首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 109 毫秒
1.
A pressurized CEC (pCEC) coupled with on-column chemiluminescence (CL) detection was developed for direct determination of amino acids, which was based on the principle of an enhanced effect of Cu(II)-amino acid complexes on the CL reaction between luminol and hydrogen peroxide in alkaline solution. The effects of some important factors on pCEC separation and CL intensity were systemically investigated. Baseline separation of amino acids including L-histidine (L-His), L-threonine (L-Thr), and L-tyrosine (L-Tyr) was achieved by using a monolithic column with a mobile phase of 5.0x10(-3) mol/L phosphate buffer at pH 8.0 that contained 25% v/v methanol and 5.0x10(-4) mol/L luminol and 1.0x10(-5) mol/L Cu(II) at an applied voltage of -5 kV. The calibration curves of the analytes by plotting the peak height against corresponding concentration were linear over the range of 3.2x10(-6)-3.2x10(-4) mol/L for L-His, 4.1x10(-6)-4.1x10(-4) mol/L for L-Thr, and 6.0x10(-7)-3.0x10(-4) mol/L for L-Tyr. The LODs for L-His, L-Thr, and L-Tyr were 6.4x10(-7), 8.4x10(-7), and 3.0x10(-7) mol/L (S/N = 2), respectively. The proposed method was applied to the analysis of amino acid injection sample with satisfactory results. Mean recoveries for three amino acids were from 84.3 to 89.6%.  相似文献   

2.
A method based on MCE coupled with chemiluminescence (CL) detection was developed for the determination of taurine (Tau) and amino acids including alanine (Ala), glycine (Gly), tryptophan (Trp), glutamic acid (Glu) and aspartic acid (Asp) present in mice single fibrosarcoma (S180) cells. Cell injection, loading, cytolysis, electrophoretic separation and CL detection were integrated onto a simple double‐T microfluidic chip. The intracellular constituents were electrophoretically separated within 150 s. The CL detection was based on the enhancement effects of Tau and amino acids on the CL reaction of luminol with H2O2 and Cu2+. The average amounts of Tau, Trp, Gly, Ala, Glu and Asp in per S180 cell from a cell population were 4.73, 1.23, 2.65, 1.94, 1.61 and 1.99 fmol. Ten S180 cells were analyzed, and the contents of Tau, Trp, Gly, Ala, Glu and Asp in mice single S180 cells were found to be in the range of 1.78–8.84, 0.95–2.31, 1.08–6.87, 1.03–4.05, 0.84–2.61 and 0.82–3.68 fmol, respectively. This work demonstrates that MCE coupled with CL detection is a useful analytical tool that is simple, quick and highly sensitive for single‐cell analysis.  相似文献   

3.
Li M  Lee SH 《Talanta》2007,74(2):265-270
A simple, rapid flow injection chemiluminescence (FI-CL) method has been developed for selective determination of acenaphthylene (ACY), based on the CL produced in the reaction of tris(2,2′-bipyridine)ruthenium(III) (Ru(bipy)33+) and ACY in an acidic buffer solution. Under the optimum experimental conditions, the calibration curve was linear over the range 5.0 × 10−3 to 4.0 × 10−7 mol L−1 for ACY. The detection limit (S/N = 3) was 2.0 × 10−7 mol L−1 and the relative standard deviation of 10 replicate measurements was 2.3% for 5.0 × 10−5 mol L−1 of ACY. Selectivity of CL reaction of ACY from other 15 polycyclic aromatic hydrocarbons (PAHs) was investigated by flow injection method. The method was applied to determine the ACY content in soil.  相似文献   

4.
流动注射化学发光法测定痕量NO_2~-的研究与应用   总被引:1,自引:0,他引:1  
Based on the principle of the reaction of NO2-with I-and formation of I2 in HCl solution,and the chemiluminescence(CL) reaction between luminol and I2 in an alkaline medium.A fairly sensitive,simple and rapid flow-injection analysis-chemiluminescence method for the determina-tion of trace nitrite with the luminal-I——NO2-coupling luminescence system has been developed.Experiment conditions of flow-injection analysis are optimized.When satisfying the condition that Luminol as 4.0×10-4 mol/L,0.7 % KI,0.04 mol/...  相似文献   

5.
This work reports a novel flow injection (FI) method for the determination of captopril, 1-[(2S)-3-mercapto-2-methylpropionyl]-l-proline (CPL), based on the enhancement CPL affords on the chemiluminescence (CL) reaction between luminol and hydrogen peroxide. For this purpose alkaline luminol and hydrogen peroxide solutions were mixed online, the sample containing CPL was injected into an aqueous carrier stream, mixed with the luminol-hydrogen peroxide stream and pumped into a glass flow cell positioned in front of a photomultiplier tube (PMT). The increase in the CL intensity was recorded in the form of FI peaks, the height of which was related to the CPL mass concentration in the sample. Different chemical and instrumental parameters affecting the CL response were investigated. Under the selected conditions, the log-log calibration curve was linear in the range 5-5000 μg l−1 of CPL, the limit of detection was 2 μg l−1 (at the 3σ level), the R.S.D., sr was 3.1% at the 100 μg l−1 level (n=8) and the sampling rate was 180 injections h−1. The method was applied to the determination of CPL in pharmaceutical formulations with recoveries in the range 100±3%.  相似文献   

6.
精氨酸的流动注射化学发光法测定   总被引:3,自引:0,他引:3  
在碱性介质中,精氨酸对硫氰化钾 鲁米诺化学发光体系有增敏作用,建立了用硫氰化钾 鲁米诺 精氨酸体系测定精氨酸的新方法。用该方法测定精氨酸的线性范围为0.01~2.0μg/mL,检出限0.01μg/mL,采样频率为190次/h,对3μg/mL的精氨酸连续平行测量10次,RSD为1.2%。用该方法对皮革屑中酶法提取的精氨酸进行了测定,并与氨基酸测定仪测定的结果进行了比较。  相似文献   

7.
流动注射化学发光法测定甲硝唑   总被引:6,自引:0,他引:6  
在碱性条件下 ,铁氰化钾氧化鲁米诺产生化学发光 ,甲硝唑对该体系有显著的增强作用 (亚铁氰化钾存在时 )。基于此 ,建立了流动注射化学发光测定痕量甲硝唑的新方法。甲硝唑浓度在 2 .0× 1 0 -6~ 4 .0× 1 0 -4 mol L范围内与发光强度呈良好的线性关系 ;检出限 (3σ)为 1 .5× 1 0 -7mol L。相对标准偏差 (c =1 .0× 1 0 -5mol L ,n=1 1 )为 3.6 %。方法已用于制剂中甲硝唑含量测定  相似文献   

8.
在酸性条件下,KMnO4与甲醛能够产生微弱的化学发光,而富马酸依美斯汀的存在能够大大增强该化学发光强度;结合流动注射技术,建立了测定富马酸依美斯汀的流动注射-化学发光新方法。该方法的线性范围分别为3.0×10-8~2.0×10-7g/mL,2.0×10-7~1.0×10-6g/mL和1.0×10-6~8.0×10-6g/mL。检出限为1.0×10-8g/mL,对2.0×10-6g/mL富马酸依美斯汀滴眼液平行测定11次,其相对标准偏差为1.3%。该方法已成功应用于滴眼液中富马酸依美斯汀的含量测定。  相似文献   

9.
流动注射化学发光法测定DL-酪氨酸   总被引:6,自引:1,他引:6  
在甲醛存在下 ,高锰酸钾与DL 酪氨酸能够发生化学发光反应 ,产生很强的化学发光。据此采用流动注射技术 ,建立了一种测定DL 酪氨酸的化学发光分析法。方法的检出限为 2 .9× 1 0 - 8g/mL ,相对标准偏差为 1 .5 % ( 1 .0× 1 0 - 6g/mLDL 酪氨酸 ,n =1 1 ) ,线性范围为 1 .0× 1 0 - 7g/mL~ 5 .0× 1 0 - 6g/mL。  相似文献   

10.
在NaOH-NaHCO3介质中,铁氰化钾氧化西咪替丁产生快速化学发光反应,0.5 s后发光达到最大,2 s后迅速衰减至零。本文结合流动注射技术,建立了一种化学发光测定西咪替丁的新方法。针对这一快速发光反应,设计了与之相应的管路系统和最短的反应管道来捕捉最大化学发光信号,发光强度与西咪替丁质量浓度在5×10-7~1×10-4g/mL范围内呈线性关系,检出限为1.1×10-7g/mL。对5×10-6g/mL西咪替丁进行11次平行测定,相对标准偏差为1.8%。本法已用于西咪替丁片剂的测定。  相似文献   

11.
在碱性条件下,佐米曲谱坦对鲁米诺-K3[Fe(CN)6]化学发光体系有较强的抑制作用,据此建立了佐米曲谱坦的流动注射化学发光分析法。该法的化学发光抑制值ΔI与佐米曲谱坦质量浓度在2.0×10-6~1.2×10-4g/mL范围内,呈良好的线性关系,检出限为7.6×10-7g/mL。对2.5×10-5g/mL佐米曲谱坦测定的相对标准偏差为1.2%(n=11)。方法适用于佐米曲谱坦片中佐米曲谱坦的测定。  相似文献   

12.
A novel chemiluminescence gas-diffusion flow injection system for the determination of arsenic(III) in aqueous samples is described. The analytical procedure involves injection of arsenic(III) samples and standards into a 0.3 mol L−1 hydrochloric acid carrier stream which is merged with a reagent stream containing 0.2% (w/v) sodium borohydride and 0.015 mol L−1 sodium hydroxide. Arsine, generated in the combined carrier/reagent donor stream, diffuses across the hydrophobic Teflon membrane of the gas-diffusion cell into an argon acceptor stream and then reacts with ozone in the flow-through chemiluminescence measuring cell of the flow system. Under optimal conditions, the method is characterized by a wide linear calibration range from 0.6 μg L−1 to 25 mg L−1, a detection limit of 0.6 μg L−1 and a sample throughput of 300 samples per hour at 25 mg L−1 and 450 samples per hour at 25 μg L−1.  相似文献   

13.
流动注射化学发光法测定己烯雌酚   总被引:1,自引:0,他引:1  
基于己烯雌酚对鲁米诺与高碘酸钾在碱性介质中反应产生的化学发光信号有较强的增敏作用,建立了测定己烯雌酚的流动注射化学发光分析法。己烯雌酚质量浓度在13.4—1340μg/L范围内与化学发光强度呈良好的线性关系,检出限(3d)为4μg/L;对26.8μg/L己烯雌酚进行11次平行测定,相对标准偏差(RSD)为1.4%。该法已用于药物制剂中己烯雌酚的测定。  相似文献   

14.
流动注射化学发光法测定那格列奈   总被引:2,自引:0,他引:2  
在碱性介质中,那格列奈对Luminol-H2O2体系的化学发光有很强的抑制作用,据此建立了流动注射化学发光抑制法测定那格列奈的新方法.该法的化学发光抑制值△I与那格列奈的质量浓度在2.0×10-8~1.0×10-6 g/mL范围内,呈良好的线性关系,检出限为1.4×10-8 g/mL;对4.0×10-7 g/mL那格列奈连续进行11次平行测定,相对标准偏差为1.0%;通过对荧光光谱的研究,对机理进行了初步探讨.  相似文献   

15.
流动注射化学发光法测定青霉素G钾   总被引:1,自引:0,他引:1  
在甲醛的存在下,酸性KMnO4与青霉素G钾能够产生很强的化学发光,从而建立了KMnO4-甲醛-青霉素G钾化学发光体系来测定青霉素G钾.青霉素G钾的测定线性范围为2.0×10-7~1.0×10-5 g/mL,方法的检出限为1.4×10-7 g/mL,对4.0×10-7 g/mL的青霉素G钾进行11次平行测定,相对标准偏差为1.0%,用此法测定青霉素G钾取得了较好的结果.  相似文献   

16.
A simple and rapid flow injection (FI) method is reported for the determination of phosphate (as molybdate reactive P) in freshwaters based on luminol chemiluminescence (CL) detection. The molybdophosphoric heteropoly acid formed by phosphate and ammonium molybdate in acidic conditions generated chemiluminescence emission via the oxidation of luminol. The detection limit (3× standard deviation of blank) was 0.03 μg P l−1 (1.0 nM), with a sample throughput of 180 h−1. The calibration graph was linear over the range 0.032–3.26 μg P l−1 (r2=0.9880) with relative standard deviations (n=4) in the range 1.2–4.7%. Interfering cations (Ca(II), Mg(II), Ni(II), Zn(II), Cu(II), Co(II), Fe(II) and Fe(III)) were removed by passing the sample through an in-line iminodiacetate chelating column. Silicate interference (at 5 mg Si l−1) was effectively masked by the addition of tartaric acid and other common anions (Cl, SO42−, HCO3, NO3 and NO2) did not interfere at their maximum admissible concentrations in freshwaters. The method was applied to freshwater samples and the results (26.1±1.1–62.0±0.4 μg P l−1) were not significantly different (P=0.05) from results obtained using a segmented flow analyser method with spectrophotometric detection (24.4±4.45–84.0±16.0 μg P l−1).  相似文献   

17.
A gas-diffusion flow injection method for the chemiluminescence detection of Hg(II) based on the luminol-H2O2 reaction was developed. The analytical procedure involved the injection of Hg(II) samples and standards into a 1.50 M H2SO4 carrier stream, which was subsequently merged with a reagent stream of 0.60% (w/v) SnCl2 in 1.50 M H2SO4 to reduce Hg(II) to metallic Hg. The gas-diffusion cell was thermostated at 85 °C to enhance the vaporisation of metallic Hg. Mercury vapour, transported across the Teflon membrane of the gas-diffusion cell into the acceptor stream containing 1.00 × 10−4 M KMnO4 in 0.30 M H2SO4, was oxidised back to Hg(II). The acceptor stream was merged with a reagent stream containing 2.50 M H2O2 in deionised water and then the combined stream was merged with another reagent stream containing 7.50 × 10−3 M luminol in 3.00 M NaOH at a confluence point opposite to the photomultiplier tube of the detection system. The chemiluminescence intensity of the luminol-H2O2 reaction was enhanced by the presence of Hg(II) in the acceptor stream. The corresponding increase was related to the original concentration of Hg(II) in the samples and standards. Under optimal conditions, the chemiluminescence gas-diffusion flow injection method was characterised by a linear calibration range between 1 μg L−1 and 100 μg L−1, a detection limit of 0.8 μg L−1 and a sampling rate of 12 samples per hour. It was successfully applied to the determination of mercury in seawater and river samples.  相似文献   

18.
流动注射化学发光法测定阿莫西林   总被引:4,自引:0,他引:4  
在碱性介质中 ,阿莫西林抗生素对鲁米诺 KMnO4化学发光反应有增敏作用 ,据此建立了微量快速测定阿莫西林的流动注射化学发光分析法。该法线性范围为 1 .0× 1 0 -7~ 5 .0× 1 0 -5g mL ,检出限为 3.0× 1 0 -8g mL ;对 1 .0× 1 0 -6g mL阿莫西林 1 1次平行测定 ,其相对标准偏差为 1 .7%。此法已用于阿莫西林胶囊中阿莫西林的测定。  相似文献   

19.
Kalman滤波流动注射化学发光法同时测定铂钯的研究   总被引:3,自引:0,他引:3  
利用Luminol H2O2 OP Pt(Pd)化学发光新体系以及Kalman滤波化学计量学方法建立了流动注射化学发光法同时测定铂钯的新方法。方法的检出限:铂为2.2×10-8g mL、钯为2.4×10-8g mL,铂钯相对标准偏差分别为0.9%和3%。采用阳离子交换树脂静态吸附分离,消除贱金属离子的干扰。可用于贫铂矿中铂、钯的同时测定。  相似文献   

20.
This work describes development of a flow injection (FI) system for determination of iodide, based on the chemiluminescence (CL) reaction between iodine and luminol. Iodide in the sample zone is oxidized to iodine. Employment of a gas-diffusion (GD) unit allows for selective detection of the generated CL (425 nm). Preliminary results showed for concentrations of less than 2 mg L−1, that signals were irreproducible and that the calibration was not linear.In order to solve these problems, a method of ‘membrane conditioning’ was investigated, in which iodide stream was continuously merged with oxidant to generate I2 that conditioned the GD membrane and tubing. This minimized surface interaction between the active surface and the I2 generated from the samples, thus improving both precision and sensitivity. By employing membrane conditioning, it has been possible to reliably detect concentrations down to 0.1 mg L−1.At the optimized condition, an excellent linear calibration (r2 = 0.999) was obtained from 0.1 to 1.0 mg L−1. The method was successfully applied to determine iodide in some pharmaceutical products such as potassium iodide tablets and a liquid patent medicine. However, for vitamin tablets, ascorbic acid was found to interfere seriously by causing a negative signal.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号