首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 12 毫秒
1.
Adopting a stationary phase convention circumvents problematic definition of the boundary between the stationary and the mobile phase in the liquid chromatography, resulting in thermodynamically consistent and reproducible chromatographic data. Three stationary phase definition conventions provide different retention data, but equal selectivity: (i) the complete solid phase moiety; (ii) the solid porous part carrying the active interaction centers; (iii) the volume of the inner column pores. The selective uptake of water from the bulk aqueous‐organic mobile phase significantly affects the volume and the properties of polar stationary phases. Some polar stationary phases provide dual‐mode retention mechanism in aqueous‐organic mobile phases, reversed‐phase in the water‐rich range, and normal‐phase at high concentrations of the organic solvent in water. The linear solvation energy relationship model characterizes the structural contributions of the non‐selective and selective polar interactions both in the water‐rich and organic solvent‐rich mobile phases. The inner‐pore convention provides a single hold‐up volume value for the retention prediction on the dual‐mode columns over the full mobile phase range. Using the dual‐mode monolithic polymethacrylate zwitterionic micro‐columns alternatively in each mode in the first dimension of two‐dimensional liquid chromatography, in combination with a short reversed‐phase column in the second dimension, provides enhanced sample information.  相似文献   

2.
Rooibos tea, produced from the endemic South African shrub Aspalathus linearis, has various health-promoting benefits which are attributed to its phenolic composition. Generating reliable, quantitative data on these phenolic constituents is the first step towards documenting the protective effects associated with rooibos tea consumption. Reversed phase liquid chromatographic (RP-LC) methods currently employed in the quantitative analysis of rooibos are, however, hampered by limited resolution and/or excessive analysis times. In order to overcome these limitations, a systematic approach towards optimising the RP-LC separation of the 15 principal rooibos tea phenolics on a 1.8 μm phase using conventional HPLC instrumentation was adopted. Kinetic plots were used to obtain the optimal configuration for the separation of the target analytes within reasonable analysis times. Simultaneous optimisation of temperature and gradient conditions provided complete separation of these rooibos phenolics on a 1.8 μm C18 phase within 37 min. The optimised HPLC–DAD method was validated and successfully applied in the quantitative analysis of aqueous infusions of unfermented and fermented rooibos. Major phenolic constituents of fermented rooibos were found to be a phenylpropanoid phenylpyruvic acid glucoside (PPAG), the dihydrochalcone C-glycoside aspalathin, the flavones isoorientin and orientin, and a flavonol O-diglycoside tentatively identified as quercetin-3-O-robinobioside. Content values for PPAG, ferulic acid and quercetin-3-O-robinobioside in rooibos are reported here for the first time. Mass spectrometric (MS) and tandem MS detection were used to tentatively identify 13 additional phenolic compounds in rooibos infusions, including a new luteolin-6-C-pentoside-8-C-hexoside and a novel C-8-hexosyl derivative of aspalathin reported here for the first time.  相似文献   

3.
非线性电泳   总被引:1,自引:0,他引:1  
陈义 《色谱》2011,29(1):1-2
电泳大家当已耳熟能详了,它发现于18世纪初期,有悠久的历史.电泳因Tiselius而进入分离领域,为蛋白质科学的建立和发展立下了汗马功劳.其贡献至今不息,一直是生物学家的掌中宝.  相似文献   

4.
 Column packings continue to evolve as the needs of users for high efficiency, high resolution and highly sensitive high performance liquid chromatographic (HPLC) analysis drive further developments. In comparing and contrasting modern HPLC columns technologies, diameters of column packings and particle materials are covered. Some products and applications of modern HPLC columns are provided. Future directions in packing developments are predicted in this introductory article.  相似文献   

5.
It is shown through reversed phase high performance liquid chromatography that a characteristic feature of such abundant natural flavonoids as flavon-3-ols is an anomalously strong antibate dependence of their retention indices (RI) on the organic solvent concentration (C) in the eluent, dRI/dC < 0. In order to interpret this anomaly, the specific optical rotation values [α]D20 of natural (+)-(2R,3R)-dihydroquercetin in different solvents are compared, confirming the reverse formation of hydrated flavonoids in aqueous solutions.  相似文献   

6.
The first HPLC method for the separation of three paraben preservatives (methyl-, ethyl- and propyl parabens) using a core-shell analytical column is reported in this study. The separation was completed in less than 8 min at a low flow rate of 0.4 mL min−1 and an isocratic mobile phase containing 20% acetonitrile as organic modifier. The backpressure was < 200 bar in all cases, enabling the usage of conventional HPLC equipment. The proposed analytical procedure was validated for linearity (0.5–20 μg L−1), limits of detection (15–43 μg L−1) and quantification (50–142 μg L−1), selectivity, within day (1.3–1.5%) and day-to-day (3.4–4.6%) precision and accuracy. The proposed method has been applied to the determination of the selected paraben preservatives in commercially available hygiene wipes. The mean percent recoveries were found to be in the range of 98.0–98.4%.   相似文献   

7.
The chromatographic performance of the deuterated solvents, CD3OD and D2O, has been investigated in reversed-phase micro high performance liquid chromatography. The chromatographic performance of CD3OD is only slightly superior to that of CH3OH. However, the performance of D2 is significantly superior to that of H2O, separation of aromatics being improved by about 30%. D2 is a particularly powerful solvent for the separation iof deuterated and non-deuterated compounds.  相似文献   

8.
The hydrophilic interaction chromatography (HILIC) like properties of an ACE cyano (CN) HPLC column was studied for the separation of some basic compounds. Good separation of a test mix of basic compounds was obtained with a mobile phase consisting of acetonitrile/water (95:5) containing 3.25 mM ammonium acetate. The retention times of the basic compounds decreased with increased ionic strength or with increased water content in the mobile phase. When Trishydroxymethyl aminomethane (Tris) (pK(a) 8.0), which is a weaker amine than ammonia (pK(a) 9.3), was used as an additive in the mobile phase retention of the basic compounds was increased. The ACE CN column gave excellent peak shapes for all the basic compounds. The utility of the column for impurity profiling of two basic drugs was tested and some impurities in oxprenolol were characterised by interfacing with Fourier transform mass spectrometry. It was also observed that ACE butyl and ACE phenyl columns retained basic compounds when the columns were eluted with a mobile phase consisting of acetonitrile/water (95:5) containing 3.25 mM ammonium acetate.  相似文献   

9.
The retention behavior of uranium, thorium and lanthanides has been investigated with amide modified reversed phase C18 supports using α-hydroxy isobutyric acid (α-HIBA) as the mobile phase. Four structurally different amide moieties namely, 4-hydroxy-N,N-dihexyl butyramide (4HHBA), 4-hydroxy-N,N-di-2-ethylhexylhexanamide (4HEHHA), bis(N,N,N′,N-2-ethylhexyl)malonamide (B2EHM) and N-methyl-tris(dihexylcarbamoyl-3-methoxy)pivolamide (MTDCMPA) have been synthesized and studied. Among the various amide coated columns, the supports modified with 4HHBA, B2EHM and MTDCMPA exhibit an interesting retention for uranium and thorium, which is different from 4HEHHA modified support. The retention time for uranium and thorium increases with increasing amide concentration for 4HHBA, B2EHM and MTDCMPA supports, while the same decreases with increasing 4HEHHA content. However, the separation factor for uranium and thorium is greater on a 4HEHHA support, compared to an unmodified C18 column, reflecting the amide's preferential complexation of uranium over thorium.Columns modified with 4HHBA, B2EHM and MTDCMPA exhibit relatively higher retentions for lanthanides. However, MTDCMPA modified support shows a different elution profile for lanthanides compared to 4HHBA, and B2EHM modified columns. Individual separations of heavier lanthanides, i.e., from gadolinium to lutetium also have been achieved using 4HHBA and B2EHM modified supports.The influence of modifier content, mobile phase concentration and its pH on the retention of metal ions has also been studied. Based on these investigations, an efficient high performance liquid chromatographic method (HPLC) has been developed for the rapid separation of uranium from thorium as well as for the individual separation of heavier lanthanides.  相似文献   

10.
许丽丽  衷明华  陈小静 《色谱》2015,33(5):461-467
采用固液相表面连续反应法,先将偶联剂γ-[(2,3)-环氧丙氧]丙基三甲氧基硅烷(KH-560)键合到球形硅胶表面,然后再将植物有效成分丁香酚与硅胶上的KH-560活性基团反应,合成了丁香酚键合硅胶液相色谱固定相(EGSP)。采用元素分析、热重分析和红外光谱对该固定相的结构进行了表征。以萘作为溶质探针,乙腈-水(35:65, v/v)为流动相,流速为0.8 mL/min,测得EGSP柱的柱效。以一系列的中性、碱性和酸性化合物为溶质探针,C18柱和苯基柱作参比,对该固定相的色谱性能及保留机理进行了研究。结果表明,硅胶表面成功键合上了丁香酚配体,键合量为0.28 mmol/g, EGSP柱理论塔板数约为24707 N/m。该固定相不仅具有良好的反相色谱性能,同时由于配体结构中含有芳环、烯基和甲氧基,还能与溶质发生π-π电荷转移、偶极-偶极和氢键作用。与传统的反相C18柱和苯基柱相比,EGSP在极性芳香族化合物的快速、简便分离中占优势。  相似文献   

11.
Separation science is an art of obtaining adequate resolution of the desired compounds in minimum time, and with minimum effort in terms of sample preparation and data evaluation. In LC, where selectivity is a main driving force for separation, the availability of different separation modes capable of operating at high flow rates is a way to make combined optimal use of selectivity, efficiency, and speed. The separation of polar and hydrophilic compounds is problematic in RP LC due to the poor retention. Hydrophilic interaction liquid chromatography (HILIC) is a more straightforward separation mode to address this problem. Herein, it is shown that separations in HILIC mode are equally efficient as for RP, providing a potential for very fast separations on short columns. This is not only facilitated by the low viscosity of the mobile phase compositions used, compared to typical RP eluents, but also due to higher column permeability. To exemplify this, baseline separations of uracil and cytosine are shown in less than 4 s and of Tamiflu and its main metabolite in less than 40 s, both under isocratic conditions. HILIC must therefore be considered having potential for high throughput purposes, and being an attractive candidate as the second separation dimension in 2-D HPLC.  相似文献   

12.
13.
A new hydrophobic interaction HPLC column is used for the rapid purification of proteinase inhibitors isolated from arrowhead. The inhibitors, partially purified by DEAE-cellulose column chromatography, are resolved into three components with a mobile phase gradient of decreasing salt concentration from 1.1 M ammonium sulfate in 0.01 M phosphate buffer to phosphate buffer alone. This new HPLC column is found to be very useful for rapid, semipreparative purification of hydrophobic protein and sample loading of up to 1.6 mg of inhibitors can be fully resolved on an analytical column.  相似文献   

14.
在H2SO4介质中, KMnO4氧化左羟丙哌嗪产生化学发光, 甲醛可增敏上述化学发光, 在此基础上建立了反相高效液相色谱(RP-HPLC)分离, 柱后化学发光检测左羟丙哌嗪的新方法, 并成功应用于血清中左羟丙哌嗪的测定. 在优化的实验条件下, 该法测定左羟丙哌嗪的线性范围为1.0×10-7~1.0×10-5 g/mL, 检出限(3σ)为3×10-8 g/mL. 对2.0×10-6 g/mL的左羟丙哌嗪进行11次平行测定, 其相对标准偏差为2.3%.  相似文献   

15.
孙元社  瞿其曙  于淑新  李霜霜  唐涛  李彤 《色谱》2016,34(12):1250-1254
采用扫描电镜、透射电镜和氮气吸附法对制备的新型核壳型色谱固定相进行了表征,结果表明该固定相单分散性好、表面放射状孔道壳层结构均一、孔径分布窄。对该核壳材料的表面进行C18键合修饰,考察其基本色谱性能,色谱柱的理论塔板数超过150000块/m,色谱峰峰形对称,甲苯与乙苯的保留因子之比为1.45,亚甲基选择性优异。将该核壳材料应用于汽车尾气中醛酮类化合物的检测,在优化的色谱条件下,2,4-二硝基苯肼(DNPH)衍生的醛酮类化合物在15 min内获得了较好的分离效果。该核壳型C18色谱固定相具有分离速度快、选择性好、柱效高等特点,适于复杂样品的高效、快速分离分析。  相似文献   

16.
反相高效液相色谱法同时分析三聚氰酸和三聚氰胺   总被引:2,自引:0,他引:2  
建立了同时分析三聚氰酸和三聚氰胺的反相高效液相色谱法.发现三聚氰酸和三聚氰胺在C8柱上的保留比在C18柱上明显要强,这一结果表明三聚氰酸和三聚氰胺在反相固定相中的保留并非以通常的疏水分配作用为主导.方法的紫外检测下限为0.034~0.31mg/L,标准曲线线性范围为0.5-100mg/L.方法不经特殊的样品前处理即可用于奶粉和游泳池水等样品中三聚氰酸和三聚氰胺的同时分析.  相似文献   

17.
A reversed-phase high-performance liquid chromatographic assay for the simultaneous quantitative determination of seven ginsenosides, Rb(1), Rb(2), Rc, Rd, Rg(1), Re and Rf in pharmaceutical preparations is described. Chromatographic separation was achieved in less than 20 min using a 250 x 4 mm Lichrospher, 5 microm, 100 A diol column with detection at 203 nm. The method was validated over the range of 2.5-20 ng/microL using a 20 microL sample volume. The average accuracy at five concentrations was 90-100%, and the within-day and between-day precision ranged from 1 to 7% expressed as coefficient of variation. The detection limit and the quantitation limit of the method were 20 and 50 ng injected for each ginsenoside, respectively.  相似文献   

18.
A sensitive and selective high performance liquid chromatographic doxophylline assay with ultraviolet detection has been developed for plasma samples. The drug is isolated from biological samples with a reversed phase C18 disposable extraction column. Plasma standard curves are linear for concentrations of doxophylline from 0.03 to 10 mg/L. At the therapeutic range concentrations, the recoveries are better than 96.9%. The coefficients of variation for the procedure are 4.1% and 2.7% for the concentrations 0.03 mg/L and 10 mg/L, respectively. By this method, pharmacokinetic profiles are obtained for six adult volunteers.  相似文献   

19.
许丽丽  任乃林  林泽玲 《色谱》2014,32(8):798-803
采用中间体法,先将大黄素配体与γ-[(2,3)-环氧丙氧]丙基三甲氧基硅烷(KH-560)偶联剂反应制备含配体的硅氧烷试剂,然后再与硅胶键合,最终制得大黄素键合硅胶液相色谱固定相(以下简称ESP)。通过红外光谱、元素分析和热重分析表征固定相的结构。以萘作为溶质探针,甲醇-水(60:40,v/v)为流动相,流速为0.8 mL/min,测得ESP柱的柱效。采用传统的反相C18和苯基柱作参比,将ESP应用于系列中性、碱性和酸性芳香族化合物以及实际样品风油精的分离分析,并探讨相关的色谱分离机理。结果表明,配体大黄素被成功地键合到球形硅胶表面,测得配体键合量为0.23 mmol/g,ESP柱理论塔板数约为19874 N/m。ESP的偶联剂链和蒽醌环提供了疏水性的结构基础,大黄素配体还能为溶质提供π-πp-π、电荷转移、氢键、偶极-偶极等作用点。多位点的协同作用使得ESP柱具有独特和优秀的色谱分离选择性,并且无需调节pH值,采用简单而廉价的甲醇-水流动相就能实现胺类、酚类等极性样品的基线分离,实验条件简单、方便。  相似文献   

20.
A pre-peak was separated from the main peak of a monoclonal antibody by size exclusion HPLC (SE-HPLC) analysis using two TSK-Gel G3000SWXL columns connected in series. When compared with molecular weight markers, the product peak elutes as a molecule with apparent molecular weight of 44 kDa, indicating that separation is not strictly on the basis of size exclusion and that longer retention of the antibody by this column probably results from interaction between the stationary phase and the protein molecules during separation. The pre-peak has been characterized as due to the oxidation of one of tryptophan residues on the heavy chains of this monoclonal antibody. Because the SE-HPLC method using tandem TSK-Gel G3000SWXL columns showed unsatisfactory reproducibility amongst column lots, a more reliable and accurate reversed phase HPLC (RP-HPLC) method was developed to detect the tryptophan oxidation on the heavy chains of the monoclonal antibody. The level of tryptophan oxidation determined by the reversed phase method was correlated with the amount of tryptophan oxidation observed as a pre-peak by SE-HPLC. The RP-HPLC method was qualified for precision, accuracy, linearity of the main peak and the minor peak (oxidized isoforms of the heavy chain), detection limit and quantitation limit.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号