MIP composite material (c-MIP) followed by the dissolution of the silica matrix resulting in spherical MIP beads (dis-MIP). These techniques offer a mean of fine-tuning the particle morphology of the resulting MIP particles leading to enhanced capacity in chromatographic applications. Porous silica (specific surface area S = 380 m2 g−1, particle size ps = 10 μm, pore volume Vp = 1.083 ml g−1 and pore diameter dp = 10.5 nm), methacrylic acid and ethylenglycol dimethacrylate were used for the preparation of the materials. All the MIP formats imprinted with propazine have been characterised by elemental analysis, FT-IR spectroscopy, nitrogen adsorption and scanning electron microscopy. Further, the materials were assessed as stationary phases in HPLC. Capacity factors, imprinting factors and theoretical plate numbers were calculated for propazine and other related triazines in order to compare the chromatographic properties of the three different stationary phases. For the inif-MIPs the column efficiency depended strongly on the amount of grafted polymer. Thus, only the polymers grafted as thin films of ca. 1.3 nm average thickness show imprinting effects and the highest column efficiency giving plate numbers (N) of 1600 m−1 for the imprinted propazine. The performance of the c-MIP stationary phase decreases as result of the complete pore filling after polymerisation and increases again after the removal of the silica matrix due to a better mass transfer in the porous mirror-image resulting polymer. From this study can be concluded that the inif-MIP shows the best efficiency for use as stationary phase in HPLC for the separation of triazinic herbicides.  相似文献   

17.
An on-line supported liquid membrane-piezoelectric detection system, based on a molecularly imprinted polymer (SLM-QCM-MIP) manifold, has been developed and applied to the quantitative determination of vanillin in food samples. The analyte is extracted from a donor phase into the hydrophobic membrane, and then back extracted into a second aqueous phase used as the acceptor solution. The quantification of vanillin was performed using a quartz crystal microbalance modified with a molecularly imprinted polymer (MIP). The method shows a linear range between 5 and 65 μM, with a relative standard deviation of ±4.8% (at 5 μM). The method was validated by analysing food samples and comparing the results with an SLM based on spectrophotometric quantification.  相似文献   

18.
The system of polyacrylamide incorporated with methacrylic acid and 2-(dimethylamino)ethyl methacrylate was studied for the possibility of imprinting of lysozyme. The results show that approximately 27% (w/w) of the lysozyme template was not able to be extracted from the molecularly imprinted acrylamide polymers. The amount of the lysozyme template able to be extracted was increased by the addition of methacrylic acid. The molecularly imprinted polymer (MIP), which was prepared with 0.573 M acrylamide, 0.573 M methacrylic acid and 0.573 M 2-(dimethylamino)ethyl methacrylate at a total solution concentration of 20% (w/w), was able to adsorb 83% more lysozyme than the non-imprinted polymer. Selectivity of MIP was also studied.  相似文献   

19.
A selective extraction technique based on the combination of liquid membrane (microporous membrane liquid–liquid extraction) and molecularly imprinted polymers (MIP) was applied to triazines herbicides in food samples. Simazine, atrazine and propazine were extracted from aqueous food samples through the hydrophobic porous membrane that was impregnated with toluene, which also formed part of the acceptor phase. In the acceptor phase, the compounds were re-extracted onto MIP particles. The extraction technique was optimised for the amount of molecularly imprinted polymers particles in the organic acceptor phase, extraction time, and type of organic acceptor solvent and desorption solvent. An extraction time of 90 min and 50 mg of MIP were found to be optimum parameters. Toluene as the acceptor phase was found to give higher triazines binding onto MIP particles compared to hexane and combinations of diethyl ether and hexane. 90% methanol in water was found to be the best desorption solvent compared to acetonitrile, methanol and water. The selectivity of the technique was demonstrated by extracting spiked lettuce and apple extracts where clean chromatograms were obtained compared to liquid membrane extraction alone or to the microporous membrane liquid–liquid extraction – non-imprinted polymer combination. The MIP showed a certain degree of group specificity and the extraction efficiency in lettuce extract was 79% (0.72) for simazine, 98% (1.55) for atrazine and 86% (3.08) for propazine.  相似文献   

20.
A facile and efficient molecularly imprinted polymer (MIP) recognition element of electrochemical sensor was fabricated by directly electro-polymerizing monomer o-phenylenediamine (oPD) in the presence of template quinoxaline-2-carboxylic acid (QCA), based on one-step controllable electrochemical modification of poly(pyrrole)-graphene oxide-binuclear phthalocyanine cobalt (II) sulphonate (PPY-GO-BiCoPc) functional composite on glassy carbon electrode (GCE). The MIP film coated on PPY-GO-BiCoPc functional composite decorated GCE (MIP/PPY-GO-BiCoPc/GCE) was presented for the first time. The synergistic effect and electro-catalytic activity toward QCA redox of PPY-GO-BiCoPc functional composite were discussed using various contrast tests. Also, the effect of experimental variables on the current response such as, electro-polymerization cycles, template/monomer ratio, elution condition for template removal, pH of the supporting electrolyte and accumulation time, were investigated in detail. Under the optimized conditions, the proposed MIP sensor possessed a fast rebinding dynamics and an excellent recognition capacity to QCA, while the anodic current response of square wave voltammetry (SWV) was well-proportional to the concentration of QCA in the range of 1.0 × 10−8–1.0 × 10−4 and 1.0 × 10−4–5.0 × 10−4 mol L−1 with a low detection limit of 2.1 nmol L−1. The established sensor was applied successfully to determine QCA in commercial pork and chicken muscle samples with acceptable recoveries (91.6–98.2%) and satisfactory precision (1.9–3.5% of SD), demonstrating a promising feature for applying the MIP sensor to the measurement of QCA in real samples.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号