首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
Cu nanoclusters were electrochemically deposited on the film of a Nafion-solubilized multi-wall carbon nanotubes (CNTs) modified glassy carbon electrode (CNTs-GCE), which fabricated a Cu-CNTs composite sensor (Cu-CNTs-GCE) to detect glucose with non-enzyme. The linear range is 7.0×10-7 to 3.5×10-3 mol/L with a high sensitivity of 17.76μA/(mmol L), with a low detection limit 2.1×10-7 mol/L, fast response time (within 5 s), good reproducibility and stability.  相似文献   

2.
Based on the fact that some metal ions can catalyze the chemiluminescence(CL)reaction of luminol with K_3Fe(CN)_6,a novel capillary electrophoresis CL method was developed for the determination of Co(Ⅱ)and Cu(Ⅱ).The separation was carried out with a 10 mmol/L sodium acetate solution containing 0.8 mmol/L luminol and 2.0 mmol/Lα-HIBA(adjusted to pH 4.8 by HAc solution).The post-capillary reagent was 2.0 mmol/L K_3Fe(CN)_6 which was adjusted to pH 13.0 by NaOH solution.Under the optimum conditions,the detection limits(S/N=3)for Co(Ⅱ)and Cu(Ⅱ)were 7.5×10~(-11)mol/L and 7.5×10~(-9)mol/L,with the linear range of 7.5×10~(-9)mol/L to 1.0×10~(-6)mol/L and 7.5×10~(-8)mol/L to 5.0×10~(-5)mol/L, respectively.  相似文献   

3.
A sensitive flow injection chemiluminescence method has been developed for the detection of resveratrol in red wine based on the fact that resveratrol can greatly enhance chemiluminescence reaction between KMnO_4 and HCHO in sulfuric acid medium. Analytes were pre-concentrated on solid sorbents (C_(18) solid-phase extraction cartridges).Under the optimum conditions,the proposed method allows the measurement of resveratrol over the range of 1.32×10~(-8) to 1.32×10~(-5) mol/L with a detection limit of 3.30×10~(-9) mol/L,and the relative standard deviation for 1.32×10~(-5) mol/L resveratrol (n=11) is 3.8%.This method has been successfully applied for the determination of the resveratrol in red wine.Furthermore,the possible reaction mechanism was also discussed.  相似文献   

4.
The electrochemiluminescent (ECL) behavior of lucigenin on a multi-wall carbon nanotube/nano-Au modified glassy carbon electrode (MWNT/nano-Au/GCE) was studied in this paper. Compared with the bare GCE, the ECL intensity of lucigenin can be greatly enhanced at MWNT/nano-Au/GCE. Based on the fact that superoxide dimutase (SOD) could obviously inhibit the ECL of lucigenin at MWNT/nano-Au/GCE, a sensitive ECL biosensor for determination of SOD was developed with a wide linear range of 5.0 × 10−8–5.0 × 10−6 mol/L with detection limit of 2.5 × 10−8 mol/L.  相似文献   

5.
Gold nanoparticles/carbon nanotubes (Au-NPs/CNTs) composites were rapidly synthesized by microwave radiation, and firstly applied for the determination of trace mercury(II) by anodic stripping voltammetry (ASV). The structure and composition of the synthesized Au-NPs/CNTs nanocomposites were characterized by transmission electron microscopy (TEM), energy dispersive X-ray spectroscopy (EDX), UV–vis absorption spectroscopy and cyclic voltammetry. Au-NPs/CNTs nanocomposites modified glassy carbon electrode (Au-NPs/CNTs/GCE) exhibited excellent performance for Hg(II) analysis. A wide linear range (5 × 10−10–1.25 × 10−6 mol/L) and good repeatability (relative standard deviation of 1.84%) were obtained for Hg(II) detection. The limit of detection was found to be 3 × 10−10 mol/L (0.06 μg/L) at 2 min accumulation, while the World Health Organization’s guideline value of mercury for drinking water is 1 μg/L, suggesting the proposed method may have practical utility.  相似文献   

6.
A novel selective thiocyanate PVC membrane electrode based on bis-bebzoin-semitriethylenetetraamine binuclear copper(II) [Cu(II)2–BBSTA] as neutral carrier is reported, which displays an anti-Hofmeister selectivity sequence in following order: SCN > ClO4 > I >Sal >SO32− >NO3 > H2PO4 > Cl >NO2 > SO42−. The electrode exhibits Nernstian potential linear range to thiocyanate from 1.0 × 10−1 to 9.0 × 10−7 mol/l with a detection limit 7.0 × 10−7 mol/l and a slope of −57.0 mV/decade in pH 5.0 of phosphorate buffer solution at 25 °C. The response mechanism is discussed in view of the AC impedance technique and the UV spectroscopy technique. From comparison of potentiometric response characteristics between the binuclear metallic complex copper(II) [Cu(II)2–BBSTA] and mononuclear copper(II) metallic complex [Cu(II)–BBSDA], an enhanced response towards thiocyanate from the electrode based on binuclear metallic complex copper (II) [Cu(II)2–BBSTA] was observed. The electrode based on binuclear copper(II) compound was used to determine the thiocyanate content in waste water with satisfactory results.  相似文献   

7.
A thionine modified aligned carbon nanotubes (ACNTs) electrode was fabricated and was used to electrochemically determine nitrite. The thionine modified ACNTs electrode exhibited enhanced electrocatalytic behavior to the oxidation of nitrite. The electrochemical mechanism of the thionine/ACNTs electrode towards the oxidation of nitrite was discussed. The thionine modified ACNTs electrode exhibited fast response towards nitrite with a detection limit of 1.12 × 10−6 mol  L−1 and a linear range of 3 × 10−6 – 5 × 10−4 mol  L−1. The proposed method was successfully applied in the detection of nitrite in real samples.  相似文献   

8.
Zirconium(IV) phosphosulphosalicylate, a cation exchanger was synthesized by mixing zirconium oxychloride to a mixture of 5-sulphosalicylic acid and phosphoric acid. The material showed good efficiency for the preparation of an ion-selective membrane electrode. The membrane was characterized affinity for Pb(II) ions. Due to its Pb(II) selective nature, the ion-exchanger was used as an electroactive by XRD and SEM analysis. The electrode responds to Pb(II) ions in a linear range from 1 × 10−5 to 1 × 10−1 M with a slope of 43.8 mV per decade change in concentration with detection limit of 4.78 × 10−6 M. The life span of electrode was found to be 90 days. The proposed electrode showed satisfactory performance over a pH range of 4.0–6.5, with a fast response time of 15 s. The sensor has been applied to the determination of Pb(II) ions in water samples of different origins. It has also been used as indicator electrode in potentiometric titration of Pb(II) ion with EDTA.  相似文献   

9.
A new PVC membrane based strontium(II) ion-selective electrode has been constructed using acetophenone semicarbazone as a neutral carrier. The sensor exhibits a Nerstian response for strontium(II) ion over a wide concentration range 1.0 × 10−2–1.0 × 10−7 M with the slope of 29.4 mV/per decade. The limit of detection was 2.7 × 10−8 M. It was relatively fast response time (<10 s for concentration ⩾1.0 × 10−3 and <15 s for concentration of ⩾1.0 × 10−6 M) and can be used for 8 months without any considerable divergence in potentials. The proposed sensor revealed relatively good selectivity and high sensitivity for strontium(II) over a mono, di, trivalent cation and can be used in a pH range of 2.5–10.5. It was also successfully used as an indicator electrode in potentiometer titration and in the analysis of concentration in various real samples.  相似文献   

10.
A novel chitosan-carboxylated multiwall carbon nanotube modified glassy carbon electrode (MC/GCE) was developed to investigate the oxidation behavior of nitrite using cyclic voltammetry and differential pulse voltammetry modes. The electrochemical mechanism of the MC/GCE towards nitrite was discussed. The MC/GCE exhibited fast response towards nitrite with a detection limit of 1 × 10−7 mol l−1 and a linear range of 5 × 10−7–1 × 10−4 mol l−1. The possible interference from several common ions was tested. The proposed method was successfully applied in the detection of nitrite in real samples.  相似文献   

11.
This work reports on a novel chitosan–hematite nanotubes composite film on a gold foil by a simple one-step electrodeposition method. The hybrid chitosan–hematite nanotubes (Chi–HeNTs) film exhibits strong electrocatalytic reduction activity for H2O2. Interestingly, two electrocatalytic reduction peaks are observed at −0.24 and −0.56 V (vs SCE), respectively, one controlled by surface wave and the other controlled by diffusion process. The Chi–HeNTs/Au electrode shows a linear response to H2O2 concentration ranging from 1 × 10−6 to 1.6 × 10−5 mol L−1 with a detection limit of 5 × 10−8 mol L−1 and a sensitivity as high as 1859 μA μM−1 cm−2.  相似文献   

12.
《Comptes Rendus Chimie》2015,18(4):438-448
A highly sensitive method was investigated for the simultaneous determination of acetaminophen (AC), dopamine (DA), and ascorbic acid (AA) using a PbS nanoparticles Schiff base-modified carbon paste electrode (PSNSB/CPE). Differential pulse voltammetry peak currents of AC, DA and AA increased linearly with their concentrations within the ranges of 3.30 × 10−8–1.58 × 10−4 M, 5.0 × 10−8–1.2 × 10−4 M and 2.50 × 10−6–1.05 × 10−3 M, respectively, and the detection limits for AC, DA and AA were 5.36 × 10−9, 2.45 × 10−9 and 1.86 × 10−8 M, respectively. The peak potentials recorded in a phosphate buffer solution (PBS) of pH 4.6 were 0.672, 0.390, and 0.168 V (vs Ag/AgCl) for AC, DA and AA, respectively. The modified electrode was used for the determination of AC, DA, and AA simultaneously in real and synthetic samples.  相似文献   

13.
《中国化学快报》2020,31(10):2752-2756
Electrochemical analysis is a promising technique for detecting biotoxic and non-biodegradable heavy metals. This article proposes a novel composite electrode based on a polyaniline (PANi) framework doped with bismuth nanoparticle@graphene oxide multi-walled carbon nanotubes (Bi NPs@GO-MWCNTs) for the simultaneous detection of multiple heavy metal ions. Composite electrodes are prepared on screen-printed electrodes (SPCEs) using an efficient dispensing technique. We used a SM200SX-3A dispenser to load a laboratory-specific ink with optimized viscosity and adhesion to draw a pattern on the work area. The SPCE was used as substrate to facilitate cost-effective and more convenient real-time detection technology. Electrochemical techniques, such as cyclic voltammetry and differential pulse voltammetry, were used to demonstrate the sensing capabilities of the proposed sensor. The sensitivity, limit of detection, and linear range of the PANi-Bi NPs@GO-MWCNT electrode are 2.57 × 102 μA L μmol−1 cm−2, 0.01 nmol/L, and 0.01 nmol/L–5 mmol/L and 0.15 × 10−1 μA L μmol−1 cm−2, 0.5 nmol/L, and 0.5 nmol/L–5 mmol/L for mercury ion (Hg(II)) and copper ion (Cu(II)) detection, respectively. In addition, the electrode exhibits a good selectivity and repeatability for Hg(II) and Cu(II) sensing when tested in a complex heavy metal ion solution. The constructed electrode system exhibits a detection performance superior to similar methods and also increases the types of heavy metal ions that can be detected. Therefore, the proposed device can be used as an efficient sensor for the detection of multiple heavy metal ions in complex environments.  相似文献   

14.
A novel double chained amphiphile,N-(α-4-hexylphenoxy)-lauroyltaurate(abbreviated as 10 6B-T),has been synthesized. The structures of main intermediate products and the title product were characterized by ~1H NMR.The new amphiphile shows high surface activity.The critical micelle concentration(cmc),which is 1.1×10~(-5)mol/L,is much lower than that of conventional double chained surfactants,such as sodium bis(2-ethylhexyl)sulfosuccinate(AOT).  相似文献   

15.
New biocomposite materials, based on the incorporation of DNA doped p-aminobenzensulfonic acid, was fabricated by electrochemical method. A carbon fiber microelectrode modified by this thin film was fabricated for selective determination of uric acid (UA) in the presence of a larger amount of ascorbic acid (AA). It was found that the voltammetric oxidation peak separation between UA and AA is about 260 mV at the modified electrode. A linear response of the peak current versus the concentration was found in the range of 8 × 10−7–6 × 10−4 M with correlation coefficient of 0.9991 and the detection limit was 5 × 10−7 M (s/n = 3) at the 5 × 10−4 M AA. The presence of high concentration AA did not interference the determination. The electropolymerized film was characterized by SEM techniques. The modified electrode shows good sensitivity, selectivity and stability.  相似文献   

16.
Carbon nanofibers embedded with ultrafine zirconia nanoparticles (ZrO2-CNFs) are fabricated via a new methodology. Polyvinylpyrrolidone (PVP) and polymethylmethacrylate (PMMA) binary polymers containing zirconium n-butoxide are first dissolved in dimethylformamide, and the resulting solution is electrospun and heat-treated. The tetragonal zirconia nanoparticles formed, with a size of 5 ± 2 nm in diameter, are uniformly distributed in the carbon nanofibres. Using Nafion as an additive, ZrO2-CNFs are drop-cast onto the glassy carbon electrode (ZrO2-CNF/GCE) and the modified electrode is then applied to detect methyl parathion (MP) using differential pulse voltammetry. Two linear relationships are found at the concentration ranges of 1 × 10 9–2 × 10 8 g/L and 2 × 10 8–2 × 10 7 g/L, with a detection limit of 3.4 × 10 10 g/L (S/N > 3). The electrospun-based ZrO2-CNF is a very promising coating material for electrochemical sensing of organophosphorus compounds.  相似文献   

17.
In this article, a new kind of hairpin DNA Electrochemical biosensor using nitroacridone as electrochemical indicator was first designed, and used to detect BCR/ABL fusion gene in Chronic Myelogenous Leukemia (CML). The results indicated that in pH 7.0 Tris–HCl buffer solution, the oxidation peak current was linear with the concentration of complementary strand in the range of 6.2 × 10−8–3.1 × 10−7 mol/l with a detection limit of 5.3 × 10−9 mol/l. This new hairpin DNA electrochemical biosensor demonstrates its excellent specificity for single-base mismatch and complementary (dsDNA) after hybridization, and this probe has been used for assay of PCR product of a real sample with satisfactory result.  相似文献   

18.
The determination of cysteine by means of square wave cathodic stripping voltammetry (SWCSV) is reported here for the first time at Bi-modified carbon paste electrodes (CPEs). The modified electrodes are 17% w/w metallic Bi powder mixed with CP (Bi-CPEs) and the technique is based on the enhancement of Bi surface oxidation in the presence of cysteine at a carefully chosen accumulation potential and the subsequent reduction-stripping of the product (proposed to be bismuth(III) cysteinate) by potential scanning to more negative values. The wide concentration range of 1 × 10−6–5 × 10−5 M for cysteine can be assessed by SWCSV using Bi-CPEs and, by appropriate choice of accumulation times, two linear response concentration regimes could be identified: 1 × 10−6–1 × 10−5 M (accumulation for 600 s) and 1 × 10−5–5 × 10−5 M (accumulation for 100 s), with estimated detection limits of 3 × 10−7 and 2 × 10−6 M, respectively.  相似文献   

19.
Three new hybrid organic/inorganic polymeric ligand-exchange chiral stationary phases were developed by radical chain transfer reaction and surface grafting on silica gel,and successfully used for the enantioseparations of DL-amino acids and DL-hydroxyl acids.The resolutions were achieved by using water containing 2.0×10~(-4) mol/L of CuAc_2 as a mobile phase,column temperature of 40℃,flow rate of 1.0mL/min and detection at UV 254 nm.The elution order of D-isomer before L-isomer was observed for all DL-amino acids resolved except DL-Pro.  相似文献   

20.
The electrochemiluminescent (ECL) behavior of lucigenin on a multiwall carbon nanotubes modified glassy carbon electrode (MWNT/GCE) during anodic scanning was studied. A strong and stable anodic ECL signal was found on MWNT modified electrode, which results from the oxidation reaction between lucigenin and the oxidation production of OH-. The effects of electrode materials, pH and scan rate on the ECL intensity were studied, and the possible ECL mechanism was also proposed. Under the optimized conditions, the ECL intensity was found to be linear with concentration of lucigenin in the range of 5.0 × 10?7–5.0 × 10?6 mol/L with a detection limit of 2.0 × 10?7 mol/L. Superoxide dimutase (SOD) was found to be able to inhibit this ECL system, based on which a sensitive ECL methods for detection of SOD had been established.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号