首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
The on-line analysis of single aerosol particles with mass spectrometrical methods is an important tool for the investigation of aerosols. Often, a single laser pulse is used for one-step laser desorption/ionisation of aerosol particles. Resulting ions are detected with time-of-flight mass spectrometry. With this method, the detection of inorganic compounds is possible. The detection of more fragile organic compounds and carbon clusters can be accomplished by separating the desorption and the ionisation in two steps, e.g. by using two laser pulses. A further method is, using a heated metal surface for thermal desorption of aerosol particles. If an ultraviolet laser is used for ionisation, a selective ionisation of polycyclic aromatic hydrocarbons (PAH) and alkylated PAH is possible via a resonance-enhanced multiphoton-ionisation process. Laser velocimetry allows individual laser triggering for single particles and additionally delivers information on aerodynamic particle diameters. It was shown that particles deriving from different combustion sources can be differentiated according to their PAH patterns. For example, retene, a C4-alkylated phenanthrene derivative, is a marker for the combustion of coniferous wood. In this paper, the first field application of a thermal desorption resonance-enhanced multiphoton-ionisation single particle time-of-flight mass spectrometer during a measurement campaign in Augsburg, Germany in winter 2010 is presented. Larger PAH-containing particles (i.e. with aerodynamic diameters larger than 1 μm), which are suspected to be originated by re-suspension processes of agglomerated material, were in the focus of the investigation. Due to the low concentration of these particles, an on-line virtual impactor enrichment system was used. The detection of particle-bound PAH in ambient particles in this larger size region was possible and in addition, retene could be detected on several particles, which allows to identify wood combustion as generic source of these particles. The observed diurnal distribution of these larger particles, however, support the origin by traffic induced re-suspension of sedimented/agglomerated material.  相似文献   

2.
Fundamental parameters influencing the ion‐producing efficiency of palladium nanostructures (nanoparticles [Pd‐NP], nanoflowers, nanofilms) during laser irradiation were studied in this paper. The nanostructures were immobilized on the surface of different solid inorganic carrier materials (porous and mono‐crystalline silicon, anodic porous aluminum oxide, glass and polished steel) by using classical galvanic deposition, electroless local deposition and sputtering. It was the goal of this study to investigate the influence of both the nanoparticular layer as well as the carrier material on ion production for selected analyte molecules. Our experiments demonstrated that the dimensions of the synthesized nanostructures, the thickness of the active layers, surface disorders, thermal conductivity and physically or chemically adsorbed water influenced signal intensities of analyte ions during surface‐assisted laser desorption/ionization (SALDI) while no effects such as plasmon resonance, photoelectric effect or catalytic activity were expected to occur. Excellent LDI abilities were seen for Pd‐NPs immobilized on steel, while Pd nanoflowers on porous silicon exhibited several disadvantages; viz, strong memory effects, dependency of the analytical signal on amount of physically and chemically adsorbed water inside porous carrier, reduced SALDI activity from unstable connections between Pd and semiconductor material, decrease of the melting point of pure silicon after Pd immobilization and resulting strong laser ablation of metal/semiconductor complex, as well as significantly changed surface morphology after laser irradiation. The analytical performance of Pd‐NP/steel was further improved by applying a hydrophobic coating to the steel surface before galvanic deposition. This procedure increased the distance between Pd‐NPs, thus reducing thermal stress upon LDI; it simultaneously decreased spot sizes of deposited sample solutions. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

3.
Recently, we showed that the signal intensity of intact protein by matrix-assisted laser desorption/ionisation (MALDI) mass spectro-metry measurement can be enhanced at least an order of magnitude by the addition of Tween80 to the analyte solution. We did not ascertain whether this effect was limited to Tween80 or if it was more universal of biological detergents. This paper discusses our investigations into this question. A variety of chemically diverse detergents were added to analyte solutions containing bovine serum albumin (BSA) to determine whether there was significant signal enhancement. The addition of Tween20, Tween80, Triton X100 and Triton X-114 improved the attainable sensitivity of intact protein MALDI mass spectrometry compared to spectra acquired without detergent. In some cases there was considerable improvement in signal--for example, with Triton X-100 two charge states (the +1 and +2) of BSA (3.9 fmol) could easily be observed. Another advantage of this process is that the detergent can be added directly to the matrix solution reducing sample handling and preparation time. We propose this phenomenon results from the ability of these detergents to increase the solubility of the protein via hydrophobic and hydrophilic interactions between the detergent and protein. The increased solubility allows for more uniform deposition of the analyte/-matrix mixtures producing an evenly distributed layer of analyte especially useful for data acquisition using an automated laser firing sequence.  相似文献   

4.
We investigated a variant of desorption/ionization on porous silicon (DIOS) mass spectrometry utilizing an aqueous suspension of either porous silica gel or porous alumina (pore size of 60 and 90 A, respectively). Laser desorption/ionization (LDI) from samples directly deposited on a stainless steel surface without any inorganic substrates was also achieved. Synthetic peptides designed to cover large sequence diversity constituted our model compounds. Sample preparation, including material conditioning, peptide solubilization, and deposition protocol onto standard matrix-assisted laser desorption/ionization (MALDI) probe, as well as ionization source tuning were optimized to perform sensitive reproducible LDI analyses. The addition of either a cationizing agent or an alkali metal scavenger to the sample suspension allowed modification of the ionization output. Comparing hydrophilic silica gel to hydrophobic reversed-phase silica gel as well as increasing material pore size provided further insights into desorption/ionization processes. Furthermore, mixtures of peptides were analyzed to probe the spectral suppression phenomenon when no interfering organic matrix was present. The results gathered from synthetic peptide cocktails indicated that LDI mass spectrometry on silica gel or alumina constitutes a promising complementary method to MALDI in proteomics for peptide mass fingerprinting.  相似文献   

5.
Mass spectrometry imaging (MSI) is a comprehensive tool for the analysis of a wide range of biomolecules. The mainstream method for molecular MSI is matrix‐assisted laser desorption ionization, however, the presence of a matrix results in spectral interferences and the suppression of some analyte ions. Herein we demonstrate a new matrix‐free MSI technique using nanophotonic ionization based on laser desorption ionization (LDI) from a highly uniform silicon nanopost array (NAPA). In mouse brain and kidney tissue sections, the distributions of over 80 putatively annotated molecular species are determined with 40 μm spatial resolution. Furthermore, NAPA‐LDI‐MS is used to selectively analyze metabolites and lipids from sparsely distributed algal cells and the lamellipodia of human hepatocytes. Our results open the door for matrix‐free MSI of tissue sections and small cell populations by nanophotonic ionization.  相似文献   

6.
The signal intensity of low-molecular-weight compounds analyzed using surface-assisted laser desorption/ionization time-of-flight mass spectrometry (SALDI-TOF-MS) was significantly enhanced when oxidized graphitized carbon black (GCB) particles were used as the desorption/ionization surface. The surface of oxidized GCB contains more carboxylic acid groups than non-oxidized GCB. Carboxylic acid groups enhance the efficiency of the ionization process and the desorption of more hydrophobic compounds. A common pharmaceutical compound, propranolol, was successfully extracted from Baltic Sea blue mussels and quantified using oxidized GCB as the SALDI surface, whereas deuterated propranolol was used as the internal standard. The calibration curve showed a wide linear dynamic range of response (0.1–20 μg/mL) and good reproducibility (RSD < 10%). It was not possible to detect propranolol in Baltic Sea blue mussels when non-oxidized GCB was used as the SALDI surface.  相似文献   

7.
The generation of ions from silicon substrates in surface-assisted laser desorption ionization (SALDI) has been studied using silicon substrates prepared and etched by a variety of different methods. The different substrates were compared with respect to their ability to generate peptide mass spectra using standard liquid sample deposition. The desorption/ionization processes were studied using gas-phase analyte deposition. Mass spectra were obtained from compounds with gas-phase basicities above 850 kJmol and with molecular weights up to 370 Da. UV, VIS, and IR lasers were used for desorption. Ionization efficiencies were measured as a function of laser fluence and accumulated laser irradiance dose. Solvent vapors were added to the ion source and shown to result in fundamental laser-induced chemical and physical changes to the substrate surfaces. It is demonstrated that both the chemical properties of the substrate surface and the presence of a highly disordered structure with a high concentration of "dangling bonds" or deep gap states are required for efficient ion generation. In particular, amorphous silicon is shown to be an excellent SALDI substrate with ionization efficiencies as high as 1%, while hydrogen-passivated amorphous silicon is SALDI inactive. Based on the results, a novel model for SALDI ion generation is proposed with the following reaction steps: (1) the adsorption of neutral analyte molecules on the SALDI surface with formation of a hydrogen bond to surface Si-OH groups, (2) the electronic excitation of the substrate to form free electron/hole pairs (their relaxation results in trapped positive charges in near-surface deep gap states, causing an increase in the acidity of the Si-OH groups and proton transfer to the analyte molecules), and (3) the thermally activated dissociation of the analyte ions from the surface via a "loose" transition state.  相似文献   

8.
We investigated the thermal mechanism involved in laser desorption/ionization (LDI) of thermally labile molecules from the flat surfaces of amorphous Si (a-Si) and crystalline Si (c-Si). a-Si was selected for this study because of its thermal property, such as low thermal conductivity; thus, it was predicted to be highly susceptible to laser-induced surface heating. By virtue of lack of surface nanostructures, the flat surfaces offer a simple model system to focus on the thermal mechanism, avoiding other effects, including possible non-thermal contributions that can arise from the physical existence of surface nanostructures. For the energetics study, the internal energies of substituted benzylpyridinium ions produced by LDI on the bare and coated surfaces of a-Si and c-Si were obtained using the survival yield method. The results, including LDI thresholds, ion yields, and internal energies all suggested that the LDI mechanism would be indeed thermal, which is most likely promoted by thermal desorption caused by laser-induced surface heating. In addition, the LDI process driven by laser-induced thermal desorption (LITD) was also found to be capable of depositing an excessive internal energy in resulting LDI ions, which underwent a dissociation. It exhibited the essentially same features as in postsource decay (PSD) in MALDI-TOF/TOF mass spectrometry. We report that the LDI process by LITD offers not only a way of intact ionization but also a facile means for PSD of peptide ions, which this work demonstrates is well suited to peptide sequencing using TOF/TOF mass spectrometry.  相似文献   

9.
New Br?nsted acidic ionic liquids (BAILs) are prepared by treating zwitterions, which are composed of an imidazolium cation and a sulfonate anion, with an alkanedisulfonic acid. Acidification of the zwitterions produces the cation and deprotonation of the alkanedisulfonic acid forms the anion of the new BAILs. Direct laser desorption/ionisation (LDI), matrix-assisted LDI (MALDI) and electrospray ionisation (ESI) are employed to transfer ions into the gas-phase for detection by mass spectrometry and for dissociation studies by tandem mass spectrometry. The components of the BAILs are confirmed by LDI and MALDI by the detection of the respective cation and anion and by ESI by the observation of the cation and the dianion. A prominent feature of ESI is the formation of aggregates (cluster ions). Positively charged cluster ions are formally composed of multiple zwitterions plus one additional proton. In the negative-ion mode the clusters also incorporate the zwitterions which are, however, linked with the alkanedisulfonate dianion. In collision-induced dissociations (CID), the cationic aggregates show the evaporation of zwitterions until the protonated zwitterion is reached. Similarly, the cluster dianions release zwitterions until the free alkane disulfonate dianion is reached. However, the 1:1 adduct of dianion and zwitterion also displays proton transfer and Coulomb explosion into the mono-protonated disulfonic mono-anion and an imidazole-based carbene with sulfonate mono-anion.  相似文献   

10.
A method to obtain laser desorption/ionization mass spectra of organic compounds by depositing sample solutions onto a carbon substrate surface is demonstrated. The substrate consists of a thin layer of activated carbon particles immobilized on an aluminum support. In common with the porous carbon suspension samples used in previous “surface-assisted laser desorption/ionization” (SALDI) work, the mass spectra contain only a few “matrix” background ion peaks, minimizing interference with analyte ion peaks. The presence of glycerol ensured that the ion signals were stable over hundreds of laser shots. In addition, the carbon substrate surface has several advantages over the suspension samples. The use of a very thin layer of carbon significantly improves the sensitivity. Detection limits range from attomoles for crystal violet to femtomoles for bradykinin. Very little sample preparation is required as the analyte solution is simply pipetted onto the substrate surface and glycerol added. When using an alternate sample deposition method, a mass resolution for bradykinin of 1800 is achieved in linear time-of-flight mode. This is close to the resolution limit set by the detector system and above instrument specification for matrix-assisted laser desorption/ionization mass spectra.  相似文献   

11.
In this study, the influence of surface morphology, reagent ions and surface restructuring effects on atmospheric pressure laser desorption/ionization (LDI) for small molecules after laser irradiation of palladium self‐assembled nanoparticular (Pd‐NP) structures has been systematically studied. The dominant role of surface morphology during the LDI process, which was previously shown for silicon‐based substrates, has not been investigated for metal‐based substrates before. In our experiments, we demonstrated that both the presence of reagent ions and surface reorganization effects – in particular, melting – during laser irradiation was required for LDI activity of the substrate. The synthesized Pd nanostructures with diameters ranging from 60 to 180 nm started to melt at similar temperatures, viz. 890–898 K. These materials exhibited different LDI efficiencies, however, with Pd‐NP materials being the most effective surface in our experiments. Pd nanostructures of diameters >400–800 nm started to melt at higher temperatures, >1000 K, making such targets more resistant to laser irradiation, with subsequent loss of LDI activity. Our data demonstrated that both melting of the surface structures and the presence of reagent ions were essential for efficient LDI of the investigated low molecular weight compounds. This dependence of LDI on melting points was exploited further to improve the performance of Pd‐NP‐based sampling targets. For example, adding sodium hypophosphite as reducing agent to Pd electrolyte solutions during synthesis lowered the melting points of the Pd‐NP materials and subsequently gave reduced laser fluence requirements for LDI. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

12.
This review summarizes various approaches for the analysis of low molecular weight (LMW) compounds by different laser desorption/ionization mass spectrometry techniques (LDI-MS). It is common to use an agent to assist the ionization, and small molecules are normally difficult to analyze by, e.g., matrix assisted laser desorption/ionization mass spectrometry (MALDI-MS) using the common matrices available today, because the latter are generally small organic compounds themselves. This often results in severe suppression of analyte peaks, or interference of the matrix and analyte signals in the low mass region. However, intrinsic properties of several LDI techniques such as high sensitivity, low sample consumption, high tolerance towards salts and solid particles, and rapid analysis have stimulated scientists to develop methods to circumvent matrix-related issues in the analysis of LMW molecules. Recent developments within this field as well as historical considerations and future prospects are presented in this review.  相似文献   

13.
The adsorption behavior of poly(oxyethylene) nonyl phenyl ether nonionic emulsifier molecules onto polystyrene (PS) and styrene-methacrylic acid copolymer [P(S-MAA)] particles dispersed in D2O was evaluated by in situ 1H NMR measurements at room temperature. The resonance due to the protons of the emulsifier molecules was only observed. Normalized NMR integrals of the resonance due to the protons of hydrophobic groups (nonyl and phenyl groups) and the hydrophilic group, poly(oxyethylene) chain, at a certain concentration of the emulsifier decreased with an increase in the total surface area of the PS particles dispersed in the system. The decrease for the hydrophobic groups was much larger than that for the hydrophilic groups. In the dispersion system of P(S-MAA) particles, ionized carboxyl groups at the particle surface decreased the amount of the emulsifier adsorbed.  相似文献   

14.
利用激光解吸附电离飞行时间质谱技术获得了若干已知化学成分的气溶胶粒子的飞行时间质谱,分析标识了各类气溶胶粒子的特征离子谱峰,并对一些特征峰的形成机理进行了探讨。在此基础上,对烟花火药以及纸张燃烧产生的烟气气溶胶粒子进行了实时在线测量,通过对质谱图的分析,获得了有关此两类燃烧过程产生的烟气气溶胶单粒子的化学组成信息。  相似文献   

15.
In the electrodes of a proton-exchange membrane fuel cell, the hydrophilic-hydrophobic properties of the catalyst layers (CL), which contain a carbon substrate (CS), an ionomer in the form of Nafion resin, and a platinum catalyst, are investigated with standard contact porosimetry. Regularities in the influence of ionomer on the hydrophilic-hydrophobic properties of ten different CS, including Vulcan XC-72 carbon black, are investigated. The following plots are obtained: pore distribution curves with respect to radii, water desorption isotherms, moisture content distribution curves with respect to capillary pressure and to the free energy of binding water to material, and the wetting angle of water for the samples under investigation as a function of pore radius. It is established that both a hydrophobic effect and a hydrophilic effect occur in CL as a result of ionomer application to the CS under investigation. It is concluded that these different effects are determined by the orientation of the sulfonate groups (inside and outside) in the resin particles. This orientation depends on the extent of the binding of sulfonate groups to the CS surface by adsorption. CS surface properties are determined by the type and concentration of surface groups. Thus, the phenomenon of ionogenic-group inversion is established. When platinum is applied to CS, the CL become partially hydrophilic.  相似文献   

16.
Redox behaviour of four imidazophenazine dye derivatives under mass spectrometric conditions of matrix-assisted laser desorption/ionization (MALDI), laser desorption/ionization (LDI) from metal and graphite surface, electrospray, low temperature secondary ion mass spectrometry (LT SIMS) and fast atom bombardment (FAB) was studied and distinctions in the reduction-dependent spectral patterns were analyzed from the point of view of different quantities of protons and electrons available for reduction in different techniques. The reduction products [M + 2H](+*), [M + 3H](+) and M(-*), [M + H](-) were observed in the positive and negative ion modes, respectively, which permitted to suggest independent occurrence of reduction and protonation/deprotonation processes. LDI from graphite substrate was the only technique that allowed us to obtain abundant negative ions of all dye derivatives. The yield of field ionization (FI) or field desorption (FD) mechanism to ion formation under LDI from rough graphite surface has been addressed. The sensitivity of reduction of the dyes to variation of reduction-initiating agents confirms high redox activity of the dyes essential for their functioning in natural and artificial systems.  相似文献   

17.
In numerous studies charge remote fragmentation (CRF) has been shown to be a powerful technique for determination of primary structure by allowing location of double bonds, various functional groups, and branching in a variety of compound types directly by mass spectrometry. Instrumentation and ionization methods traditionally used for CRF, however, are becoming rare, in large part because ESI and MALDI have to a significant extent replaced them. Here we demonstrate that by selecting a matrix that promotes rather than suppresses ionization of fatty acids (FA) by lithium ion adduction, and using a TOF-TOF mass spectrometer for high-energy collisional activation, CRF ions are produced that allow location of double-bond and branching positions. Further, we show that by using solvent-free MALDI sample preparation methods, thus eliminating the inherent segregation of the hydrophobic fatty acid from the hydrophilic LiCl that can occur during the evaporation of solvent, the desired [FA-H+2Li](+) ions are greatly enhanced. Because FAs can be vaporized using laser desorption, matrix assistance in desorption of the fatty acid may occur, but is not necessary. However, the matrix plays a crucial role in enhancing or suppressing ionization. For example, matrix materials with acid (e.g., 2,5-dihydroxybenzoic acid) or hydroxy groups (e.g., dithranol) compete with the FA for Li(+) and because of the high ratio of matrix to analyte, FA lithium adduction is minimized. However, highly electron-deficient matrix materials (e.g., TCNQ) readily donate Li(+) to FAs because of the instability associated with being positively charged.  相似文献   

18.
A novel tandem time-of-flight (TOF) mass spectrometer has been developed for studying the photo-induced dissociation of large molecules and elemental clusters. It consists of a linear first stage TOF analyser for primary mass separation and precursor ion selection, and a second orthogonal reflecting field TOF analyser for product ion analysis. The instrument is equipped with a large volume throughput molecular beam source chamber allowing the production of jet-cooled molecules and molecular clusters, as well as elemental clusters, using either a pulsed laser vaporisation source (LVS) or a pulsed are cluster ion source (PACIS). A second differentially pumped chamber can be used with effusive sources, or for infrared laser desorption of large molecules, followed by laser ionisation. These primary ions can then be irradiated with a second, high energy laser to induce photodissociation. Detailed information about the fragmentation mechanisms can be deduced from the product ion mass spectra. Preliminary results on the photo-induced dissociation (PID) of the molecule ion of aniline at 266 nm are presented. In this case the molecule ions were generated via two-photon laser ionisation at 266 nm using an effusive source. Results for the collision-induced dissociation (CID) of the aniline molecule ion, using a commercial mass spectrometer equipped with an atmospheric pressure electrospray ionisation interface, are also presented. Copyright 2000 John Wiley & Sons, Ltd.  相似文献   

19.
Combustion-related soot particles were sampled in situ from the stoker system of a 0.5 MW incineration pilot plant (feeding material was wood) at two different heights over the feed bed in the third air supply zone. The collected particles were re-aerosolized by a powder-dispersing unit and analyzed by a single-particle laser desorption/ionization (LDI) time-of-flight mass spectrometer (aerosol-time-of-flight mass spectrometry, ATOFMS). The ATOFMS instrument characterizes particles according to their aerodynamic size (laser velocimetry) and chemical composition (LDI mass spectrometry). Chemical species from the particles are laser desorbed/ionized by 266 nm Nd:YAG laser pulses. ATOFMS results on individual 'real world' particles in general give information on the bulk inorganic composition. Organic compounds, which are of much lower concentrations, commonly are not detectable. However, recent off-line laser microprobe mass spectrometric (LMMS) experiments on bulk soot aerosol samples have emphasized that organic compounds can be desorbed and ionized without fragmentation in LDI experiments from black carbonaceous matrices. This paper reports the successful transfer of the off-line results to on-line analysis of airborne soot particles by ATOFMS. The detection of polycyclic aromatic hydrocarbons from soot particles is addressed in detail. The results are interpreted in the context of the recent LMMS results. Furthermore, their relevance with respect to possible applications in on-line monitoring of combustion processes is discussed.  相似文献   

20.
In spite of the growing acceptance of matrix‐assisted laser desorption/ionization time‐of‐flight mass spectrometry for the analysis of a wide variety of compounds, including polymers and proteins, its use in analyzing low‐molecular‐weight molecules (<1000m/z) is still limited. This is mainly due to the interference of matrix molecules in the low‐mass range. Here the derivatized fullerenes covalently bound to silica particles with different pore sizes are applied as thin layer for laser desorption/ionization (LDI) mass spectrometric analysis. Thus, an interference of intrinsic matrix ions can be eliminated or minimized in comparison with the state‐of‐the‐art weak organic acid matrices. The desorption/ionization ability of the developed fullerene–silica materials depends on the applied laser power, sample preparation and pore size of the silica particles. Thus, fullerene–silica serves as an LDI support for mass spectrometric analysis of molecules (<1500 Da). The performance of the fullerene–silica is demonstrated by the mass analysis of variety of small molecules such as carbohydrates, amino acids, peptides, phospholipids and drugs. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号