首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
An automated system to perform liquid-liquid extraction is proposed, in which the effective mixture (the intimate contact) between the aqueous phase and the organic phase, as well as the separation of the phases, are carried out in a micro-batch glass extraction chamber. Sample, reagents and organic solvent are introduced into the glass extraction chamber by a peristaltic pump using air as carrier. The detection of the extracted species from the aqueous phase is made in a small volume (120-150 μl) of isobutyl methyl ketone (MIBK). The system allows enrichment factors of 2-10-fold. The proposed automatic system was evaluated for Cu(II) extraction based on complex formation between copper(II) and 1-(2′-pyridylazo)naphthol (PAN) in MIBK. When a volumetric ration of 2:1 (aqueous:organic) was implemented, copper was detected in the concentration range of 100-1600 μg l−1 (r = 0.9995) with a relative standard deviation of 2% (200 μg l−1, n = 5) and a detection limit of 20 μg l−1. The analytical curve was linear over the concentration range 25-500 μg l−1 (r = 0.9994) when a volumetric ratio of 10:1 was employed. With this ratio, the detection limit was 5.0 μg l−1 and the relative standard deviation was 6% (50 μg l−1, n = 5).  相似文献   

2.
In this study, a simple, rapid and efficient method, dispersive liquid-liquid microextraction (DLLME) combined gas chromatography-electron capture detection (GC-ECD), for the determination of chlorobenzenes (CBs) in water samples, has been described. This method involves the use of an appropriate mixture of extraction solvent (9.5 μl chlorobenzene) and disperser solvent (0.50 ml acetone) for the formation of cloudy solution in 5.00 ml aqueous sample containing analytes. After extraction, phase separation was performed by centrifugation and the enriched analytes in sedimented phase were determined by gas chromatography-electron capture detection (GC-ECD). Our simple conditions were conducted at room temperature with no stiring and no salt addition in order to minimize sample preparation steps. Parameters such as the kind and volume of extraction solvent, the kind and volume of disperser solvent, extraction time and salt effect, were studied and optimized. The method exhibited enrichment factors and recoveries ranging from 711 to 813 and 71.1 to 81.3%, respectively, within very short extraction time. The linearity of the method ranged from 0.05 to 100 μg l−1 for dichlorobenzene isomers (DCB), 0.002-20 μg l−1 for trichlorobenzene (TCB) and tetrachlorobenzene (TeCB) isomers and from 0.001 to 4 μg l−1 for pentachlorobenzene (PeCB) and hexachlorobenzene (HCB). The limit of detection was in the low μg l−1 level, ranging between 0.0005 and 0.05 μg l−1. The relative standard deviations (R.S.D.s) for the concentration of DCB isomers, 5.00 μg l−1, TCB and TeCB isomers, 0.500 μg l−1, PeCB and HCB 0.100 μg l−1 in water by using the internal standard were in the range of 0.52-2.8% (n = 5) and without the internal standard were in the range of 4.6-6.0% (n = 5). The relative recoveries of spiked CBs at different levels of chlorobenzene isomers in tap, well and river water samples were 109-121%, 105-113% and 87-120%, respectively. It is concluded that this method can be successfully applied for the determination of CBs in tap, river and well water samples.  相似文献   

3.
An enrichment procedure for cadmium and lead after their solid phase extraction as dibenzyldithiocarbamate chelates on Dowex Optipore V-493 has been established prior to their flame atomic absorption spectrometric determinations. The analytical parameters including pH, amounts of dibenzyldithiocarbamate, sample volume, etc., were investigated. The effects of alkaline and earth alkaline ions and some metal ions on the retentions of analytes on Dowex Optipore V-493 resin were examined. Under the optimized conditions, the detection limits (3s, n = 21) for cadmium and lead were 0.43 μg L−1 and 0.65 μg L−1, respectively. The relative standard deviation (R.S.D.), and the recoveries of standard addition for this method were lower than 5% (n = 11) and 95-102%, respectively. Three standard reference samples (LGC 6010 Hard drinking water, NIST SRM 2711 Montana soil and GBW 07605 Tea) were introduced for accuracy and precision of analytical data. The proposed solid phase extraction system was successfully applied to the analysis of environmental samples.  相似文献   

4.
The hollow fiber-based stirring extraction bar liquid–liquid microextraction was applied to the extraction of hormones, including 17-α-ethinylestradiol, 17-α-estradiol, estriol, 17-β-estradiol, estrone, 17-α-hydroxyprogesterone, medroxyprogesterone, progesterone and norethisterone acetate, in milk. The present method has the advantages of both hollow fiber-liquid phase microextraction and stirring bar sorptive extraction. The stirring extraction bar was used as both the stirring bar of microextraction, and extractor of the analytes, which can make extraction, clean-up and concentration be carried out in one step. When the extraction was completed, the stirring extraction bar was easy isolated from the extraction system with the magnet. Several experimental parameters, including the type of extraction solvent, the number of hollow stirring extraction bar, extraction time, stirring speed, ionic strength, and desorption conditions were investigated and optimized. The analytes in the extract were derived and determined by gas chromatography mass spectrometry. Under optimal experimental conditions, good linearity was observed in the range of 0.20–20.00 ng mL−1. The limits of detection and quantification were in the range of 0.02–0.06 ng mL−1 and 0.07–0.19 ng mL−1, respectively. The present method was applied to the analysis of milk samples, and the recoveries of analytes were in the range of 93.6–104.6% with the relative standard deviations ranging from 1.6% to 6.2% (n = 5). The results showed that the present method was a rapid and feasible method for the determination of hormones in milk samples.  相似文献   

5.
In this paper, a combined hollow fiber-based liquid three-phase microextraction and voltammetric method are applied for the first time as a highly selective and sensitive method of electrochemical analysis. Desipramine, used as a model compound was extracted from 8 mL aqueous solution (donor phase, 0.10 mol L−1 NaOH) through a thin phase of propyl benzoate inside the pores of a polypropylene hollow fiber and finally into a 10 μL acidic acceptor solution inside the hollow fiber. Three microelectrodes designed and constructed for the purposes of this study were placed into the two ends of the hollow fiber inside the acceptor solution, and voltammetric analysis was performed in-situ during the extraction. After 15 min, the final stable signal was used for analytical applications. Under the optimized conditions, an enrichment factor of 301 was achieved and the relative standard deviation (R.S.D.) of the method was 6.2% (n = 5). The calibration curve was obtained in the range of 5-5000 nmol L−1 with a reasonable linearity (R2 > 0.988) and the limit of detection (LOD) was found to be 0.8 nmol L−1. Finally, the applicability of the proposed method was evaluated by extraction and determination of desipramine in plasma and urine samples without any dilutions.  相似文献   

6.
The applicability of hollow fiber-based liquid phase microextraction (HF-LPME) was evaluated for the extraction and preconcentration of three antidepressant drugs (amitriptyline, imipramine and sertraline) prior to their determination by HPLC-UV. The target drugs were extracted from 11.0 mL of aqueous solution with pH 12.0 (source phase) into an organic extracting solvent (n-dodecane) impregnated in the pores of a hollow fiber and finally back extracted into 24 μL of aqueous solution located inside the lumen of the hollow fiber and adjusted to pH 2.1 using 0.1 M of H3PO4 (receiving phase). The extraction was performed due to pH gradient between the inside and outside of the hollow fiber membrane. In order to obtain high extraction efficiency, the parameters affecting the HF-LPME including pH of the source and receiving phases, the type of organic phase, ionic strength and volume of the source phase, stirring rate and extraction time were studied and optimized. Under the optimized conditions, enrichment factors up to 300 were achieved and the relative standard deviation (R.S.D.%) of the method was in the range of 2-12%. The calibration curves were obtained in the range of 5-500 μg L−1 with reasonable linearity (R2 > 0.998) and the limits of detection (LODs) ranged between 0.5 and 0.7 μg L−1 (based on S/N = 3). Finally, the applicability of the proposed method was evaluated by extraction and determination of the drugs in urine, plasma and tap water samples. The results indicated that hollow fiber microextraction method has excellent clean-up and high-preconcentration factor and can be served as a simple and sensitive method for monitoring of antidepressant drugs in the biological samples.  相似文献   

7.
A headspace solid-phase dynamic extraction (HS-SPDE) technique was developed by the use of polypyrrole (PPy) sorbent, electropolymerized inside the surface of a needle, as a possible alternative to solid-phase microextraction (SPME). Thermal desorption was subsequently, employed to transfer the extracted analytes into the injection port of a gas chromatography-mass spectrometry (GC-MS). The PPy sorbent including polypyrrole-dodecyl sulfate (PPy-DS) was deposited on the interior surface of a stainless steel needle from the corresponding aqueous electrolyte by applying a constant deposition potential. The homogeneity and the porous surface structure of the coating were examined using the scanning electron microscopy (SEM).The developed method was applied to the trace level extraction of some polycyclic aromatic hydrocarbons (PAHs) from aqueous sample. In order to enhance the extraction efficiency and increase the partition coefficient of analytes, the stainless steel needle was cooled at 5 °C, while the sample solution was kept at 80 °C. Optimization of influential experimental conditions including the voltage of power supply, the time of PPy electrodeposition, the extraction temperature, the ionic strength and the extraction time were also investigated. The detection limits of the method under optimized conditions were in the range of 0.002-0.01 ng mL−1. The relative standard deviations (R.S.D.) at a concentration level of 0.1 ng mL−1 were obtained between 7.54 and 11.4% (n = 6). The calibration curves of PAHs showed linearity in the range of 0.01-10 ng mL−1. The proposed method was successfully applied to the extraction of some selected PAHs from real-life water samples and the relative recoveries were higher than 90% for all the analytes.  相似文献   

8.
Homogeneous liquid-liquid extraction method was studied based on a phase separation phenomenon in a ternary solvent system. According to this procedure, mononitrotoloenes were extracted by single-phase extraction in a water/methanol/chloroform, homogeneous ternary solvent system. Methanol and chloroform were used as consolute and extraction solvents, respectively. The homogeneous solution was broken by the addition of salt and a cloudy solution was formed. After centrifugation, the fine droplets of the extraction solvent were sedimented in the bottom of the conical test tube. Analysis of the extracts was carried out by gas chromatography. The optimization procedure was performed using Box-Behnken design. The variables involved were: sample and extraction solvent volumes, consolute solvent volume and phase separator reagent concentration. Optimum results were obtained under the following conditions: sample volume of 5 mL, extraction solvent volume of 55 μL, consolute solvent volume of 1 mL and phase separator reagent concentration; 5% (w/v). Under these conditions, the enrichment factors of 354, 311 and 300, dynamic linear ranges of 0.5-500, 1-500 and 1-500 μg L−1, and limit of detections (LODs) of 0.09, 0.09 and 0.1 μg L−1 were obtained for o-nitrotoluene, m-nitrotoluene and p-nitrotoluene, respectively. Finally, the method was successfully applied to the extraction and determination of MNTs in the waste water samples in the range of micrograms per liter with R.S.Ds. < 13.2%.  相似文献   

9.
A method for the determination of artemether (ART) and its main metabolite dihydroartemisinin (DHA) in plasma employing liquid-phase microextraction (LPME) for sample preparation prior to liquid chromatography-tandem mass spectrometry (LC-MS-MS) was developed. The analytes were extracted from 1 mL of plasma utilizing a two-phase LPME procedure with artemisinin as internal standard. Using the optimized LPME conditions, mean absolute recovery rates of 25 and 32% for DHA and ART, respectively, were achieved using toluene-n-octanol (1:1, v/v) as organic phase with an extraction time of 30 min. After extraction, the analytes were resolved within 5 min using a mobile phase consisting of methanol-ammonium acetate (10 mmol L−1, pH 5.0, 80:20, v/v) on a laboratory-made column based on poly(methyltetradecylsiloxane) attached to a zirconized-silica support. MS-MS detection was employed using an electrospray interface in the positive ion mode. The method developed was linear over the range of 5-1000 ng mL−1 for both analytes. Precision and accuracy were within acceptable levels of confidence (<15%). The assay was applied to the determination of these analytes in plasma from rats treated with ART. The two-phase LPME procedure is affordable and the solvent consumption was very low compared to the traditional methods of sample preparation.  相似文献   

10.
A novel flow injection analysis (FIA) system based on liquid-liquid microextraction and fluorimetric determination was developed for the determination of traces of the Zn2+ ion using 5-(8-hydroxy-2-quinolinylmethyl)-2,8-dithia-5-aza-2,6-pyridinophane (L) as a sensitive and selective fluorimetric sensor, with λex = 373 nm and λem = 530 nm, and hexanol as the extracting organic solvent. In the designed FIA system, the phase separation takes place via gravitation forces in the absence of any segmenter. The influence of pH and ionic strength of the solution, amount of ligand, nature of counter ion, volume of organic solvent, extraction time and coil length was investigated. Under optimized experimental conditions, the calibration curve found to be liner over a concentration range of 0.025-4.53 μg mL−1 (R2 = 0.9951) with a limit of detection of 2.3 ng mL−1. The enrichment factor was 45 and relative standard deviation for 7 replicate determinations was 2.43%. The method is very fast and uses low levels of organic solvents. The proposed method was applied successfully to the determination of zinc(II) in human hair, human serum and two inorganic sludge samples.  相似文献   

11.
In the present work, a new ligandless-dispersive liquid-liquid microextraction (LL-DLLME) method has been developed for preconcentration trace amounts of copper as a prior step to its determination by flame atomic absorption spectrometry. In the proposed approach 1,2-dicholorobenzene and ethanol were used as extraction and dispersive solvents, respectively. Some factors influencing on the extraction efficiency of copper and its subsequent determination were studied and optimized, such as the extraction and dispersive solvent type and volume, pH of sample solution, extraction time and salting out effect. Under the optimal conditions, the calibration curve was linear in the range of 1.0 ng mL−1-0.6 μg mL−1 of copper with R2 = 0.9985. Detection limit was 0.5 ng mL−1 in original solution (3Sb/m) and the relative standard deviation for seven replicate determination of 0.2 μg mL−1 copper was ±1.4%. The proposed method has been applied for determination of copper in standard and water samples with satisfactory results.  相似文献   

12.
An approach for automated fast extraction of the fat content in bakery products based on focused microwave-assisted Soxhlet extraction (FMASE) and gravimetric determination is proposed. The main factors affecting the extraction efficiency—namely, power of irradiation, number of cycles and irradiation time—were optimized using experimental design methodology. The proposed method was applied to six samples, which were classified in two groups—namely, snacks and cookies. The results obtained agree with those provided by the AOAC 920.39 reference extraction method. No significant differences in the extraction efficiency of the fat content in bakery samples using FMASE versus the official method were found. Moreover, a drastic reduction in both the extraction time (60 and 35 min versus 16 and 8 h, respectively, for the two above commented groups) and sample handling are achieved with similar precision (expressed as repeatability and within-laboratory reproducibility standard deviation) to that provided by the AOAC 920.39 method. In addition, the proposed method is cleaner than the reference method as 75-80% of the extractant is recycled.  相似文献   

13.
A novel method, dispersive liquid-liquid microextraction (DLLME) coupled with high-performance liquid chromatography-variable wavelength detector (HPLC-VWD), has been developed for the determination of three phthalate esters (dimethyl phthalate (DMP), diethyl phthalate (DEP), and di-n-butyl phthalate (DnBP)) in water samples. A mixture of extraction solvent (41 μL carbon tetrachloride) and dispersive solvent (0.75 mL acetonitrile) were rapidly injected into 5.0 mL aqueous sample for the formation of cloudy solution, the analytes in the sample were extracted into the fine droplets of CCl4. After extraction, phase separation was performed by centrifugation and the enriched analytes in the sedimented phase were determined by HPLC-VWD. Some important parameters, such as the kind and volume of extraction solvent and dispersive solvent, extraction time and salt effect were investigated and optimized. Under the optimum extraction condition, the method yields a linear calibration curve in the concentration range from 5 to 5000 ng mL−1 for target analytes. The enrichment factors for DMP, DEP and DnBP were 45, 92 and 196, respectively, and the limits of detection were 1.8, 0.88 and 0.64 ng mL−1, respectively. The relative standard deviations (R.S.D.) for the extraction of 10 ng mL−1 of phthalate esters were in the range of 4.3-5.9% (n = 7). Lake water, tap water and bottled mineral water samples were successfully analyzed using the proposed method.  相似文献   

14.
A sample preparation method for the determination of hydroxylated polycyclic aromatic hydrocarbons (OH-PAHs) in sediment samples was developed using gas chromatography–mass spectrometry (GC–MS). Dispersive liquid–liquid microextraction (DLLME) with derivatization was performed following the subcritical water extraction (SWE) that provided which was provided by accelerated solvent extraction (ASE). Several important parameters that affected both SWE extraction and DLLME, such as the selection of organic modifier, its volume, extraction temperature, extraction pressure and extraction time were also investigated. High sensitivity of the hydroxylated PAHs derivatives by N-(tert-butyldimethylsilyl)-N-methyl-trifluoroacetamide (MTBSTFA) could be achieved with the limits of detection (LODs) ranging from 0.0139 (2-OH-nap) to 0.2334 μg kg−1 (3-OH-fluo) and the relative standard deviations (RSDs) between 2.81% (2-OH-phe) and 11.07% (1-OH-pyr). Moreover, the proposed method was compared with SWE coupled with solid phase extraction (SPE), and the results showed that ASE–DLLME was more promising with recoveries ranging from 57.63% to 91.07%. The proposed method was then applied to determine the hydroxylated metabolites of phenanthrene in contaminated sediments produced during the degradation by two PAH-degraders isolated from mangrove sediments.  相似文献   

15.
A dynamic ultrasound-assisted extraction method prior to the gravimetric determination of total fat content in bakery products is proposed. An open approach in which forward-and-back extractant steps and cycles of extract draining and filling of the sample chamber with fresh extractant was used, which provided the best results as compared with both an open system with forward-and-back of a single extractant volume and an one-direction open system. Recoveries from 99.7 to 100.7% compared with Sohxlet extraction were obtained. The repeatability and within laboratory reproducibility, expressed as relative standard deviation (R.S.D.), were 2.04 and 2.74%, respectively. As compared with conventional Soxhlet, the extraction time was shortened more than five times—from 16 to 3 h—in the case of cookies and more of eight times—from 8 to 1 h—in the case of snacks. Thirteen or 25 ml of hexane was required for total extraction in 10 or 20 cycles, depending on the sample.  相似文献   

16.
A new method for determination of volatile terpenoids in wine is proposed. An off-line solid phase extraction—gas chromatographic method has been used for the determination. The influence of several extraction variables was studied, including the solid phase employed (C-18 versus divinylbenzene-based), eluting solvent (n-pentane, dichloromethane, ethanol and methanol), volume of eluting solvent (1-4 ml) and drying time (0-20 min). Complete recovery of volatile terpenoids from several kinds of wines was obtained under the optimized conditions.  相似文献   

17.
A simple, rapid and sensitive method has been developed for the determination of aromatic low-molecular mass aldehydes (LMMAs) such as benzaldehyde (BA) and methyl derivatives in water samples through the use of liquid chromatography-diode array detection (LC-DAD). The method is based on the continuous in situ derivatization of the aldehydes with 2,4-dinitrophenylhydrazine (DNPH) on a LiChrolut EN solid-phase extraction (SPE) column in the presence of sodium dodecyl sulfate (SDS) micelles. After elution, hydrazones were successfully separated on a RP-C18 column using a linear gradient mobile phase of acetonitrile (ACN)-water at 75-95% ACN for 10 min. Linearity was established over the concentration range 0.4-200 μg L-1 and limits of detection (LODs) from 120 to 200 ng L-1; the inter-day precision expressed as the relative standard deviation (RSD) of the aldehydes ranged from 3.0% to 3.5%. The method was successfully applied to the analysis of aromatic and aliphatic LMMAs in water samples with average recoveries ranging between 93.6% and 99.5%. The proposed method surpasses other chromatographic alternatives in terms of LODs, sample requirements for analysis and cost.  相似文献   

18.
A rapid and effective preconcentration method for extraction of rhodamine 6G was developed by using a dispersive liquid-liquid microextraction (DLLME) prior to UV-vis spectrophotometry. In this extraction method, a suitable mixture of acetone (disperser solvent) and chloroform (extractant solvent) was injected rapidly into a conical test tube containing aqueous solution of rhodamine 6G. Therefore, a cloudy solution was formed. After centrifugation of the cloudy solution, sedimented phase was evaporated, reconstituted with methanol and measured by UV-vis spectrophotometry. Different operating variables such as type and volume of extractant solvent, type and volume of disperser solvent, pH of the sample solution, salt concentration and extraction time were investigated. The optimized conditions (extractant solvent: 300 μL of chloroform, disperser solvent: 3 mL of acetone, pH: 8 and without salt addition) resulted in a linear calibration graph in the range of 5-900 ng mL−1 of rhodamine 6G in initial solution with R2 = 0.9988 (n = 5). The Limits of detection and quantification were 2.39 and 7.97 ng mL−1, respectively. The relative standard deviation for 50 and 250 ng mL−1 of rhodamine 6G in water were 2.88% and 1.47% (n = 5), respectively. Finally, the DLLME method was applied for determination of rhodamine 6G in different industrial waste waters.  相似文献   

19.
A rapid dynamic microwave-assisted extraction and on-line detection by spectrophotometry is proposed for the determination of safflower yellow in Flos Carthami. A high pressure and a peristaltic pump were used to deliver the solvent. A TM010 microwave resonance cavity was applied to concentrate the microwave energy and the forward power about 60 W was enough for the extraction. Other extraction conditions also were examined and optimized. In this work, the extraction process can be monitored by measuring the absorption of safflower yellow in the extract, which would be convenient for rapid optimization of the extraction process. The detection and quantification limits are 8 and 27 μg mL−1, respectively. The within-day and between-day precision (R.S.D.) are 1.6-3.2% and 2.8-4.2%, respectively. Compared with off-line detection, the proposed method may provide more rapid measurement and is more convenient for obtaining continuous measurements.  相似文献   

20.
Li Y  Wei G  Hu J  Liu X  Zhao X  Wang X 《Analytica chimica acta》2008,615(1):96-103
A simple, rapid and efficient method, dispersive liquid-liquid microextraction (DLLME), has been developed for the extraction and preconcentration of polybrominated diphenyl ethers (PBDEs) in water samples. The factors influencing microextraction efficiencies, such as the kind and volume of extraction and dispersive solvent, the extraction time and the salt effect, were optimized. Under the optimum conditions (sample volume: 5 mL; extraction solvent: tetrachloroethane, 20.0 μL; dispersive solvent: acetonitrile, 1.00 mL; extraction time: below 5 s and without salt addition), the enrichment factors and extraction recoveries were high and ranged from 268 to 305 and 87.0 to 119.1%, respectively. Linearity was observed in the range 0.05-50 ng mL−1 for BDE-28 and BDE-99, and 0.1-100 ng mL−1 for BDE-47 and BDE-209, respectively. Coefficients of correlation (r2) ranged from 0.9995 to 0.9999. The repeatability study was carried out by extracting the spiked water samples at concentration levels of 50 ng mL−1 for BDE-28 and BDE-99, and 100 ng mL−1 for BDE-47 and BDE-209, respectively. The relative standard deviations (R.S.D.s) varied between 3.8 and 6.3% (n = 5). The limits of detection (LODs), based on signal-to-noise ratio (S/N) of 3, ranged from 12.4 to 55.6 pg mL−1 (the wavelength of detector at 226 nm). The relative recoveries of PBDEs from tap, lake water and landfill leachate samples at spiking levels of 5, 10 and 50 ng mL−1 were in the range of 89.7-107.6%, 114.3-119.1% and 87.0-90.9%, respectively. As a result, this method can be successfully applied for the determination of PBDEs in landfill leachate and environmental water samples.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号