首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
In the present paper, a simple and sensitive method is proposed for vanadium(IV) determination in the presence of vanadium(V). This is based on the oxidation of vanadium(IV) present in the sample to vanadium(V) by addition of iron(III) cation, followed by a complexation reaction of iron(II) with the spectrophotometric reagent 2-(5-bromo-2-pyridylazo)-5-diethylaminophenol (Br-PADAP). The iron(II) reacts with Br-PADAP immediately, forming a stable complex with a large molar absorptivity. The vanadium(IV) determination is possible, with a calibration sensitivity of 0.549 g ml–1, for an analytical curve of 18.8 ng ml–1 to 2.40 g ml–1, molar absorptivity of 2.80 × 104 1 mole–1 cm–1 and a detection limit of 5.5 ng ml–1. Selectivity was increased with the use of EDTA as a masking agent. The proposed method was applied for the vanadium(IV) determination in the presence of several amounts of vanadium(V). The results revealed that 200 g of vanadium(V) do not interfere with determination of 5.00 g of vanadium(IV). The precision and the accuracy obtained were satisfactory (R. S. D.<2%).  相似文献   

2.
Summary p-Sulphobenzeneazo-4-(2-amino-3-hydroxypyridine) reacts with vanadium to form an orange-red coloured complex having maximum absorbance at 530 nm. The reaction is slow at room temperature, it is complete at 40–45° C in 5 min. The effects of temperature, time, pH, reagent concentration, and other variables have been studied. The system obeys Beer's law over the concentration range of 1–12g vanadium(V) ml–1. The molar absorptivity is 5.453 x 103l·mole–1·cm–1. The metal:ligand ratio of 12 was confirmed by Job's continuous variation and mole ratio methods.
Spektrophotometrische Bestimmung von Vanadin(V) mit p-Sulfobenzolazo-4-(2-amino-3-hydroxypyridin)
Zusammenfassung p-Sulfobenzolazo-4-(2-amino-3-hydroxypyridin) bildet mit Vanadin(V) einen orange-roten Komplex, dessen Absorptionsmaximum bei 530 nm liegt. Bei Zimmertemperatur verläuft die Reaktion langsam, bei 40–45° ist sie in 5 min vollständig. Der Einfluß von Temperatur, Zeit, pH, Reagenskonzentration und anderer variabler Faktoren wurde untersucht. Im Konzentrationsbereich 1–12g Vanadin/ml entspricht die Reaktion dem Beer-schen Gesetz. Die molare Absorptivität ist 5,453 x 103l·mol–1·cm–1. Das Verhältnis Metall:Ligand wurde nach Job bestimmt und beträgt 12.
  相似文献   

3.
Summary A differential pulse-polarographic method has been studied for the determination of vanadium employing the catalytic maximum wave. A well-defined differential pulse polarographic peak is observed in the potential range from –0.2 to –0.7 V vs. SCE for vanadium(V) in 10 mmol 1–1 NaCl containing 10 mmol 1–1 acetic acid, 40 mmol 1–1 pyrocatechol, and 2.5 mmol 1–1 KBrO3. The peak current is very large and proportional to the concentration of vanadium(V) between 1×10–7 and 1×10–6 mol 1–1. The relative standard deviation at 0.5 mol l–1 vanadium(V) was 2.06% (n=7). This method has been successfully applied to the determination of vanadium in standard materials such as pond sediment.
Spurenbestimmung von Vanadium mit Hilfe der katalytischen Maximumsstufe in der Differential-Puls-Polarographie
Zusammenfassung Ein gut definierter differentialpuls-polarographischer Peak wurde für Vanadium(V) in 10 mmol/l NaCl-Lösung, die 10 mmol/l Essigsäure, 40 mmol/l Brenzcatechin und 2,5 mmol/l KBrO3 enthielt, beobachtet (Potentialbereich –0,2 bis –0,7 V gegen SCE). Der Peakstrom ist sehr groß und die Vanadiumkonzentration im Bereich von 1×10–7 bis 1×10–6 mol/l proportional. Die relative Standardabweichung betrug 2,06% (n=7) bei 0,5 mol/l Vanadium(V). Das Verfahren wurde mit gutem Erfolg zur Vanadiumbestimmung in Standardproben (z.B. Teichsediment) eingesetzt.
  相似文献   

4.
The reaction between titanium(IV) and 2-(2-thiazolylazo)-p-cresol-(TAC) in aqueous methanol media at apparent pH 4.0–5.6 results in a intensely coloured complex that is stable for at least 2 h. The combining ratio is 1 1 cation TAC. Beer's law is obeyed up to 5.0 g/ml titanium(IV) at 580 nm. The apparent molar absorptivity at 580 nm is 9.82.103 l.mole–1.cm–1 and the detection limit obtained was 5 ng/ml titanium (IV). A spectrophotometric method for the simultaneous determination of titanium and iron with TAC is proposed.  相似文献   

5.
A new and simple method for selective spectrophotometric determination of uranium(VI) with 4-(2-pyridylazo)resorcinol (PAR) and N-octylacetamide into benzene over pH 7.0–9.0 is described. The molar absorptivity of the complex with 9 different amides is in the range of (0.40–3.2)·104 1·mol–1·cm–1 at the absorption maximum. Out of these, the most sensitive compound N-octylacetamide (OAA) was chosen for detailed studies in the present investigation. The detection limit of the method is 0.008 g U·ml–1. The system obeys Beer's law in the range of 0–5 g U·ml–1. The method is free from interferences of most of the common metal ions except vanadium(V) and copper(II), which are masked by proper masking agents. The composition of the complex is determined by curve-fitting method. The method has been applied for the recovery of the metal from rock samples and synthetic mixtures.  相似文献   

6.
A novel, sensitive and highly selective first derivative spectrophotometric method is proposed for the determination of vanadium(V) and iron(III) metal ions separately and simultaneously in a mixture. 2-Hydroxy-1-naphthaldehyde benzoylhydrazone (OHNABH) reacts with vanadium(V) and iron(III) in sodium acetate–acetic acid buffer medium (pH 5.0) forming yellow and yellowish brown colored soluble complexes, respectively. The first derivative curves of these colored solutions show maximum derivative amplitudes at 465 nm (V(V)) and 540 nm (Fe(III)) obeying Beer's law in the range 0.12–2.50 g ml–1 and 0.14–4.20 g ml–1, respectively. Large number of foreign ions do not interfere in the present method. A very simple and accurate simultaneous first derivative method is also reported for the determination of V(V) and Fe(III) in mixtures without solving simultaneous equations. The method is applied for the analysis of various natural samples, food and biological materials.  相似文献   

7.
Zusammenfassung Zum katalytischen Nachweis von Selen(IV) wird das Chlorat-Chlorid-Hydrazin-System empfohlen. Die Grenzkonzentration beträgt 0,004g Se/ml, die Grenzverdünnung 1 2,5 · 10–8.In Ultramikrokonzentration kann Selen(IV) mit der Simultankomparationsmethode oder chronometrisch auf Grund des LandoltEffektes bestimmt werden. V(V), Os(VIII) Cu(II), Mo(VI) und Te(IV) wirken in diesem System ebenfalls katalytisch.
Ultramicrodetermination of selenium(IV) by use of the chlorate-chloridehydrazine system
Summary Selenium(IV) may be catalytically detected by use of the chlorate-chloride-hydrazine system. This reagent is recommended. The limiting concentration is 0.004g Se/ml, the limiting dilution is 1 2.5 · 10–8. Ultramicro amounts of selenium(IV) may be determined with the simultaneous comparison method or chronometrically on the basis of the Landolt effect. V(V), Os(VIII), Cu(II), Mo(VI) and Te(IV) likewise have a catalytic effect in this system.
  相似文献   

8.
Summary A chemiluminescent method for the determination of vanadium in steel with cinchomeronic hydrazide as analytical reagent is proposed. The optimum conditions are pH 11.75 (phosphate buffer), 1.0×10–3 mol/l cinchomeronic hydrazide, 6.6×10–3 mol/l hydrogen peroxide and 2.8×10–3 mol/l V(IV). The maximum chemiluminescent emission is obtained at 420 nm. A linear relationship exists in the range of 0.04–1.00 g/ml of V(IV) with a 3.6% variation coefficient at 0.50 g/ml of V(IV) level for ten replicates. Cobalt(II), copper(II) and chromium(VI) show strong interference and a chloroform extraction procedure with -benzo-inoxime is recommended to avoid these interferences. This method has been applied to determine vanadium in a certified steel with excellent results.Presented at Euroanalysis VII  相似文献   

9.
A selective, sensitive and direct method for the spectrophotometric determination of vanadium in steels is developed in which vanadium is extracted withN-phenyl benzohydroxamic acid (PBHA) into chloroform from 5M hydrochloric acid medium followed by colour development by addition of 4-(2-pyridylazo)resorcinol (PAR) inN,N-dimethyl formamide (DMF). The vanadium(V)-PBHA-PAR mixed ligand complex shows maximum absorbance at 560 nm with a molar absorptivity 3.6 × 104 l mol–1 cm–1 and obeys Beer's law up to 2.0 g/ml of vanadium. The composition of the mixed ligand complex is determined by Job's method of continuous variations which revealed a 1 1 1 ratio for V(V) PBHA PAR. This method can be directly applied for the determination of vanadium in steels, while in the case of titanium base alloys, after separation of titanium matrix it gives good results even at 50–200 g of vanadium per gram level.  相似文献   

10.
Vanadium(IV) is determined by reaction with 3,5-dinitrosalicylic acid and rhodamine B in weakly acidic medium. The flotation of the ternary ion-association complex is carried out with cyclohexane followed by dissolution in acetone for subsequent spectrophotometric determination. The molar absorptivity is 5.91×105 l mole–1 cm–1 at 555 nm. Beer's law is obeyed in the range 0.05–1.5 g vanadium(IV) in 25 ml. The method is selective for vanadium(IV) in the presence of sodium fluoride and has been applied to standard reference materials.  相似文献   

11.
Zusammenfassung Es wurden Bedingungen für die photometrische Bestimmung von Mikrogrammengen Titan(IV) mit Brenzcatechinviolett in Anwesenheit von Gelatine bei 690 nm ausgearbeitet. Das Lambert-Beersche Gesetz gilt im Konzentrationsbereich 0,06–0,71g Ti/ml bei 1,6 cm Schichtdicke. Die beschriebene Bestimmung gehört zu den empfindlichsten photometrischen Bestimmungsmethoden für vierwertiges Titan.
Summary Conditions have been worked out for the photometric determination of micro amounts of titanium (IV) using pyrocatechol violet in presence of gelatin at 690 nm.Beers law is obeyed in the concentration range of 0.06 to 0.71g Ti/ml employing 1.6cm path length. The described determination is one of the most sensitive methods for tetravalent titanium.


IV. Mitteilung:Malát, M.: Chemist-Analyst51, 74 (1962).

Für die technische Hilfe sage ich. Frl.Iva Drailová meinen besten Dank.  相似文献   

12.
Summary A method for rapid extraction and spectrophotometric determination of cerium (IV) is described. The cerium-N-p-tolylbenzo-hydroxamic acid complex is extracted into chloroform at the pH 8.4 to 9.8. Maximum absorbance occurs between 460 and 470 nm. The values are reproducible at 465 nm and Beer's law is obeyed at this wavelength over the range of 0.03–40, per ml of the cerium(VI). The molar absorptivity of the cerium-p-TBHA complex is 4.6×103 l · mole–1 · cm–2 at 465. An attempt has been made to determine the cerium in sea water.
Zusammenfassung Eine Methode zur schnellen Extraktion und spektrophotometrischen Bestimmung von Cer(IV) wurde beschrieben. Der Cer-Komplex mit N-p-Tolylbenzohydroxamsäure wird bei pH 8,4–9,8 mit Chloroform extrahiert. Das Absorptionsmaximum liegt zwischen 460 und 470 nm. Bei 465 nm sind die Ablesungen reproduzierbar und wird das Beersche Gesetz zwischen 0,03 und 40g Cer/ml erfüllt. Die molare Extinktion des genannten Komplexes beträgt bei 465 nm 4,6 · 103 l · mol–1 · cm–2. Es wurde versucht, den Cergehalt von Meerwasser zu bestimmen.
  相似文献   

13.
Summary The distribution equilibria of 3-phenyl-3-methyl-2-mercaptopropenoic acid (PhMMP), pyridine and the titanium (IV)-PhMMP complex in the presence of pyridine have been studied in the chloroform-water system. An extraction-photometric method for the determination of micro amounts of titanium has been developed. The synergistic effect of pyridine, and the influence of pH, the reagent concentration and the presence of electrolytes and masking agents on the equilibrium have been determined. From slope analysis of the distribution curves, the composition of the extracted species has been found to be Ti(OH)2(HR)2·py. The complex is extracted quantitatively. Beer's law is obeyed over the range 0.09–4.30g/ml titanium (IV) and the molar absorptivity is 1.30×1041·mole–1·cm–1 at 447 nm. The method has been applied to the determination of titanium in ceramics.
Über die Extraktion und spektrophotometrische Bestimmung von Titan(IV) mit 3-Phenyl-3-methyl-2-mercaptopropensäure mit Hilfe der synergistischen Wirkung des Pyridins
Zusammmenfassung Das Verteilungsgleichgewicht von 3-Phenyl-3-methyl-2-mercaptopropensäure (PhMMP), Pyridin und Titan-PhMMP-Komplex in Gegenwart von Pyridin wurde in einem Wasser-Chloroform-System untersucht. Eine extraktionsphotometrische Methode für die Bestimmung von Mikromengen Titan(IV) wurde ausgearbeitet. Die synergistische Wirkung des Pyridins sowie der Einfluß des pH, des Reagens und der Gegenwart von Elektrolyten und maskierenden Reagenzien in der wäßrigen Phase auf das Gleichgewicht wurden bestimmt. Aus der Richtung der Verteilungskurven wurde für den extrahierten Komplex die Zusammensetzung Ti(OH)2(HR)2·py ermittelt. Der Komplex wird quantitativ extrahiert. Das Beersche Gesetz ist von 0,09–4,30g·ml–1 Ti(IV) erfüllt, der molare Absorptionskoeffizient ist 1,13·1041·mol–1·cm–1; die Sandell-Empfindlichkeit beträgt 3,7ng·cm–2 bei 447 nm. Diese Methode wurde für die Bestimmung von Titan in keramischem Material verwendet.
  相似文献   

14.
Zusammenfassung Die Verfasser untersuchten das Chlorat-Chlorid-Zinn(II)-Landolt-System. Mit dessen Reaktion können 0,2g Vanadin/5 ml nachgewiesen werden. Das Landolt-System ist bei Anwendung der Simultankomparationsmethode zur Bestimmung von Vanadin in Mikrogrammengen geeignet; eine Genauigkeit von 1 bis 5% kann dabei erreicht werden. In diesem System wird auch durch Mo(VI), Fe(III), Ti(IV), W(VI), Se(IV) und Te(IV) ein katalytischer Effekt ausgeübt, hingegen wirken Os(VIII) und Cu(II) auf die katalysierte Reaktion stark behindernd.
Summary The authors studied the chlorate-chloride-tin(II)-Landolt system. Its reaction revealed 0.2g vanadium in 5 ml. The Landolt system is suitable for the determination of vanadium in microgram amounts by the simultaneous comparison method; a precision of 1–5% can be attained. A catalytic effect is exerted in this system also by Mo(VI), Fe(III), Ti(IV), W(VI), Se(IV), and Te(IV). On the other hand, Os(VIII) and Cu(II) have a marked inhibiting effect on the catalyzed reaction.

Résumé Les auteurs ont étudié la réaction deLandolt avec le système chlorate-chlorure-étain-II. Elle permet de déceler jusqu'à 0,2g de vanadium dans 5 ml. Elle peut être appliquée à la méthode de comparaison simultanée pour le dosage du vanadium en quantités de l'ordre du microgramme, en atteignant ainsi la précision de 1–5%. On trouve aussi dans cette réaction un effet catalytique du Mo-VI, Fe-III, Ti-IV, W-VI, Se-IV et Te-IV, tandis que Os-III et Cu-II gênent fortement la réaction catalysée.
  相似文献   

15.
Summary Applications of Catalytic Reactions. Kinetic Microdetermination of W(VI) and V(V) A kinetic method is described for the microdetermination of tungsten and vanadium. The method is based on the catalytic action of tungstate and vanadate ions on the oxidation of 2,4-diaminophenol with hydrogen peroxide. The effect of reagent concentration is studied and the maximum tolerable amounts of interfering ions are determined. Procedures for the determination of 0.46 to 73.5g/ml tungsten are given with a relative error of about 1.5%. Quantities of 2.02·10–2 to 2.5g/ml vanadium could be determined with a relative error of about 2%.Furthermore a kinetic determination of tungstate and vanadate ions in their mixtures is proposed.Part of PhD Thesis-University of Thessaloniki, 1975.  相似文献   

16.
The preparation of no-carrier-added48V(IV) and48V(V) from a natural titanium target irradiated by a proton beam has been developed. The48V recovered from the target by solvent extraction was purified as48V(V) with a cation exchange column and then converted to48V(IV) by reduction with ethanol. One hour irradiations at 10 A of 18 MeV protons gave approximately 2mCi (a radiochemical yield of 41%) of radiochemically pure and almost salt-free48V(IV) and48V(V) with high specific activities. They were shown to be suitable for biological tracer use.  相似文献   

17.
Zusammenfassung Die Bestimmung von 800 bis 30g Pb(II) durch potentiometrische Titration mit Molybdat unter Verwendung einer bleispezifischen Elektrode wurde untersucht. Unter geeigneten Bedingungen sind mit 4·10–3 M Molybdat 800 bis 300g Pb(II) in wäßriger Lösung mit einer Genauigkeit von ±0,57% bzw. 0,45% und einer Reproduzierbarkeit von ±0,43% bzw. ±0,30% (Standardabweichung=0,25% bzw. 0,17%) je nach Titrationsart automatisch bzw. manuell bestimmbar.Zur Bestimmung von Pb(II)-Mengen <300g ist eine 2·10–3 M Molybdatlösung zu verwenden. 300 bis 100g Pb(II) sind in wäßriger Lösung mit zufriedenstellenden Resultaten bestimmbar, jedoch verbessert eine Titration in 40% igem Ethanol nicht nur die Genauigkeit in diesem Bereich, sondern erlaubt auch noch 30g Pb(II) mit einer Genauigkeit von ±1% und einer Reproduzierbarkeit von ±2% (Standardabweichung aus 20 Titrationen von 100g Pb(II)= 0,60%) zu bestimmen.Die Titration von 300–800g Pb(II) in wäßriger Lösung und von 30–300g Pb(II) in 40% igem Ethanol läßt sich auch in 0,1M NaNO3– 0,1M NaClO4– Lösung durchführen und ermöglicht somit auch zuverlässige Bleibestimmungen in organischen Verbindungen nach Mineralisierung mit HNO3–HClO4–H2O2.
The determination of 800 to 30 g lead(II) by potentiometric titration with molybdate
Summary The determination of 800 to 30g Pb(II) by potentiometric titration with molybdate by using a lead(II)-selective electrode was investigated. Under suitable conditions, 800 to 300g Pb(II) in aqueous solution by automatic or manual titration with 4·10–3 M molybdate can be determined with an accuracy of ±0.57% and ±0.45% and a precision of ±0.43% and 0.30% (standard deviation=0.25% and 0.17%, resp.).For determining amounts of Pb(II) below 300g, a 2·10–3 M molybdate solution has to be used. Although 300 to 100g Pb(II) are determinable again in water with satisfactory results, the titration in 40% ethanol is however more reliable: in this medium, amounts of 300 to 30g Pb(II) can be determined with an accuracy of ±1% and a precision of ±2% (standard deviation from 20 titrations of 100g Pb(II)=0.60%).The titration of 300–800g Pb(II) in water and of 30–300g Pb(II) in 40% ethanol is also possible in 0.1M NaNO3– and 0.1M NaClO1– medium and can be used in the lead determination in organic compounds after mineralization with HNO3-HClO4-H2O2.
  相似文献   

18.
Summary Traces of titanium in sea water have been preconcentrated by anion-exchange from acidified samples in the presence of thiocyanate. Titanium adsorbs strongly on a column of Amberlite CG 400 (SCN) and can be stripped easily by elution with 2 M hydrochloric acid — 1.5% hydrogen peroxide solution. Titanium in the effluent is determined spectrophotometrically with diantipyrylmethane as colour reagent. The combined method allows to determine traces of titanium very selectively and sensitively in sea water as well as non-saline water on a 41 sample basis. The method yields a coefficient of variation of 7% at a titanium level of 0.4 g per l.
Kombinierte Anionenaustauscher-Trennung und spektralphotometrische Bestimmung von Titanspuren in Meerwasser
Zusammenfassung Titanspuren wurden in Gegenwart von Thiocyanat durch Anionenaustausch aus der angesäuerten Probe angereichert. Titan wird an Amberlite CG 400 (SCN) stark adsorbiert und kann durch Elution mit 2M HCl — 1,5% H2O2 leicht abgelöst werden. Im Eluat wird es spektralphotometrisch mit Diantipyrylmethan bestimmt. Die kombinierte Methode gestattet eine selektive und empfindliche Bestimmung in einer 41-Probe von Meer- oder auch Süßwasser. Für einen Gehalt von 0,4 g Ti/l beträgt der Variationskoeffizient 7%.
  相似文献   

19.
Summary The blue iridium(IV)-diphenylcarbazone complex, formed by heating the solutions in boiling water bath for 45 minutes, having an absorption maximum at 550 nm with maximum molar absorptivity of 1.90·104l·cm–1·mole–1 (within 1.5 %) is recommended for the spectrophotometric determination of 40–240g iridium(IV) in 25–60 % ethanol medium. The complex formed in solutions at pH 3.5–7.0, after formation, is stable within the pH range 2.5 to 9.2. The effect of foreign ions has been investigated.
Zusammenfassung Der blaue Iridium(IV)-diphenylcarbazon-Komplex entsteht beim Erwärmen der beiden Lösungen im siedenden Wasserbad für 45 Min. Er hat ein Absorptionsmaximum bei 550 nm und eine molare Extinktion von 1,90 × 104 l·cm–1·mole–1. Diese Farbreaktion wird zur spektrophotometrischen Bestimmung von 40–240g Ir(IV) in 25-bis 60%igem Äthanol empfohlen. Der bei pH 3,5–7,0 entstandene Komplex ist zwischen pH 2,5 und 9,2 beständig. Der Einfluß von Fremdionen wurde untersucht.
  相似文献   

20.
Summary A method is described for the extractive spectrophotometric determination of palladium or ruthenium (III) using isonitrosoethylbenzoylacetate as the reagent. The yellow Pd-INEBA complex extracted into chloroform absorbs at 410 nm and conforms to Beer's law in the range of 10–110g of Pd per 10 ml of organic phase. The purple Ru-INEBA complex extracted into MIBK absorbs at 500 nm and conforms to Beer's law in the range of 25–125g of Ru per 10 ml of organic phase. The method affords the determination of both Pd and Ru in the presence of large number of cations and anions.
Flüssig-flüssig-Extraktion und spektrophotometriscbe Bestimmung von Palladium(II) und Ruthenium(III) mit Isonitrosoäthylbenzoylacetat (IÄBA)
Zusammenfassung Eine Methode für die Extraktion und spektrophotometrische Bestimmung von Pd oder Ru mit IÄBA wurde beschrieben. Der gelbe Pd-Komplex absorbiert in chloroformischer Lösung bei 410 nm und entspricht dem Beerschen Gesetz für 10–110g Pd/10 ml organische Phase. Der rote Ru-Komplex absorbiert in MIBK bei 500 nm und entspricht dem Beerschen Gesetz für 25–125g Ru/10 ml. Das Verfahren eignet sich für die Bestimmung der beiden Metalle in Gegenwart zahlreicher Kationen und Anionen.
  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号