1.
The catalytic adsorptive stripping voltammetry (CAdSV) has been applied to physico-chemical chromium speciation study in the upper Dunajec catchment, severely polluted by the tannery wastewater. The method is based on the adsorptive preconcentration of the Cr(III)-diethylenetriammine-N,N,N′,N″,N″-pentaacetic acid (DTPA) complex and the utilization of the catalytic reaction in the presence of nitrate. Under optimized conditions the CAdSV enables the oxidation state speciation study of Cr content by direct determination of Cr(VI) in the presence of the predominant Cr(III) concentration with the detection limit for chromium(VI) of 0.08 nM and the linearity range from 0.1 to 80 nM obtained for 20 s of accumulation, as well as the determination of total Cr after UV oxidation of Cr(III) to Cr(VI). Due to the difference in the chemical properties of different chromium species the CAdSV method makes possible a speciation study of Cr(III) and Cr(VI) oxidation state. The RSD of the determination of Cr(VI) and Cr(III) varies from 0.5 to 5%. It has been proved that in natural water in which strong complexants of Cr(III) such a humid acids are presented, Cr(VI) can be determined accurately in the presence of high excess of Cr(III). Fractionation of selected water samples with tangential flow filtration (TFF, cut-off 10 and/or 1 kDa) provides insight into physical Cr speciation, i.e. partitioning of the Cr(VI) and Cr(III) between the colloidal and the dissolved fractions. It has been shown that the content of the Cr species in the Dunajec river depends on the season, and is significantly higher in autumn and winter during the most intensive tanneries production processes. The concentration of total Cr exceeds occasionally the legally admissible level. A large fraction of total Cr(III) concentration is associated with the colloidal material, while Cr(VI) occurs solely in the truly dissolved form.  相似文献   

2.
On-line preconcentration system for the selective, sensitive and simultaneous determination of chromium species was investigated. Dual mini-columns containing chelating resin were utilized for the speciation and preconcentration of Cr(III) and Cr(VI) in water samples. In this system, Cr(III) was collected on first column packed with iminodiacetate resin. Cr(VI) in the effluent from the first column was reduced to Cr(III), which was collected on the second column packed with iminodiacetate resin. Hydroxyammonium chloride was examined as a potential reducing agent for Cr(VI) to Cr(III).The effects of pH, sample flow rate, column length, and interfering ions on the recoveries of Cr(III) were carefully studied. Five millilitres of a sample solution was introduced into the system. The collected species were then sequentially washed by 1 M ammonium acetate, eluted by 2 M nitric acid and measured by ICP-AES. The detection limit for Cr(III) and Cr(VI) was 0.08 and 0.15 μg l−1, respectively. The total analysis time was about 9.4 min.The developed method was successfully applied to the speciation of chromium in river, tap water and wastewater samples with satisfied results.  相似文献   

3.
An on-line flow injection (FI) preconcentration-electrothermal atomic absorption spectrometry (ETAAS) method is developed for trace determination of chromium in drinking water samples by sorption on a conical minicolumn packed with activated carbon (AC) at pH 5.0. The chromium was removed from the minicolumn with 1.0% (v/v) nitric acid. An enrichment factor (EF) of 35-fold for a sample volume of 10 ml was obtained. The detection limit (DL) value for the preconcentration method proposed was 3.0 ng l−1. The precision for 10 replicate determinations at the 0.5 μg l−1 Cr level was 4.0% relative standard deviation (R.S.D.), calculate with the peak heights obtained. The calibration graph using the preconcentration system for chromium was linear with a correlation coefficient of 0.9992 at levels near the detection limits up to at least 50 μg l−1. The method was successfully applied to the determination of Cr(III) and Cr(VI) in drinking water samples.  相似文献   

4.
A simple and sensitive multicommutated flow procedure, implemented by employing a homemade light emitting diode (LED) based photometer, has been developed for the determination of chromium (VI) and total chromium in water. The flow system comprised a set of four solenoid micro-pumps, which were assembled to work as fluid propelling and as commutating devices. The core of the detection unit comprised a green LED source, a photodiode and a homemade flow cell of 100 mm length and 2 mm inner diameter. The photometric procedure for the speciation of chromium in natural waters was based on the reaction of Cr (VI) with 1,5-diphenylcarbazide. Cr (III) was previously oxidized to Cr (VI) and determined as the difference between total Cr and Cr (VI). After carrying out the assays to select the best operational conditions the features of the method included: a linear response ranging from 10 to 200 μg l−1 Cr (III) and Cr (VI) (r = 0.999, n = 7); limits of detection of 2.05 and 1.0 μg l−1 for Cr (III) and Cr (VI), respectively; a relative standard deviation lower than 2.0% (n = 20) for a typical solution containing 50 μg l−1 Cr; a sampling throughput of 67 and 105 determinations per hour for total Cr and Cr (VI), respectively, and recovery values within the range of 93-108% for spiked concentrations of the order of 50 μg l−1.  相似文献   

5.
A highly sensitive, selective and simple kinetic method was developed for the determination of dissolved chromium species based on the catalytic effect of Cr(III) and/or Cr(VI) on the oxidation of 2-amino-5-methylphenol (AMP) with H2O2. The fixed time and initial rate variants were used for kinetic spectrophotometric measurements by tracing the oxidized product at 400 nm for 10 min after starting the reaction. Boric acid and Tween-40 exerted pronounced activating and micellar sensitizing effects on the studied redox reaction, respectively. The optimum reaction conditions were: 3.0 mmol l−1 AMP, 0.45 mol l−1 H2O2, 0.50 mol l−1 boric acid, 4 v/v% Tween-40, 10 mmol l−1 phosphate buffer and pH 6.45 ± 0.02 at 35 °C. Both Cr(III) and Cr(VI) ions exerted the same catalytic effect on the studied reaction. Linear calibration graphs were obtained for the determination of up to 6.0 ng ml−1 Cr with detection limits of 0.054 and 0.10 ng ml−1 Cr; following the fixed time and initial rate methods, respectively. The proposed method was successfully applied to the speciation and determination of trace levels of dissolved Cr(III) and Cr(VI) in natural and effluents of industrial waste water. The total dissolved Cr(III) and Cr(VI) species was determined first. In a second run, Cr(VI) was determined alone after precipitation of Cr(III) ions in presence of Al(OH)3 collector, where Cr(III) is then determined by difference. Moreover, published catalytic-spectrophotometric methods for chromium determination were reviewed.  相似文献   

6.
The possibility of using moss (Funaria hygrometrica), immobilized in a polysilicate matrix as substrate for speciation of Cr(III) and Cr(VI) in various water samples has been investigated. Experiments were performed to optimize conditions such as pH, amount of sorbent and flow rate, to achieve the quantitative separation of Cr(III) and Cr(VI). During all the steps of the separation process, Cr(III) was selectively sorbed on the column of immobilized moss in the pH range of 4-8 while, Cr(VI) was found to remain in solution. The retained Cr(III) was subsequently eluted with 10 ml of 2 mol l−1 HNO3. A pre-concentration factor of about 20 was achieved for Cr(III) when, 200 ml of water was passed. The immobilized moss was packed in a home made mini-column and incorporated in flow injection system for obtaining calibration plots for both Cr(III) and Cr(VI) at low ppb levels that were compared with the plots obtained without column. After separation, the chromium (Cr) species were determined by inductively coupled plasma mass spectrometry (ICP-MS) and flame atomic absorption spectrometry (FAAS). The sorption capacity of the immobilized moss was found to be ∼11.5 mg g−1 for Cr(III). The effect of various interfering ions has also been studied. The proposed method was applied successfully for the determination of Cr(III) and Cr(VI) in spiked and real wastewater samples and recoveries were found to be >95%.  相似文献   

7.
The concentrations of chromium (III) and (VI) in fly ash from nine Australian coal fired power stations were determined. Cr(VI) was completely leached by extraction with 0.01 M NaOH solution and the concentration was determined by inductively coupled plasma atomic emission spectrometry (ICP-AES). This was confirmed by determining Cr(III) and Cr(VI) in the extracts of fly ash that had been spiked with chromium salts. These analytical measurements were done using a combination of ion-exchange chromatography and ICP-AES. The elutant was 0.05 M HNO3 containing 0.5%-CH3OH. When the column was operated at a flow rate of 1.2 ml min−1 and samples were injected by use of a sample loop with a volume of 100 μl, Cr(III) and Cr(VI) in sample solution was exclusively separated within approximately 10 min. The detection limits (3σ) were 5 ng for Cr(III) (0.050 mg l−1) and 9 ng for Cr(VI) (0.090 mg l−1), respectively. A relative standard deviation of 1.9% (n = 6) was obtained for the determination by IC-ICP-AES of 0.25 mg l−1 Cr(III) and Cr(VI).  相似文献   

8.
Cui H  He R  Wang J 《Talanta》2006,70(1):139-145
A high sensitive chromium speciation procedure based on spectrophotometric detection was developed by coupling flow injection on-line preconcentration with a catalytic indicator reaction. Chromium(VI) is retained on a mini-column packed with polystyrene anion exchange resin (strong basic 717 resin), which was afterwards eluted with a small volume of NaNO3 solution. The eluted Cr(VI) is then directed to catalyze the decoloration of alizarin cyanine green (ACG) in the presence of bromate as oxidizing reagent, and the absorbance change is proportional to the concentration of Cr(VI). With a sampling volume of 12 ml and a loading time of 120 s, an enrichment factor of 26.5 was achieved for the preconcentration. The most distinct feature of this procedure is characterized by its overall detection limit, i.e., 50 ng l−1, which is much superior to those achieved by FAAS, and comparable to those obtained by inductively coupled plasma mass spectrometry (ICPMS) and electrothermal atomic absorption spectrometry (ETAAS). The procedure was validated with a certified reference material. It was also applied to the speciation of chromium in a series of surface water samples.  相似文献   

9.
The synthesis of a new stable chelating resin from the polystyrene divinylbenzene copolymer is reported. The polystyrene is first functionalized with a phenolic group and then allowed to couple with diazotized anthranilic acid through the NN bond. The resulting polymer containing azophenolcarboxylate with an ONO chelating environment has been characterized by elemental analysis, hydrogen ion capacity, and water regain value. Its stability towards thermal and different chemical environments has been evaluated. The sorption capacity of the chelating resin for Cr(III) and Cr(VI) as a function of pH has been studied. The interesting point is that chromium(III) is selectively retained at ca. pH 5.0 and chromium(VI) at ca. pH 2.0. When packed in a column, the new material is able to separate Cr(III) from Cr(VI). Five replicate determinations of 10 μg Cr(III) and 10 μg Cr(VI) present in 100 mL solution gave recoveries of 96.9 ± 2.9% (for Cr(III)) and 96.2 ± 2.1% (for Cr(VI)) at the 95% confidence level. Calibration graph was linear over the concentration range of 0-250 μg L−1 of chromium species with correlation coefficient (R) of 0.99994. The detection limits based on 3σ criterion were determined to be 0.6 μg L−1 for Cr(III) and 0.9 μg L−1 for Cr(VI). The developed method was successfully used for the speciation of chromium in wastewater.  相似文献   

10.
Scancar J  Milacic R 《The Analyst》2002,127(5):629-633
A new analytical procedure using an anion-exchange separation support based on convective-interaction media (CIM) was developed for the speciation of chromium. The separation of Cr(VI) was performed on a weak anion-exchange CIM diethylamine (DEAE) fast-monolithic chromatographic disc. Buffer A (0.005 mol dm(-3) TRIS-HCl, pH 8.0) and buffer B (buffer A plus 3 mol dm(-3) NH4NO3) were employed in the separation procedure. The separated chromium species were determined 'off-line' by ETAAS in 0.5 cm3 fractions. The applicability of the CIM DEAE-ETAAS procedure was investigated for the determination of airborne Cr(VI) at a plasma cutting workplace. Aerosols were collected on polycarbonate membrane filters of 8 and 0.4 microm pore size (inhalable and respirable aerosols). Alkaline extraction of filters in a heated ultrasonic bath was applied to leach chromium. Good repeatability of measurement (+/-3.0%) of the alkaline extracts was obtained for Cr(VI). The LOD (3s) was found to be 0.30 microg m(-3) Cr(VI), when 0.25 m3 of air was collected on the filter. The validation of the procedure was performed by spiking filters with Cr(VI) and by the analysis of the standard reference material CRM 545, Cr(VI) in welding dust loaded on a filter. Good recoveries for spiked samples (101-102%) and good agreement between Cr(VI) found and the reported certified value for CRM 545 were obtained. The extracts were also analysed by the FPLC-ETAAS technique. Good agreement between two techniques (r2 = 0.9978) confirmed the reliability of the CIM DEAE-ETAAS procedure developed. The main advantage of the procedure lies in the speed of the chromatographic separation (chromatographic run completed in 15 min).  相似文献   

11.
A novel method for the speciation of chromium(III) and chromium(VI) by in situ separation and sequential determination with electrothermal vaporization-inductively coupled plasma-atomic emission spectrometry (ETV-ICP-AES) was developed. The reaction conditions between Cr(III) and 8-hydroxyquinoline (8-Ox) and the vaporization behavior of the chelate formed were investigated in detail. It was found that the Cr(III)-8-Ox chelate could be formed at room temperature and vaporized from graphite furnace under controlled experimental conditions, therefore, an in situ separation of Cr(III) from Cr(VI) was achieved. The retained Cr(VI) in graphite tube was then determined by using fluorination vaporization ETV-ICP-AES with PTFE slurry as chemical modifier. Under optimum experimental conditions, the detection limits for Cr(III) and Cr(VI) are 8.6 ng/ml and 11.3 ng/ml, and the relative standard deviations (R.S.D.s) are 3.8% and 4.1% (c=0.1 μg/ml, n=6), respectively. The linear ranges of the calibration curve for both Cr(III) and Cr(VI) covered three orders of magnitude. The proposed method has been applied to the speciation of Cr(III) and Cr(VI) in water samples with the satisfactory results.  相似文献   

12.
Ma HL  Tanner PA 《Talanta》2008,77(1):189-194
An isotope dilution method has been developed for the speciation analysis of chromium in natural waters which accounts for species interconversions without the requirement of a separation instrument connected to the mass spectrometer. The method involves (i) in-situ spiking of the sample with isotopically enriched chromium species; (ii) separation of chromium species by precipitation with iron hydroxide; (iii) careful measurement of isotope ratios using an inductively coupled plasma mass spectrometer (ICP-MS) with a dynamic reaction cell (DRC) to remove isobaric polyatomic interferences. The method detection limits are 0.4 μg L−1 for Cr(III) and 0.04 μg L−1 for Cr(VI). The method is demonstrated for the speciation of Cr(III) and Cr(VI) in local nullah and synthetically spiked water samples. The percentage of conversion from Cr(III) to Cr(VI) increased from 5.9% to 9.3% with increase of the concentration of Cr(VI) and Cr(III) from 1 to 100 μg L−1, while the reverse conversion from Cr(VI) to Cr(III) was observed within a range between 0.9% and 1.9%. The equilibrium constant for the conversion was found to be independent of the initial concentrations of Cr(III) and Cr(VI) and in the range of 1.0 (at pH 3) to 1.8 (at pH 10). The precision of the method is better than that of the DPC method for Cr(VI) analysis, with the added bonuses of freedom from interferences and simultaneous Cr(III) determination.  相似文献   

13.
Hashemi P  Boroumand J  Fat'hi MR 《Talanta》2004,64(3):578-583
Three different agarose-based chelating adsorbents with, respectively, iminodiacetic acid (IDA), tris(2-aminoethyl)amine (TREN) and dipicolylamine (DPA) functional groups and an agarose-based anion exchanger (Q-Sepharose), were studied for the separation and preconcentration of Cr(III) and Cr(VI) species in water. Column recoveries of all the adsorbents were plotted against pH, and it was found that at pH 3.0 the IDA adsorbent selectively adsorbs Cr(III), with a 100 ± 1.0% recovery. The Q-Sepharose, on the other hand, accumulated only Cr(VI) at this pH, again with a recovery of 100 ± 1.0%. A dual column system was accordingly designed, using the two adsorbents in tandem, for the separation and preconcentration of the chromium species.The effects of pH, sample flow rate, column length, eluent type, eluent volume, acid concentration and interfering ions on the recoveries of Cr(III) and Cr(VI) were carefully studied. It was shown that by passing test solutions, at pH 3.0; through the dual column system, the two chromium species could be individually collected on the columns, respectively, and eluted, one after the other. A portion of 2 mol l−1 hydrochloric acid was used for elution of each column before final measurement by flame AAS method. A preconcentration factor of 12, a detection limit of 7.7 ± 0.1 μg l−1 and a precision expressed as relative standard deviation of 0.4% (at 0.3 mg l−1) were achieved for six replicates.Application of the developed method to the determination of chromium species in spiked river and tap water and wastewater samples, from a dye production plant, resulted in excellent agreements with accepted concentrations.  相似文献   

14.
Chronoamperometric assays based on tyrosinase and glucose oxidase (GOx) inactivation have been developed for the monitoring of Cr(III) and Cr(VI). Tyrosinase was immobilized by crosslinking on screen-printed carbon electrodes (SPCEs) containing tetrathiafulvalene (TTF) as electron transfer mediator. The tyrosinase/SPCTTFE response to pyrocatechol is inhibited by Cr(III). This process, that is not affected by Cr(VI), allows the determination of Cr(III) with a capability of detection of 2.0 ± 0.2 μM and a reproducibility of 5.5%. GOx modified screen-printed carbon platinised electrodes (SPCPtEs) were developed for the selective determination of Cr(VI) using ferricyanide as redox mediator. The biosensor was able to discriminate two different oxidation states of chromium being able to reject Cr(III) and to detect the toxic species Cr(VI). Chronoamperometric response of the biosensor towards glucose decreases with the presence of Cr(VI), with a capability of detection of 90.5 ± 7.6 nM and a reproducibility of 6.2%. A bipotentiostatic chronoamperometric biosensor was finally developed using a tyrosinase/SPCTTFE and a GOx/SPCPtE connected in array mode for the simultaneous determination of Cr(III) and Cr(VI) in spiked tap water and in waste water from a tannery factory samples.  相似文献   

15.
A novel cloud point phase separation of cationic surfactant, Aliquat-336 and capabilities of its reactive solubilizing sites for selective extraction of chromium species at ultra trace levels was examined in natural water. The phase separation behavior of Aliquat-336 is studied with various additives. The nonionic surfactant, Triton X-114 was found to induce the cloud point phase separation of Aliquat-336. The separation of anionic Cr(VI) was enabled by the formation of ion associate with quaternary ammonium head group of Aliquat-336 at pH 2, and the recovery of Cr(VI) and Cr(III) were 101.4 ± 1.4% and 2.2 ± 0.4%, respectively at 0.5-1 ng mL−1, Total Cr was pre-concentrated as Cr-APDC species using the hydrophobic tail group at pH 6.5. The Cr(III) concentration was obtained by subtracting Cr(VI) from total Cr. The recovery of total Cr was 99.5 ± 1.2%. Parameters affecting extraction were assessed. The procedure was applied to NIST 1643c and NIST 1643d waters, and the sum of individual species obtained was compared with the certified chromium values. The method was also applied to various natural waters with limits of detection and pre-concentration factor of 0.010 and 0.025 ng mL−1; 10 and 10, respectively, for Cr(VI) and Cr(III)-APDC using ICP-MS operated in DRC mode.  相似文献   

16.
Maltez HF  Carasek E 《Talanta》2005,65(2):537-542
A procedure for chromium speciation by F AAS using a flow system has been proposed. In this system, Cr(III) and Cr(VI) ions were adsorbed sequentially onto a mini-column packed with silica gel modified with zirconium phosphate and a mini-column packed with silica gel modified with zirconium oxide, respectively. The elution of Cr(III) and Cr(VI) was made with, respectively, nitric acid solution and tris(hydroxymethyl)methylamine (THAM) solution in reverse mode and determination by flame atomic absorption spectrometry without interference of the matrix. Chemical and flow variables as well as concomitant ions were studied in the developed procedure. The enrichment factor for Cr(III) and Cr(VI) was 20.8 and 24.9, respectively, using a preconcentration time of 3.75 min. The limit of detection for Cr(III) and Cr(VI) was 1.9, and 2.3 μg l−1, respectively. The precision of the method, evaluated as the relative standard deviation in solutions containing 100 μg l−1 of chromium species, by analyzing a series of seven replicates, was lower than 3.0%. The accuracy was assessed through recovery experiments of water samples and using another methodology.  相似文献   

17.
A novel on-line preconcentration and determination system based on a fiber-packed column was developed for speciation analysis of Cr in drinking water samples prior to its determination by flame atomic absorption spectrometry (FAAS). All variables involved in the development of the preconcentration method including, pH, eluent type, sample and eluent flow rates, interfering effects, etc., were studied in order to achieve the best analytical performance. A preconcentration factor of 32 was obtained for Cr(VI) and Cr(III). The levels of Cr(III) species were calculated by difference of total Cr and Cr(VI) levels. Total Cr was determined after oxidation of Cr(III) to Cr(VI) with hydrogen peroxide. The calibration graph was linear with a correlation coefficient of 0.999 at levels near the detection limit and up to at least 50 μg L−1. The relative standard deviation (R.S.D.) was 4.3% (C = 5 μg L−1 Cr(VI), n = 10, sample volume = 25 mL). The limit of detection (LOD) for both Cr(III) and Cr(VI) species was 0.3 μg L−1. Verification of the accuracy was carried out by the analysis of a standard reference material (NIST SRM 1643e “Trace elements in natural water”). The method was successfully applied to the determination of Cr(III) and Cr(VI) species in drinking water samples.  相似文献   

18.
A flow injection (FI) on-line sorption preconcentration procedure utilizing a packed column reactor and combined with electrothermal atomic absorption spectrometry (ETAAS) is proposed for the determination of low levels of Cr(VI) in water samples. Polytetrafluoroethylene (PTFE) beads packed in a mini-column is used as sorbent material. The complex formed between Cr(VI) and ammonium pyrrolidine dithiocarbamate (APDC) is sorbed on the PTFE beads, and is subsequently eluted by an air-monosegmented discrete zone of absolute ethanol (35 μl), the analyte being quantified by ETAAS.The preconcentration procedure using the proposed column significantly enhances the preconcentration efficiency as compared with the preconcentration approach incorporating an open tubular PTFE knotted reactor (KR). Comparing the two procedure for equal surface sorption area, the advantages of using a packed column are observed in terms of limit of detection, enrichment factor and retention efficiency. With a preconcentration time of 60 s, and a sample flow rate of 5.0 ml l−1, the enrichment factor (30.1) and the retention efficiency (24.1%) were doubled, yielding a detection limit (3σ) as low as 8.8 ng l−1. The sample frequency was 16.7 h−1. The concentration efficiency was 8.38 and the precision was 1.05% at 0.5 μg l−1 of Cr(VI). The proposed column has been applied successfully to the analysis of natural water and synthetic seawater. Its performance was verified by the analysis of two certified Cr(VI)-reference materials and by recovery measurements on spiked samples.  相似文献   

19.
A novel method for selective determination of Cr(III) and Cr(VI) in environmental water samples was developed based on target-induced fluorescence quenching of glutathione-stabilized gold nanoclusters (GSH-Au NCs). Fluorescent GSH-Au NCs were synthesized by a one-step approach employing GSH as reducing/protecting reagent. It was found that Cr(III) and Cr(VI) showed pH-dependent fluorescence quenching capabilities for GSH-Au NCs, and thus selective determination of Cr(III) and Cr(VI) could be achieved at different pHs. Addition of EDTA was able to effectively eliminate the interferences from other metal ions, leading to a good selectivity for this method. Under optimized conditions, Cr(III) showed a linear range of 25–3800 μg L−1 and a limit of detection (LOD) of 2.5 μg L−1. The Cr(VI) ion demonstrated a linear range of 5–500 μg L−1 and LOD of 0.5 μg L−1. The run-to-run relative standard deviations (n = 5) for Cr(III) and Cr(VI) were 3.9% and 2.8%, respectively. The recoveries of Cr(III) and Cr(VI) in environmental water samples were also satisfactory (76.3–116%). This method, with its simplicity, low cost, high selectivity and sensitivity, could be used as a promising tool for chromium analysis in environmental water samples.  相似文献   

20.
Kiptoo JK  Ngila JC  Sawula GM 《Talanta》2004,64(1):54-59
A speciation scheme involving the use of flame atomic absorption spectrometry (FAAS) and differential pulse adsorptive cathodic stripping voltammetry (DPAdCSV) techniques was applied to studies of nickel and chromium in wastewater from a nickel-chrome electroplating plant. Dimethylglyoxime (DMG) and diethylenetriaminepentaacetic acid (DTPA) were employed as complexing agents for adsorptive voltammetric determination of Ni and Cr, respectively. Cr(III) and Cr(VI) were determined by exploiting differences in their reactivity towards DTPA at HMDE. Total dissolved metal content was in the range 2906-3141 and 30.7-31.2 mg l−1 for Ni and Cr, respectively. A higher percentage of the metal was present as labile species (mean value of 67.9% for Ni and 79.8% for Cr) suggesting that strongly binding ligands are not ubiquitous in the sample. About 77.8% of Cr was found to exist in the higher oxidization state, Cr(IV). Results on effect of dilution on lability of the metal forms in the sample using DPAdCSV showed slight peak shifts to a more negative (cathodic) value by −0.036 V for Ni and −0.180 V for Cr with a dilution factor of 100, while peak intensity (cathodic current) remained fairly constant.  相似文献   