共查询到20条相似文献,搜索用时 15 毫秒
1.
2.
A simple and sensitive procedure for the measurement of N-methylisoquinolinium ion (NMIQ+), a putative neurotoxin, was devised using high-performance liquid chromatography (HPLC) with fluorescence detection. Separation of NMIQ+ was carried out by gel filtration and reversed-phase HPLC on a column of hydrophilic polymer gels (Asahipak GS-302H). The method was sensitive enough to measure 50 fmol of NMIQ+. Uptake of NMIQ+ into rat striatal slices was confirmed by this method. 相似文献
3.
4.
A robust, routinely manageable and sensitive RP-HPLC method combined with UV (270 nm) and ESI-MS detection was established for the determination of abundant pertinent phenolic compounds (phytochemicals) from various biological matrices. Phytochemicals were extracted by aqueous methanol (80%), extracts were analysed without further purification. Baseline separation was achieved within 30 min for 19 phytochemicals and excellent sensitivity (6-42 pmol at S/N = 3) was obtained. The identity of the phytochemicals was confirmed with standard compounds and with LC-MS. The repeatabilities for the majority of the phytochemicals ranged between 3% and 6%. The practicability of the method was shown in complex biological matrices by analysing onion and soybean extracts. This generally applicable technique may serve as a valuable tool for a rapid screening and a specific measurement of phytochemicals in food extracts and biological fluids and serve as analytical instrument for future biochemical and physiological studies. 相似文献
5.
J Moncrieff 《Journal of chromatography. A》1992,577(1):185-189
The author describes a method of using reversed-phase high-performance liquid chromatography with fluorimetric detection for the assay of diclofenac sodium in serum. The method is sensitive down to 20 ng/ml (250-microliters loop). Elution is at pH 6.2 with methanol in 0.05 M phosphate buffer (43:57, v/v) on a 25-cm Spherisorb S5 ODS2 column. Detection is at an excitation wavelength of 282 nm and an emission wavelength of 365 nm. Serum sample size is 100 microliters. Sample protein, to which diclofenac is highly bound, is first denatured by heat and then with methanol to release the diclofenac prior to centrifugation and injection of 100 microliters (or 250 microliters) of the clear supernatant. Harmol, with similar fluorescence and polarity characteristics to diclofenac, is a satisfactory internal standard. At the 1 micrograms/ml level intra-sample reproducibility is better than 2%, whilst inter-sample reproducibility is 4.6%. Detector response is linear from 40 ng/ml to 20 micrograms/ml (100-microliters loop). 相似文献
6.
Determination of clindamycin in plasma or serum by high-performance liquid chromatography with ultraviolet detection 总被引:1,自引:0,他引:1
G La Follette J Gambertoglio J A White D W Knuth E T Lin 《Journal of chromatography. A》1988,431(2):379-388
A simple, sensitive high-performance liquid chromatographic assay for the determination of clindamycin in human plasma or serum has long been hampered by inability to separate it from endogenous compounds. We describe here such an assay. Proteins from a 200-microliters sample were precipitated by addition of acetonitrile containing the internal standard, triazolam. The sample was then vortex-mixed and centrifuged at approximately 3000 g for 10 min. The supernatant was evaporated to about 250 microliters under nitrogen, and 10-30 microliters were analyzed using an autoinjector. An octadecylsilane column with acetonitrile-water-phosphoric acid-tetramethylammonium chloride as mobile phase and ultraviolet detection at 198 nm provided a reproducibly quantifiable peak corresponding to 0.17 micrograms/ml. Retention times for clindamycin and triazolam averaged 8 and 11.8 min, respectively. Replicate standard curves run over a 36-h period showed no loss of integrity; r2 values generally exceeded 0.999. The method has successfully been applied to the analysis of samples taken up to 12 h after administration of intravenous infusions of 600-1200 mg in healthy volunteers. 相似文献
7.
Determination of camptothecin in biological fluids using reversed-phase high-performance liquid chromatography with fluorescence detection 总被引:1,自引:0,他引:1
Camptothecin, a plant alkaloid with antitumor activity, is a potent and rapidly acting inhibitor of DNA synthesis. The objective of this study was to develop a sensitive high-performance liquid chromatographic (HPLC) method for the detection and estimation of the camptothecin concentration in biological fluids. Using HPLC coupled with fluorescence detection, at an excitation wavelength of 370 nm and an emission wavelength of 434 nm, we found that the lower limits of detection for camptothecin in aqueous, plasma and urine samples were 0.5, 1 and 10 ng/ml, respectively. The ideal mobile phase used was methanol-10 mM potassium phosphate (75:25, v/v, pH 4.0). To determine the utilization of the method in a biological system, we studied the pharmacokinetics of camptothecin in mice. Elimination of camptothecin from mice blood was triphasic and followed first-order kinetics. The half-life of camptothecin in mouse blood was 25.7 min. Our studies indicate that HPLC with fluorescence detection for the determination of camptothecin in different media is a simple, rapid, sensitive and reproducible method. 相似文献
8.
9.
A highly sensitive method for the determination of tetracycline antibiotics (TCs) using reversed-phase high-performance liquid chromatography with fluorescence detection is presented. This method was based on the use of disodium ethylenediaminetetraacetate (EDTA) and calcium chloride as fluorescence-increasing reagents in the mobile phase. The concentrations of each reagent in the mobile phase greatly influenced the fluorescence intensity of TCs. When the concentration of EDTA and calcium chloride were 25 and 35 mM, respectively, and the pH of the mobile phase was 6.5, the maximum fluorescence intensity was obtained. The column temperature hardly influenced the fluorescence intensity. At 3.75 ng of TCs injected, the precision (relative standard deviation) ranged from 1.12 to 2.20%. In the range 0.075-37.5 ng for tetracycline and oxytetracycline and 0.225-37.5 ng for chlortetracycline, a linear response was observed. The detection limits of this method were 49-190 pg for three different TCs. The proposed method was applied to the determination of one of the TCs in pharmaceuticals by the internal standard method using other TCs as internal standards and was also applied to determination of TCs added to fish tissue. 相似文献
10.
I Svagrová K Stulík V Pacáková P Caliceti F M Veronese 《Journal of chromatography. A》1991,563(1):95-102
Narciclasine was determined in the blood of mice by reversed-phase high-performance liquid chromatography, using a C18 stationary phase and a mobile phase of methanol-0.025 M potassium dihydrogen phosphate (50:50, v/v) of pH 5.5. Amperometric detection at a carbon fibre array working electrode held at +1.8 V (Ag/AgCl) permitted determination down to concentrations of 10 and 15.4 ng ml-1 (at a signal-to-noise ratio of 2) in aqueous solution and in serum, respectively. Fluorescence detection (excitation and emission wavelengths of 360 and 480 nm, respectively) exhibited somewhat poorer sensitivities for aqueous and serum samples: the respective limits of detection were 25 and 32 ng ml-1 at a signal-to-noise ratio of 2. Both the amperometric and the fluorescence detection were free from interference from blood components, but the fluorescence measurement required a post-column pH adjustment. UV photometric detection at 254 nm exhibited detection limits of 15 and 65 ng ml-1 in aqueous samples and in serum, respectively, and suffered from interferences from blood components that strongly absorbed in the ultraviolet region. All three detection techniques exhibited good linearity and precision. 相似文献
11.
A liquid chromatography procedure is reported for determining phenylalanine in small volumes of serum. A 10-microliter volume of serum was deproteinized with ethanol and an aliquot was derivatized with dansyl chloride reagent. The dansylated phenylalanine and the norleucine internal standard were separated using reversed-phase chromatography and measured with a fluorescence detector. Linearity was excellent over the range 50-800 mg/l. Within-run precision was better than 4%. Total analysis time including chromatography was approximately 40 min. As little as 300 pg of dansylated phenylalanine was detected. 相似文献
12.
13.
14.
M P Richards 《Journal of chromatography. A》1989,482(1):87-97
Reversed-phase high-performance liquid chromatography (RP-HPLC) was used to separate metallothionein (MT) isoforms and on-line atomic absorption spectrophotometric (AAS) detection was used to quantitatively determine their metal content. With this coupled system (HPLC-AAS), it was possible to determine the zinc, cadmium and copper content of individual horse kidney MT isoforms. When rabbit liver MT and the purified isoforms (MT-1 and MT-2) were subjected to RP-HPLC and the zinc-containing peaks of the MT sample to MT-1 or MT-2. HPLC-AAS was used to identify zinc-induced MT in heat-treated cytosol from turkey hen liver, thereby demonstrating its application to the analysis of crude tissue extracts. A standard curve was established using turkey liver MT for the quantitative determination of the zinc content of MT isoforms. There was excellent linear correlation between the micrograms of zinc bound to MT injected onto the column (ranging from 0.34 to 3.43 micrograms of MT-bond zinc) and the integrated peak area of the atomic absorbance for zinc. Using this standard curve, it was possible to quantitate the amount of MT-bound zinc in cytosol extracts of cultured turkey embryo hepatocytes exposed to varying levels of supplemental zinc in the culture medium. 相似文献
15.
16.
P P Rop F Grimaldi M Bresson J Spinazzola J Quicke A Viala 《Journal of chromatography. A》1992,573(1):87-92
Dextromoramide was determined in plasma and whole blood after solid-phase isolation by high-performance liquid chromatography using dextropropoxyphene as internal standard and ultraviolet detection at 215 nm. Owing to its good selectivity, sensitivity and reproducibility, the technique is available for forensic toxicology purposes as well as for clinical pharmacology. The concentrations of dextromoramide were determined in three cancer patients receiving intravenous treatment with one to three 5-mg daily doses. On the fourth day the plasma level was 13.85 +/- 3.27 ng ml-1 just before the first daily dose and 84.28 +/- 12.60 ng ml-1 30 min after dosing. The whole blood concentration, determined in one of the patients, was undetectable just before the dose and was 76 ng ml-1 30 min after dosing. 相似文献
17.
A high-performance liquid chromatographic method for the determination of the histamine H1-receptor antagonist cetirizine in human urine was developed. Cetirizine and the internal standard are extracted from acidified (pH 5) urine (0.5 ml) into chloroform and the organic layer is evaporated to dryness. The residue is chromatographed on a Spherisorb 5ODS-2 column using Pic A (5 mM aqueous tetrabutylammonium phosphate)-methanol-tetrahydrofuran (33:65:2, v/v) as the mobile phase with ultraviolet detection (230 nm). The calibration graph is linear from 0.1 to 10 micrograms/ml and using 0.5 ml of urine the detection limit is 20 ng/ml. The within-run relative standard deviation is less than 6% and the accuracy is within 10% of the theoretical value at concentrations between 0.1 and 10 micrograms/ml in urine. There is a good correlation (r = 0.99606) with a previously described capillary gas chromatographic assay. 相似文献
18.
P Volin 《Journal of chromatography. A》1992,584(2):147-155
A rapid high-performance liquid chromatographic (HPLC) method for the simultaneous determination of cortisol and cortisone in a single extract of 1 ml of serum is described. The method employs meprednisone as the internal standard. The steroids were analysed isocratically by reversed-phase HPLC with an octadecylsilane-bonded (ODS) column using ultraviolet detection. The matrix effect was reduced by lowering the sample pH by adding glacial acetic acid to the sera. The samples were then filtered through regenerated cellulose membranes at 4 degrees C and extracted with diethyl ether. The dried eluates were redissolved in the mobile phase and injected into the column. The detection limit of the assay for both steroids was 500 ng/l. Cortisol was determined in twenty serum samples by both HPLC and radioimmunoassay (RIA). The results were similar. Interference by other steroids and certain steroid analogue drugs was also studied. The HPLC method yielded no cross-reactivity between the different steroids as may occur with the RIA technique. The HPLC method was technically easy to perform and it allowed us to quantify both cortisol and cortisone in a single serum extract with high specificity. 相似文献
19.
D M Burger H Rosing R van Gijn P L Meenhorst O van Tellingen J H Beijnen 《Journal of chromatography. A》1992,584(2):239-247
A sensitive high-performance liquid chromatographic assay has been developed to determine the levels of a new antiretroviral agent, stavudine (2',3'-didehydro-3'-deoxythymidine, d4T), in human plasma. Didanosine (2',3'-dideoxyinosine, ddI) was used as the internal standard. The very selective sample pretreatment involved solid-phase extraction using silica gel columns. Chromatography was carried out on a mu Bondapak phenyl column, using a mobile phase of 0.005 M phosphate buffer (pH 6.8)-methanol (90:10, v/v) and ultraviolet detection at 265 nm. The method has been validated, and stability tests under various conditions have been performed. The detection limit is 10 ng/ml (using 500-microliters human plasma samples). The bioanalytical assay has been used in a single pharmacokinetic experiment in a rat to investigate the applicability of the method in vivo. 相似文献
20.
A sensitive high-performance liquid chromatographic method for a routine assay of nadolol in serum is described. Serum samples spiked with atenolol (internal standard) were extracted with diethyl ether. After centrifugation, the organic layer was evaporated to dryness. The residue was redissolved in the mobile phase and injected onto an octadecyl silica column (150 mm x 4.6 mm I.D.). The mobile phase was 0.05 M ammonium acetate (pH 4.5)-acetonitrile (85:15, v/v). Fluorometric detection (excitation 230 nm, emission 300 nm) was used. The minimum detectable level of nadolol in serum was 1 ng/ml. 相似文献