1.
Kang SH  Park M  Cho K 《Electrophoresis》2005,26(16):3179-3184
We evaluated a novel strategy for fast diagnosis by microchip electrophoresis (ME), using programmed field strength gradients (PFSG) in a conventional glass double-T microfluidic chip. The ME-PFSG allows for the ultrafast separation and enhanced resolving power for target DNA fragments. These results are based on electric field strength gradients (FSG) that use an ME separation step in a sieving gel matrix poly-(ethylene oxide). The gradient can develop staircase or programmed shapes FSG over the time. The PFSG method could be easily used to increase separation efficiency and resolution in ME separation of specific size DNA fragments. Compared to ME that uses a conventional and constantly applied electric field (isoelectrostatic) method, the ME-PFSG achieved about 15-fold faster analysis time during the separation of 100 bp DNA ladder. The ME-PFSG was also applied to the fast analysis of the PCR products, 591 and 1191 bp DNA fragments from the 18S rRNA of Babesia gibsoni and Babesia caballi.  相似文献   

2.
A high-resolution separation of DNA bands is achieved by electrophoresis with a long gel in DNA base sequencing using fluorescence detection. We separate 760 and 761 base DNA fragments using the 93 cm migration electrophoresis optimized for the separation of DNA bands. A T7 DNA polymerase and an Mn++ buffer are used in sequencing reactions to obtain fluorescence peaks of uniform strength, and the peak areas in the spectrum are used for recognizing the peak number in a cluster of successive peaks. This method is successfully applied to the DNA fragment spectrum obtained by 93 cm migration electrophoresis, which results in a single-band differentiation of bands of 1040 base DNA.  相似文献   

3.
Chen Z  Burns MA 《Electrophoresis》2005,26(24):4718-4728
An adequate buffer reservoir is one essential component of an electrophoresis system, providing current carrying ions and maintaining constant pH. In a microfabricated DNA separation system with on-chip electrodes, the amount of buffer used is limited by the design of the device; the buffer continuity can be easily disturbed by the production of bubbles. Continuously flowing 1 x Tris-borate-EDTA (TBE) buffer over the electrodes at the cathodic end solves both problems. This flow increases the resolution for ssDNA primer separations (21 and 25 bases) to a maximum value of 1.4 within a distance of 1.2 cm, about four times higher than that without flow. Similar improvement has been achieved for dsDNA separation (20 bp ladder; BioRad) at a distance of only 0.4 cm, giving baseline resolution for bands from 20 to 240 bp. We have also investigated the effect of buffer concentration on resolution, and no similar improvement can be obtained by merely increasing the buffer concentration without flow.  相似文献   

4.
We have examined the effects of pulsed electric fields on the separation of single-stranded DNA molecules in polyacrylamide sequencing gels. Using different electric field pulsing regimens, the mobilities of single-stranded DNA molecules can be retarded or increased as compared to conventional electrophoresis. These results indicated that pulsed field techniques can be applied to gel electrophoresis of small single-stranded DNA molecules.  相似文献   

5.
The term pulsed-field gel electrophoresis (PFGE) is used as an acronym to indicate any technique that resolves (large) DNA molecules by continuous reorientation. It bridges the resolution gap between cytogenetic methods (>5 Mb) and DNA analysis (<50 kb). Initially, PFGE was used to study the chromosomal content of unicellular eukaryotic organisms of interest to genetic research and population health. Later, PFGE was used to construct megabase maps of segments of the human genome. Successfull utilization of PFGE requires the availability of very high-molecular weight DNA. This article describes the modification of standard DNA protocols necessary to handle large DNA molecules, based on its encapsidation in agarose.  相似文献   

6.
The use of pulsed fields in manual sequencing opens up the compression zone found with a DC field and extends the range of resolution from a few hundred bases to several thousand bases. The band inversion problem is overcome with the proper pulsing conditions, and the bands are sharper than for the DC field case. Accurate visual reading is possible up to about 800-900 bases. The method is compatible with automation techniques, since the band spectrum is stretched continuously during migration, and the smaller fragments are run off the gel.  相似文献   

7.
DNA fragments up to 9 kb in size were stacked and separated by polyacrylamide gel electrophoresis, and those up to 50 kb in size by agarose gel electrophoresis, using a discontinuous buffer system. Polyacrylamide gels at pH 8.9, 2 degrees C, 0.01 M ionic strength, yielded sharp bands with DNA loads of 8 micrograms/cm2 of gel of a mixture of 19 DNA fragments in the size range of 72-23130 bp, while agarose gels at pH 8.5, 25 degrees C, provided well-resolved, unperturbed bands at 0.04 M ionic strength with DNA loads of 1 microgram/cm2 of the same mixture. Note that the ionic strength of the agarose gels is comparable to the conventionally used 0.5 x TBE (Tris-borate-EDTA) buffer, while that successfully applied to polyacrylamide is seven-fold less than the ionic strength of conventionally used 1 x TBE buffer, with a substantially shorter duration of electrophoresis as a result. The application of a discontinuous buffer system to the gel electrophoresis of DNA results in (i) Band identification by Rf, the migration distance relative to a sharply defined "buffer front" (moving boundary). This is sufficiently labor saving, compared to determining absolute mobilities, so as to render practical the expression of bands as numbers, with benefits for data storage, statistical manipulations and physico-chemical exploitation of mobility data. The use of Rf's also circumvents loss of precision in mobility measurement resulting from progressive band spreading of dye bands used as a front. (ii) A uniformly and highly concentrated starting zone, beneficial to resolution, is obtained, without the losses by which separate concentration steps are usually burdened.(ABSTRACT TRUNCATED AT 250 WORDS)  相似文献   

8.
Slab gel electrophoresis is the most widely used separation method for DNA fragments, proteins and carbohydrates, and miniaturization of this process is expected to provide fast, inexpensive and convenient analyses. However, two problems concerning the miniaturization of gel electrophoresis have to be solved:the separation performance and spatial resolution of the detector. We demonstrated that the separation performance was improved by using a discontinuous gel in which a concentrating gel was used to stack the sample to a sharp band, and using thermal lens microscope (TLM), which is highly sensitive and has a spatial resolution of micron level even in light scattering matrices as a gel, such sharpened separated bands were successfully detected. In this paper, we developed a miniaturized slab gel electrophoresis apparatus, demonstrated high speed separation of DNA fragments, and applied it to genetic diagnosis of coronary heart disease.  相似文献   

9.
Self-assembling of metallic nanoparticles to form well-defined nanostructured structures is a field that has been receiving considerable research interest in recent years. In this field, DNA is a commonly used linker molecule to direct the assembly of the nanoscale building blocks because of its unique recognition capabilities, mechanical rigidity, and physicochemical stability. This study reported our novel approach to generate gold nanoparticle-DNA conjugates bearing specially designed DNA linker molecules that can be used as building blocks to construct nanoassemblies with precisely controlled structure or as nanoprobes for quantitative DNA sequence detection analysis. In our approach, gold nanoparticle-DNA conjugates bearing a specific number of long double-stranded DNA strands were prepared by gel electrophoresis. A restriction endonuclease enzyme was then used to manipulate the length of the nanoparticle-bound DNA. This enzymatic cleavage was confirmed by gel electrophoresis, and digestion efficiency of 90% or more was achieved. With this approach, nanoparticle conjugates bearing a specific number of strands of short DNA with less than 20-base can be achieved.  相似文献   

10.
The maximum length of DNA molecules that can be separated by gel electrophoresis can be increased greatly by periodically altering the direction of the electric field with respect to the gel by an angle that exceeds 90 degrees. One method involves rotating the gel by the desired angle in alternate directions periodically during electrophoresis. We describe a modification of the rotating gel electrophoresis apparatus developed by Serwer (Electrophoresis 1987, 8, 301-304) that uses a pneumatic rotary actuator instead of a stepping motor, hence reducing the cost by about 50%. Other advantages of our design are a lower center of gravity that makes the apparatus more stable and the removal of all electrical power from beneath the fluid-filled electrophoresis chamber. We present data demonstrating the separation of chromosomal length DNA molecules from Saccharomyces cerevisiae strain 334 into 14 resolved bands in parallel lanes.  相似文献   

11.
Dong Y  McGown LB 《Electrophoresis》2011,32(10):1209-1216
Sieving gels are used in capillary gel electrophoresis to resolve DNA strands of different lengths. For complex samples, however, such as those encountered in metagenomic analysis of microbial communities or biofilms, length-based separation may mask the true genetic diversity of the community since different organisms may contribute same-length DNA with different sequences. There is a need, therefore, for DNA separations based on both the length and sequence. Previous work has demonstrated the ability of guanosine gels (G-gels) to separate four single-stranded DNA 76-mers that differ by only a few A/G base substitutions. The goal of the present work is to determine whether G-gels could be combined with commercial sieving gels in order to simultaneously separate DNA based on both length and sequence. The results are given for the four 76-mers and for a standard dsDNA ladder. Commercial sieving gels were used alone and in combination with G-gels. For the 76-mers, the combined medium was less efficient than the G-gel alone but was able to achieve partial resolution. The combined medium was at least as effective as the sieving gel alone at resolving the denatured DNA ladder and showed indications of sequence-based resolution as well, as supported by MALDI-MS. The results show that the combined sieving gel/G-gel medium retains the selectivity of the individual media, providing a promising approach to simultaneous length- and sequence-based DNA separation for metagenomic analysis of complex systems.  相似文献   

12.
Plasmid DNA isoforms can be separated by both agarose gel electrophoresis and a variety of chromatographic methods, but both of these approaches have significant shortcomings in terms of scalability, throughput, and/or resolution. This study provides the first demonstration that the supercoiled, linear, and open-circular isoforms of plasmid DNA can be effectively separated based on differences in their elongational flexibility in the highly converging flow field that is established during membrane ultrafiltration. Data were obtained with plasmids from 3 to 17 kbp in size using commercially available cellulose ultrafiltration membranes with pores an order of magnitude smaller than the DNA root-mean-square radius of gyration. High-resolution separations were achieved by controlling the filtrate flux between the critical flux values required for transmission of the individual isoforms. The separation behavior in ultrafiltration was very different than that observed in size exclusion chromatography or agarose gel electrophoresis due to differences in the underlying separation mechanisms. The simplicity of the ultrafiltration process makes this approach attractive for a wide range of applications, including large-scale purification of plasmid DNA for gene therapy.  相似文献   

13.
A new method of signal analysis for automated fluorescence-based DNA sequencing is presented. Signal resolution is a limiting factor in obtaining accurate sequence information beyond 400-450 nucleotides per gel lane. We have developed a computer program for the imaging of DNA bands in sequencing gels. The image analysis shows that distortions in the shapes of the bands decrease resolution of peaks observed served in the standard data plots. Reconstruction of the undistorted band shape prior to signal analysis substantially improves the resolution of peaks and may improve the accuracy and length of the contiguous sequence read. Image analysis identified other factors limiting the accuracy and length of automated DNA sequence analysis and provided a tool for evaluating various remedies. Our techniques should also be applicable in other systems, for example, in gel electrophoresis of proteins and DNA restriction fragments, and in scranning densitometry.  相似文献   

14.
To facilitate a direct interface between protein separation by PAGE and protein identification by mass spectrometry, we developed a multichannel system that continuously collects fractions as protein bands migrate off the bottom of gel electrophoresis columns. The device was constructed using several short linear gel columns, each of a different percent acrylamide, to achieve a separation power similar to that of a long gradient gel. A “Counter Free‐Flow” elution technique then allows continuous and simultaneous fraction collection from multiple channels at low cost. We demonstrate that rapid, high‐resolution separation of a complex protein mixture can be achieved on this system using SDS‐PAGE. In a 2.5 h electrophoresis run, for example, each sample was separated and eluted into 48–96 fractions over a mass range of ~10–150 kDa; sample recovery rates were 50% or higher; each channel was loaded with up to 0.3 mg of protein in 0.4 mL; and a purified band was eluted in two to three fractions (200 μL/fraction). Similar results were obtained when running native gel electrophoresis, but protein aggregation limited the loading capacity to about 50 μg per channel and reduced resolution.  相似文献   

15.
It was theoretically predicted earlier that if a periodic force without constant component is applied to a particle, then the particle can produce a directed drift in some direction. The effect is named nonlinear electrofrictiophoresis, because it is crucial for its appearance that the friction force depends on the particle's velocity in a nonlinear manner. We test a possibility to observe this effect when a mixture of fragments of DNA (the DNA ladder) moves in the agarose gel. For this purpose, we study the nonlinear characteristics of a DNA ladder movement in the gel. The gels with the ladder were run under various electric field strengths. It was found that the friction coefficient for each DNA fragment in the ladder depends on the migration velocity, suggesting that energy dissipation during migration is a nonlinear function of velocity. This nonlinearity makes the system under consideration suitable for observing nonlinear electrofrictiophoresis. A possible velocity of directed drift under periodic electric drive without constant component was estimated numerically for experimentally observed dependencies. The velocity appeared to be comparable with that of migration under a constant field of moderate strength. A possible mechanism of energy dissipation during movement of DNA through the gel is discussed.  相似文献   

16.
《Analytical letters》2012,45(7):1255-1264
Abstract

Agarose immobilized DNA samples suitable for pulsed field gel electrophoresis (PFGE) were prepared by lysis of immobilized cells followed by disruption of DNA-protein complexes with denaturant and detergent solutions. The electrophoretic pattern of samples deproteinized by this method were identical to samples treated with the fungal protease Proteinase K.  相似文献   

17.
We present 50 cm long microchannels in a monolithic device for high resolution, long read-length DNA sequencing. These devices were fabricated and bonded in borofloat glass using unconventional photolithography techniques with 48-188 independent, straight microchannels. The microchannel DNA separation was tested with POP-6 polymer and a DNA sequencing ladder separated at room temperature and 200 V/cm. Single-base resolution greater than 600 bases was achieved and the sequence base called to 640 bases with 98% accuracy. Under the same experimental conditions, the performance of the microchip was identical to a fused-silica capillary with similar cross-sectional area.  相似文献   

18.
The factors affecting the electrophoretic separation of DNA bands in DNA base sequencing using fluorescence detection are analyzed. All the factors contributing to DNA band spacing and band width are evaluated; DNA diffusion and thermal effects on gels are the main considerations. The dependence of the gel's electrical resistivity on gel temperature and the variation of temperature over gel thickness are associated with a broadening of DNA band width. As a result of the analyses the maximum separable base number is represented as a function of various electrophoretic variables. The best separations are possible with an electric field strength corresponding to gel thickness. The maximum separable base number increases as the gel thickness decreases. It also increases as the migration distance increases, but it becomes saturated and has an upper limit when the migration distance is long. This upper limit increases as gel thickness decreases. DNA fragments with 600 and 601 bases can be completely separated from each other under optimum conditions for a 0.2 mm thick gel plate. Furthermore, using the band spacing information, under the same conditions, 750 bases could be assigned separately.  相似文献   

19.
Base-calling precision of short tandem repeat (STR) allelic bands on dynamic slab-gel electrophoresis systems was evaluated. Data was collected from over 6000 population database allele peaks generated from 468 population database samples amplified with the AmpF/STR Profiler Plus (PP) kit and electrophoresed on ABD 377 DNA sequencers. Precision was measured by way of standard deviations and was shown to be essentially the same, whether using fixed or floating bin genotyping. However, the allelic ladders have proven more sensitive to electrophoretic variations than database samples, which have caused some floating bins of D18S51 to shift on occasion. This observation prompted the investigation of polyacrylamide gel formulations in order to stabilize allelic ladder migration. The results demonstrate that, although alleles comprised in allelic ladders and questioned samples run on the same gel should migrate in an identical manner, this premise needs to be verified for any given electrophoresis platform and gel formulation. We show that the compilation of base-calling data is a very informative and useful tool for assessing the performance stability of dynamic gel electrophoresis systems, stability on which depends genotyping result quality.  相似文献   

20.
Microchip electrophoresis has become a powerful tool for DNA separation, offering all of the advantages typically associated with miniaturized techniques: high speed, high resolution, ease of automation, and great versatility for both routine and research applications. Various substrate materials have been used to produce microchips for DNA separations, including conventional (glass, silicon, and quartz) and alternative (polymers) platforms. In this study, we perform DNA separation in a simple and low-cost polyester-toner (PeT)-based electrophoresis microchip. PeT devices were fabricated by a direct-printing process using a 600 dpi-resolution laser printer. DNA separations were performed on PeT chip with channels filled with polymer solutions (0.5% m/v hydroxyethylcellulose or hydroxypropylcellulose) at electric fields ranging from 100 to 300 V cm(-1). Separation of DNA fragments between 100 and 1000 bp, with good correlation of the size of DNA fragments and mobility, was achieved in this system. Although the mobility increased with increasing electric field, separations showed the same profile regardless of the electric field. The system provided good separation efficiency (215,000 plates per m for the 500 bp fragment) and the separation was completed in 4 min for 1000 bp fragment ladder. The cost of a given chip is approximately $0.15 and it takes less than 10 minutes to prepare a single device.  相似文献   