首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Capillary electrophoresis methods were developed for the enantiomeric separation of 27 citalopram analogues. Sulfated β‐cyclodextrin was the most broadly selective and useful chiral selector. The separations of most of the citalopram analogue compounds reported in this work have not been reported previously. Excellent enantiomeric separations were obtained for 26 out of 27 compounds, and most of the separations were achieved within 10 min. The effects of chemical parameters such as chiral selector types, buffer types, chiral selector and buffer concentrations, buffer pH and organic modifiers on the separation were investigated. The influence of analyte structure on separation also was examined and discussed.  相似文献   

2.
The enantiomeric separations of highly hydrophobic furan derivatives and polycycles were performed and optimized using CD-modified micellar CE. The most effective chiral selector for the enantiomeric separation of these analytes was hydroxypropyl-gamma-CD. The effects of CD and SDS concentration and organic modifier were examined in order to optimize the separation conditions. The ratio of CD to surfactant concentration affected the enantiomeric separation significantly, with increases in the derivatized CD concentration generally enhancing resolution. Addition of an organic solvent modifier to the run buffer served to increase the analytes' solubility and enhance the separation efficiency. A highly acidic pH was necessary to effectively suppress the EOF when operating in the reverse polarity mode.  相似文献   

3.
Summary Six different cyclodextrins with varying cavity size and rim substitution were used as chiral agents for the enantiomeric separation of eight chromane compounds or analogues using capillary electrophoresis. It is shown that the cyclodextrin type and concentration have a large influence on the enantiomeric separation obtained for these compounds. A chiral resolution of 1.4 or better could be obtained for all the substances with either substituted heptakis(2,3,6-tri-O-methyl)-β-cyclodextrin or unsubstituted γ-cyclodextrin as the chiral selector. The influence of the γ-cyclodextrin concentration, ionic strength and pH on the chiral separations was also investigated with a multivariate screening design. The detection limit and resolution of the present method allow determinations of the investigated compounds down to a chiral impurity of less than 0.1 % (area/area).  相似文献   

4.
The enantiomeric separation of a novel series of twenty-eight racemic mixtures of citalopram analogues was performed by high performance liquid chromatography (HPLC). Due to the effectiveness of citalopram as an antidepressant drug, the development of new compounds based on its chemical structure is interesting, and their enantiomeric separation is needed to allow further pharmacokinetic studies. Several bonded cyclodextrin (both native and derivatized) and macrocyclic glycopeptide based chiral stationary phases (CSPs) were evaluated for their ability to separate this set of compounds via HPLC. Polar ionic, polar organic, and reversed phase modes were tested. Twenty-five of the racemic mixtures were separated with resolutions and enantiomeric selectivities up to 2.9 and 1.33, respectively. A total of eighteen baseline separations were achieved, while seven compounds were partially separated. Vancomycin based columns operated in the polar ionic mode resulted in the greatest number of separations. Lastly, the chromatographic behaviors of similar compounds were compared based on their chemical structure and also on the chiral selectors used.  相似文献   

5.
Capillary electrophoresis methods for the enantioresolution of two beta-blockers possessing two chiral centers--labetalol and nadolol--were developed using electrokinetic chromatography. These methods were based on the addition of sulfated beta-cyclodextrins (S-betaCD) as chiral selectors to the background electrolyte (BGE). Different operating parameters (pH and ionic strength of the BGE, concentration of S-beta-CD) were investigated using a normal or reversed polarity mode. A complete resolution of the four isomers of labetalol was obtained either at the cathode or at the anode according to the pH of the BGE. The resolution of nadolol was observed whatever polarity of the applied voltage but a baseline separation of the four enantiomers within a time of analysis appropriate to routine assay was only obtained at the anode. This optimal separation was performed using high concentrations of chiral additive in an acidic pH buffer of low molarity. Besides the complete enantiomeric separation of the beta-blockers studied, the interest of the proposed methods is to permit a reversal of the migration order of the different enantiomers. This could be of high interest in quality control for the study of enantiomeric purity, which is now required for the development of drugs and chemicals.  相似文献   

6.
Chiral dihydrofurocoumarin compounds are currently the focus of industrial and pharmacological research. These derivatives have been shown to possess many physiological properties that could be medically beneficial. This work proposes four different chiral separation methods using capillary electrophoresis and micellar capillary electrophoresis (MCE). Several different cyclodextrin chiral selectors were examined to evaluate their effectiveness in the enantioseparation of dihydrofurocoumarins. In addition, the effects of the chiral selector concentration, the presence of an organic modifier, run buffer pH, and in two cases, the ratio between the chiral selector and an additional charged pseudophase were investigated. Overall, the best separations for this class of chiral compounds were achieved using sulfated beta-cyclodextrins at low pH in the reversed polarity mode.  相似文献   

7.
La S  Kim J  Kim JH  Goto J  Kim KR 《Electrophoresis》2003,24(15):2642-2649
Simultaneous enantioseparations of nine profens for their accurate chiral discrimination were achieved by capillary electrophoresis (CE) in the normal polarity (NP) mode with a single cyclodextrin (CD) system and in the reversed polarity (RP) mode with a dual CD system. The single CD system in the NP mode employed heptakis(2,3,6-tri-O-methyl)-beta-cyclodextrin (TMbetaCD) added at 75 mM-100 mM 2-(N-morpholino)ethanesulfonic acid buffer (pH 6.0) as the optimum run buffer. The dual CD system operated in the RP mode used 30 mM TMbetaCD and 1.0% anionic carboxymethyl-beta-cyclodextrin dissolved in pH 3.0, 100 mM phosphoric acid-triethanolamine buffer containing 0.01% hexadimethrine bromide added to reverse the electroosmotic flow. Fairly good enantiomeric resolutions and the opposite enantiomer migration orders were achieved in the two modes. Relative migration times to internal standard under respective optimum conditions were characteristic of each enantiomer with good precision (< 2% relative standard deviation, RSD), thereby enabling to crosscheck the chemical identification of profens and also their accurate chiralities. The method linearity in the two modes was found to be adequate (r > or = 0.9991) for the chiral assay of the profens investigated. Simultaneous enantiomeric purity test of ibuprofen, ketoprofen and flurbiprofen in a mixture was feasible in a single analysis by the present method.  相似文献   

8.
Chiral binaphthols belong to the group of most effective ligands for asymmetrical catalysis. In this context, various binaphthols presenting original substituents have been synthesized. Their study through capillary electrophoresis is the object of this work. The literature dedicated to the separation of atropisomers by capillary electrophoresis, corresponding only to binaphthol, reveals that its enantioseparation is always delicate because of the influence of many factors and the resolutions obtained are weak. Therefore, for a structured optimization, we first successfully evaluated the acidity constants of different binaphthols by means of capillary electrophoresis. With these known physicochemical characteristics, we could successfully carry out enantiomeric separations of the different binaphthols at pH 11.5, practically in completely ionized form, in phosphate medium, and in the presence of cyclodextrin (CD), with analysis times lower than 8min. The nature of CDs (alpha-CD, beta-CD, gamma-CD, hydroxypropyl-alpha-cyclodextrin (HP-alpha-CD), HP-beta-CD, HP-gamma-CD and trimethyl-beta-CD (TM-beta-CD)) and other factors in relation to enantiomeric resolution (applied voltage, nature and concentration of the electrolyte, and concentration of cyclodextrin) were optimized. These studies allowed us to determine the optimal conditions of separation (concentration and nature of CD) for each of the studied binaphthols. It is necessary to mention that, for the 1,1'-binaphthyl-2,2'-diol (Binol) at pH 11.5, the S atropisomer always migrated first, regardless of the nature and concentration of the cyclodextrin used. Moreover, an inversion in elution order of the two atropisomers as a function of pH was observed with gamma-CD (pH range: 10-11.5). The R atropisomer migrated first at pH 10. At pH 10.8 the migration order of the two atropisomers of Binol was reversed as a function of gamma-CD concentration. Finally, the addition of chiral ionic liquids (R(-)-1-hydroxy-N,N,N-trimethylbutan-2-aminium bis(trifluoromethylsulfonyl)imide and S(+)-tetrabutylammonium camphorsulfonate) was conducted. In the case of S(+)-tetrabutylammonium camphorsulfonate, a weak antagonistic effect was observed with modeling the evolution of enantiomeric resolution by means of the experimental design, while in the case of R(-)-1-hydroxy-N,N,N-trimethylbutan-2-aminium bis(trifluoromethylsulfonyl)imide the effect was neutral.  相似文献   

9.
阮宗琴  李菊白  陆豪杰  欧庆瑜 《色谱》2000,18(2):148-151
 将负电性磺丁基 -β -环糊精手性添加剂应用于毛细管电泳氨基酸对映体的拆分研究中 ,对 8种氨基酸对映体与 9-芴甲基氧基甲酰氯 (FMOC-Cl)生成的衍生物进行了分离 ,其中 5种得到了基线分离。考察了背景电解质 p H值及磺丁基 -β -环糊精的浓度对 N-FMOC氨基酸对映体拆分的影响。  相似文献   

10.
A cationic cyclodextrin was used as dynamic coating for the capillary electrophoresis of a model mixture of proteins (i.e., ubiquitin, α‐lactoglobulin, cytochrome‐c, and myoglobin) as positively charged species in a fused silica capillary. An interesting feature of the coating is that by simple adjustment of the concentration of cyclodextrin added into the background electrolyte, a neutral or positively charged surface, which was beneficial in preventing protein adsorption at the inner capillary wall surface, was obtained. This is the first demonstration of a dynamic coating that yielded a neutral surface for protein separations in capillary electrophoresis. Based on electro‐osmotic flow measurements, addition of 0.05 to 0.10 mg/mL quaternary β‐cyclodextrin in a low pH electrolyte resulted in a neutral or positive surface (undetectable to very slow anodic electro‐osmotic flow). The coating approach afforded the electrophoretic separation of the mixture of proteins at positive polarity with good repeatability and separation performance.  相似文献   

11.
A total of 26 different cyclodextrin (CD) derivatives with different functional groups and degrees of substitution were tested against 35 basic pharmaceutical compounds in an effort to investigate their effectiveness as chiral selectors for enantiomeric separation in capillary electrophoresis (CE). Testing was performed under the same conditions using a low pH buffer (25 mM phosphate buffer at pH approximately 2.5). Five CD derivatives, namely, highly sulfated-beta-CD, highly sulfated-beta-CD, hydroxypropyl-beta-CD (degree of substitution approximately 1), heptakis-(2,6-O-dimethyl)-beta-CD, and heptakis(2,3,6-O-trimethyl)-beta-CD were identified to be most effective for enantiomeric separations and have a wide range of enantiomeric selectivity towards the model compounds. Over 90% of the model compounds were enantiomerically resolved with the five identified CD derivatives, at a minimum resolution of 0.5. An additional 20 compounds were also tested to demonstrate the validity of the identified CD derivatives. The five CD derivatives were recommended as the starting chiral selectors in developing enantiomeric separation methods by CE.  相似文献   

12.
GENTRANS, a comprehensive one-dimensional dynamic simulator for electrophoretic separations and transport, was extended for handling electrokinetic chiral separations with a neutral ligand. The code can be employed to study the 1:1 interaction of monovalent weak and strong acids and bases with a single monovalent weak or strong acid or base additive, including a neutral cyclodextrin, under real experimental conditions. It is a tool to investigate the dynamics of chiral separations and to provide insight into the buffer systems used in chiral capillary zone electrophoresis (CZE) and chiral isotachophoresis. Analyte stacking across conductivity and buffer additive gradients, changes of additive concentration, buffer component concentration, pH, and conductivity across migrating sample zones and peaks, and the formation and migration of system peaks can thereby be investigated in a hitherto inaccessible way. For model systems with charged weak bases and neutral modified β-cyclodextrins at acidic pH, for which complexation constants, ionic mobilities, and mobilities of selector-analyte complexes have been determined by CZE, simulated and experimentally determined electropherograms and isotachopherograms are shown to be in good agreement. Simulation data reveal that CZE separations of cationic enantiomers performed in phosphate buffers at low pH occur behind a fast cationic migrating system peak that has a small impact on the buffer composition under which enantiomeric separation takes place.  相似文献   

13.
Four chiral basic analytes, namely methadone, fluoxetine, venlafaxine, and tramadol, were selected as model compounds for investigating their stereoselective separation with highly sulfated gamma-cyclodextrin (HS gamma-CD) by capillary electrophoresis (CE)-UV and CE-mass spectrometry (MS). At high concentration of chiral selector, the preferentially bonded enantiomer migrated faster in the anodic mode to the detector and high resolutions were obtained for all analytes. In the cathodic mode, at lower highly sulphated cyclodextrin (HS-CD) concentration, basic compounds could be detected, with the weakly bonded enantiomer migrating first (enantiomeric migration order inversion). It was also then possible, at intermediate HS-CD concentration, that only one enantiomer migrated to the detector as cation while the other enantiomer complexed with the CD was negatively charged and presented an opposite mobility. The latter never reached the detector achieving a perfect enantiomeric selectivity. Infinite chiral resolutions were thus achieved by CE-UV as well as by CE-electrospray ionisation (ESI)-MS where concentrations of HS-CD were adapted according to the negative contribution of the nebulization gas pressure of the interface.  相似文献   

14.
The enantiomeric separations of 3,4-dihydroxyphenylalanine (dopa) and 2-hydrazino-2-methyl-3-(3,4-dihydroxyphenyl)propanoic acid (carbidopa) by capillary electrophoresis were studied using several native, neutral and anionic cyclodextrins as chiral additives and uncoated fused-silica capillaries. The effect of the type and concentration of the cyclodextrin added to 20 mM phosphate buffer (pH 2.5) on enantioseparation and migration times was studied. A high resolution value of 15.63 was obtained for dopa enantiomers with a buffer containing 20 mM single isomer, heptakis(2,3-diacetyl-6-sulfato)-beta-cyclodextrin. The enantiomers of carbidopa were separated using 20 mM carboxymethyl-beta-cyclodextrin as a chiral resolving agent. Both methods allowed the determination of 0.1% of the D-enantiomer (second migrating) in the presence of the L-enantiomer (first migrating) of dopa and carbidopa with a good precision. These methods also gave good results in terms of precision for both peak area, migration time, linearity and accuracy.  相似文献   

15.
Herein we present the enantioseparation of 10 cardiovascular agents and six bronchiectasis drugs including propranolol, carteolol, metoprolol, atenolol, pindolol, esmolol, bisoprolol, bevantolol, arotinolol, sotalol, clenbuterol, procaterol, bambuterol, tranterol, salbutamol and terbutaline sulfate using carboxymethyl‐β ‐cyclodextrin (CM‐β ‐CD) as chiral selector. To our knowledge, there is no literature about using CM‐β ‐CD for separating carteolol, esmolol, bisoprolol, bevantolol, arotinolol, procaterol, bambuterol and tranterol. During the course of work, changes in pH, CM‐β ‐CD concentration, buffer type and concentration were studied in relation to chiral resolution. Excellent enantiomeric separations were obtained for all 16 compounds, especially for procaterol. An impressive resolution value, up to 17.10, was obtained. In particular, most of them achieved rapid separations within 20 min. Given the fact that enantioseparation results rely on analytes' structural characters, the possible separation mechanisms were discussed. In addition, in order to obtain faster separation for propranolol enantiomers in practical application, the effective length of capillary was innovatively shortened from 45 to 30 cm. After the validation, the method was successfully applied to the enantiomeric purity determination of propranolol in the formulation of drug substances.  相似文献   

16.
Derivatized cyclofructans have been recently introduced as a new class of chiral selectors with great application potential. In this study, a R-naphthylethyl-functionalized cyclofructan 6 based chiral stationary phase (RN CF6 CSP) was used for separation of substituted binaphthyl catalysts in the normal phase HPLC mode. Dominant interaction types that play a role in the separation mechanism were revealed by a linear free energy relationship (LFER) method. In order to evaluate the contribution of the substituent on the cyclofructan structure to retention, the R-naphthylethyl-functionalized β-cyclodextrin (RN CD) CSP was chosen for comparison. Retention factors of 46 widely different solutes, with known solvation parameters, were determined on each of the columns under the same mobile phase compositions used for the enantiomeric separations. The LFER results showed that hydrogen bond acidity and polarity/polarizibility have the greatest impact on retention and enantioresolution on the RN CF6 CSP. The equal influence of the naphthylethyl substituent on the both CSPs was also confirmed while the effects of the basic cyclofructan versus cyclodextrin structures were different. The addition of trifluoroacetic acid to the hexane/propane-2-ol mobile phase was negligible on the RN CF6 CSP for the majority of atropoisomers except for one with ionizable functional groups. The RN CF6 column was shown to be more suitable for enantioseparation of the binaphthyl catalysts than the RN CD column. Higher retention offered by the latter CSP had no positive effect on the enantioresolution.  相似文献   

17.
Modified cyclodextrin derivatives were evaluated as the buffer additives in capillary electrophoresis of several racemic pharmaceutical bases. Uncoated and polyacrylamide-modified silica capillaries were compared for their effectiveness in the enantiomeric resolution and migration reproducibility of model solutes. Using cationic detergents in the mixed-micellar mode, optimized separations of the racemic drug bupivacaine are demonstrated in a spiked serum sample at the therapeutic level. Precision, linearity and sensitivity of the method appear adequate for reliable quantitation required in pharmacokinetic and clinical studies.  相似文献   

18.
A novel strategy for determining the enantiomeric composition of phenylalanine samples that combines ordinary fluorescence spectroscopy, guest-host cyclodextrin chemistry, and multivariate regression modeling is investigated. Partial-least-squares regression (PLS-1) models were developed from fluorescence spectral data obtained with a series of samples containing cyclodextrin guest-host complexes of phenylalanine with different known enantiomeric compositions. The regression models were subsequently validated by determining the enantiomeric composition of a set of independently prepared phenylalanine samples. The ability of the models to correctly predict the enantiomeric compositions of future samples was evaluated in terms of the root-mean-square percent relative error (RMS%RE). The RMS%RE in the mol fraction of D-phenylalanine ranged from 1.3% to 3.0% when beta-cyclodextrin was used as the host molecule for different guest-host concentrations. The RMS%RE in the mol fraction of D-phenylalanine obtained in a similar validation study conducted with gamma-cyclodextrin ranged between 1.8% and 4.0% for different guest-host concentrations. Compared with previous studies done in absorption, fluorescence data were found to be more sensitive and the spectral differences observed as a function of enantiomeric composition were more uniformly spaced, making regression modeling more reliable. As a result, good regression models could be made at lower concentrations than were possible previously when absorption measurements were used.  相似文献   

19.
The enantiomeric separation of three selenoamino acids, D,L-selenomethionine, D,L-selenoethionine and D,L-selenocystine is described. Both sulfated beta-cyclodextrin and vancomycin have been successfully used to separate all enantiomers of the compounds with UV detection. Reproducible separations, in terms of peak area and migration time were obtained using sulfated beta-cyclodextrin with reversed polarity and UV detection. With vancomycin as a chiral selector, reversed polarity was found to be more reproducible than positive polarity in terms of peak migration times.  相似文献   

20.
HPLC enantiomeric separations of a wide variety of racemic analytes was evaluated using chiral stationary phases (CSPs) based on the macrocyclic glycopeptides teicoplanin (T), teicoplanin aglycone (TAG), and methylated teicoplanin aglycone (Me-TAG) in two different mobile phase modes, i.e., the RP mode and the polar organic (PO) mode. Comparison of the enantiomeric separations using Chirobiotic T, Chirobiotic TAG, and the methylated form of TAG were conducted in order to gain a better understanding of the roles of the polar functional groups on the CSP. Substantial effects due to the cleavage of saccharides and/or methylation on chiral separations were observed in both separation modes. Improved separation efficiencies for many acidic analytes were obtained by methylating the H-bonding groups of TAG. These groups were believed to be a contributing factor to band broadening on TAG due to their negative effect on mass transfer between the stationary phase and mobile phase. Ionic/dipolar interactions between the carboxylate group of the analytes and the amine groups on T, TAG, or Me-TAG are important for chiral discrimination. Therefore, analytes possessing a carboxyl group are good candidates for successful separations on these CSPs. Hydrophobic interactions are important for enantiomeric separations in the RP mode where the H-bonding interactions between analytes and the chiral selectors are relatively weak. Me-TAG offers higher hydrophobicity, which can accentuate the interactions of analytes with hydrophobic moieties, but these interactions are not necessarily stereoselective. In the PO mobile phase, electrostatic/dipolar interactions between polar functional groups are the dominating interactions in chiral recognition. Another important factor is steric fit, which could be changed with every modification of the T structure. Therefore, substantial changes of enantioseparations were obtained within this studied group of CSPs. The PO mode was shown to be the most powerful mobile phase mode for enantiomeric separations on T-based stationary phases, mainly due to the improved efficiency. Methylation of the TAG proved to be a very useful tool for investigating the chiral recognition mechanism for this group of chiral selectors.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号