首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A simple and sensitive high-performance liquid chromatography method is developed for the determination of orbifloxacin (ORB) in rabbit plasma. Sample preparations are carried out by adding phosphate buffer (pH 7.4, 0.1 M) and extracting with trichloromethane. ORB and the internal standard, norfloxacin (NOR), are separated on a reversed-phase column using an aqueous phosphate buffer-acetonitrile (80:20, v/v) mobile phase. The concentrations of ORB and NOR eluting from the column with retention times of 2.16 and 3.09 min, respectively, are monitored by fluorescence detection at 338 (excitation) and 425 nm (emission). The method is shown to be linear from 4 to 1500 ng/mL (regression coefficient r2 = 0.999). The quantitation and detection limits are 4 and 9 ng/mL, respectively. Mean recovery is determined as 92% by the analysis of plasma standards containing 150, 750, and 1500 ng/mL. Inter- and intra-assay precisions were 4 and 3%, respectively.  相似文献   

2.
To the best of our knowledge, bioanalytical methods to determine rosiglitazone in human plasma reported in literature use internal standards that are not commercially available. Our purpose was to develop a simple method for the determination of rosiglitazone in plasma employing a commercially available internal standard (IS). After the addition of celecoxib (IS), plasma (0.25 mL) samples were extracted into ethyl acetate. The residue after evaporation of the organic layer was dissolved in 750 microL of mobile phase and 50 microL was injected on to HPLC. The separation was achieved using a Hichrom KR 100, 250 x 4.6 mm C(18) with a mobile phase composition potassium dihydrogen phosphate buffer (0.01 m, pH 6.5):acetonitrile:methanol (40:50:10, v/v/v). The flow-rate of the mobile phase was set at 1 mL/min. The column eluate was monitored by fluorescence detector set at an excitation wavelength of 247 nm and emission wavelength of 367 nm. Linear relationships (r(2) > 0.99) were observed between the peak area ratio rosiglitazone to IS vs rosiglitazone concentrations across the concentration range 5-1000 ng/mL. The intra-run precision (%RSD) and accuracy (%Dev) in the measurement of rosiglitazone were <+/-10.69 and <-12.35%, respectively across the QC levels (50-1000 ng/mL). The extraction efficiency was >80% for both rosiglitazone and IS from human plasma. The lower limit of quantitation of the assay was 5 ng/mL. In summary, the methodology for rosiglitazone measurement in plasma was simple, sensitive and employed a commercially available IS.  相似文献   

3.
A simple, rapid and sensitive fluorescence high performance liquid chromatographic method was developed to determine propranolol concentration in the small volume of rat plasma without the solvent extraction step using pronethanol as the internal standard. The analysis was accomplished using a 5 microm CAPCELL PAK analytical cyano column at room temperature and a mobile phase consisted of 1% aqueous acetic acid containing 0.2% triethylamine and acetonitrile (65:35, v/v; pH 3.8). The flow-rate was kept at 0.5 mL/min and column effluent was monitored with a fluorescence detector at an excitation wavelength of 230 nm and an emission wavelength of 340 nm. Retention times for pronethalol and propranolol were 8.5 min and 10.5 min, respectively. Linear regressions for the standard curves were linear in the range 2-800 ng/mL, giving correlation coefficients above 0.998. The detection limit was 1.34 ng/mL. No analytical interference was observed from endogenous components in rat plasma. This simple and sensitive assay method was feasibly applied to the pharmacokinetic study of propranolol after intravenous administration of 2 mg/kg of propranolol to normal and carbon tetrachloride-induced liver cirrhotic rats.  相似文献   

4.
We developed a simple assay method for the determination of serum and urine norfloxacin and enoxacin using reversed‐phase high‐performance liquid chromatography and perchloric acid precipitation for sample pre‐treatment. Optimized conditions can permit detection of norfloxacin and enoxacin in the same chromatogram, so either compound can be used as an internal standard for another determinant. Supernatants of the precipitated samples were analyzed by the octadecylsilyl silica‐gel column under ambient temperature and an ultraviolet wavelength of 272 nm. A mobile phase solvent consisting of 20 mm sodium dihydrogenphosphate (pH 3.0) and acetonitrile (85:15, v/v) was pumped at a flow rate of 1.0 mL/min. The calibration curves for norfloxacin and enoxacin at a concentration of 62.5–1000 ng/mL for serum and 250–4000 ng/mL for urine were linear (r > 0.9997). The recoveries of norfloxacin and enoxacin from serum and urine were >94% with the coefficient of variations (CV) <5%. The CVs for intra‐ and inter‐day assay of norfloxacin and enoxacin were <4.2 and <5.5%, respectively. This method can be applied to the pharmacokinetic study of norfloxacin and enoxacin after repeated administration to assess changes in CYP1A2 activity in healthy subjects. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

5.
皮立  胡凤祖  师治贤 《色谱》2005,23(6):639-641
用所建立的高效液相色谱-荧光检测法测定了罂粟籽和火锅汤料中的罂粟碱。采用的色谱柱为RP-C18柱(250 mm×4.6 mm i.d.,5 μm);检测激发波长为285 nm,发射波长为355 nm;流动相为甲醇-0.02 mol/L乙酸铵(体积比为70∶30),流速0.8 mL/min。实验结果表明,罂粟碱的进样量为1×10-4~0.1 μg时其质量浓度与相应峰面积有良好的线性关系,最低检测限(以信噪比大于3计)达到0.02 ng。罂粟籽中罂粟碱的回收率为99.0%~100.8%。方法快速准确,简便灵敏,分离度高,能够满足有关食品中罂粟碱的检测要求。  相似文献   

6.
Four different stability-indicating procedures are described for determination of tiapride in pure form, dosage form, and human plasma. Second derivative (D2), first derivative of ratio spectra (1DD), spectrofluorimetric, and high-performance column liquid chromatographic (LC) methods are proposed for determination of tiapride in presence of its acid-induced degradation products, namely 2-methoxy-5-(methylsulfonyl) benzoic acid and 2-diethylaminoethylamine. These approaches were successfully applied to quantify tiapride using the information included in the absorption, excitation, and emission spectra of the appropriate solutions. In the D2 method, Beer's law was obeyed in the concentration range of 1.5-9 microg/mL with a mean recovery of 99.94 +/- 1.38% at 253.4 nm using absolute ethanol as a solvent. In 1DD, which is based on the simultaneous use of the first derivative of ratio spectra and measurement at 245 nm in absolute ethanolic solution, Beer's law was obeyed over a concentration range of 1.5-9 microg/mL with mean recovery 99.64 +/- 1.08%. The spectrofluorimetric method is based on the determination of tiapride native fluorescence at 339 nm emission wavelength and 230 nm excitation wavelength using water-methanol (8 + 2, v/v). The calibration curve was linear over the range of 0.2-3 microg/mL with mean recovery of 99.66 +/- 1.46%. This method was also applied for determination of tiapride in human plasma. A reversed-phase LC method performed at ambient temperature was validated for determination of tiapride using methanol-deionized water-triethylamine (107 + 93 + 0.16, v/v/v) as the mobile phase. Sulpiride was used as an internal standard at a flow rate of 1 mL/min with ultraviolet detection at 214 nm. A linear relation was obtained over a concentration range of 2-30 microg/mL with mean recovery of 99.66 +/- 0.9%. Results were statistically analyzed and compared with those obtained by applying the reference method. They proved both accuracy and precision.  相似文献   

7.
A simple chromatographic method is described for assaying 15 quinolones and fluoroquinolones (pipemidic acid, marbofloxacin, enoxacin, ofloxacin, norfloxacin, ciprofloxacin, danofloxacin, lomefloxacin, enrofloxacin, sarafloxacin, difloxacin, oxolinic acid, nalidixic acid, flumequine and piromidic acid), in urine and pharmaceutical samples. The determination was achieved by LC using an RP C18 analytical column. A mobile phase composed of mixtures of methanol-ACN-10 mM citrate buffer at pH 3.5 and 10 mM citrate buffer at pH 4.5, delivered under an optimum gradient program, at a flow rate of 1.5 mL/min, allows to accomplish the chromatographic separation in 26 min. For detection, diode-array UV-Vis at 280 nm and fluorescence detection set at excitation wavelength/emission wavelength: 280/450, 280/ 495, 280/405 and 320/360 nm were used. Detection and quantification limits were between 0.3-18 and 0.8-61 ng/mL, respectively. The method was validated in terms of interday (n = 6) and intraday (n = 6) precision and accuracy. The procedure was successfully applied to the analysis of human and veterinary pharmaceuticals. Also, ofloxacin was determined in human urine samples belonging to a patient undergoing treatment with this active principle, among others.  相似文献   

8.
A direct, accurate, and sensitive chromatographic analytical method for the quantitative determination of five fluoroquinolones (enoxacin, ofloxacin, norfloxacin, ciprofloxacin, and enrofloxacin) in chicken whole blood is proposed in the present study. For quantitative determination lamotrigine was used as internal standard at a concentration of 20 ng/microL. The developed method was successfully applied to the determination of enrofloxacin, as the main component of commercially available veterinary drugs. Fluoroquinolone antibiotics were separated on an Inertsil (250 x 4 mm) C8, 5 microm, analytical column, at ambient temperature. The mobile phase consisted of a mixture of citric acid (0.4 mol L(-1))-CH3OH-CH3CN (87:9:4% v/v) leading to retention times less than 14 min, at a flow rate 1.4 mL min(-1). UV detection at 275 nm provided limits of detection of 2 ng/mL per 20 microL injected volume for enoxacin, norfloxacin, and ciprofloxacin, 0.4 ng/mL for ofloxacin, and 4 ng/mL for enrofloxacin. Preparation of chicken blood samples is based on the deproteinization with acetonitrile while the pharmaceutical drug was simply diluted with water. Peaks of examined analytes in real samples were identified by means of a photodiode array detector. The method was validated in terms of within-day (n=6) precision and accuracy after chicken whole blood sample deproteinization by CH3CN. Using 50 microL of chicken blood sample, recovery rates at fortification levels of 40, 60, and 80 ng ranged from 86.7% to 103.7%. The applicability of the method was evaluated using real samples from chicken under fluoroquinolone treatment.  相似文献   

9.
A sensitive and accurate method was developed for the determination of streptomycin using HPLC followed by postcolumn derivatization and fluorometric detection. The analyte was extracted, using aqueous solution from cucumber and Chinese cabbage, by a two-step SPE procedure. The extraction, cleanup, and chromatography conditions were optimized, and the performance of the analysis method was evaluated. The conditions of chromatography were as follows: the separation was performed on a C18 column; the isocratic mobile phase consisted of acetonitrile and a mixed solution containing 10 mM sodium 1,2-naphthoquinone-4-sulfonate and 0.4 mM sodium 1-heptanesulfonate (25+75, v/v); and the flow rate was 1 mL/min. The fluorescence detector was set at an excitation wavelength of 263 nm and an emission wavelength of 435 nm. The calibration curve was linear over the range of 50-2000 ng/mL, with a correlation coefficient of 0.9995. The LOD and LOQ were 10 and 30 ng/g, respectively, in both cucumber and Chinese cabbage. The method was validated for selectivity, linearity, precision, and accuracy. The intraday and interday precision and accuracy were within 10%. The mean recoveries from spiked samples were more than 75%, with RSD lower than 10%.  相似文献   

10.
A sensitive, reliable and simple HPLC method was developed for the determination of lisinopril in human plasma. The method consists of extraction and clean‐up steps based on magnetic solid‐phase extraction and pre‐column derivatization with a fluorescent reagent. The mobile phase consisted of a mixture of methanol–sodium dihydrogen phosphate (pH 3.0; 0.005 m ; 75:25, v/v). The flow rate was set at 0.7 mL/min. Fluorescence detection was performed at 470nm excitation and 530nm emission wavelengths. Total chromatography run time was 5 min. The average extraction recovery of lisinopril and fluvoxamine (internal standard) was ≥82.8%. The limits of detection and quantification were determined as 1 and 3 ng/mL respectively. The method exhibited a linear calibration line over the concentration range of 3–1000 ng/mL with coefficient of determination (r2) of ≥0.98. The within‐run and between‐run precisions were satisfactory with values of CV of 1.8–12.8% (accuracy from 99.2 to 94.7%) and 2.4–13.7% (accuracy from 99.5 to 92.2%), respectively. These developments led to considerable improvement in method sensitivity and reliability. The method was validated according to the US Food and Drug Administration guidelines. Therefore, it can be considered as a suitable method for determination of lisinopril in plasma samples.  相似文献   

11.
建立了测定烤肉中苯并(α)芘含量的高效液相色谱法。采用CNW~Athena C_(18)色谱柱(250 mm×4.6 mm,5μm),流动相为甲醇–水(90∶10),流量为1.0 m L/min,柱温为35℃,进样体积为10μL,荧光检测器激发波长为365 nm,发射波长为410 nm,以色谱峰面积标准曲线法定量。苯并(α)芘的质量浓度在0~0.2μg/m L范围内与色谱峰面积呈良好的线性关系,相关系数为0.999 5,检出限为0.07μg/kg,加标回收率为91.3%~92.6%,测定结果的相对标准偏差为1.21%~1.40%(n=5)。该法样品预处理简便,检测时间短,灵敏度高,适用于烤肉中苯并(α)芘的含量测定。  相似文献   

12.
A novel LC-fluorescence detection method based on the use of a monolithic column for the determination of norfloxacin, ciprofloxacin, and enrofloxacin antibiotic residues in environmental waters was developed. Fluoroquinolones (FQs) were isocratically eluted using a mobile phase consisting of 0.025 M phosphoric acid solution at pH 3.0 with tetrabutylammonium and methanol (960:40, v/v) through a Chromolith Performance RP-18e column (100x4.6 mm) at a flow rate of 2.5 mL/min and detected at excitation and emission wavelengths of 278 and 450 nm, respectively. After acidification and addition of EDTA, water samples were extracted using an Oasis HLB cartridge. Linearity was evaluated in the range of 0.05 to 1 microg/mL and correlation coefficients of 0.9945 for norfloxacin, 0.9974 for ciprofloxacin, and 0.9982 for enrofloxacin were found. The limit of quantification was 25 ng/L for the three FQs. The recovery of FQs spiked into river water samples at 25, 50, and 100 ng/L fortification levels ranged from 76.5 to 91.0% for norfloxacin, 78.5 to 97.2% for ciprofloxacin, and 79.4 to 93.6% for enrofloxacin. This method was successfully applied to the analysis of water samples from the Mondego River, and ciprofloxacin and enrofloxacin residues were detected in eight water samples.  相似文献   

13.
In the present work, a sensitive, accurate and precise RP HPLC method has been established for simultaneous determination of sacubitril and valsartan from rat plasma by using irbesartan as an internal standard. Separation of analytes were carried out on monolithic column using 10?mM phosphate buffer (pH 2.6), methanol and acetonitrile in a proportion of 50:25:25 (v/v). Analytes were monitored using fluorescence detector maintained at an excitation wavelength of 249?nm and an emission wavelength was set at 380?nm till the elution of valsartan as well as internal standard and switched online to 320?nm for sacubitril. Analysis of analytes from rat plasma was carried out by protein precipitation using methanol and acetonitrile. Valsartan and sacubitril showed good linearity in the concentration range of 1–250?ng/ml and 1–200?ng/ml respectively, with good correlation coefficient (r2?≥?0.998). Further, the precision and accuracy of the proposed procedure were suitable as the percent relative standard deviation and percent relative error were well within the acceptable range. The average percent of recovery from the rat plasma was found to be 96.6% and 97.6% for valsartan and sacubitril respectively. The newly proposed method can be used for regular pharmacokinetic studies because of simplicity in sample preparation, short analysis time (<5?min) and good sensitivity.  相似文献   

14.
An improved simple, rapid and accurate HPLC method for quantification of doxorubicin derived from micelle-encapsulated or liposome-encapsulated doxorubicin formulation in rat plasma was described. The mobile phase consisting of a mixture of methanol-water [containing 0.1% formic acid anhydrous and 0.1% ammonia solution (25%), pH 3.0], 60:40, was delivered at a flow rate of 1.0 mL/min. Sample preparation for micelle- or liposome-encapsulated doxorubicin in rat plasma were achieved directly by protein precipitation with acetonitrile. Doxorubicin and daunorubicin (internal standard, IS) were separated on a C(18) reversed-phase HPLC column and quantified by a fluoresence detection with an excitation wavelength of 475 nm and an emission wavelength of 580 nm. The linearity was obtained over the range of 5.0-1000.0 ng/mL and 1.0-200.0 microg/mL for doxorubicin and the lower limit of quantitation was 5.0 ng/mL. For each level of quality control samples, inter- and intra-assay precision was less than 9.6 and 5.1% (relative standard deviation), respectively, and percentage error was within +/-2.6%. The extraction recoveries of doxorubicin in the range of 10 ng/mL to 100 microg/mL in rat plasma were between 94.1 and 105.6%. This method was successfully applied to the pharmacokinetic study of doxorubicin formulations after i.v. administration to rats.  相似文献   

15.
A simple high-performance liquid chromatographic method for the determination of doxazosin in human plasma was developed and validated. Prazosin was used as internal standard. After extraction twice with ethyl acetate, chromatographic separation of doxazosin in human plasma was carried out using a reversed-phase Apollo C18 column (250 x 4.6 mm, 5 microm) with mobile phase of methanol-acetonitrile-0.04 m disodium hydrogen orthophosphate (22:22:56, v/v/v) adjusted to pH 4.9 with 0.9 m phosphoric acid and quantified by fluorescence detection operated with an excitation wavelength of 246 nm and an emission wavelength of 389 nm. The lower limit of quantification (LLOQ) of this assay was 1 ng/mL using 500 microL human plasma. Linearity was established over the range 1-25 ng/mL (r2 > 0.9994). The intra- and inter-day accuracy ranged from 90.5 to 104.4% and the coefficient of variation were not more than 8.6% for both intra- and inter-day precision, over the range of the calibration curve. The absolute recoveries of doxazosin and prazosin from human plasma were more than 91%. Doxazosin demonstrated acceptable short-term, long-term and freeze-thaw stability in human plasma. The assay has been successfully applied to plasma sample ana-lysis for pharmacokinetic study.  相似文献   

16.
A sensitive HPLC method with pre-column fluorescence derivatization using 4-Fluoro-7-Nitrobenzofurazan (NBD-F) has been developed for the determination of gabapentin in pharmaceutical preparations. The method is based on the derivatization of gabapentin with (NBD-F) in borate buffer of pH 9.5 to yield a yellow, fluorescent product. The HPLC separation was achieved on a Inertsil C(18) column (250 mm × 4.6 mm) using a mobile phase of methanol water (80:20, v/v) solvent system at 1.2 mL/min flow rate. Mexiletine was used as the internal standard. The fluorometric detector was operated at 458 nm (excitation) and 521 nm (emission). The assay was linear over the concentration range of 5 50 ng/mL. The method was validated for specificity, linearity, limit of detection, limit of quantification, precision, accuracy, robustness. Moreover, the method was found to be sensitive with a low limit of detection (0.85 ng/mL) and limit of quantitation (2.55 ng/mL). The results of the developed procedure for gabapentin content in capsules were compared with those by the official method (USP 32). Statistical analysis by t- and F-tests, showed no significant difference at 95 confidence level between the two proposed methods.  相似文献   

17.
A rapid, accurate and sensitive method has been developed for the quantitative determination of four fluoroquinolone antimicrobial agents, enoxacin, norfloxacin, ofloxacin and ciprofloxacin, with high in-vitro activity against a wide range of Gram-negative and Gram-positive organisms.A Kromasil 100 C(8) 250 mm x 4 mm, 5 microm analytical column was used with an eluting system consisting of a mixture of CH(3)CN-CH(3)OH-citric acid 0.4 mol L(-1) (7:15:78 %, v/v). Detection was performed with a variable wavelength UV-visible detector at 275 nm resulting in limits of detection: 0.02 ng per 20 microL injection for enoxacin and 0.01 ng for ofloxacin, norfloxacin and ciprofloxacin. Hydrochlorothiazide (HCT) was used as internal standard at a concentration of 2 ng microL(-1). A rectilinear relationship was observed up to 2 ng microL(-1) for enoxacin, 12 ng microL(-1) for ofloxacin, 3 ng microL(-1) for norfloxacin, and 5 ng microL(-1) for ciprofloxacin. Separation was achieved within 10 min. The statistical evaluation of the method was examined by performing intra-day (n=8) and inter-day precision assays (n=8) and was found to be satisfactory with high accuracy and precision. The method was applied to the direct determination of the four fluoroquinolones in human blood serum. Sample pretreatment involved only protein precipitation with acetonitrile. Recovery of analytes in spiked samples was 97+/-6% over the range 0.1-0.5 ng microL(-1).  相似文献   

18.
Zafirlukast (ZAF) is a leukotriene receptor antagonist used in the treatment of chronic asthma. In this study, a simple and sensitive reversed-phase, high-performance liquid chromatographic method was developed for the determination of ZAF in pharmaceutical formulations and human plasma. Piribedil was used as an internal standard. Analysis was carried out on a Nucleosil C18 100 A (150 mm x 4.6 mm id, 5 Vm) column with acetonitrile-pH 3.0 acetate buffer (70 + 30, v/v) as the mobile phase at a flow rate of 0.8 mL/min. The peak was detected by an ultraviolet detector set at a wavelength of 240 nm. The retention times were about 3.9 min for piribedil and 5.8 min for ZAF. The developed method was applied to the determination of ZAF in its pharmaceutical formulation and spiked human plasma. For quantification of ZAF in spiked plasma, proteins were precipitated with ethanol before chromatographic analysis. The calibration range was linear from 49.69-437.50 ng/mL in spiked plasma. The absolute recovery from spiked plasma was 98.73 +/- 0.42% at a concentration of 254.78 ng/mL of ZAF. No endogenous substances from plasma were found to interfere.  相似文献   

19.
基于氟喹诺酮类药物与铽离子形成配合物后的荧光增强作用,建立了同时检测鸡肉中氟喹诺酮类(FQs)药物环丙沙星、诺氟沙星和恩诺沙星残留的Tb3+增敏高效液相色谱(HPLC)柱后衍生荧光检测方法。优化的实验条件如下:流动相为0.05 mol/L 醋酸/醋酸钠缓冲液(pH 6.0)-乙腈(体积比为89∶11),色谱柱为Hypersil BDS-C18,柱温40 ℃,流速0.8 mL/min;Tb3+浓度为8×10-5 mol/L;衍生反应温度40 ℃,衍生泵流速0.5 mL/min;荧光检测激发波长271 nm,发射波长545 nm。实验结果表明,将上述3种药物以1.0,10.0,50.0,100.0 ng/g水平添加到鸡肉后的回收率范围为66.3%~88.0%,相对标准偏差(RSD)均小于15.0%。定量分析的线性范围为0.1~500 ng/mL,方法的日内和日间RSD均小于13.0%;最低检出限分别为0.05(环丙沙星)、0.05(诺氟沙星)和0.08(恩诺沙星)ng/g,比前人报道的非衍生高效液相色谱荧光检测法检测FQs药物的灵敏度有极大的提高。该项研究为FQs药物多残留检测提供了灵敏度更高的新方法。  相似文献   

20.
Although the analytical literature seems abundant for the determination of metoprolol in human plasma, a method using standard equipment providing a sensitive and simple high-performance liquid chromatographic (HPLC) method for limited blood volume, e.g. where 1 mL of blood in a 1 kg infant equals 70 mL of adult blood volume, has rarely been addressed. Therefore, in 500 microL of plasma, metoprolol was extracted using an internal standard and solid-phase extraction columns. Chromatographic analysis was performed on a Spherisorb C(6) column (5 microm particle size) at ambient temperature and fluorimetric detection with an excitation wavelength of 225 nm, and emission wavelength of 310 nm. The mobile phase [30% acetonitrile and 70% 0.25 m potassium acetate buffer (pH 4)] was pumped with 1 mL/min. Metoprolol recovery was determined at 73.0 +/- 20.5%, and the limit of quantitation was 2.4 ng/mL. Precision values of intra- and inter-assay were below 15.5% and those for accuracy were between 90 and 110%. This method was developed for monitoring and determination of pharmacokinetic parameters of metoprolol in pediatric patients and therefore metoprolol plasma concentrations in a 2-year-old child with ventricular tachycardia are reported. .  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号