首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
氢化物发生-原子荧光光谱法测定中草药中的微量砷   总被引:8,自引:0,他引:8  
研究了氢化物发生-原子荧光光谱法测定中草药中微量砷的方法的最佳条件,以50g/L硫脲 50g/L抗坏血酸为预还原抗干扰剂,测定了10种中草药药品中的砷,方法检出限(3σ)为0.103μg/L,相对标准偏差为1.6%-3.2%,回收率为89.2%-112%。  相似文献   

2.
A new method was developed for simultaneous determination of trace arsenic and antimony in Chinese herbal medicines by hydride generation-double channel atomic fluorescence spectrometry with a Soxhlet extraction system and an n-octanol-water extraction system, respectively. The effects of analytical conditions on the fluorescence intensity were investigated and optimized. A water-dissolving and methanol-water-dissolving capability were compared. The contents of different species in five Chinese herbal medicines and their decoctions were analyzed. The concentration ratios of n-octanol-soluble As or Sb to water-soluble As or Sb were related to the kinds of medicine and the acidity of the decoction. Soxhlet extraction was found to be an effective method for plants pretreatment for determination of arsenic and antimony species in Chinese herbs; the interferences of coexisting ions were evaluated. The proposed method has the advantages of simple operation, high sensitivity and high speed, with 3σ detection limits of 0.094 μg g−1 for As(III), 0.056 μg g−1 for total As, 0.063 μg g−1 for Sb(III) and 0.019 μg g−1 for total Sb in a 1.0 g of the sample.  相似文献   

3.
A new method is proposed for simultaneous determination of traces of arsenic (As) and selenium (Se) in biological samples by hydride-generation double-channel non-dispersive atomic-fluorescence spectrometry (HG-AFS) from tartaric acid media. The effects of analytical conditions on fluorescence signal intensity were investigated and optimized. Interferences from coexisting ions were evaluated. Under optimum conditions linear response ranges above 20 g L–1 for As and 32 g L–1 for Se were obtained with detection limits of 0.13 and 0.12 g L–1, respectively. The precision for elevenfold determination of As at the 4 g L–1 level and of Se at the 8 g L–1 level were 2.7 and 1.9% (RSD), respectively. Recoveries of 92.5–95.5% for As and 101.2–108.4% for Se were obtained for four biological samples and two certified biological reference materials. The proposed method has the advantages of simple operation, high sensitivity, and high efficiency; it was successfully used for simultaneous determination of As and Se in biological samples.  相似文献   

4.
Simultaneous determination of As and Sb by hydride generation atomic fluorescence spectrometry was developed with the dielectric barrier discharge plasma as the hydride atomizer. The low-temperature and atmospheric-pressure micro-plasma was generated in a quartz cylindrical configuration device, which was constructed by an axial internal electrode and an outer electrode surrounding outside of the tube. The optimization of the atomizer construction and parameters for hydride generation and fluorescence detection systems were carried out. Under the optimized conditions, the detection limits for As and Sb were 0.04 and 0.05 μg L−1, respectively. In addition, the applicability of the present method was confirmed by the detection of As and Sb in reference materials of quartz sandstone (GBW07106) and argillaceous limestone (GBW07108). The present work provided a new approach to exploit the miniaturized hydride generation dielectric barrier discharge atomic fluorescence spectrometry system for simultaneous multi-element determination.  相似文献   

5.
A digestion mixture of H2SO4/HNO3/H2O2/HF/V2O5 was investigated for decomposition of plant samples and sensitive detection of selenium was achieved by hydride generation atomic fluorescence spectrometry (HG-AFS). The method was found to be accurate and reproducible, with a low detection limit (DL) (0.14 ng g−1 solution). The repeatability of the determination was mostly around 10%, the reproducibility over a period of 8 months for determination of selenium in the standard reference material Trace Elements in Spinach Leaves, NIST 1570a, was 9% and the relative measurement uncertainty was 7% using a coverage factor of 2.3 at 95% probability. The average recovery of the whole procedure was 90%. The characteristics of this method are simple and inexpensive equipment, low consumption of chemicals and the ability to analyse many samples in a short time. The whole procedure was carried out in the same PTFE tube, and in addition only a simple cleaning procedure is needed. As a consequence of all these advantages, the described method is suitable for environmental and nutritional studies. The selenium content was determined in 44 vegetable samples from different regions of Slovenia and the contents found were in the range 0.3-77 ng g−1 wet weight.  相似文献   

6.
In this work, the determination of total As in seawater by hydride generation atomic fluorescence spectrometry was studied. The influence of the chemical, flow and instrumental parameters were investigated and optimized. The pre-reduction of As(V) to As(III) was performed using KI plus ascorbic acid in 3.5 mol L− 1 HCl medium. No multiplicative interference was present and external aqueous calibration could be used. The limit of detection was 36 ng L− 1, while the repeatability was 2% (n = 10), at a 500 ng L− 1 concentration level. The sample throughput was 15 h− 1 if triplicate measurements were made. The accuracy was assessed by the analysis of a seawater certified reference material and excellent agreement between the obtained and certified values was verified. The procedure was used for the analysis of seawater offshore samples collected at the Brazilian coast and results ranging from 860 to 1200 ng L− 1 were found.  相似文献   

7.
Li ZX  Guo YA 《Talanta》2005,65(5):1318-1325
A new and sample technique for the simultaneous determination of trace arsenic, antimony, bismuth and selenium in biologic samples by hydride generation-four-channel nondispersive atomic fluorescence spectrometry was development. The conditions of instrumentation and hydride generation of arsenic, antimony, bismuth and selenium were optimized. For reducing hexavalent Se to the tetravalent state was to heat the sample with 6 mol l−1 HCl, and then pre-reducing pentavalent As and Sb to the trivalent state was achieved by the addition of 0.05 mol l−1 thiourea. The interferences of coexisting ions were evaluated. Under optimal conditions, the detection limits for As, Sb, Bi and Se were determined to be 0.03, 0.04, 0.04 and 0.03 ng ml−1, respectively. The precision for seven replicate determinations at the 5 ng ml−1 of As, Sb, Bi and Se were 0.9, 1.2, 1.3 and 1.5% (R.S.D.), respectively. The proposed method was successfully applied to the simultaneous determination of As, Sb, Bi and Se in a series of Chinese certified biological reference materials using simple aqueous standard calibration technique, the results obtained are in good agreement with the certified values.  相似文献   

8.
建立了一种顺序注射氢化物发生-原子荧光光谱法测定试样中Se和As的方法,同时讨论了共存离子的干扰情况.在最佳实验条件下,Se和As的检出限分别为0.16和0.095 μg/L,加标回收率为92.4%~104.7%.  相似文献   

9.
Hydride generation atomic fluorescence spectrometry was for the first time utilized to determine trace toxic element arsenic in the skeleton fossils of four dinosaurs unearthed in Sichuan Province of China. The instrumental limit of detection (LOD) for arsenic was 0.03 μg/L under optimal experimental conditions, which compared favorably to that by ICP-AES and ETAAS. The samples were digested with aqua regia in boiling water bath. The recoveries of standard addition were found to be from 97 to 109%, and the analytical results were found in good agreement with those by ICP-AES. It is a simple, reliable, sensitive yet relatively inexpensive analytical method, compared to ICP-AES, ICP-MS or ETAAS. Interesting analytical results were found that the arsenic concentrations were all abnormally high in the skeleton fossils. The established analytical method and the analytical results may be helpful in revealing the mystery of the mass extinction of the dinosaur fauna. The analytical results, together with other data available to date, supported the argument that the arsenic toxicosis could be a contributing factor for the mass extinction of the dinosaur fauna in Sichuan Province of China.  相似文献   

10.
Xiaohong Li  Yingying Su  Kailai Xu  Xiandeng Hou  Yi Lv   《Talanta》2007,72(5):1728-1732
A simple, sensitive and interference-free method was proposed for the determination of arsenic, based on the generation of volatile arsenic trichloride coupled with atomic fluorescence spectrometry. Thiourea, together with l-ascorbic acid, was used to reduce As(V) to As(III), and the chloride generation was based on the reaction between As(III) and hydrochloric acid. Under the optimized experimental conditions, the present procedure allows for the quantification of arsenic in the concentration range of 0.01–4.0 mg L−1, with a limit of detection (3σ) of 6.0 μg L−1. The relative standard deviation (R.S.D.) is 4.0% for 0.1 mg L−1 arsenic (n = 7). Finally, the proposed method was successfully applied to the determination of arsenic in several certified reference samples (stainless steel, alloy steel, copper alloy and water sample) and real samples (brass material and spiked cobalt material), with analytical results well-agreed with those by ICP-MS.  相似文献   

11.
A novel method for speciation analysis of inorganic arsenic was developed by on-line hyphenating microchip capillary electrophoresis (chip-CE) with hydride generation atomic fluorescence spectrometry (HG-AFS). Baseline separation of As(III) and As(V) was achieved within 54 s by the chip-CE in a 90 mm long channel at 2500 V using a mixture of 25 mmol l(-1) H3BO3 and 0.4 mmol l(-1) CTAB (pH 8.9) as electrolyte buffer. The precisions (RSD, n=5) ranged from 1.9 to 1.4% for migration time, 2.1 to 2.7% for peak area, and 1.8 to 2.3% for peak height for the two arsenic species at 3.0 mg l(-1) (as As) level. The detection limits (3sigma) for As(III) and As(V) based on peak height measurement were 76 and 112 microg l(-1) (as As), respectively. The recoveries of the spikes (1 mg l(-1) (as As) of As(III) and As(V)) in four locally collected water samples ranged from 93.7 to 106%.  相似文献   

12.
A new multisyringe flow injection system for total inorganic selenium determination by hydride generation-atomic fluorescence spectrometry (HGAFS) has been proposed. The flow methodology is based on the simultaneous injection of sample in the acid media (50% HCl), a reducing sodium tetrahydroborate solution (0.18%) and a solution of hydrochloric acid (50%) which are dispensed into a gas-liquid separation cell by using a multisyringe burette coupled with one multiport selection valve. The usage of the time-based injection increases the sample throughput and provides precise known volumes of sample. The hydride of selenium is delivered into the flame of an atomic fluorescence spectrometer by means of an argon flow. A hydrogen flow has been used to support the flame.The technique can be applied over a wide range of concentrations of selenium between 0.1 and 3.5 μg l−1 with good repeatability (relative standard deviation (R.S.D.) values 4.6-7% for 1 μg l−1 of Se). The detection limit of the developed technique (3σb/S) was 0.01 μg l−1. A sample throughput was 28 samples per hour (84 injections). The multisyringe technique has been validated by means of reference solid (sea lettuce) and water (hard drinking water) materials with good agreement with certified values. The analytical features were compared with those obtained by using of the commercial flow injection analysis (FIA) system. The proposed method provides a higher sampling frequency and a significant reduction of reagent and sample consumption in front the flow injection application.  相似文献   

13.
A software-controlled time-based multisyringe flow-injection system for total inorganic arsenic determination by hydride generation atomic fluorescence spectrometry (HGAFS) has been developed. By using a multisyringe burette coupled with one multiport selection valve, the time-based injection provides precise known volumes of sample, a reducing sodium tetrahydroborate solution and a pre-reducing solution which are dispensed into a gas-liquid separation cell. An argon flow delivers the arsine into the flame of an atomic fluorescence spectrometer. A hydrogen flow has been used to support the flame.Linear calibration graphs for arsenic concentrations between 0.25 and 12 μg l−1 were obtained. The detection limit of the proposed technique (3σb/S) was 0.07 μg l−1. A sample throughput of 36 samples/h (108 injections) has been achieved. The proposed technique has been validated by means of reference solid and water materials with good agreement with the certified values. This method was compared with those reported in previous sequential injection analysis (SIA) and flow-injection analysis (FIA) systems. The proposed method offers a number of advantages in front the usual AFS applications, which are mainly a higher sampling frequency and a significant reduction in reagent consumption.  相似文献   

14.
A highly sensitive procedure has been developed for total arsenic and antimony determination in milk samples by hydride generation atomic fluorescence spectrometry after microwave-assisted sample digestion. The discrete introduction of 2 ml of digested sample in the automated continuous flow hydride generation system allows us to reduce drastically the sample and HCl consume and to determine several elements from a same sample digestion. The method provides detection limits of 0.006 and 0.003 ng ml−1, a sensitivity of 2390 and 2840 fluorescence units per ng ml−1 for As and Sb respectively, and average relative standard deviation of 2.3% for As and 4.8% for Sb. The analysis of cow milk samples, obtained from the Spanish market evidenced the presence of As at concentration levels from 3.4 to 11.6 ng g−1 and Sb levels from 3.5 to 11.9 ng g−1, thus in a proportion near to 1:1, which is in contrast with the 10:1 natural ratio between As and Sb and could evidence the effect of the introduction of new alloys and polymer materials in the industrial process of milk. The method was validated by the comparison of data found for commercial samples by using the proposed procedure and reference methods based on dry-ashing and AFS, and microwave-assisted digestion and inductively coupled plasma mass spectrometry determination.  相似文献   

15.
A systematic study of antimony reduction prior to its determination by hydride generation atomic fluorescence spectrometry (HG-AFS) was carried out. The efficiency of l-cysteine, potassium iodide and potassium iodide/ascorbic acid was studied for this purpose. The hydride generation step was optimised in the presence of those pre-reductors. From the results, l-cysteine was found to be the most suitable pre-reducing agent. Methodology was validated, obtaining detection limits lower than 90 ng l−1 and repeatability and reproducibility better than 3% R.S.D. and 5% R.S.D., respectively, in all cases. In order to evaluate the methodology developed and the influence of the matrix, recovery from waters from different sources was tested by HG-AFS and also by inductively coupled plasma mass spectrometry (ICP-MS). Accuracy was assessed by analysing three water reference materials at different antimony concentration levels. The high sensitivity of the developed methodology enables it to be applied for monitoring drinking waters according to the maximum admissible concentration of antimony established by the EU Directives.  相似文献   

16.
An integrated electrochemical hydride generation cell, mainly composed of three components (a gas liquid separator, a graphite tube cathode and a reticulate Pt wire anode), was laboratory constructed and employed for the detection of arsenic by coupling to atomic fluorescence spectrometry. This integrated cell was free of ion-exchange membrane and individual anolyte, with the virtues of low-cost, easy assembly and environmental-friendly. Using flow injection mode, the sample throughput could come to 120 h−1 attributed to the small dimension of the cathode chamber. The operating conditions for the electrochemical hydride generation of arsenic were investigated in detail and the potential interferences from oxygen or various ions were also evaluated. Under the optimized conditions, no obvious oxygen quenching effects were observed. The limit of detection of As (III) for the sample blank solution was 0.2 ng mL−1 (3σ) and the relative standard deviation was 3.1% for nine consecutive measurements of 5 ng mL−1 As (III) standard solution. The calibration curve was linear up to 100 ng mL−1. The accuracy of the method was verified by the determination of arsenic in the reference materials GBW08517 (Laminaria Japonica Aresch) and GBW10023 (Porphyra crispata) and the developed method was successfully applied to determine trace amounts of arsenic in edible seaweeds.  相似文献   

17.
微波消解-氢化物发生原子荧光法同时测定土壤中的砷汞   总被引:10,自引:0,他引:10  
建立了微波消解-氢化物发生原子荧光法同时测定土壤中As、Hg的分析方法。用体积分数35%的王水作为消解溶剂,在设定的微波消解条件下,可以将土壤中的As、Hg提取完全,有效解决了消解液中剩余酸过多的问题。方法用体积分数5%的HCl作为反应介质,20 g/L NaBH4作为还原剂。通过测定国家标准参考物质和加标回收实验,对方法进行了验证。已用于土壤中As、Hg的测定。  相似文献   

18.
应用自行设计的化学蒸气发生-四通道无色散原子荧光光谱仪,建立了同时测定水样中As、Sb、Se、Hg的新方法.在实验中优化了四元素同时化学蒸气发生条件和测定的最佳工作参数.在样品预处理阶段用HCl将Se6+还原为Se4+,然后用质量浓度5 g/L硫脲将As5+和Sb5+还原为As3+和Sb3+.在最佳条件下,方法对As、Sb、Se、Hg的检出限分别为0.05、0.03、0.05、0.01 ng/mL(3d);RSD分别为0.42%、0.74%、0.97%、1.0%(对5 ng/mL As、Sb、Se和0.5ng/mL Hg混合标准,n=7).用所建立的方法对不同类型水样中的As、Sb、Se、Hg进行了同时测定,测定结果与用标准方法测定所得结果之间无明显差异,各元素的加标回收率在93%~105%.  相似文献   

19.
Dong LM  Yan XP 《Talanta》2005,65(3):627-631
A new flow injection on-line sequential extraction procedure coupled with hydride generation atomic fluorescence spectrometry (HG-AFS) was developed for rapid and automatic fractionation of arsenic in soils. The developed methodology involved a three-step sequential extraction procedure with deionized water, KOH solution, and HCl solution. 25 mg of the soil sample packed into a microcolumn (4 mm i.d. × 3 cm long) was dynamically extracted by continuously pumping each individual extractant through the column. The extracted arsenic solution was merged with 4% (m/v) K2S2O8 solution for on-line oxidation of all arsenic species into AsV. The total extracted arsenic was on-line detected by HG-AFS, and quantitated using an on-line standard addition calibration strategy. The total time for the three-step sequential extraction and on-line detection lasted only 10 min. The developed methodology offers several advantages over conventional batch sequential extraction protocols, including minimization of readsorption/redistribution problem, improvement of accuracy, high speed, less amounts of sample/reagents required, less risk of contamination and analyte loss. The developed methodology was successfully applied to the fractionation of arsenic in certified soil reference materials.  相似文献   

20.
A rapid, high sensitivity method has been developed for the determination of As(III), As(V), Sb(III) and Sb(V) in milk samples by using hydride generation atomic fluorescence spectrometry. The method is based on the leaching of As and Sb from milk through the sonication of samples with aqua regia followed by direct determination of the corresponding hydrides both before and after reduction with KI. It was confirmed by recovery experiments on spiked commercially available samples that neither the reduced nor the oxidized forms of the elements under study or mixtures of the two oxidation states were modified by the room temperature sample treatment with aqua regia. The methodologies developed provided 3σ limit of detection values of 8.1, 10.3, 5.4 and 7.7 ng l−1 for As(III), As(V), Sb(III) and Sb(V) in the diluted samples. Average relative standard deviation values of 5.7, 5.5, 8.2 and 4.7% were found for determination of As(III), As(V), Sb(III) and Sb(V) in commercially available samples of different composition and origin containing from 3.5 to 13.6 ng g−1 total As and from 4.9 to 11.8 ng g−1 total Sb, it being confirmed that As(V) and Sb(V) are the main species present in the samples analyzed (62±5 and 73±5%, respectively). The time required to determine As and Sb species in milk involves 10 min sonication and 30 min prereduction but these steps can be carried out for several sample simultaneously. Additionally the fluorescence measurement step involves less than 20 min for three replicates of all the four measurements required. So, in less than 2 h it is possible to determine the content of As(III), As(V), Sb(III) and Sb(V) in four samples.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号