1.
The determination of isotope ratios in individual uranium particles is very important for nuclear safeguards. In this work, accelerator mass spectrometry (AMS), thermal ionization mass spectrometry (TIMS), and secondary ion mass spectrometry (SIMS) were applied to isotope ratio analysis of individual uranium particles and compared in terms of background, measurement accuracy, and efficiency. Several individual uranium particles (1–7 μm) from certified reference materials were used as samples. The results show that the average values of blank counting rate of 235U for AMS, FT-TIMS (FT: fission track), SEM-TIMS (SEM: scanning electron microscope), and SIMS were 7.3, 7.8, 2.7 and 2.2 cps, respectively. The relative error of 234U/235U and 234U/236U isotope ratios of the particles from U200 for AMS were within 10% and 20%, whereas the results of FT-TIMS and SIMS were within 5% and 10%, respectively. The relative error and external precision of 234U/238U and 235U/238U of the particles from U850 for the method of AMS, SEM-TIMS, and SIMS were within 10% and 5%, respectively. For 236U/238U, the average values of the relative error and external precision measured by AMS were within 5%, which measured by SEM-TIMS and SIMS were all within 10%. AMS has advantages in measuring 236U/238U. The measurement time of AMS and SEM-TIMS was shorter than that of FT-TIMS and longer than that of SIMS. It is considered that AMS and SEM-TIMS have a certain development prospect, and it is necessary to research deeply.  相似文献   

2.
The paper describes the application of laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) for the isotopic analysis of individual uranium-oxide particles. The procedure developed is suitable for the accurate measurement of 234U, 235U, 236U and 238U isotopes in single actinide particles with lateral dimensions down to 10 μm. The 235U/238U isotope ratios can be obtained with a precision of a few percent relative standard deviation using a single collector ICP-MS instrument. The precision could be improved by the use of slow ablation and by taking several LA-ICP-MS replicate spectra on the same particle investigated. For the minor isotopes use of higher mass resolution (R = 4000) was necessary in some cases to avoid spectral interferences. The technique developed offers a rapid and accurate possibility for the isotopic composition determination of uranium-containing individual particles in environmental and safeguards samples.  相似文献   

3.
An analytical method for the ultratrace and isotopic analysis of uranium in radioactive waste samples using a double-focusing sector field ICP mass spectrometer is described. In high-purity water a detection limit for uranium in the lowest fg/mL range has been achieved. Under optimum experimental conditions (235U/238U ≈ 1), the precision in 235U/238U isotopic ratio determinations has been determined as 0.07% RSD. With the isotopic standard U-020 (235U/238U = 0.0208) a precision of 0.23% RSD at the 100 pg/mL level using ultrasonic nebulization has been achieved. With 234U/238U isotopic ratios of down to 10–5, the values obtained by double-focusing sector field ICP-MS and alpha spectrometry were in agreement. Received: 27 February 1997 / Revised: 10 Juni 1997 / Accepted: 12 June 1997  相似文献   

4.
 Methodologies based on secondary ion mass spectrometry (SIMS) for isotopic measurements in nuclear forensic applications relevant to the age determination of Pu particles and isotopic composition of oxygen for geolocation assignment are described. For the age determination of Pu particles, a relative sensitivity factor (RSF) to correct for the different ionisation efficiencies of U and Pu, was obtained by analysing standard Pu materials with known ages. An RSF of 2.41±0.05 was obtained for PuO2 from measurements on samples with different Pu/U ratios. In a sample of known origin, using this RSF value, the age calculated from the 238Pu/234U and 240Pu/236U ratios agreed well with the reported age of 2.3 years. For geolocation assignment, a new approach based on the measurement of differences in the natural abundance of 18O and 16O isotopes and their ratio was developed. The instrumental mass discrimination of the 18O/16O ratio was determined using three O-isotope samples of different chemical composition. The measured precision (the standard error of 100 cycles/analysis) obtained for the oxygen isotopic measurement on the samples was typically ±1.1‰.  相似文献   

5.
Routine monitoring of urine is an effective way to detect occupational intake of radioactive material. Historically, determinations of uranium isotopic ratios have been performed by radiochemical separation followed by alpha spectrometry. With recent advancements in technology, inductively coupled plasma-mass spectrometry (ICP-MS) has become widely available for the determination of trace metals as well as radioactive nuclides with long half-lives, such as 238U in urine. Furthermore, ICP-MS measurements of 238U do not require radiochemical separation since the number of atoms in the sample is determined instead of the number of alpha particles emitted. However, this method does not provide good sensitivity for the determination of 235U due to its shorter half-life. An improved procedure using pre-concentration of uranium and determination by ICP-MS decreases the detection limit by a factor of ten or greater with only slight increase in total analysis time. The method also has the capability of accurately determining the isotopic ratio of the sample, which is very important in cases where enriched or depleted uranium is involved.  相似文献   

6.
The determination of uranium isotope ratios in individual particles is of great importance for nuclear safeguards. In the present study, an analytical technique by inductively coupled plasma mass spectrometry (ICP-MS) with a desolvation sample introduction system was applied to isotope ratio analysis of individual uranium particles. In ICP-MS analysis of individual uranium particles with diameters ranging from 0.6 to 4.2 μm in a standard reference material (NBL CRM U050), the use of the desolvation system for sample introduction improved the precision of 234U/238U and 236U/238U isotope ratios. The performance of ICP-MS with desolvation was compared with that of a conventionally used method, i.e., secondary ion mass spectrometry (SIMS). The analysis of test swipe samples taken at nuclear facilities implied that the performance of ICP-MS with desolvation was superior to that of SIMS in a viewpoint of accuracy, because the problems of agglomeration of uranium particles and molecular ion interferences by other elements could be avoided. These results indicated that ICP-MS with desolvation has an enough ability to become an effective tool for nuclear safeguards.  相似文献   

7.
The coupling of laser ablation (LA) to inductively coupled plasma-mass spectrometry (ICP-MS) enables the direct analysis of solid samples with micrometric resolution. Analysis is often restricted to relatively small samples owing to the dimensions of conventional ablation cells. Here, we assess the performance of a large rectangular, commercially-available sample cell which enables analysis over a 10.2?×?5.2 cm2 area. Comparison with the conventional cell shows a small to moderate performance decrease for the large cell resulting from the dilution of ablated particles in a larger volume with a 4–31% lower signal output and longer signal tailings. The performance of this cell is however sufficient for the determination of both major and trace elements in many kinds of samples. The applicability of the large cell LA-ICP-MS setup was demonstrated by the determination of Al, Si, Mn, Fe, Cu, Zn Pb and U in sediment core sections at a resolution of 0.6 mm. Detection limits for sediment analysis were 7 mg Al kg?1, 68 mg Si kg?1, 0.5 mg Mn kg?1, 20 mg Fe kg?1, 0.2 mg Cu kg?1, 0.3 mg Zn kg?1, 0.08 mg Pb kg?1 and 0.003 mg U kg?1. Cyclic patterns, which would have been overlooked by conventional analysis at cm resolution, were observed in analysed sediments. This study demonstrates the potential of LA-ICP-MS in environmental analysis, with the large sample cell setup offering the possibility to analyse a wider range of samples without sectioning.  相似文献   

8.
Micro-particles containing actinides are of interest for risk assessments of contaminated areas, nuclear forensic analyses, and IAEA as well as Euratom safeguards programs. For their analysis, secondary ion mass spectrometry (SIMS) has been established as the state-of-the-art standard technique. In the case of actinide mixtures within the particles, however, SIMS suffers from isobaric interferences (e.g., 238U/238Pu, 241Am/241Pu). This can be eliminated by applying resonance ionization mass spectrometry which is based on stepwise resonant excitation and ionization of atoms with laser light, followed by mass spectrometric detection of the produced ions, combining high elemental selectivity with the analysis of isotopic compositions. This paper describes the instrumental modifications for coupling a commercial time-of-flight (TOF)-SIMS apparatus with three-step resonant post-ionization of the sputtered neutrals using a high-repetition-rate (kHz) Nd:YAG laser pumped tunable titanium:sapphire laser system. Spatially resolved ion images obtained from actinide-containing particles in TOF-SIMS mode demonstrate the capability for isotopic and spatial resolution. Results from three-step resonant post-ionization of bulk Gd and Pu samples successfully demonstrate the high elemental selectivity of this process.  相似文献   

9.
Environmental swipe sampling for safeguards purpose has been used by International Atomic Energy Agency since 1997, being a powerful tool to detect undeclared materials and activities. This work describes a new methodology for swipe samples analysis based on ultrasound-assisted acid leaching and compares it with traditional total digestion bulk analysis. The proposed method requires few preparation steps, decreasing the risk of contamination, reduced amounts of reagents and a good option to extract uranium from swipe sample. In a real case study, the swipe samples were collected in a conversion plant at IPEN/CNEN, Brazil. The measurements were carried out by ICP-MS and the results showed relative error lower than 0.96 % for uranium isotopic ratios for the certified reference material (NBS U200). The uncertainties were estimated by following the ISO GUM, with a confidence level of 95 %. The uncertainties percentage for n(235U)/n(238U) ratio of the samples ranged from 2.5 to 4.3 %. The values of uranium isotopic ratio obtained for each method demonstrate the viability of using the methodology proposed in this work.  相似文献   

10.
This work describes the utilization of the laser ablation sector field inductively coupled plasma mass spectrometry (LA-SF-ICP-MS) technique for the determination of uranium isotopic composition in a highly enriched uranium sample. The measurements were performed on a continuous ablation with low energy density and defocusing, which demonstrated to be the optimum to reach the best signal stability. The measurements were improved by adjusting the following parameters: RF power, laser beam diameter, defocusing of laser beam, laser energy, laser energy density, auxiliary gas and sample gas. The 235U/238U isotope ratio with its respective uncertainty was 16.36 ± 0.15 and its precision was 1.12 % relative standard deviation. The uncertainties were estimated following the ISO GUM, with a confidence level of 95.45 % (k = 2.00). When compared the isotope abundances to the Round Robin Exercise Number 3’s average results a difference of 0.46 % has been found and when compared to supplier’s value, the difference was 0.41 %. The results presented by the measurements revealed that the LA-ICP-MS technique offers a rapid and accurate alternative to measure uranium isotope ratios without any sample preparation, since it allows carrying out the measurements straight on the sample. Moreover, it preserves the testimony—very important for safeguards and nuclear forensics purposes.  相似文献   

11.
This work explores the performance of the “Axiom”, a double focusing sector field ICP-MS (ICP-SFMS) in the determination of actinide concentration and isotopic ratio at trace level. On the actinide mass range the performances observed are characterized by high sensitivity, around 2.8·106 cps·μg−1·l, and low background, below 0.3 cps. Therefore, the absolute instrumental detection limit is approximately 0.05 fg for Pu isotopes. Furthermore, the 235U/238U ratio for a 0.5 μg·l−1 U500 isotopic standard could now be measured using the ICP-SFMS with a relative standard deviation less than 0.1%. Moreover, the accuracy of the measured ratio was demonstrated at low concentration with the target value remaining within experimental uncertainty limits. This revised version was published online in July 2006 with corrections to the Cover Date.  相似文献   

12.
 Secondary ion mass spectrometry (SIMS) was optimised for characterisation of uranium- and plutonium-containing particles in soils, swipes and forensic samples. This was done by analysing in-house produced spherical UO2-particles. Screening techniques as α-autoradiography together with SIMS analysis were employed to detect UO2-particles in a soil sample from Chernobyl. The use of SIMS was exploited for the identification of uranium- and plutonium-containing particles and for the determination of their isotopic composition. The particles collected on swipe samples were transferred to a special adhesive support for the analysis by SIMS. Particles containing highly enriched uranium with diameters up to 10 μm were also detected in a forensic sample. For the measurements of the isotopic ratios a mass resolution of 1000 was used. At this resolution flat-top peaks were obtained which greatly improve the accuracy of the measurement. The isotopic composition of the particles was measured with a typical accuracy and precision of 0.5%. Statistically meaningful results can be obtained, for instance, from a specimen containing as few as 1010 atoms/μm3 of uranium in particles of UO2 weighing a few picograms.  相似文献   

13.
The application of scanning electron microscopy (SEM) and secondary ion mass spectrometry (SIMS) for characterization of mixed plutonium and uranium particles from nuclear weapons material is presented. The particles originated from the so-called Thule accident in Greenland in 1968. Morphological properties have been studied by SEM and two groups were identified: a "popcorn" structure and a spongy structure. The same technique, coupled with an energy-dispersive X-ray (EDX) spectrometer, showed a heterogeneous composition of Pu and U in the surface layers of the particles. The SIMS depth profiles revealed a varying isotopic composition indicating a heterogeneous mixture of Pu and U in the original nuclear weapons material itself. The depth distributions agree with synchrotron-radiation-based mu-XRF (X-ray fluorescence microprobe) measurements on the particle (Eriksson, M., Wegryzynek, D., Simon, R., & Chinea-Cano, E., in prep.) when a SIMS relative sensitivity factor for Pu to U of 6 is assumed. Different SIMS identified isotopic ratio groups are presented, and the influence of interferences in the Pu and U mass range are estimated. The study found that the materials are a mixture of highly enriched 235U (235U:238U ratio from 0.96 to 1.4) and so-called weapons grade Pu (240Pu:239Pu ratio from 0.028 to 0.059) and confirms earlier work reported in the literature.  相似文献   

14.
As a result of the accident at the Chernobyl nuclear power plant (NPP) the environment was contaminated with spent nuclear fuel. The 236U isotope was used in this study to monitor the spent uranium from nuclear fallout in soil samples collected in the vicinity of the Chernobyl NPP. Nuclear track radiography was applied for the identification and extraction of hot radioactive particles from soil samples. A rapid and sensitive analytical procedure was developed for uranium isotopic ratio measurement in environmental samples based on double-focusing inductively coupled plasma mass spectrometry (DF–ICP–MS) with a MicroMist nebulizer and a direct injection high-efficiency nebulizer (DIHEN). The performance of the DF–ICP–MS with a quartz DIHEN and plasma shielded torch was studied. Overall detection efficiencies of 4×10–4 and 10–3 counts per atom were achieved for 238U in DF–ICP–QMS with the MicroMist nebulizer and DIHEN, respectively. The rate of formation of uranium hydride ions UH+/U+ was 1.2×10–4 and 1.4×10–4, respectively. The precision of short-term measurements of uranium isotopic ratios (n = 5) in 1 μg L–1 NBS U-020 standard solution was 0.11% (238U/235U) and 1.4% (236U/238U) using a MicroMist nebulizer and 0.25% (235U/238U) and 1.9% (236U/238U) using a DIHEN. The isotopic composition of all investigated Chernobyl soil samples differed from those of natural uranium; i.e. in these samples the 236U/238U ratio ranged from 10–5 to 10–3. Results obtained with ICP–MS, α- and γ-spectrometry showed differences in the migration properties of spent uranium, plutonium, and americium. The isotopic ratio of uranium was also measured in hot particles extracted from soil samples.  相似文献   

15.
The isotopic composition of single uranium and plutonium particles was measured with an inductively coupled plasma mass spectrometer (ICP-MS) and a thermal ionization mass spectrometer (TIMS). Particles deposited on a carbon planchet were first analyzed with an energy dispersive X-ray spectrometer (EDX) attached to a scanning electron microscope (SEM) and then transferred on to a silicon wafer using a manipulator. The particle on the silicon wafer was dissolved with nitric acid and the isotopic ratios of U and Pu were measured with ICP-MS and TIMS. The results obtained by both methods for particles of certified reference materials showed good agreement with the certified values within the expected uncertainty. The measurement uncertainties obtained in this study were similar for both mass spectrometric methods. This study was performed to establish the method of particle analysis with SEM, EDX, the particle manipulation and chemical preparation technique, and the measurement of isotopic ratios of U and Pu in a single particle by mass spectrometry.  相似文献   

16.
Elemental and isotopic determination of americium and curium in spent nuclear fuels is necessary to validate neutronic calculation codes and for nuclear waste disposal purposes. Prior to mass spectrometric analysis, it is mandatory to perform separations in order to eliminate isobaric interferences between U, Pu, Am and Cm. In the spent fuels samples analyzed, a separation of U and Pu has been first realized with an anion-exchange resin. Then a rapid Am/Cm separation has been developed by high-performance liquid chromatography (HPLC) with an on-line detection using the Am and Cm α-emission. The influence of the different parameters on the chromatographic separation are described and discussed. Inductively coupled plasma mass spectrometry (ICP-MS) and thermal-ionization mass spectrometry (TIMS) have been used to measure the isotopic composition of U, Am and Cm and to determine the 241Am/238U and 244Cm/238U ratios with the double spike isotope dilution method. The measurement procedures and the accuracy and precision of the results obtained with a quadrupole ICP-MS on different spent fuels samples are discussed and compared with those obtained by TIMS, used as a reference technique. Received: 30 November 1998 / Revised: 8 January 1999 / Accepted: 12 January 1999  相似文献   

17.
Elemental and isotopic determination of americium and curium in spent nuclear fuels is necessary to validate neutronic calculation codes and for nuclear waste disposal purposes. Prior to mass spectrometric analysis, it is mandatory to perform separations in order to eliminate isobaric interferences between U, Pu, Am and Cm. In the spent fuels samples analyzed, a separation of U and Pu has been first realized with an anion-exchange resin. Then a rapid Am/Cm separation has been developed by high-performance liquid chromatography (HPLC) with an on-line detection using the Am and Cm α-emission. The influence of the different parameters on the chromatographic separation are described and discussed. Inductively coupled plasma mass spectrometry (ICP-MS) and thermal-ionization mass spectrometry (TIMS) have been used to measure the isotopic composition of U, Am and Cm and to determine the 241Am/238U and 244Cm/238U ratios with the double spike isotope dilution method. The measurement procedures and the accuracy and precision of the results obtained with a quadrupole ICP-MS on different spent fuels samples are discussed and compared with those obtained by TIMS, used as a reference technique. Received: 30 November 1998 / Revised: 8 January 1999 / Accepted: 12 January 1999  相似文献   

18.
A fission track technique was used as a sample preparation method for subsequent isotope abundance ratio analysis of individual uranium containing particles with secondary ion mass spectrometry (SIMS) to measure the particles with higher enriched uranium efficiently. A polycarbonate film containing particles was irradiated with thermal neutrons and etched with 6 M NaOH solution. Each uranium containing particle was then identified by observing fission tracks created and a portion of the film having a uranium containing particle was cut out and put onto a glassy carbon planchet. The polycarbonate film, which gave the increases of background signals on the uranium mass region in SIMS analysis, was removed by plasma ashing with 200 W for 20 min. In the analysis of swipe samples having particles containing natural (NBL CRM 950a) or low enriched uranium (NBL CRM U100) with the fission track–SIMS method, uranium isotope abundance ratios were successfully determined. This method was then applied to the analysis of a real inspection swipe sample taken at a nuclear facility. As a consequence, the range of 235U/238U isotope abundance ratio between 0.0276 and 0.0438 was obtained, which was higher than that measured by SIMS without using a fission track technique (0.0225 and 0.0341). This indicates that the fission track–SIMS method is a powerful tool to identify the particle with higher enriched uranium in environmental samples efficiently.  相似文献   

19.
The spatial distribution of radiation within trinitite thin sections have been mapped using alpha track radiography and beta autoradiography in combination with optical microscopy and scanning electron microscopy. Alpha and beta maps have identified areas of higher activity, and these are concentrated predominantly within the surficial glassy component of trinitite. Laser ablation-inductively coupled plasma mass spectrometry (LA-ICP-MS) analyses conducted at high spatial resolution yield weighted average 235U/238U and 240Pu/239Pu ratios of 0.00718 ± 0.00018 (2σ) and 0.0208 ± 0.0012 (2σ), respectively, and also reveal the presence of some fission (137Cs) and activation products (152,154Eu). The LA-ICP-MS results indicate positive correlations between Pu ion signal intensities and abundances of Fe, Ca, U and 137Cs. These trends suggest that Pu in trinitite is associated with remnants of certain chemical components from the device and surrounding Trinity test-related structures at ground zero. In contrast, negative correlations between Pu ion signals and SiO2 and K2O contents were observed within the glassy matrix of trinitite. This LA-ICP-MS result was corroborated by combined back-scattered electron imaging and alpha radiography, and indicates that Pu was not incorporated into unmelted crystalline grains of precursor minerals (i.e., quartz-SiO2 and K-feldspar-KAlSi3O8) present within the desert sand at the Trinity site. The results from this study indicate that the device-related radionuclides were preferentially incorporated into the glassy matrix in trinitite.  相似文献   

20.
We compare the analytical performance of a modern quadrupole-based ICP-MS (“X-Series”, Thermo-Electron, Winsford, UK) with a single-collector double-focusing sector-field ICP-MS (“Axiom”, VG Elemental, Winsford, UK) for uranium isotopic measurements in environmental samples. We focus on the precision and accuracy obtained with both instruments for the 235U/238U isotopic ratios and on the abundance sensitivity that is a key parameter for low 236U/238U isotopic ratios measurements. We observe that isotopic measurements are more precise accurate with the “X-Series” than with the “Axiom”. Besides, we demonstrate that the “Axiom’s” higher abundance sensitivity limits its capability to measure 236U/238U ratio below a few ppm.  相似文献   