首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A new electrochemical sensor for melamine with 3,4-dihydroxyphenylacetic acid as the recognition element is established. The results of Fourier Transform Infrared (FT-IR) spectra demonstrate that melamine may interact with 3,4-dihydroxyphenylacetic acid to form a complex mainly through the hydrogen-bonding interaction. The electrochemical behavior of 3,4-dihydroxyphenylacetic acid in the presence of melamine was studied. The anodic peak currents of 3,4-dihydroxyphenylacetic acid obtained by differential pulse voltammetry are linear with the logarithm of melamine concentrations in the range from 1.0 × 10−8 to 5.0 × 10−6 M with a linear coefficiency of 0.997. The detection limit is 3.0 × 10−9 M. The proposed method displayed an excellent sensitivity and was successfully applied to the determination of melamine in milk products.  相似文献   

2.
Chen S  Du D  Huang J  Zhang A  Tu H  Zhang A 《Talanta》2011,84(2):451-456
An electrochemical strategy on the basis of rationally designed molecularly imprinted sol-gel polymer embedded with gold nanoparticles (AuNPs) is developed for the specific and sensitive determination of Sudan I. The rationally designed sensing Sudan I imprinted sol-gel was prepared by mixing Sudan I with 3-aminopropyltriethoxysilane, tetraethoxysilane, chitosan, and AuNPs, followed by copolymerization and extraction of the template molecules. The hybrid forming membrane was characterized by SEM and FTIR-ATR, and used for the linear sweep voltammetric (LSV) determination of Sudan I in water/ethanol solutions. The LSV responses exhibited high sensitivity and selectivity, as discriminated from Sudan I analogues. Under optimal experimental conditions, LSV peak currents were linearly proportional to the concentrations of Sudan I in the range from 0.1 × 10−7 to 1.0 × 10−5 M, with a detection limit of 2.0 × 10−9 M. The strategy is generally applicable in developing sensitive, selective, and moreover, reusable electrochemical sensors for quantitative determination of electroactive species.  相似文献   

3.
Monolayers of 3,3′-dithiodipropionic acid (DTDPA) were prepared on a polycrystalline gold electrode through a self-assembly procedure to produce a gold 3,3′-dithiodipropionic acid self-assembled monolayer (AuDTDPA) modified electrode. The characterization of the AuDTDPA electrode was investigated by cyclic voltammetry and ac impedance using the [Fe(CN)6]3−/4− redox couple. The electrochemical behavior of DA on the modified electrode AuDTDPA was studied by cyclic and square-wave voltammetries, using phosphate buffer as supporting electrolyte. The oxidation peak current for DA increases linearly with concentration in the range of 0.35 × 10−5 to 3.4 × 10−5 mol L−1. The performance of the AuDTDPA modified electrode was evaluated for the electroanalytical determination of dopamine (DA) in a pharmaceutical formulation. The AuDTDPA modified electrode showed a stable behavior and the presence of surface-COOH groups avoided the passivation of the electrode surface during the dopamine oxidation.  相似文献   

4.
Electrochemical behavior of cerium hexacyanoferrate (CeHCF) incorporated on multi-walled carbon nanotubes (MWNTs) modified GC electrode is investigated by scanning electron microscopy (SEM) and electrochemical techniques. The CeHCF/MWNT/GC electrode showed potent electrocatalytic activity toward the electrochemical oxidation of tryptophan in phosphate buffer solution (pH 7.0) with a diminution of the overpotential of 240 mV. The anodic peak currents increased linearly with the concentration of tryptophan in the range of 2.0 × 10−7 to 1.0 × 10−4 M with a detection limit of 2.0 × 10−8 M (at a S/N = 3). And the determination of tryptophan in pharmaceutical samples was satisfactory.  相似文献   

5.
A new palladium nanoparticle functionalized multi-wall carbon nanotubes (nano-Pd/CNTs) modified pyrolytic graphite electrode (PGE) has been fabricated for electrochemical sensing of calcium dobesilate (CD) in pharmaceutical capsules. The nano-Pd/CNTs were characterized by transmission electron microscopy (TEM) and X-ray diffraction (XRD). The nano-Pd/CNTs composite showed a strong electrocatalytic property for CD. The anodic peak current is 6-fold than that obtained in bare PGE and the oxidation potential has an obvious shift to negative. The anodic peak current is proportional to the concentration of CD in the range of 1.0 × 10−7 to 7.0 × 10−4 mol L−1, with a linear relative coefficient r = 0.999 and a detection limit 4.0 × 10−8 mol L−1 (S/N = 3). This kind of electrode shows good stability, sensitivity, reproducibility, large linear range and low detection limit towards electrochemical determination of CD. The proposed method provides a selective and sensitive electrochemical sensor of calcium dobesilate.  相似文献   

6.
Carbon nanoparticles (CNPs) and halloysite nanoclay (HNC) modified carbon paste electrode (HNC–CNP–CPE) was developed for the determination of methyl parathion (MP) and ethyl parathion (EP). The electrochemical behavior of these molecules was investigated employing cyclic voltammetry (CV), chronocoulometry (CC), electrochemical impedance spectroscopy (EIS) and potentiometric stripping analysis (PSA). After optimization of analytical conditions employing this electrode at pH 5.0 in acetate buffer (0.1 M), the peak currents were found to vary linearly with its concentration in the range of 1.55 × 10−9 to 3.67 × 10−6 M and 1.21 × 10−9 to 4.92 × 10−6 M for MP and EP, respectively. The detection limits (S/N = 3) of 4.70 × 10−10 M and 3.67 × 10−10 M were obtained for MP and EP, respectively, using PSA. The prepared modified electrode showed several advantages such as simple preparation method, high sensitivity, very low detection limits and excellent reproducibility. The proposed method was employed for the determination of MP and EP in fruits, vegetables, water and soil samples.  相似文献   

7.
An ultrasensitive and simple method for the determination of melamine was developed based on the fluorescence quenching of thioglycolic acid (TGA) capped CdTe quantum dots (QDs) at pH 11.0. In strong alkaline aqueous solution, the selectivity of the method has been greatly improved due to most heavy metal ions show no interference as they are in the precipitation form or in their anion form. Furthermore, CdTe quantum dots have higher quantum yields at higher pH. The method has a wider concentration range and lower detection limit. The influence factors on the determination of melamine were investigated and the optimum conditions were determined. Under optimum conditions, the fluorescence intensity change of TGA coated CdTe quantum dots was linearly proportional to melamine over a concentration range from 1.0 × 10−11 to 1.0 × 10−5 mol L−1 with a correlation coefficient of 0.9943 and a detection limit of 5 × 10−12 mol L−1. The mechanism of fluorescence quenching of the QDs has been proposed based on the infrared spectroscopy information and electrophoresis experiments in presence of melamine under alkaline condition. The proposed method was employed to detect trace melamine in milk powder and pet feeds with satisfactory results.  相似文献   

8.
Li J  Lin XQ 《Analytica chimica acta》2007,596(2):222-230
A novel biosensor was fabricated by electrochemical deposition of gold nanoclusters on ultrathin overoxidized polypyrrole (PPyox) film, formed a nano-Au/PPyox composite on glassy carbon electrode (nano-Au/PPyox/GCE). The properties of the nanocomposite have been characterized by field emission scanning electron microscope (FE-SEM), X-ray photoelectron spectroscopy (XPS), powder X-ray diffraction (XRD) and electrochemical investigations. The nano-Au/PPyox/GCE had strongly catalytic activity toward the oxidation of epinephrine (EP), uric acid (UA) and ascorbic acid (AA), and resolved the overlapping voltammetric response of EP, UA and AA into three well-defined peaks with a large anodic peak difference. The catalytic peak currents obtained from differential pulse voltammetry increased linearly with increasing EP and UA concentrations in the range of 3.0 × 10−7 to 2.1 × 10−5 M and 5.0 × 10−8 to 2.8 × 10−5 M with a detection limit of 3.0 × 10−8 and 1.2 × 10−8 M (s/n = 3), respectively. The results showed that the modified electrode can selectively determine EP and UA in the coexistence of a large amount of AA. In addition, the sensor exhibited excellent sensitivity, selectivity and stability. The nano-Au/PPyox/GCE has been applied to determination of EP in epinephrine hydrochloride injection and UA in urine samples with satisfactory results.  相似文献   

9.
Multi-walled carbon nanotube decorated with silver nanoparticles (AgNPs-MWCNT) is used as an effective strategy for modification of the surface of pyrolytic graphite electrode (PGE). This modification procedure improved colloidal dispersion of the decorated MWCNTs in water, affording uniform and stable thin films for altering the surface properties of the working electrode. Robust electrode for sensing applications is obtained in a simple solvent evaporation process. The electrochemical behavior of sumatriptan (Sum) at the bare PGE and AgNPs-MWCNT modified PGE is investigated. The results indicate that the AgNPs-MWCNT modified PGE significantly enhanced the oxidation peak current of Sum. A remarkable enhancement in microscopic area of the electrode together with strong adsorption of Sum on the surface of the modified electrode resulted in a considerable increase in the peak current of Sum. Experimental parameters, such as scan rate, pH, accumulation conditions and amount of the modifier used on the PGE surface are optimized by monitoring the CV responses toward Sum. It is found that a maximum current response can be obtained at pH 7.4 after accumulation at open circuit for 150 s. Further experiments demonstrated that the oxidative peak currents increased linearly with Sum concentration in the range of 8.0 × 10−8-1.0 × 10−4 mol L−1 with a detection limit of 4.0 × 10−8 mol L−1. The modified electrode showed high sensitivity, selectivity, long-term stability and remarkable voltammetric reproducibility in response to Sum. These excellent properties make the prepared sensor suitable for the analysis in pharmaceutical and clinical preparations. The modified electrode was successfully applied for the accurate determination of trace amounts of Sum in pharmaceutical preparations.  相似文献   

10.
We proposed a green and facile approach for the synthesis of β-cyclodextrin-coated poly(diallyldimethylammonium chloride)-functionalized graphene composite film (β-CD-PDDA-Gr) by using l-ascorbic acid (l-AA) as the reducing agent at room temperature. The β-CD-PDDA-Gr composite film modified glassy carbon-rotating disk electrode (GC-RDE) was then developed for the sensitive simultaneous determination of two synthetic food colorants: sunset yellow (SY) and tartrazine (TT). By cyclic voltammetry (CV), the peak currents of SY and TT increased obviously on the developed electrochemical sensor. The kinetic parameters, such as diffusion coefficient D and standard heterogeneous rate constant kb, were estimated by linear sweep voltammetry (LSV). Under the optimal conditions, the differential pulse voltammetry (DPV) signals of SY and TT on the β-CD-PDDA-Gr modified GC-RDE were significantly enhanced. The enhanced anodic peak currents represented the excellent analytical performance of simultaneous detection of SY and TT in the range of 5.0 × 10−8 to 2.0 × 10−5 mol L−1, with a low limit of detection (LOD) of 1.25 × 10−8 mol L−1 for SY and 1.43 × 10−8 mol L−1 for TT (S N−1 = 3). This proposed method displayed outstanding selectivity, good stability and acceptable repeatability and reproducibility, and also has been used to simultaneously determine SY and TT in some commercial soft drinks with satisfactory results. The obtained results were compared to HPLC of analysis for those two colorants and no significant differences were found. By the treatment of the experimental data, the electrochemical reaction mechanisms of SY and TT both involved a one-electron-one-proton-transfer process.  相似文献   

11.
A multi-wall carbon nanotubes (MWNTs)-dihexadecyl hydrogen phosphate (DHP) film-coated glassy carbon electrode (GCE) was fabricated, and the electrochemical behaviors of acyclovir on the MWNTs-DHP film-coated GCE were investigated by using cyclic voltammetry (CV), linear sweep voltammetry (LSV), electrochemical impedance spectroscopy (EIS) and chronocoulometry (CC). The oxidation peak current of acyclovir increased significantly and the peak potential shifted negatively at the MWNTs-DHP film-modified GCE, compared with that at a bare GCE. The results showed that this nano-structured film electrode exhibited excellent enhancement effects on the electrochemical oxidation of acyclovir. Consequently, a simple and sensitive electroanalytical method was developed for the determination of acyclovir. The oxidation peak current was proportional to the concentration of acyclovir from 8.0 × 10−8 to 1.0 × 10−5 mol/L. The detection limit was about 3.0 × 10−8 mol/L for 60 s accumulation at 0.00 V. The proposed method was demonstrated by using acyclovir tablets and the result was satisfying.  相似文献   

12.
A simple, rapid and highly selective method for the determination of the most abundant α-dicarbonyl compound in wine and beer has been developed for the first time by employing square wave voltammetry. A novel electrochemical sensor, based on the electrodeposition of platinum nanoparticles onto single wall carbon nanotubes that were cast on a glassy carbon electrode (GCE) substrate, is presented in this paper. This modified electrode exhibited excellent catalytic activity in the electroreduction of methylglyoxal, showing much higher peak currents than those measured on an unmodified GCE. The effects of different experimental and instrumental parameters, such as solution pH and square wave frequency, were examined. The reduction peak current showed a linear range of from 0.1 × 10−6 to 100 × 10−6 M with a 0.9979 correlation coefficient; and a low detection limit of 2.8 × 10−9 M was also obtained. The proposed methodology was successfully applied to the quantitative analysis of methylglyoxal in wine and beer samples. The developed sensor possesses advantageous properties such as a high active surface area, stability, and rapid electron transfer rate, which cumulatively demonstrate high performance toward the electrocatalytic reduction and detection of methylglyoxal.  相似文献   

13.
A novel Cu-zeolite A/graphene modified glassy carbon electrode for the simultaneous electrochemical determination of dopamine (DA) and ascorbic acid (AA) has been described. The Cu-zeolite A/graphene composites were prepared using Cu2+ functionalized zeolite A and graphene oxide as the precursor, and subsequently reduced by chemical agents. The composites were characterized by X-ray diffraction, Fourier transform infrared spectra and scanning electron microscopy. Based on the Cu-zeolite A/graphene-modified electrode, the potential difference between the oxidation peaks of DA and AA was over 200 mV, which was adequate for the simultaneous electrochemical determination of DA and AA. Also the proposed Cu-zeolite/graphene-modified electrode showed higher electrocatalytic performance than zeolite/graphene electrode or graphene-modified electrode. The electrocatalytic oxidation currents of DA and AA were linearly related to the corresponding concentration in the range of 1.0 × 10−7–1.9 × 10−5 M for DA and 2.0 × 10−5–2.0 × 10−4 M for AA. Detection limits (<!-- no-mfc -->S/N<!-- /no-mfc --> = 3) were estimated to be 4.1 × 10−8 M for DA and 1.1 × 10−5 M for AA, respectively.  相似文献   

14.
Dengyou Liu  Qimei Luo 《Talanta》2010,82(4):1175-3930
A simple, reusable and ultrasensitive electrochemical clinic immunoassay is proposed via developing a versatile CTDONG (conductive three-dimensional ordered nano-gold) film-modified gold electrode, in which ferrocene derivative and human immunoglobulin G (hIgG) are used as signaling probe and model molecule, respectively. A signal-on signaling mechanism is achieved by utilizing a sandwich format of the primary antibody/hIgG/the secondary antibody labeled with Ferrocene (PAb/Ag/SAb). Owing to the combination of the advantages of CTDONG film with the versatility of ferrocene derivatives, a substantially enhanced signal accompanied by a low background peak current is achieved. By this sensing scheme, target molecule can be readily quantified in a comparatively wide dynamic range (8.1 × 10−13-6.2 × 10−10 M) with a relatively low detection limit (2.7 × 10−13 M). In addition to a greatly improved signal gain, this immunosensor gives a favourable reusability and good reproducibility. Moreover, the CTDONG film-based sensing interface shows excellent anti-interference ability to the coexistent proteins. Meanwhile, the recovery test and determination of target molecule in real samples have confirmed the feasibility of designed sensing system for clinic immunoassay of protein molecules, demonstrating the potential application of described CTDONG film in the development of biomolecule assay platforms.  相似文献   

15.
M. Ghiaci  R.J. Kalbasi 《Talanta》2007,73(1):37-45
The main purpose of this study is to develop an inexpensive, simple, selective and especially highly selective modified mixed-oxide carbon paste electrode (CPE) for voltammetric determination of Pb(II). For the preliminary screening purpose, the catalyst was prepared by modification of SiO2-Al2O3 mixed-oxide and characterized by TG, CHN elemental analysis and FTIR spectroscopy. Using cyclic voltammetry the electroanalytical characteristics of the catalyst have been determined, and consequently the modified mixed-oxide carbon paste electrode was constructed and applied for determination of Pb(II). The electroanalytical procedure for determination of the Pb(II) comprises two steps: the chemical accumulation of the analyte under open-circuit conditions followed by the electrochemical detection of the preconcentrated species using differential pulse anodic stripping voltammetry. During the preconcentration step, Pb(II) was accumulated on the surface of the modifier by the formation of a complex with the nitrogen atoms of the pyridyl groups in the modifier. The peak currents increases linearly with Pb(II) concentration over the range of 2.0 × 10−9 to 5.2 × 10−5 mol L−1 (r2 = 0.9995).The detection limit (three times signal-to-noise) was found to be 1.07 × 10−9 mol L−1 Pb(II). The chemical and instrumental parameters have been optimized and the effect of the interferences has been determined. The Proposed method was used for determination of lead ion in the real samples.  相似文献   

16.
We here reported a simple electrochemical method for the detection of tryptophan (Trp) based on the Ag@C modified glassy carbon (Ag@C/GC) electrode. The Ag@C core–shell structured nanoparticles were synthesized using one-pot hydrothermal method and characterized by scanning electron microscope (SEM), transmission electron microscope (TEM), and Fourier transform-infrared spectroscopy (FTIR). The electrochemical behaviors of Trp on Ag@C/GC electrode were investigated and exhibited a direct electrochemical process. The favorable electrochemical properties of Ag@C/GC electrode were attributed to the synergistic effect of the Ag core and carbon shell. The carbon shell cannot only protect Ag core but also contribute to the enhanced substrate accessibility and Trp-substrate interactions, while nano-Ag core can display good electrocatalytic activity to Trp at the same time. Under the optimum experimental conditions the oxidation peak current was linearly dependent on the Trp concentration in the range of 1.0 × 10−7 to 1.0 × 10−4 M with a detection limit of 4.0 × 10−8 M (S/N = 3). In addition, the proposed electrode was applied for the determination of Trp concentration in real samples and satisfactory results were obtained. The technique offers enhanced sensitivity and may trigger the possibilities of the Ag@C nanocomposite towards diverse applications in biosensor and electroanalysis.  相似文献   

17.
The migration of melamine monomers from food contact materials has aroused particular attention since the 2008 melamine-tainted milk scandal in China. However, the determination of melamine monomer’s migratory quantity (MMMQ) has remained an open question because of the complex sample pretreatment and the low sensitivity. Based on the hydrogen bonding interaction between DNA thymine and melamine, this paper described a simple and rapid method focusing on the measurement of MMMQ from melamine tableware by gold nanoparticles (GNPs) and dynamic light scattering (DLS). With the presence of probe DNA (p-DNA), the GNPs were stable in NaCl solution (0.06 M), whereas they became aggregated when the p-DNA hybridized with melamine. The change in the hydrodynamic diameter of GNPs could be detected by DLS technology. Under the optimal conditions, the average diameter increased linearly with the concentration of melamine over the range from 5.0 to 320.0 μg L−1, and showed a detection limit of 2.0 μg  L−1 (3σ/slope). The MMMQ was investigated within a range from 6.00 × 10−4 to 2.58 × 10−1 mg dm−2 (n ≥ 3) in four different food simulants at different temperatures and time points. The results suggest that the DLS method has great potential in the analysis of the migration of melamine monomers.  相似文献   

18.
A simple and highly selective electrochemical method was developed for the single or simultaneous determination of paracetamol (N-acetyl-p-aminophenol, acetaminophen) and caffeine (3,7-dihydro-1,3,7-trimethyl-1H-purine-2,6-dione) in aqueous media (acetate buffer, pH 4.5) on a boron-doped diamond (BDD) electrode using square wave voltammetry (SWV) or differential pulse voltammetry (DPV). Using DPV with the cathodically pre-treated BDD electrode, a separation of about 550 mV between the peak oxidation potentials of paracetamol and caffeine present in binary mixtures was obtained. The calibration curves for the simultaneous determination of paracetamol and caffeine showed an excellent linear response, ranging from 5.0 × 10−7 mol L−1 to 8.3 × 10−5 mol L−1 for both compounds. The detection limits for the simultaneous determination of paracetamol and caffeine were 4.9 × 10−7 mol L−1 and 3.5 × 10−8 mol L−1, respectively. The proposed method was successfully applied in the simultaneous determination of paracetamol and caffeine in several pharmaceutical formulations (tablets), with results similar to those obtained using a high-performance liquid chromatography method (at 95% confidence level).  相似文献   

19.
Li H  Li J  Hou C  Du S  Ren Y  Yang Z  Xu Q  Hu X 《Talanta》2010,83(2):591-595
A ultrasensitive, simple and convenient electrochemical method was firstly developed for the determination of prochloraz and its metabolites as 2,4,6-trichlorophenol (2,4,6-TCP) using nano-aperture medical stone. Compared with the undoped disposable electrode (UDE), nano-aperture medical stone doped disposable electrode (MSDDE) not only significantly enhances the oxidation peak current of 2,4,6-TCP but also lowers the oxidation overpotential, suggesting that the nano-aperture MSDDE can remarkably improve the sensitivity of 2,4,6-TCP. The experimental conditions such as pH values of buffer solution, the content of nano-aperture medical stone, accumulation potential and time were optimized for the determination of 2,4,6-TCP. At optimal conditions, the oxidation peak current is proportional to the concentration of 2,4,6-TCP over the range from 6.0 × 10−9 to 8.0 × 10−5 mol L−1. Finally, this novel method was successfully employed to detect prochloraz and its metabolites in orange rind with the detection limit of 8.4 × 10−10 mol L−1 (0.3 ng g−1) and the method was validated by gas chromatography.  相似文献   

20.
This paper introduces a simple, fast and reliable electroanalytical method for differential-pulse polarography based on electrochemical reduction at a dropping mercury electrode. The method was validated for the determination of 2-ethylhexyl-4-methoxycinnamate (EHMC) alone and in association with 4-methylbenzylidene camphor (MBC) or 2-hydroxy-4-methoxybenzophenone (BENZ-3) in samples of commercial cosmetic preparations. The supporting electrolyte that provided the best-defined and most intense peak current for EHMC determination was Britton-Robinson buffer (pH 4.0) in the presence of a cationic surfactant. Under optimized conditions, EHMC exhibited one single peak of reduction at −1.49 V versus Ag/AgCl. A limit of detection of 3.76 × 10−8 mol L−1 and a limit of quantitation of 1.25 × 10−7 mol L−1 were found for the pure EHMC standard. A good average recovery rate was reached for all the samples analyzed.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号