首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
The determination of 52 impurity elements in niobium materials (niobium metal, niobium oxide (V), and niobium pentaethoxide) was performed by inductively coupled plasma mass spectrometry (ICP-MS) with on-line anion exchange matrix separation as well as direct nebulization. Niobium material samples were decomposed with a mixture of hydrofluoric acid and nitric acid to prepare 10% niobium solutions. In the on-line anion exchange matrix separation/ICP-MS, the niobium and hydrofluoric acid concentrations in sample solution were adjusted to 5% and ca. 8 M, respectively. The solution was then injected into the carrier stream from the sample loop of injection valve to pass through an anion exchange resin column. In the anion exchange separation, niobium in the fluoro-complex form was adsorbed on the resin, while impurity elements were eluted. The eluted elements were introduced into ICP-MS for the determination of 25 impurity elements. On the other hand, 27 impurity elements could not be separated well from niobium matrix under the above anion exchange conditions, and then the sample solution with the niobium concentration of max. 0.2% containing internal standard elements was injected from the sample loop of injection valve directly to introduce into ICP-MS. As a result, 52 impurity elements in three kinds of niobium materials could be determined at the ng g−1 level.  相似文献   

2.
建立电感耦合等离子体-质谱(ICP-MS)法测定高纯硫粉中Si、P、V、Cr、Mn、Ni、Co、Cu、As、Zn、Zr、Cd、In、Sb、Te、Pb、Bi等17种痕量金属杂质含量的方法。样品用HClO4溶解后挥发硫基体,使样品中杂质元素得到富集,各杂质元素的方法检出限为0.1~50ng/g。方法加标回收率为83%~117%。各杂质元素均为10ng/mL的混合标准溶液平行7次测定的相对标准偏差均小于5%。该方法能够满足纯度为99.999%~99.9999%的高纯硫样品中杂质测定的需要。  相似文献   

3.
Chemical speciation (extraction of elemental information and identification of molecular environment for an analyte in a complex sample) has been a long sought after goal for analytical chemists. Recently, because of successful developments in more sensitive element-specific detectors and gentle separation schemes, which preserve the true chemical information in a real sample, routine speciation experiments are becoming a common occurrence in the scientific literature. For many reasons, the combination of capillary electrophoresis (for separation of different chemical species) with inductively coupled plasma mass spectrometry (for element and isotope specific detection) has emerged as the method of choice for these analyses. In this article the basic principles of capillary electrophoresis inductively coupled plasma mass spectrometry are discussed. Design consideration for instrument interface, anticipated difficulties with speciation experiments and applications for specific matrices and analytes are also presented in this article.  相似文献   

4.
A bonded phase capillary column containing macrocyclic polyamine, [28]ane-N6O2 functional groups was used for the electrophoretic separation of arsenic, chromium and selenium species. A simple device interfacing this capillary electrochromatography (CEC) systems to an inductively coupled plasma mass spectrometer (ICPMS) is described. The dimension of the capillary column was 160 cm×100 μm i.d. To accommodate this electrophoretic separation, an auxiliary capillary was used with nitric acid (0.05 M) as makeup liquid. With the electrokinetic method at –20 kV, 20 s and a nebulizer gas flow rate of 1 l min−1, the sample injected was analyzed with an applied potential of −20 kV. The background electrolyte buffer for the separation of CrO42−–Cr3+ was phosphate (20 mM, pH 6.5). That for HAsO42−–Ph4As+ was pyromellitate (20 mM, pH 6.0) and for SeO42−–SeO32− was acetate (20 mM, pH 6.0). The role of the buffer’s anion was also discussed. The separation efficiency of the bonded phase was compared with the bare fused silica. Concentration detection limits for these metal ions were in the low ppb range. In addition, the matrix effect of the established system with the bonded phase was found smaller than that with the bare fused silica.  相似文献   

5.
Inductively coupled plasma mass spectrometry (ICP-MS) and laser ablation ICP-MS (LA-ICP-MS) have been applied as the most important inorganic mass spectrometric techniques having multielemental capability for the characterization of solid samples in materials science. ICP-MS is used for the sensitive determination of trace and ultratrace elements in digested solutions of solid samples or of process chemicals (ultrapure water, acids and organic solutions) for the semiconductor industry with detection limits down to sub-picogram per liter levels. Whereas ICP-MS on solid samples (e.g. high-purity ceramics) sometimes requires time-consuming sample preparation for its application in materials science, and the risk of contamination is a serious drawback, a fast, direct determination of trace elements in solid materials without any sample preparation by LA-ICP-MS is possible. The detection limits for the direct analysis of solid samples by LA-ICP-MS have been determined for many elements down to the nanogram per gram range. A deterioration of detection limits was observed for elements where interferences with polyatomic ions occur. The inherent interference problem can often be solved by applying a double-focusing sector field mass spectrometer at higher mass resolution or by collision-induced reactions of polyatomic ions with a collision gas using an ICP-MS fitted with collision cell. The main problem of LA-ICP-MS is quantification if no suitable standard reference materials with a similar matrix composition are available. The calibration problem in LA-ICP-MS can be solved using on-line solution-based calibration, and different procedures, such as external calibration and standard addition, have been discussed with respect to their application in materials science. The application of isotope dilution in solution-based calibration for trace metal determination in small amounts of noble metals has been developed as a new calibration strategy. This review discusses new analytical developments and possible applications of ICP-MS and LA-ICP-MS for the quantitative determination of trace elements and in surface analysis for materials science.  相似文献   

6.
锆钛矿组成成分复杂,存在耐高温的锆、钛化合物,不易分解,且铪以类质同象进入锆矿物,导致锆钛矿中的铪含量不均,因此完全分解锆钛矿并准确测定其中含量不同的铪成为一个难题。本文建立了碳酸钠-硼砂高温熔融,以178Hf为分析同位素及50 ng/mL185Re为内标,使用电感耦合等离子体质谱法(ICP-MS)测定锆钛矿中铪的新方法,可准确锆钛矿中含量不均的铪。实验研究了锆钛矿成分及其熔融方法,结果表明碳酸钠-硼砂高温熔融效果最好,可完全溶解耐高温难分解的锆钛矿,当碳酸钠-硼砂质量配比为2:1时熔融效果最佳。电感耦合等离子体质谱法具有检出限低、灵敏度高、线性范围宽等优势,可用于测定锆钛矿中含量不均的铪,ICP-MS蠕动泵转速为45 rpm、雾化流量为1.06 L/min时雾化效率最优。在选定的实验条件下,HfO2质谱强度与其质量浓度在0.01~250 ng/mL范围内呈良好的线性关系,相关系数为0.9997,背景等效浓度为0.029 ng/mL,方法检出限为0.0032 ng/mL。按实验方法对中国国家标准物质中的HfO2进行测定,测定值与认定值一致,相对标准偏差在1.6%~3.2%之间。按实验方法对锆钛矿样品中的HfO2进行测定并进行加标回收率实验,测定结果的相对标准偏差(RSDs,n=9)在0.9~3.4%之间,加标回收率在96%~106%之间,满足国家地质矿产行业标准DZ/T 0130—2006的要求。  相似文献   

7.
A flow injection on-line sorption system was developed for the separation and preconcentration of traces of Ag, Cd, Co, Ni, Pb, U and Y from natural water samples with subsequent detection by ICP TOF MS. Simultaneous preconcentration of the analytes was achieved by complexation with the chelating reagent 1-phenyl-3-methyl-4-benzoylpyrazol-5-one immobilized on the inner walls of a (200 cm × 0.5 mm) PTFE knotted reactor. The analytes were eluted and transported to an axial ICP TOF MS system with 1% (v/v) HNO3 containing 0.3 μg l−1 of Rh as an internal standard using ultrasonic nebulization. The detection limits (3σ) varied from 0.3 ng l−1 for Y to 15.2 ng l−1 for Ni and the precision (R.S.D.) was better than 4%. Using a loading time of 90 s and a sample flow rate of 4.5 ml min−1, enhancement factors of 3-14 were obtained for the different analytes in comparison with their direct determination by ICP TOF MS with ultrasonic nebulization without preconcentration. The accuracy of the method was demonstrated by analysis of water based certified reference materials.  相似文献   

8.
This work demonstrated the feasibility of mercury speciation analysis by anion exchange chromatographic separation with inductively coupled plasma mass spectrometry detection. For the first time, by complexing with the mobile phase containing 3-mercapto-1-propanesulfonate into negatively charged complexes, fast separation of inorganic mercury (Hg2+), monomethylmercury (MeHg), ethylmercury (EtHg) and phenylmercury (PhHg) was achieved within 5 min on a 12.5-mm strong anion exchange column. The detection limits for Hg2+, MeHg, EtHg and PhHg were 0.008, 0.024, 0.029 and 0.034 μg L−1, respectively. The relative standard deviations of peak height and peak area (5.0 μg L−1 for each Hg species) were all below 3%. The determined contents of Hg2+, MeHg and total Hg in a certified reference material of fish tissue by the proposed method were in good accordance with the certified values with satisfactory recoveries. The relative errors for determining MeHg and total mercury were −2.4% and −1.2%, respectively, with an acceptable range for spike recoveries of 94–101%. Mercury speciation in 11 fish samples were then analyzed after the pretreated procedure. The mercury contents in all fish samples analyzed were found compliant with the criteria of the National Standards of China.  相似文献   

9.
电感耦合等离子体质谱技术最新进展   总被引:22,自引:0,他引:22  
李冰  杨红霞 《分析试验室》2003,22(1):94-100
对1998年以来电感耦合等离子体质谱技术(ICP-MS)的最新进展作一简要回顾。内容包括同位素比值分析、双聚焦扇形磁场高分辨ICP-MS、多接收器磁扇形等离子体质谱仪(MC-ICP-MS)、飞行时间等离子体质谱仪(ICP-TOF-MS)、“冷”等离子体及屏蔽炬技术以及动态碰撞/反应池技术等进展。  相似文献   

10.
ICP-AES 法测定硅铁中痕量元素   总被引:1,自引:0,他引:1  
艾军 《分析试验室》2001,20(5):51-53
采用电感耦合等离子原子发射光谱法测定硅铁中的痕量元素,研究了 Fe 基体对被测元素的影响,并选择了最佳工作条件.被测元素的检测限为 0 .60~76.2 ng/mL,样品加标回收率为 92%~108%,RSD(n=8)<3%.  相似文献   

11.
Xu Y  Zhou J  Wang G  Zhou J  Tao G 《Analytica chimica acta》2007,584(1):204-209
Inductively coupled plasma atomic emission spectrometry (ICP-AES) was applied to the determination of lead, arsenic, nickel and cobalt in high-purity iron oxide pigment. Samples were dissolved with hydrochloric acid and hydrogen peroxide. The digest was passed through a column, which was packed with a polymer resin containing a neutral organophosphorus extractant, tri-n-butylphosphate. Iron was sorbed selectively on the resin and the analytes of interest passed through the column, allowing the effective separation of them from the iron matrix. Conditions of separation were optimized. The detection limits (3σ) in solution were 10, 40, 7 and 5 μg L−1, and in pigment were 0.2, 0.8, 0.14 and 0.1 mg kg−1 for lead, arsenic, cobalt and nickel, respectively. The recoveries ranged from 95% to 107% when sample digests were spiked with 5 μg of the analytes of interest, and relative standard deviations (n = 6) were 1.5-17.6% for the determination of the spiked samples. The method was successfully applied to the determination of trace amounts of these elements in high-purity iron oxide pigment samples.  相似文献   

12.
An analytical method for the simultaneous determination of some trace elements (Au, Fe, Mg, Li, Sr, Zn) in human serum by inductively coupled plasma atomic emission spectrometry (ICP-AES) with flow injection is described. Physical interference caused by the change of sample viscosity is discussed. When 100 μl of serum was injected, the relevant recoveries of > 99% for Li, > 98% for Cu and Mg, > 95% for Fe were obtained for an NIST SRM with R.S.D. > 1.3% using optimized flow injection parameters. The prepared lyophilized control serum for routine analysis in clinical laboratories was analyzed and verified for the validity of the technique employed in this experiment using NIST SRM 909 as a primary reference material.  相似文献   

13.
为了准确测定锰矿冶炼烟尘中重金属元素的含量,为锰矿冶炼过程中监测和评价环境影响提供有力的数据支撑,采用HCl+HNO3+HClO4+HF消解体系对试样进行前处理,通过选用合适的内标溶液消除测定中的非质谱干扰,采用碰撞池模式和编辑校正方程消除质谱干扰,从而建立了电感耦合等离子体质谱法测定锰矿冶炼烟尘中的Cr、Ni、Cd、Tl、Pb等多种重金属元素的方法。实验结果表明,各元素标准曲线的线性相关系数均大于0.999 9,方法检出限为0.007~0.094 mg/kg,样品测定的相对标准偏差(RSD,n=11)在0.43%~4.9%,样品加标回收率为93.8%~107%。方法具有操作简便、线性范围宽、检出限低、精密度高等优点,满足锰矿冶炼烟尘中Cr、Ni、Cd、Tl、Pb等多种重金属元素同时测定的要求。  相似文献   

14.
以HNO3-H2O2为消解体系,采用微波对沉积物进行消解,建立了普里兹湾沉积物中微量元素的电感耦合等离子体质谱(ICP-MS)测定方法。从样品分析数据可以看出:8个站位10种元素总量变化范围为493.41~1481.02μg/g,总量最大值是最小值的3.00倍。元素Ba、Mn在总量中占了很大比例,V次之,而As、Mo、Ag、Cd的含量很少。大部分元素检出限可达ng/L,仅Co、Mo 2种元素的检出限稍高;各元素线性良好,相关系数r2≥0.9997。方法的RSD<5.0%,适用于普里兹湾沉积物中微量元素的定量分析。  相似文献   

15.
A novel and simple analytical procedure has been developed for the trace-level determination of lanthanides (rare-earth elements) in uranium-bearing materials by inductively coupled plasma sector-field mass spectrometry (ICP-SFMS). The method involves a selective extraction chromatographic separation of lanthanides using TRU™ resin followed by ICP-SFMS analysis. The limits of detection of the method proposed is in the low pg g−1 range, which are approximately two orders of magnitude better than that of without chemical separation. The method was validated by the measurement of reference material and applied for the analysis of uranium ore concentrates (yellow cakes) for nuclear forensic purposes, as a potential application of the methodology.  相似文献   

16.
电感耦合等离子体质谱法测定血液和精液中的硼   总被引:3,自引:0,他引:3  
采用HNO3-H2O2和氨水-甘露醇两种方法处理样品,电感耦合等离子体质谱法(ICP-MS)测定血液和精液中的硼。Be作内标补偿基体效应,并用标准加入法验证了方法的可靠性,标准加入法与外标法测定结果相吻合。在测定B的同时,还可进行Cr、Cu、Cd、Ba、Sr、Mn、Co、Tl、Li、Pb、Zn、Sc、Ti、V、As等多元素测定。两种样品处理方法的测定值呈显著正相关(r=0.99919)。方法检出限为0.11ng/mL(氨水-甘露醇法),0.06ng/mL(HNO3-H2O2)。已用于测定某硼矿区血液和精液样品中的硼。  相似文献   

17.
准确快速测定土壤中的有效钼,是评价土壤肥力的重要指标,对指导作物生产有重大意义。本文采用草酸-草酸铵溶液浸提土壤样品,待测浸提液稀释5倍后通过电感耦合等离子体质谱法在氦气模式下测定土壤中有效钼的含量,建立了土壤中有效钼高灵敏度分析的检测方法。选择103Rh为内标元素,校正仪器在测定过程中引起的信号飘移。对两种前处理方式进行比较,确定了震荡30 min、放置过夜的浸提方法浸提效果更好且更利于大批量样品的分析。使用震荡30 min、放置过夜的浸提方法对5个土壤标准物质有效钼进行前处理,其测定值均在标准值范围内;分别在无气体模式和氦气模式下比较了浓度为0mg/L、1mg/L、2mg/L、5mg/L、10mg/L、50mg/L的Mn对5ug/L 95Mo测定浓度的影响,结果表明氦气模式下的动能歧视可有效去除95Mo测定过程中的多原子离子的干扰,氦气模式测定有效钼明显优于无气体模式;分别对待测溶液稀释5倍和未稀释的内标回收率趋势进行监测,发现未稀释的样品内标回收率随着测量样品数的增多呈下降趋势,而稀释5倍对基体干扰的消除有显著效果。对5个土壤样品分别重复测定6次,其RSD均小于4.1%;线性相关系数为1.0000;方法检出限为0.0012 mg/kg。综上,该方法测定土壤有效钼结果准确,重现性好,灵敏度高,且适合大批量样品的分析。  相似文献   

18.
A new procedure for determining low levels of lead in bone tissues has been developed. After wet acid digestion in a pressurized microwave-heated system, the solution was analyzed by inductively coupled plasma multichannel-based emission spectrometry. Internal standardization using the Co 228.615 nm reference line was chosen as the optimal method to compensate for the matrix effects from the presence of calcium and nitric acid at high concentration levels. The detection limit of the procedure was 0.11 g Pb g–1 dry mass. Instrumental precision at the analytical concentration of ~10 g l–1 ranged from 6.1 to 9.4%. Precision of the sample preparation step was 5.4%. The concentration of lead in SRM 1486 (1.32±0.04 g g–1) found using the new procedure was in excellent agreement with the certified level (1.335±0.014 g g–1). Finally, the method was applied to determine the lead in various fish bone tissues, and the analytical results were found to be in good agreement with those obtained through differential pulse anodic stripping voltammetry. The method is therefore suitable for the reliable determination of lead at concentration levels of below 1 g g–1 in bone samples. Moreover, the multi-element capability of the technique allows us to simultaneously determine other major or trace elements in order to investigate inter-element correlation and to compute enrichment factors, making the proposed procedure particularly useful for investigating lead occurrence and pathways in fish bone tissues in order to find suitable biomarkers for the Antarctic marine environment.  相似文献   

19.
Inductively coupled plasma mass spectrometry analysis of trace and major elements of mussel tissues can be quickly and accurately analyzed after cleaning up the interfering fat content before the sample is digested in a microwave oven. Making use of experimental designs, the clean up procedure was achieved by the extraction of 1 g of freeze-dried tissue sample stirred with 5 ml of dichloromethane during five minutes. The microwave assisted digestion of the fat free samples was carried out with 0.2 g of tissue sample, 15 ml of 7.0% nitric acid with a power of 980 W during 18 min. The analytical method efficiency (accuracy and precision) was evaluated with a CRM: (NIST 2977, mussel tissue) and real mussel samples analyzed previously. The results confirmed the accuracy of the analysis by agreement with the previous results but the precision was significantly improved. The developed method allows operating routinely permitting to large numbers of samples to be quickly screened for trace metals.  相似文献   

20.
电感耦合等离子体质谱法测定高纯钼中12种杂质元素   总被引:1,自引:0,他引:1  
采用反应池技术消除了复合离子对Ca、Fe和Si等元素的干扰,以内标校正法直接测定了其它9种元素。优化选择了测定同位素和内标元素,考察了基体效应对测定结果的影响,建立了电感耦合等离子体质谱测定了高纯钼中12种杂质元素含量的方法。方法测定下限介于0.10~0.37μg/g之间,加标回收率为93%~105%,RSD<10%。...  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号