首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 625 毫秒
1.
Simultaneous kinetic‐spectrophotometric determination of a ternary mixture of hydrazine (HZ) and its derivatives by principal component regression (PCR) and partial least squares (PLS) calibration is described. The methods were based on the difference observed in the reduction rate of iron(III) with HZ, thiosemicarbazide (TSCZ) and phenylhydrazine (PHZ) in the presence of 2,2′‐bipyridine (Bpy). The colored complex of [Fe(Bpy)3]2+ was formed in sodium dodecyl sulfate (SDS) as micellar media, and then monitored at 520 nm. The results showed that simultaneous determination of HZ, TSCZ and PHZ could be performed in their concentration ranges of 1.0–70.0, 0.2–6.0 and 0.1–10.0 μg mL?1, respectively. The root mean squares errors of prediction (RMSEP) of HZ, TSCZ and PHZ were 0.719, 0.164 and 0.105 (for PLS) 0.788, 0.166 and 0.993 (for PCR), respectively. Both methods (PCR and PLS) were validated using a set of synthetic sample mixtures and then applied for simultaneous determination of HZ, TSCZ and PHZ in water samples.  相似文献   

2.
A specific spectrophotometric method was developed for simultaneous determination of paracetamol (PCT) and p‐aminophenol (PAP) in water samples without prior separation steps. The method is based on the mean centering of ratio kinetic profiles. Paracetamol and P‐aminophenol react with Fe(III)/hexacyanoferrate(III) complex and result in the formation of colored complex, i.e. Prussian Blue. The differences in the rate of reaction of PCT and PAP with reagents make their simultaneous determination feasible by using mean centering of ratio kinetic profiles. The experimental parameters, such as reagent concentrations and pH were optimized for getting results with minimum errors. The analytical characteristics of the method such as detection limit, accuracy, precision, relative standard deviation (R.S.D.) and relative standard error (R.S.E.) for the simultaneous determination of binary mixtures of p‐aminophenol and acetaminophen were calculated. The results show that the method was capable of simultaneous determination of 0.5–21.0 μg mL−1 and 0.1–15.0 μg mL−1 of PCT and PAP, respectively. The proposed method was successfully applied to the simultaneous determination of paracetamol and p‐aminophenol in several pharmaceutical products and synthetics mixtures.  相似文献   

3.
Pyrocatechol violet (PCV), aluminon, eriochrome cyanine R (ECR) and eriochrome cyanine R with cetyltrimethylammonium bromide (ECR/CTA) are compared as chromogenic reagents for the flow-injection determination of aluminium in water. The detection limit of the ECR/CTA method is 1 μg Al 1?1. The detection limits of the PCV and ECR methods are 5 μg Al 1?1. The aluminon method is the least sensitive, with a detection limit of 50 μg Al l?1. Interference from iron, fluoride, phosphate and the acidity of the sample were investigated. The interference from iron is suppressed by hydroxylammonium chloride/1,10-phenanthroline in the PCV and ECR/CTA methods at concentrations less than 5 mg Fe l?1. In the ECR and aluminon methods, iron <5 mg l?1) is masked by ascorbic acid. Fluoride at <0.2 mg l?1 can be tolerated in all methods. The aluminon method can tolerate up to about 500 mg l?1 in the three other methods. All methods are sensitive to changes in acidity of the samples; the acidity should be 0.08–0.12 M HCl.  相似文献   

4.
《Analytical letters》2012,45(8):1987-1996
Abstract

Derivative spectrometry is applied to a spectrophotometric determination of iron with EDDHA. the effect of amount of reagent, acidity, time and temperature have also been studied. the interval of application of the method is increased to 0.16–15.36 μg Fe(III) mL?1. the reproducibility, precision and potential interferents have been investigated. the interferences due to chlorate, wolframate, molybdate, permanganate, cyanide, cromate, Cu(II), Be(II), Ce(III), Al(III), Hg(II), Sn(II) and Zn(II) are reduced in this new procedure.  相似文献   

5.
Two spectrophotometric methods, a photochemical and a non-photochemical, for the determination of ascorbic acid in soft drinks and beer using a flow-injection system are proposed. The non-photochemical method is based on the redox reaction that takes place between ascorbic acid and Fe(III), yielding dehydroascorbic acid and Fe(II). Fe(II) reacts with 1,10-phenantroline, originating the reddish orange Fe(phen)3 2+ complex (ferroin). This complex is spectrophotometrically monitored at 512 nm, and the signal is directly related to the concentration of ascorbic acid in the sample. The photochemical method has the same basis, nevertheless, uses the irradiation with visible light to enhance the redox reaction and so achieve higher sensitivities in the analysis. The non-photochemical method shows a linear range between 5 and 80 μg mL?1, with a relative standard deviation of 1.6% (n = 11), a detection limit of 2.7 μg mL?1 and a sample throughput of ¶60 samples h?1. The photochemical method shows a linear range between 1 and 80 μg mL?1, with a relative standard deviation of 1.0% (n = 11), a detection limit of 0.5 μg mL?1 and a sample throughput of 40 samples h?1.  相似文献   

6.
A new disposable sensitive voltammetric sensor for the determination of Fe(III) based on a graphene (G) and piroxicam (Pir) modified screen printed carbon electrode (Pir/G/SPCE) has been developed. The developed method is based on accumulation of Fe(III) on the surface of the prepared sensor strip, formation a complex with Pir and subsequent reduction the adsorbed chelated Fe(III) at ?0.03 V (vs. Ag/AgCl) coupled with the catalytic enhancement of bromate. Characterizations of the modified electrode surface were performed by field emission scanning electron microscopy (FE‐SEM), energy dispersive X‐ray spectroscopy (EDX) and electrochemical impedance spectroscopy (EIS). Electrochemical behavior of the modified SPCEs was investigated by cyclic voltammetry (CV) and differential pulse voltammetry (DPV). Under the optimum conditions, the catalytic voltammetric method exhibited linear calibration plot in the concentration ranges of 1–100 ng mL?1 and 100–3500 ng mL?1 Fe(III) with a limit of detection of 0.3 ng mL?1. The sensor strip displayed good reproducibility with 1.7 % relative standard deviation (RSD%). The developed method was successfully applied for the determination of iron in food samples such as vegetables, fruit, and cereal.  相似文献   

7.
Simultaneous determination of hydrazine (HZ) and thiosemicarbazide (TSC) by partial least squares (PLS) and principle component regression (PCR) was carried out based on kinetic data of novel potentiometry. The rate of chloride ion production in reaction of HZ and TSC with N‐chlorosuccinimide (NCS) was monitored by a chloride ion‐selective electrode. The experimental dada shows not only the good ability of ion‐selective electrodes (ISEs) as detectors for the direct determination of chloride ions but also for simultaneous kinetic‐potentiometric analysis using chemometrics methods. The methods are based on the difference observed in the production rate of chloride ions. The results show that simultaneous determination of HZ and TSC can be performed in their concentration ranges of 0.7‐20.0 and 0.5‐20.0 μg mL?1, respectively. The total relative standard error for applying PLS and PCR methods to 9 synthetic samples in the concentration ranges of 0.8‐10 μg mL?1 of TSC and 1.0‐12.0 μg mL?1 of HZ was 4.62 and 4.98, respectively. The effects of certain foreign ions upon the reaction rate were determined for the assessment of the selectivity of the method. Both methods (PLS and PCR) were validated using a set of synthetic sample mixtures and then applied for simultaneous determination of HZ and TSC in water samples.  相似文献   

8.
《Analytical letters》2012,45(11):2525-2529
Abstract

A simple post column reaction detection system for fluoride is presented using the decolorization of the zirconyl xylenol orange complex. A 3[sgrave] detection limit of 0.05 μg F? mL?1 was achieved with a linear calibration function up to 10 μg F? mL?1. The methodology is suitable for the determination of F? in potable water and some interferences studies were conducted with common cations namely Ca, Mg, Al and Fe(III).  相似文献   

9.
《Analytical letters》2012,45(4):797-807
Abstract

A fast and simple flow injection chemiluminescence method for the determination of trace amounts of tetracyclines is proposed based on the chemiluminescence of the KMnO4 - TCs redox reaction in acidic medium in the presence of a sensitizer, OP. The response to the concentration of tetracyclines is linear in the range of 1.00 to 1000 μg mL?1 with a relative standard deviation < 2.3 % for determination of 50.0 μg mL?1 of each antibiotic (n = 11). The detection limits for tetracycline, oxytetracycline and chlortetracycline are 0.40, 0.52 and 0.60 μg mL?1, respectively. The recommended method is suitable for automatic and continuous analysis and has been successfully tested for determination of tetracyclines in commercial formulations. The chemiluminescence intensity was found to be remarkably enhanced when in the presence of OP micellar system; possible reasons for this observed micellar induced enhanced chemiluminescence is given.  相似文献   

10.
A simple and reliable method for simultaneous spectrophotometric determination of iron(II) and cobalt(II) has been established. The method is based on complex formation with 1‐(2‐pyridylazo)‐2‐naphtol (PAN) in a micellar medium. Despite a spectral overlap, Fe2+ and Co2+ have been simultaneously determined with chemometric approaches involving principal component artificial neural network (PC‐ANN), principal component regression (PCR) and partial least squares (PLS). Various synthetic mixtures of iron and cobalt were assessed and the results obtained by the applications of these chemometric approaches were evaluated and compared. It was found that the PC‐ANN method afforded relatively better precision than that of PCR or PLS. The proposed method permits detection limits of 0.05 and 0.07 ng mL?1 for Co and Fe, respectively. The influences of pH, ligand amount, solvent percentage and time on the absorbance were also investigated. The proposed method was also applied satisfactorily for the determination of Fe(II) and Co(II) in real and synthetic samples.  相似文献   

11.
A novel generic reverse phase high performance liquid chromatography (RP‐HPLC) method is developed and validated for simultaneous determination of seven pharmaceutically active ingredients, namely, acetaminophen, dextromethorphan, doxylamine, phenylephrine, guaifenesin, caffeine and aspirin. All seven ingredients were quantified in soft gel, syrup and tablet formulations of the over‐the‐counter US‐marketed products, as per the guidelines of the International Conference on Harmonization. The separation was achieved in a 16 min run time on an Agilent Zorbax Phenyl column using a gradient method with two mobile phases. Mobile phase A was 0.15% trifluoro acetic acid in purified water and while mobile phase B was a mixture of acetonitrile and methanol (750:250 v/v) with 0.02% trifluoro acetic acid. The flow rate was 1.0 mL min?1 and injection volume was 10 μL. Detection was performed at 280 nm using a photodiode array detector. As part of the method validation, specificity, linearity, precision and recovery parameters were verified. The concentration and area relationships were linear (R2 > 0.999), over the concentration ranges 20–120 μg mL?1 for acetaminophen, 75–450 μg mL?1 for dextromethorphan, 31.25–187.5 μg mL?1 for doxylamine, 25–150 μg mL?1 for phenylephrine, 25–150 μg mL?1 for aspirin, 6.5–39 μg mL?1 for caffeine and 12–72 μg mL?1 for guaifenesin. The relative standard deviations for precision and intermediate precision were <1.5%. The proposed RP‐HPLC generic method is applicable for routine analysis of cold and cough over‐the‐counter products.  相似文献   

12.
A multivariate calibration model (PLS) was developed for the simultaneous spectrophotometric determination of Al(III) and Fe(III) in post-hemodialysis fluids with pyrocathecol violet (PCV) as chromogenic reagent. The analytes build stable complexes with PCV in presence of hexamine buffered medium at pH 6.1. The complexes show overlapped absorption bands in the spectral range of 220-800 nm so that absorptions of 580 wavelengths were necessary for the calibrations. Determinations of Al(III) and Fe(III) were done without masking agents. The best calibration model was obtained by using PLS-1 regression with three components after data mean centering. The spectrophotometric method applied to assay the analytes in real post-hemodialysis samples containing no desferrioxamine B presented good agreement with voltammetric measurements used as reference. Concentrations ranging from 0.20 to 0.60 mg L−1 for Al(III) and for Fe(III) were determined in real samples. The multivariate detection limits for Al(III) and Fe(III) were 0.044 and 0.052 mg L−1, respectively, and the calculated values of sensitivity were 6.33 for Al(III) and 3.44 for Fe(III). The proposed method showed to be straightforward and useful to follow the hemodialysis progress for patients under treatment. Interferents were also investigated.  相似文献   

13.
The objective of this work is to develop and validate spectrophotometric method for the determination of piroxicam in commercial dosage forms. The method is based on the chelation of the drug with Fe(III) to form pink coloured metal chelate at room temperature which absorbs maximally at 504 nm. Beer's law is obeyed over the concentration range of 8–160 μg mL?1 (A = 1.07 × 10?3 + 7.75 × 10?3 C). Under the optimized experimental conditions, proposed method is validated as per the International Conference on Harmonisation guidelines. The limits of detection and quantitation for the proposed method are 0.775 and 2.348 μg mL?1, respectively. The proposed method has been successfully applied to the determination of piroxicam in commercial dosage forms. The results are compared with the reference El‐Ries et al. spectrophotometric method.  相似文献   

14.
Simultaneous determination of Al(III) and Fe(III) in posthemodialysis fluids was investigated by the Adsorptive stripping voltammetry of solochrome violet metal complexes. The adsorption of the complexes on the mercury electrode (HMDE) was investigated by out of phase altenating current voltammetry in presence of the main matrix interfering species. Sample digestion by UV irradiation was investigated to overcome the matrix interference. The proposed method was valid for real posthemodialysis samples containing or not Desferrioxamine B. Detection limits of 1.4 and 1.8 μg L?1 were calculated for Al(III) and Fe(III), respectively. Recoveries ranging from 88.1 to 106.3% were obtained from spiking experiments.  相似文献   

15.
The mean centering of ratio kinetic profiles method was used for the simultaneous determination of binary mixtures of Ni(II) and Zn(II) in water samples, without prior separation steps. The method is based on the difference in the rate of the reaction of Ni(II) and Zn(II) with xylenol orange at pH 5.3. The method allows rapid and accurate determination of Ni(II) and Zn(II). The analytical characteristics of the methods for the simultaneous determination of binary mixtures of Ni(II) and Zn(II) were calculated. The linear range was 0.025‐2.400 μg mL?1 and 0.025‐2.20 μg mL?1 for Zn(II) and Ni(II), respectively. Interference effects of common anions and cations were studied, and the method was successfully applied to the simultaneous determination of Zn(II) and Ni(II) in water samples.  相似文献   

16.
The H-point standard addition method was applied to kinetic data for simultaneous determination of Fe(II) and Fe(III) or selective determination of Fe(II) in the presence of Fe(III). The method is based on the difference in the rate of complex formation between iron in two different oxidation states and methylthymol blue (MTB) at pH 3.5 in mixed cetyltrimethylammonium bromide (CTAB) and Triton X-100 micellar medium. Fe(II) can be determined in the range 0.25-2.5 microg ml(-1) with satisfactory accuracy and precision in the presence of excess Fe(III) and other metal ions that rapidly form complexes with MTB under working condition. The proposed method was successfully applied to the simultaneous determination of Fe(II) and Fe(III) or selective determination of Fe(II) in the presence of Fe(III) in spiked real environmental and synthetic samples with complex composition.  相似文献   

17.
A novel solid phase extraction technique for determination of total iron in environmental water samples was developed. The method is based on sorption of Fe(III) ions on octadecyl silica membrane disk modified with a new synthetic ligand dimethyl(E)‐2‐(2‐methoxyphenoxy)‐2‐butenedioate (I). Iron(III) is quantitatively retained on the disk in the pH range of 3–7 at a flow rate of 1–7 mL min−1. The Fe(III) eluted with 10 mL of 0.01 M EDTA and than was measured by flame atomic absorption spectrometry (FAAS) at 248.3 nm. The maximum capacity disk modified by 7 mg of ligand was found to be 197 ± 2 μg of iron(III). The breakthrough volume was greater than 2000 mL. The iron(III) was completely recovered (> 99%) from water with a preconcentration factor of more than 200. The limit of detection of the proposed method was 1.00 ng mL−1. The various cationic and anionic interferences had no effect on the recovery of iron(III) from the binary mixtures. The proposed method was successfully applied to determination of total iron from three different water samples.  相似文献   

18.
A second‐derivative spectrophotometric method based on zero‐crossing over technique is developed in simultaneous determination of copper(II) and nickel(II) ions. Methylthymol blue (MTB) as a chromogenic reagent and cetyltrimethylammonium bromide as a surfactant were used, and measurements were carried out in buffered solution at pH 6 and at a temperature of 25 °C. The amplitude of derivative spectra was measured at wavelengths of 631.9 and 587.7 nm for the simultaneous determination of Ni2+ and Cu2+, respectively. Linearity was obtained in the range of 0.5–5.0 μg mL?1 for both ions in the presence of 0.0–5.0 μg mL?1 of the other ion as an interfering ion. IUPAC detection limits for Cu2+ and Ni2+ ions were obtained at 0.48 and 0.43 μg mL?1, respectively. The proposed procedure has been applied successfully for the simultaneous determination of copper and nickel in synthetic binary mixtures and real samples.  相似文献   

19.
A simple, sensitive and accurate spectrophotometric method has been described for the determination of ampicillin(I), amoxicillin trihydrate(II) and cefazolin sodium(III). The procedure is based on the formation of Prussian Blue (PB) complex. The reaction between the acidic hydrolysis products of antibiotics (T = 60 °C) with mixture of Fe3+ and hexacyanoferrate(III) ions was evaluated for the spectrophotometric determination of the mentioned drugs. The maximum absorbance of the colored complex occurs at λ = 700 nm and the molar absorptivity is 3.0 × 104 1 mol?1cm?1. The effect of various parameters such as concentration of K3Fe(CN)6 and Fe3+, nature and amount of acids used, temperature and time of heating were investigated. Under optimum conditions the linear range of calibration graph was 2.0–12.0, 5.0–13.5 and 3.0–12.0 μg mL?1 for ampicillin, amoxicillin and cefazolin, respectively. The relative standard deviation for the determination of 10 μg mL?1 of antibiotics was about 0.5–1.5%. The proposed method was successfully applied to the determination of selected antibiotics from pharmaceutical preparations. The validity of the method was tested by the official methods and by the recovery studies of standard addition to pharmaceuticals.  相似文献   

20.
Cloud point extraction was applied as a preconcentration step for the determination of trace level of Al(III) in water samples with electrothermal atomic absorption spectrometry (ETAAS), flame atomic absorption spectrometry (FAAS) and UV-visible spectrophotometry. The aluminum was extracted as aluminum-Eriochrome Cyanine R (ECR) complex, at pH 6 by micelles of the non-ionic surfactant octylphenoxypolyethoxyethanol (Triton X-114). The investigations showed that the same CPE procedure can be used for different detection techniques. The results obtained from these techniques were evaluated. Under the optimal conditions, limit of detection obtained with ETAAS, FAAS and UV-visible spectrophotometry were 0.03 ng mL?1, 0.06 µg mL?1 and 0.01 µg mL?1, respectively. The accuracy of the procedure was tested by analysing certified reference material. The method was successfully applied to determination of aluminum in water samples and dialysis fluid.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号