首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
For the detection of anabolic steroid residues in bovine urine, a highly sensitive liquid chromatographic/electrospray ionization tandem mass spectrometric (LC/ESI-MS/MS) method was developed using both positive and negative ionization. For four compounds the ESI mode was not sensitive enough and gas chromatographic/mass spectrometric GC/MS detection was therefore still necessary as a complementary method. The sample clean-up consisted of solid-phase extraction (SPE) on a C(18) column followed by enzymatic hydrolysis and a second solid-phase extraction on a combination of a C(18) and a NH(2) column. After this last SPE clean-up, the eluate was split into two equal aliquots. One aliquot was further purified and after derivatization used for GC/MS analysis. The other aliquot was analyzed with LC/MS/MS in both ESI+ and ESI- modes. The method was validated according to the European Commission Decision 2002/657/EC. Decision limits (CCalpha) were between 0.16 and 1 ng ml(-1) for the compounds detected with the LC/MS/MS method. The developed method is used in routine analysis in our laboratory.  相似文献   

2.
Over the last decade, time-of-flight (TOF) instruments have increasingly been used as quantitation tools. In addition, because of their high resolving power, they can be used for verification of empirical formulas. Historically, TOF instruments have had limited quantitation capabilities because of their narrow dynamic range. However, recent advances have improved these limitations. This review covers the rationale for using TOF for LC detection, and describes the many methods currently in the literature for the quantitation of pharmaceuticals, environmental pollutants, explosives and many phytochemicals.  相似文献   

3.
Fuh MR  Hsieh CJ  Tai YL 《Talanta》1999,49(5):158-1075
This paper describes a newly developed high performance liquid chromatography/electrospray/mass spectrometry (HPLC/ES/MS) method for the determination of flunarizine (FZ) in artificial cerebrospinal fluid. The optimization for the detection of FZ in biological fluid by LC/ES/MS was investigated. The effects of solvent composition, the addition of modifier and flow rate on the detection of FZ by ES/MS were examined. The detection limit of this method (0.8 nM) proved to be much better than previously reported methods. Satisfactory accuracy (98.2–106.0%) of this newly developed method was obtained. The application of this method was demonstrated by analyzing FZ in rat microdialysis samples.  相似文献   

4.
建立了超高效反相液相色谱-高分辨质谱方法以实现米格列奈及其3种异构体杂质的分离,以ACQUITY UPLC HSS T3(100 mm×2.1 mm,1.8 μ m)为色谱柱,以水-乙腈-正戊醇(75:25:1)(用甲酸调节pH至1.8)为流动相,流速为0.4 mL/min。根据Q Exactive四极杆/静电场轨道阱高分辨质谱的精确质量数及碎裂情况,发现了米格列奈及3种异构体存在碎片离子丰度的明显差异,确认其中两种为本次新发现的异构体杂质,并推断了米格列奈及3种异构体杂质可能的质谱裂解机理。经验证,该方法的灵敏度、重复性及线性均满足分析要求。在此基础上,对米格列奈异构体杂质的来源进行了探讨,发现异构体杂质1可在高温下降解产生,并对各企业的米格列奈钙原料样品进行了测定。  相似文献   

5.
Sparfloxacin, a fluoroquinolone antibiotic, is used for the treatment of bacterial infection. A quantification method using mass spectrometry was developed for the determination of sparfloxacin in rat plasma. After simple protein precipitation with acetonitrile, the analytes were chromatographed on a reversed‐phase C18 column and detected by liquid chromatography/tandem mass spectrometry with electrospray ionization. The accuracy and precision of the assay were in accordance with FDA regulations for validation of bioanalytical methods. This method was applied to measure the plasma sparfloxacin concentrations after a single oral administration of sparfloxacin in rats. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

6.
液相色谱/元素分析-同位素比值质谱联用法鉴定蜂蜜掺假   总被引:8,自引:0,他引:8  
费晓庆  吴斌  沈崇钰  丁涛  李丽花  路颖 《色谱》2011,29(1):15-19
采用液相色谱/元素分析-同位素比值质谱联用法(LC/EA-IRMS)对国内蜂蜜掺假情况进行了研究。基于测定得到的38个纯正蜂蜜样品的碳同位素δ13C值数据,提出了纯正蜂蜜样品的δ13C值要求: 蛋白质和蜂蜜的δ13C差值(Δδ13CP-H)≥~0.95‰,果糖和葡萄糖的δ13C差值(Δδ13CF-G)在~0.64‰至0.53‰范围内,各个组分间的δ13C最大差值(Δδ13Cmax)<2.09‰。对150个日常检测样品、蜂农和蜂蜜供应商的蜂蜜样品分别采用本文建立的LC/EA-IRMS和国家标准方法(EA-IRMS)进行鉴定,LC/EA-IRMS方法检出58个掺有C3或C4植物糖浆的阳性样品,而EA-IRMS方法仅检出7个掺有C4植物糖浆的阳性样品,可见新方法大大提高了对蜂蜜掺假的鉴别能力。  相似文献   

7.
Two model peptides, des-Arg1-bradykinin (DAB) and bradykinin (B), were cationized by Ag+ after their separation by reversed-phase liquid chromatography (RPLC) prior to mass spectrometry (MS). Silver nitrate solution was used as a post-column reagent. The RPLC and MS experimental conditions were optimized using flow injection in order to obtain sufficiently abundant silver adducts to permit MS/MS experiments. The use of water-methanol with 0.1% formic acid as mobile phase allowed a good chromatographic separation of the two peptides with a polymeric stationary phase and sufficiently abundant silver-containing adducts, [M + Ag + H]2+ and [M + 2Ag]2+. The gas-phase dissociation of [DAB + Ag + H]2+ and [DAB + 2Ag]2+ led to interpretable mass spectra during the on-line cationization experiment. Most of the ions obtained by dissociating [DAB + Ag + H]2+ and [DAB + 2Ag]2+ species are silver-containing ions but the ions produced depend on the parent. The ions coming from the dissociation of the doubly charged silver adducts [DAB + Ag + H]2+ or [DAB + 2Ag]2+ are of interest compared with those coming from the singly charged silver species or doubly charged protonated species. The fragmentation of the doubly charged silver adducts provides ions over the entire mass range. Although the presence of several prolines in des-Arg1-bradykinin prevents the formation of some expected ions, the observation of triplets [an-H + Ag]+, [bn-H + Ag]+ and [bn + OH + Ag]+ produced by the dissociation of on-line Ag(+)-cationized peptides could contribute to greater success of automatic sequencing of peptides.  相似文献   

8.
Aspartame is a widely used sweetener,the long-term safety of which has been controversial ever since it was accepted for human consumption.It is unstable and can produce some harmful degradation products under certain storage conditions.A high-performance liquid chromatography/tandem mass spectrometry method was developed for the simultaneous analysis of aspartame and its four degradation products,including aspartic acid,phenylalanine,aspartyl-phenylalanine and 5-benzyl-3,6-dioxo-2-piperazieacetic acid in water and in diet soft drinks.Aspartame and its four degradation products were quantified by a matrix matched external standard calibration curve with excellent correlation coefficients.The limits of detection were 0.16–5.8 mg/L,which exhibited higher sensitivity than common methods.This method was rapid,sensitive,specific and capable of eliminating matrix interferences.It was also applied to the study of the degradation of aspartame at various pH and temperatures.The results indicated that aspartame was partly degraded under strong acidic or basic conditions and the extent of degradation increased with increasing temperature.  相似文献   

9.
Zearalenone, a mycotoxin biosynthesized by various Fusarium fungi, is widely found as a contaminant in grains and animal feeds. This study describes a rapid and sensitive LC/MS/MS assay method for the quantification of zearalenone in rat serum. The assay was validated to demonstrate the specificity, linearity, recovery, lower limit of quantification (LLOQ), accuracy and precision. The multiple reaction monitoring was based on the transition of m/z 317.0 → 130.9 for zearalenone and 319.0 → 204.8 for zearalanone (internal standard). The assay utilized a single liquid–liquid extraction with t‐butyl methyl ether and isocratic elution, and the LLOQ was 0.5 ng/mL using 0.1 mL rat serum. The assay was linear over a concentration range from 0.5 to 200 ng/mL, with correlation coefficients >0.9996. The mean intra‐ and inter‐day assay accuracy was 101.2–112.9 and 96.3–108.0%, respectively. The mean intra‐ and inter‐day precision was between 1.3–7.6 and 3.6–10.6%, respectively. The developed assay was applied to a pharmacokinetic study after a bolus intravenous injection of zearalenone in rats. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

10.
Ma Y  Zhang W  Wei J  Niu M  Lin H  Qin W  Zhang Y  Qian X 《色谱》2011,29(3):205-211
复杂肽段混合物的有效分离是高覆盖率地鉴定蛋白质混合物的前提。“鸟枪法”(Shotgun)蛋白质组学研究策略通常采用蛋白酶切、二维液相色谱-串联质谱分析肽段混合物从而鉴定蛋白质,其中高效率地分离肽段混合物是关键步骤之一。本文通过pH梯度结合有机溶剂梯度的反相高效液相色谱(RP-HPLC)进行一维液相色谱分离,按等时间间隔收集馏分并将一个梯度的前段的一个馏分与后段一个馏分混合,然后进行纳升级液相色谱-质谱联用(nanoRPLC-MS/MS)分析。将该方法应用于酵母蛋白质的分离和鉴定,实验结果为: 与常规的强阳离子色谱-反相液相色谱-质谱分离鉴定方法相比,采用pH梯度结合有机相梯度的RP-HPLC-RPLC-MS分离鉴定方法多鉴定到567个酵母蛋白质(簇,含有3035个唯一肽段);其中鉴定到肽段的pI分布范围为3.42~12.01,相对分子质量范围为587.67~3499.79;蛋白质的pI分布范围为3.82~12.19,相对分子质量范围为3446.55~432905。该结果表明这种方法在复杂体系蛋白质组分离鉴定中具有明显的优势,在蛋白质组学研究中有较好的应用前景。  相似文献   

11.
A novel method for the analysis of endogenous lipids and related compounds was developed employing hydrophilic interaction liquid chromatography with electrospray ionization tandem mass spectrometry. A hydrophilic interaction liquid chromatography with carbamoyl stationary phase achieved clear separation of phosphatidylcholine, lysophosphatidylcholine, sphingomyelin, ceramide, and mono‐hexsosyl ceramide groups with good peak area repeatability (RSD% < 10) and linearity (R2 > 0.99). The established method was applied to human plasma assays and a total of 117 endogenous lipids were successfully detected and reproducibly identified. In addition, we investigated the simultaneous detection of small polar metabolites such as amino and organic acids co‐existing in the same biological samples processed in a single analytical run with lipids. Our results show that hydrophilic interaction liquid chromatography is a useful tool for human plasma lipidome analysis and offers more comprehensive metabolome coverage.  相似文献   

12.
The use of open-access mass spectrometry to monitor synthetic chemistry reactions, and also the integrity and purity of new chemical entities, has been a part of the medicinal chemist's tool-box for more than 5 years. Originally in our group at Wyeth Research there were two open-access methods available to the chemists, flow injection analysis (FIA) and liquid chromatography/mass spectrometry (LC/MS). The FIA method was approximately 3 min long, while the LC/MS method was approximately 20 min long (including an 8 min gradient). Within the first 2 years, the total number of open-access analyses increased by approximately 125%. It is interesting, however, that the number of LC/MS analyses increased by more than 285%. This is attributed to the fact that the chemists began using the LC/MS data to monitor reactions and also to check final product integrity and purity. In addition, the number of chemists performing parallel synthesis reactions has increased; thus, individual chemists can produce sample sets of up to 100 vials. This paper describes the implementation of new methodology, which accommodates the need for much faster run times and also the ability to acquire alternating positive and negative ion spectra within the same run. In addition, the instrument has been configured to e-mail the resulting processed data report to the submitting chemist. Several methods have been developed, including structure elucidation using in-source collision-induced dissociation (CID) and night-time analysis. The LC/MS methods for this system are described herein and are applicable to both industrial and academic synthetic chemistry optimization efforts.  相似文献   

13.
Paraquat (PQ) and diquat (DQ) in human whole blood and urine were analyzed by high-performance liquid chromatography/tandem mass spectrometry (HPLC/MS/MS) with positive ion electrospray ionization (ESI). The compounds were extracted with Sep-Pak C18 cartridges from whole blood and urine samples containing ethyl paraquat as an internal standard. The separation of PQ and DQ was carried out using ion-pair chromatography with heptafluorobutyric acid in 20 mM ammonium acetate and acetonitrile gradient elution for successful coupling with MS. Both compounds formed base peaks due to [M-H]+ ions by HPLC/ESI-MS and the product ions produced from each [M-H]+ ion by HPLC/MS/MS. Selective reaction monitoring (SRM) showed much higher sensitivity for both body fluids. Therefore, a detailed procedure for the detection of compounds by SRM with HPLC/MS/MS was established and carefully validated. The recoveries of PQ and DQ were 80.8-95.4% for whole blood and 84.2-96.7% for urine. The calibration curves for PQ and DQ showed excellent linearity in the range of 25-400 ng ml(-1) of whole blood and urine. The detection limits were 10 ng ml(-1) for PQ and 5 ng ml(-1) for DQ in both body fluids. The intra- and inter-day precision for both compounds in whole blood and urine samples were not greater than 13.0%. The data obtained from the determination of PQ and DQ in rat blood after oral administration of the compounds are also presented.  相似文献   

14.
In this review, instrumental aspects of comprehensive two-dimensional liquid chromatography coupled with mass spectrometry are presented. The milestones of LC×LC are briefly summarized. Instrument configuration, selection of experimental conditions, the different interfaces used in the system and the current applications of LC×LC–MS systems are described.  相似文献   

15.
Abstract

Punica granatum L., commonly known as pomegranate, is an ancient fruit widely consumed all over the world as fresh fruit or juice. In addition, it is extensively used in therapeutic formulas, cosmetics and food seasonings. The fruit is native to Afghanistan, Iran, China and the Indian sub-continent. The pomegranate market has steadily grown, presumably due to the increasing demand of health-conscious consumers for products with potential beneficial effects on human health, due to the synergistic presence of a unique and complex phytochemical composition that enclose anthocyanins, phenolic acids and hydrolysable tannins. Conventionally, for their analysis liquid chromatography is employed even though it can present some drawbacks in terms of resolving power. In this contribution, as a valuable alternative, comprehensive two-dimensional liquid chromatography with “shifted gradients” in the second dimension, was applied for the characterization of three pomegranate samples, leading to the identification of 37 different polyphenolic compounds.  相似文献   

16.
Herein, an improved method for detecting the endocrine-disrupting chemicals in milk is presented, which is based on high performance liquid chromatography tandem mass spectrometry, coupled with a quick, effective, and safe method. The linearity of the proposed method was in the range of 0.05–100 μg/L, and all correlation coefficients were ≥0.9973. At three concentration levels, the spiked recoveries ranged from 77.7 to 107.5%, relative standard deviations ranged from 0.2 to 14.6%, limits of quantitation ranged from 0.1 to 40 μg/kg, limits of detection ranged from 0.03 to 13.3 μg/kg. The proposed method for the identification and quantitation of 26 endocrine disruptors present in milk is not only easy, fast, and cost-efficient but also provides a reference for the detection of various endocrine disruptors in milk and other dairy products.  相似文献   

17.
The coupling of column liquid chromatography on-line with mass spectrometry using post-column phosphate suppression is described. A membrane suppressor is used to remove the non-volatile phosphate ions from the mobile phase after the chromatographic separation prior to introduction into the mass spectrometer. Using post-column phosphate suppression by a membrane device phosphate concentrations up to 10 mM phosphate, at a mobile phase flow rate of 0.1 ml/min, could be removed for more than 99% without any decay of the sensitivity of the MS detection. Using a new antidepressant tetracyclic basic compound, ORG 4428, and some structure related compounds as model compounds electron impact as well as chemical ionisation spectra of all compounds could be obtained. The set-up could be used for several weeks running, using a phosphate containing mobile phase, without any loss of performance.  相似文献   

18.
A mass spectrometric-based procedure for anthocyanin profiling was set up to distinguish authentic Vitis vinifera from hybrid red grapevine cultivars. 3-O-Monoglucoside and the related acetyl-, p-coumaryl- and caffeoyl-monoglucoside anthocyanins occurred only in Vitis vinifera, whereas 3,5-O-diglucoside and the substituted acetyl-, p-coumaryl-, feruloyl- and caffeoyl-diglucoside anthocyanins were the additional pigments in hybrid grapevines. The procedure was applied expressly to identify red grape cultivars based on the anthocyanin chemo-type determination. In particular, a red grape cultivar, having 3,5-O-diglucoside anthocyanins and a novel class of anthocyanin monoglucosides, such as cyanidin-3-O-, cyanidin-3-O-(6-O-acetyl)- and cyanidin-3-O-(6-O-p-coumaryl)pentoside, was classified as hybrid. A second vine cultivar, characterized exclusively by 3-O-monoglucoside anthocyanins, was included among the Vitis vinifera species. Anthocyanin profiling by mass spectrometry could represent the core of a chemotaxonomic procedure for distinguishing American and European grapevines based on the identification of post-synthetic anthocyanidin modification.  相似文献   

19.
Summary Microcolumn liquid chromatography (LC) combined with fast-atom-bombardment mass spectrometry (FABMS) was applied to the analysis of nonionic detergents. The porous silver filter attached to the top of the capillary fused-silica tubing worked as the interface for coupling of micro LC and FABMS.  相似文献   

20.
Tetrodotoxin (TTX) exhibits the therapeutic potential in blocking pain and in low doses can safely relieve severe pain. The urinary excretion profiles of TTX in humans have not been reported due to the extremely low lethal dose. In this study, a rapid and specific method based on protein precipitation coupled to liquid chromatography tandem mass spectrometry was developed to determine the level of TTX in human urine samples. 11-Deoxytetrodotoxin was used as an internal standard (IS). Multiple reaction monitoring mode was used for quantification using target fragment ions m/z 320.0 → 162.1 for TTX and m/z 304.0 → 176.0 for 11-deoxyTTX. The separation of analytes was achieved on a hydrophilic interaction liquid chromatography column (250 × 4.6 mm, 5.0 μm). The mobile phase consisted of 5 mM ammonium formate in water (pH = 4.50) and 5 mM ammonium formate in acetonitrile (pH = 4.50). The flow rate was set at 0.80 mL/min in a gradient condition. Calibration plots were linear throughout the range 0.986–98.6 ng/mL of TTX in human urine. The intra-assay accuracies and precisions were within the acceptable range. The method was successfully applied to a urinary excretion study after intravenous administration of TTX to healthy volunteers. The developed method will be helpful for future pharmacological studies of TTX.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号