首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Headspace liquid-phase microextraction (HS-LPME) has been applied to efficient enrichment of phenols such as 2-nitrophenol, 4-chlorophenol, 2,4-dichlorophenol, and 2-naphthol from water samples based on 1-butyl-3-methylimidazolium hexafluorophosphate ([C4MIM][PF6]) as an extractant. Some parameters that may influence HS-LPME were investigated. The linear range was in the range of 0.5-100 microg/L, and the enrichment factors and repeatability (RSD, n = 6) of the proposed method were in the range of 17.2-160.7 and 5.4-8.9%, respectively. The detection limit for each analyte ranged from 0.3 to 0.5 microg/L. Complex matrices of environmental water samples had a small effect on the enrichment, and this problem could be resolved by the addition of sodium ethylene diamine tetraacetate (EDTA) into the samples. The spiked recoveries were in the range of 89.4-114.2%. All these facts demonstrated that the proposed method, with merits of low cost, simplicity, and easy operation, would be a competitive alternative procedure for the determination of such compounds at trace level.  相似文献   

2.
The degradation of 2-(2,4-dichlorophenoxy)-5-chlorophenol (triclosan) in chlorinated water samples was investigated. Sensitive determination of the parent compound and its transformation products was achieved by gas chromatography with mass spectrometry detection after sample concentration, using a solid-phase extraction sorbent and silylation of the target compounds. Experiments were accomplished using ultrapure water spiked with chlorine and triclosan concentrations in the low mg/l and ng/ml ranges respectively. Chlorination of the phenolic ring and cleavage of the ether bond were identified as the main triclosan degradation pathways. Both processes led to the production of two tetra- and a penta-chlorinated hydroxylated diphenyl ether, as well as 2,4-dichlorophenol. The formation of 2,3,4-trichlorophenol was not detected in any experiment; however, significant amounts of 2,4,6-trichlorophenol were noticed. All of these five compounds were also identified when triclosan was added to tap-water samples with free chlorine concentrations below 1 mg/l. Minor amounts of three di-hydroxylated phenols, containing from one to three atoms of chlorine in their structures, were also identified as unstable triclosan chlorination by-products. The analysis of several raw wastewater samples showed the co-existence of important concentrations of triclosan and its most stable by-products (2,4-dichlorophenol and 2,4,6-trichlorophenol), reinforcing the potential occurrence of the described transformations when products containing triclosan are mixed with chlorinated tap water.  相似文献   

3.
Alkaline water was used for the microwave-assisted extraction of some priority pollutants of phenols in sediments, i.e. phenol (Ph), 2-chlorophenol (2CP), 2,4-dichlorophenol (2,4DCP), 4-chlorophenol (4CP), 4-dinitrophenol (4NP) and pentachlorophenol (PCP). This organic solvent-free extraction procedure was optimized by studying the parameters such as pH, volume of the alkaline water, extraction pressure and time. Under the optimized conditions, the recoveries of phenols were in the range of 80% to 110%. The extracts were then cleaned-up and concentrated by microcolumn solid phase extraction (SPE) and determined by gas chromatography-flame ionization detection system. The relative standard deviation of the overall-method for most phenol determinations was about 5.0% (n = 6). The proposed method, which needs little volume (1 mL) of ethanol for SPE, has been applied to determine these phenols in sediment samples, and the analytical results are in good agreement with those achieved by Soxhlet extraction.  相似文献   

4.
This paper describes a new analytical system, based on the combination of continuous flow liquid membrane extraction (CFLME) enrichment and capillary electrophoresis (CE) separation, for analysis of chlorinated phenols in water samples. Five chlorinated phenols including 3-chlorophenol (3CP), 4-chlorophenol (4CP) 2,4-dichlorophenol (DCP), 2,4,6-trichlorophenol (TCP), and pentachlorophenol (PCP) were separated by CE with Tris/sodium dihydrogen phosphate solution containing methanol 1% (v/v) as the run buffer. CFLME related parameters were investigated and optimal enrichment was obtained by using 0.3 mol L(-1) Tris as acceptor and with a sample pH 5.0, a sample flow rate of 4.0 mL min(-1), and an enrichment sample volume of 150 mL. The detection limit (S/N= 3) was 6.9, 1.0, and 1.7 ng mL(-1) for DCP, PCP, and TCP, respectively. The reproducibility (RSD%, n = 6) was 5.7 for DCP, 2.5 for PCP, and 2.8% for TCP (n = 6). The proposed method was applied to the determination of chlorinated phenols in spiked water samples with relatively satisfactory recoveries.  相似文献   

5.
A fully automated solid-phase extraction (SPE)-high-performance liquid chromatographic method has been developed for the simultaneous analysis of substituted anilines and phenols in aqueous matrices at the low- to sub-microg/l level. Diode array and electrochemical detection operated in tandem mode were used for analyte detection. Two new polymeric sorbent materials (Hysphere-GP and Hysphere-SH) were evaluated for the on-line SPE of substituted anilines and phenols from aqueous matrices and their performance was compared with the PRP-1 and PLRP-S sorbents. Hysphere-GP sorbent packed in 10 x 2 mm cartridges was found to give better results in terms of sensitivity and selectivity of the overall analytical method. The proposed analytical method was validated for the analysis of these compounds in Axios river water that receives industrial, communal and agricultural wastes. The detection limits for all the compounds range between 0.05 and 0.2 microg/l, except for aniline and phenol which have detection limits of 0.5 and 1 microg/l, respectively (aniline detected by electrochemical detection). The recoveries for all the compounds are higher than 75% except for aniline (6%), phenol (50%) and 3-chlorophenol (67%). Finally, in order to evaluate the efficiency of the Hysphere-GP (10 x 2 mm) cartridges for sample stabilization and storage, the stability of the compounds of interest at the sorbed state onto these cartridges has been evaluated under three different temperature regimes (deep freeze, refrigeration, 20 degrees C).  相似文献   

6.
Membrane-assisted solvent extraction (MASE) was applied for the determination of seven phenols (phenol, 2-chlorophenol, 2,4-dimethylphenol, 2,4-dichlorophenol, 4-chloro-3-methylphenol, 2,4,6-trichlorophenol and pentachlorophenol) with log Kow (octanol-water-partition-coefficient) between 1.46 (phenol) and 5.12 (pentachlorophenol) in water. The extraction solvents cyclohexane, ethyl acetate and chloroform were tested and ethyl acetate proved to be the best choice. The optimisation of extraction conditions showed the necessity of adding 5 g of sodium chloride to each aqueous sample to give a saturated solution (333 g/L). The pH-value of the sample was adjusted to 2 in order to convert all compounds into their neutral form. An extraction time of 60 min was found to be optimal. Under these conditions the recovery of phenol, the most polar compound, was 11%. The recoveries of the other analytes ranged between 42% (2-chlorophenol) and 98% (2,4-dichlorophenol). Calibration was performed using large volume injection (100 microL injection volume). At optimised conditions the limits of detection were between 0.01 and 0.6 microg/L and the relative standard deviation (n = 3) was on average about 10%. After the method optimisation with reagent water membrane-assisted solvent extraction was applied to two contaminated ground water samples from the region of Bitterfeld in Saxony-Anhalt, Germany. The results demonstrate the good applicability of membrane-assisted solvent extraction for polar analytes like phenols, without the necessity of derivatisation or a difficult and time-consuming sample preparation.  相似文献   

7.
A metallomesogenic side-chain polymer with copper carboxylato discotic units in stacks prepared by covalent bonding of 14-pentadecenoic acid, stearic acid and poly(methylhydrosiloxane) is described. The physico-chemical and thermal properties of both monomeric and polymeric metallomesogens were determined by elemental analysis, IR, polarizing optical microscopy, thermal gravimetric analysis and differential scanning calorimetry. The polymeric states showed a discotic lamellar phase at 50-95 degrees C and an ordered discotic hexagonal phase at 95-200 degrees C. By dynamic coating, the metallomesogenic polymer was crosslinked to the capillary wall via benzoyl peroxide. The wall-coated capillary columns (15 m x 0.25 mm I.D.) were used for the separation of phenols. Factors affecting the retention and the sample selectivity were examined. Van 't Hoff plots as a function of temperature indicated that phase transitions were occurring. Thermodynamic properties of the analytes in this system were also studied. For the determination of a mixture of 3-aminophenol, 2-chlorophenol, 2-nitrophenol, 4-nitrophenol, o-methylphenol, m-methylphenol, p-methylphenol, 2,4-dichlorophenol, 2,4-dimethylphenol, 2,4-dinitrophenol, 2,4,6-trichlorophenol, 2,4,6-trimethylphenol, 4-bromophenol, 3-methyl-4-chlorophenol, pentachlorophenol, and unsubstituted phenol, the calibration graphs for most phenols were linear over the range of 10-1000 microg ml(-1) and the mass detection limits were in the ng range based on three times standard deviation of seven measurements of the lowest peak that could be detected.  相似文献   

8.
S Nakamura  M Takino  S Daishima 《The Analyst》2001,126(6):835-839
A method for the trace level determination of 11 phenols as pentafluorobenzyl (PFB) derivatives by gas chromatography-mass spectrometry (GC-MS) with negative-ion chemical ionization (NICI) is described. First, the conditions for the PFB derivatisation of phenols were optimized and were found to be reaction temperature 80 degrees C and reaction time 5 h. Second, the detection limits using selected ion monitoring (SIM) were compared between trimethylsilylated (TMS) derivatives in the electron ionization (EI) mode and PFB derivatives in the NICI mode. The responses for the PFB derivatives in the NICI mode were 3.3-61 times higher than those of the TMS derivatives in the EI mode. The instrumental detection limits using NICI-SIM ranged from 2.6 to 290 fg. This method was applied to the analysis of phenols in river water using solid-phase extraction. The recoveries of the phenols from a river water sample spiked with standards at 100 ng l-1 with 2-chlorophenol, 4-chloro-3-methylphenol and pentachlorophenol and at 1000 ng l-1 with phenol, 2,4-dimethylphenol, 2,4-dichlorophenol, 2-nitrophenol, 2,4,6-trichlorophenol and 4-nitrophenol were 81.2-106.3% (RSD 5.1-8.0%), except for 2-methyl-4,6-dinitrophenol and 2,4-dinitrophenol, for which the recoveries were 5.8 and 4.2%, respectively, because water contained in the acetone eluate interfered with the derivatisation of these compounds with two electrophilic nitro groups.  相似文献   

9.
Liquid phase microextraction with back extraction (LPME/BE) combined with high-performance liquid chromatography (HPLC) was studied for the determination of a variety of phenols in water samples. The target compounds were extracted from 2-ml aqueous sample adjusted to pH 1 (donor solution) through a microliter-size organic solvent phase (400-microl n-hexane), confined inside a small PTFE ring, and finally into a 1-microl basic aqueous acceptor microdrop suspended inthe aforementioned solvent phase from the tip of a microsyringe needle. After extracting for a prescribed time, the microdrop was taken back into the syringe and directly injected into an HPLC for detection. Factors relevant to the extraction procedure were studied. At the optimized extraction conditions, a large enrichment factor (more than 100-fold) can be achieved for most of the phenols within 35 min. The detection limit range was 0.5-2.5 microg/l for different analytes in aqueous samples. The results demonstrate the suitability of the LPME/BE approach to the analysis of polar compounds in aqueous samples.  相似文献   

10.
To develop a new solvent-impregnated resin system for the removal of phenols from water the complex formation of triisobutylphosphine sulfide (TIBPS), tributylphosphate (TBP), and tri-n-octylphosphine oxide (TOPO) with a series of phenols (phenol, thiophenol, 3-chlorophenol, 3,5-dichlorophenol, 4-cyanophenol, and pentachlorophenol) was studied. The investigation of complex formation between the extractants and the phenols in the solvent toluene was carried out using liquid-liquid extraction, isothermal titration calorimetry (ITC), and quantum chemical modeling (B3LYP/6-311+G(d,p)//B3LYP/6-311G(d,p) and MP2/6-311++G(2d,2p)//B3LYP/6-311G(d,p)). The equilibrium constant (binding affinity, Kchem), enthalpy of complex formation (DeltaH), and stoichiometry (N) were directly measured with ITC, and the entropy of complexation (DeltaS) was derived from these results. A first screening of K chem toward phenol revealed a very high binding affinity for TOPO, and very low binding affinities for the other extractants. Modeling results showed that although 1:1 complexes were formed, the TIBPS and TBP do not form strong hydrogen bonds. Therefore, in the remainder of the research only TOPO was considered. Kchem of TOPO for the phenols in toluene increased from 1,000 to 10,000 M(-1) in the order phenol < pentachlorophenol < 3-chlorophenol < 4-cyanophenol approximately 3,5-dichlorophenol (in line with their pKa values, except for pentachlorophenol) in the absence of water, while the stoichiometric ratio remained 1:1. In water-saturated toluene, the binding affinities are lower due to co-complexation of water with the active site of the extractant. The increase in binding affinity for TOPO in the phenol series was confirmed by a detailed ab initio study, in which Delta H was calculated to range from -10.7 kcal/mol for phenol to -13.4 kcal/mol for 4-cyanophenol. Pentachlorophenol was found to behave quite differently, showing a DeltaH value of -10.5 kcal/mol. In addition, these calculations confirm the formation of 1:1 H-bonded complexes.  相似文献   

11.
A new method for the determination of polycyclic aromatic hydrocarbons (PAHs) in waste water using solvent-free solid-phase microextraction (SPME) is described. The PAHs are extracted with a 100 microm polydimethylsiloxane (PDMS) fiber, desorbed in 40 microl acetonitrile and measured with LC and fluorescence detection. The detection limits of this very simple method under the given conditions (extraction from 5 ml sample, extraction time 1 h) are in the range of 1-6 ng l(-1). The standard deviations (n = 6) at a concentration level of 0.8 microg l(-1) are between 1.8 and 14.4%. The procedure was used for the determination of PAHs in contaminated water samples.  相似文献   

12.
A new reagent, anthraquinone-2-sulfonyl chloride, is used for the derivatizaton of phenols. Several compounds with different polarities are selected to evaluate the new reagent and derivatives of these phenols that are prepared via a facile pathway. The optimal conditions for analytical derivatization and mechanism of the derivatization reaction are discussed. The derivatization procedure involves an ion-pair extraction of the deprotonated phenols with a tetrabutylammonium counter ion in the organic phase. At the interface of two phases, the derivatization reaction occurs quantitatively at room temperature within 3 min. The derivatives are stable and readily amenable to analysis by normal-phase (NP) and reversed-phase (RP) high-performance liquid chromatography (HPLC). Excellent linearity response was demonstrated over the concentration range of 0.2-200 micromol/L at 320 nm for NP-HPLC and at 256 nm for RP-HPLC. Combined with preconcentration using a Waters Sep-Pak Plus C(18) cartridge, detection limits of phenols for water-sample analysis are as low as 1 x 10(-9) mol/L (approximately 0.1 microg/mL).  相似文献   

13.
A simple and inexpensive method for sorptive extraction of phenols from water samples is presented. A polydimethyl siloxane (PDMS) stir bar (Twister) is used as an extraction medium for derivatized phenols, which is thermally desorbed and analyzed by gas chromatography-mass spectrometry (GC-MS). Its performance was illustrated and evaluated for the enrichment of microg l(-1) to ng l(-1) of phenol and selected chlorophenols in water samples. The method showed good linearity, recoveries and blank levels, as well as advantages such as sensitivity, simplicity, low cost and high feasibility, being successfully applied for the analysis of phenolic compounds in natural water samples.  相似文献   

14.
A pyrrole-based polymer was synthesized and applied as a new sorbent for solid-phase extraction (SPE) of some environmental pollutants from water samples. Polypyrrole (PPy) was synthesized by chemical oxidation of the monomer in nonaqueous solution. SPE of selected phenols, pesticides, and polyaromatic hydrocarbons (PAHs) from aqueous samples were performed using 200 mg PPy. The determination was subsequently carried out by gas chromatography-flame ionization detection (GC-FID) and gas chromatography-mass spectrometry (GC-MS). The polymer showed much higher recoveries for aromatic compounds than aliphatics. Preconcentration of sample volumes up 11 led to acceptable recoveries for aromatic and other tested polar compounds. The R.S.D. for a river water sample spiked with phenols, pesticides and PAHs at sub-ppb level was lower than 10% (n = 3) and limits of detection for these compounds were between 15 and 120 ng l(-1).  相似文献   

15.
Solid-phase microextraction (SPME) coupled to gas chromatography-mass spectrometry (GC-MS) has been applied to determine six phthalate esters and one adipate ester in water. The SPME parameters were optimized for several commercially available fibers. A 65-microm polydimethylsiloxane-divinylbenzene (PDMS-DVB) was the fiber selected and was applied to analysis of water from the Ebro river and the industrial port of Tarragona. The studied compounds were found at concentrations ranging from 0.4 microg l(-1) for di-n-butyl phthalate ester (DnBP) to 3.2 microg l(-1) for bis(2-ethylhexyl) phthalate ester (DEHP). The linear range for real samples was from 0.1 to 10 microg l(-1) for most phthalates, and the limits of detection of the method were between 3 and 30 ng l(-1). Repeatability and reproducibility between days (n = 5) for 1 microg l(-1) samples were below 13 and 18%, respectively.  相似文献   

16.
The applicability of a previously optimized method for the analysis of the US Environmental Protection Agency (EPA) regulations phenols, based on on-line solid-phase extraction coupled to liquid chromatography with mass spectrometric (MS) detection in different matrix loaded water samples is demonstrated. The comprehensive optimization of the mobile phase conditions and their influence on the ionization process in atmospheric pressure ionization is described in detail. In particular, MS detection of the weakly acidic phenols such as phenol, monochlorinated phenols and methylated phenols requires the absence of acidic mobile phase modifiers and buffers. Thus lower retention times and slight peak broadening of the more acidic dinitrophenols are obtained if the entire range of EPA phenols is analyzed within a single chromatographic run. The figures of merit for the method were determined and the applicability to real water samples was investigated. Limits of detection for phenols ranging from 40 to 280 ng l(-1) and relative standard deviations below 8% in SCAN mode are obtained for all phenols if only 10-ml river water samples with low dissolved organic carbon (DOC 5 mg C l(-1) concentrations are preconcentrated. The method was used to detect 2-nitrophenol and 4-nitrophenol in river water samples in the lower ng l(-1) range. The analysis of highly matrix-loaded samples (DOC 210 mg C l(-1)) requires a reduced enrichment volume resulting in decreased sensitivity. Still the method is capable of reaching excellent detection limits which demonstrates its excellent suitability for screening analysis.  相似文献   

17.
A drop-based liquid phase microextraction and gas chromatographic-electron capture detection (GC-ECD) method was described for the determination of chlorobenzenes including chlorobenzene, 1,2-dichlorobenzene, 1,3-dichlorobenzene, 1,4-dichlorobenzene and 1,2,3-trichlorobenzene in 5 ml of water. The method used 2 microl of n-hexane as extraction solvent, 5 min extraction time, a stirring rate of 600 rpm and sample ionic strength of 3 M maintained with sodium chloride at 25 degrees C (ambient temperature). The limits of detection (LODs) ranged from 0.004 microg l(-1) (for 1,3-dichlorobenzene) to 0.008 microg l(-1) (for monochlorobenzene). The dynamic linear range for all investigated chlorobenzenes was 1-50 microg l(-1). Recoveries of chlorobenzenes from fortified distilled water are over 90% for three different fortification levels (5, 15 and 45 microg l(-1)) and relative standard deviations of the recoveries are below 6%. Analysis of fortified (5 microg l(-1)) real water samples revealed that matrices had no adverse effect on extraction efficiency of proposed method. The recovery of fortified real water samples was from 90 to 94% with relative standard deviations below 6%.  相似文献   

18.
A simple and rapid method for the determination of eleven phenols in water samples is presented. The target analytes are isolated by stir membrane liquid-liquid microextraction working under the three-phase mode. An alkaline aqueous solution is used as extractant phase while octanol is selected as supported liquid membrane solvent. The target analytes are separated and determined by liquid chromatography (LC) with ultraviolet detection (UV). All the variables involved in the extraction process have been studied in depth. Low detection limits (in the range from 82.1 ng/L for phenol to 452 ng/L for 2,4,5-trichlorophenol) were obtained. The repeatability, expressed as relative standard deviation (RSD), varied between 1.3% (for 4-nitrophenol) and 8.0% (for 4-chlorophenol). The enrichment factors were in the range from 168 (for 2,4,5-trichlorophenol) to 395 (for 3-chlorophenol). The proposed procedure was applied for the direct determination of the eleven phenols in some real water samples including river, well and tap waters. The accuracy was evaluated by means of a recovery study, the results being in the range of 87-120%.  相似文献   

19.
Bromate is a well known by-product produced by the ozonisation of drinking water; the allowed concentration for human consumption has to be regulated to the low microg l(-1) range. A direct injection, ion chromatographic method was developed using a tetraborate eluent with serially connected conductivity and spectrophotometric detection. Bromate was detected after post-column reaction with fuchsin at 520 nm. Sample capacity was investigated by injecting large volumes (up to 6 ml) using a high total hardness and chloride tap water. Linear correlation of bromate response with volumes from 1 ml to 6 ml was demonstrated, the main limitation being the overlapping of the chloride peak with bromate. Up to 1.5 ml sample can be injected without any pre-treatment. With more than 1.5 ml injection volume, a sample pre-treatment with a cartridge in Ag and H form, followed by a 10 min degassing in an ultrasonic bath, was needed. This method was validated by analysing secondary reference materials and real samples from a drinking water treatment plant. The method was linear from the limit of quantification to 20 microg l(-1). Reproducibilities in tap water were 18% (5 microg l(-1), n=12) and 21% (1 microg l(-1), n=4) respectively for 1.5 and 6 ml injection volumes with conductivity detection, and 17% at 0.5 microg l(-1) (n=9) with spectrophotometric detection. Calculated detection limits were 0.5 microg l(-1) (6 ml) ahd 2 microg l(-1) (1.5 ml) for conductivity detection and 0.3 microg l(-1) (1.5 ml) for spectrophotometric detection.  相似文献   

20.
A new method of analysis of 11 phenols, including five bibenzyls, three phenanthrenes, and three fluorenones, using high-performance liquid chromatography (HPLC)-diode array detection (DAD) was described. The separation of 11 phenols was effected by RP-HPLC (Beckman Coulter ODS column, 5 microm, 250 mm x 4.6 mm) using linear gradient elution systems of acetonitrile-1/1000 trifluoroacetic acid (TFA). Satisfactory separation of these compounds was obtained in less than 45 min. The method was validated for linearity, repeatability, limits of detection (LOD) and limits of quantification (LOQ). Good results were obtained with respect to repeatability (relative standard deviation (RSD)<3.5%) and recovery (85.77-104.92%). The developed method was applied to the simultaneous determination of 11 phenols from totally 31 Dendrobium species (mainly of medicinal plants) as well as other four samples from the similar genera as Pholidota, Flickingeria and Bulbophyllum. The range of the total amounts of bibenzyl, phenanthrene and fluorenone were found to from trace: 4.00, not detected (nd): 0.42 and nd: 0.24 microg mg(-1), respectively.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号