Liquid chromatography/atmospheric pressure photoionization tandem mass spectrometry (LC/APPI-MS/MS) was investigated as an instrumental method for the analysis of the halogenated norbornene flame retardants, Mirex, Dechloranes 602, 603, 604, and Dechlorane Plus (DP). The LC separation was optimized by screening a variety of stationary and mobile phases, resulting in a short LC separation time of 5 min. Different atmospheric pressure ionization approaches were examined including electrospray ionization, atmospheric pressure chemical ionization, and APPI, each with and without post-column addition. APPI without post-column addition was chosen for providing the best ionization response. The optimized LC/APPI-MS/MS approach resulted in instrument detection limits ranging between 25 and 50 pg. Good linearity was also achieved (up to 25.0 ng/μL; R >0.999). The method was applied to extracts of environmental samples including surface water, fish and sediments for screening purposes, and the results agreed well with those obtained by gas chromatography/mass spectrometry.  相似文献   

2.
In this report, a method for in-source hydrogen/deuterium (H/D) exchange at atmospheric pressure is reported. The method was named atmospheric pressure photo ionization hydrogen/deuterium exchange mass spectrometry (APPI HDX MS). H/D exchange was performed by mixing samples dissolved in toluene with CH3OD solvent and analyzing the mixture using atmospheric pressure photo ionization mass spectrometry (APPI-MS). The APPI HDX spectra obtained with contact times between the analyte solution and methanol-OD (CH3OD) of?<?0.5 s or 1 h showed the same pattern of H/D exchange. Therefore, it was concluded that APPI HDX occurred in the source but not in the solution. The proposed method does not require a specific type of mass spectrometer and can be performed at atmospheric pressure. H/D exchange can be performed in any laboratory with a mass spectrometer and a commercial APPI source. Using this method, multiple H/D exchanges of aromatic hydrogen and/or H/D exchange of active hydrogen were observed. These results demonstrated that H/D exchange can be used to distinguish between isomers containing primary, secondary, and tertiary amines, as well as pyridine and pyrrole functional groups.
Figure
?  相似文献   

3.
Analytical methods for the determination of several natural and synthetic steroids in water and solid samples were developed using liquid chromatography tandem mass spectrometry. Atmospheric pressure photoionization (APPI) in positive mode was used as the source which appeared to reduce background and interferences as compared to electrospray ionization. Toluene was identified as the most appropriate dopant and its concentration optimized to enhance ionization efficiency. Method detection limits were in the low-nanogram-per-liter range for water samples using on-line solid-phase extraction and near 0.2 ng/g using microwave-assisted solvent extraction for solid samples. This on-line method, using APPI as a source and toluene as a dopant, is beneficial as it saves time due to on-line extraction and reduces interference and matrix effects using gas-phase photoionization. Groundwater, wastewater, runoff, and soil samples were collected and analyzed using the method indicating that traces of several androgens, estrogens, and other steroid-like compounds do occur in samples impacted by animal waste.
Figure
Sensitive and simplified analysis of natural and synthetic steroids in water and solids using on-line solid phase extraction and microwave-assisted solvent extraction coupled to liquid chromatography tandem mass spectrometry atmospheric pressure photoionization  相似文献   

4.
In this study, we develop fast screening methods for flame retardants and plasticizers in products and waste based on direct probe (DP) atmospheric pressure photoionization (APPI) and atmospheric pressure chemical ionization (APCI) coupled to a high-resolution (HR) time-of-flight mass spectrometer. DP-APPI is reported for the first time in this study, and DP-APCI that has been scarcely exploited is optimized for comparison. DP-APPI was more selective than DP-APCI and also more sensitive for the most hydrophobic compounds. No sample treatment was necessary, and only a minimal amount of sample (few milligrams) was used for analysis that was performed within a few minutes. Both methods were applied to the analysis of plastic products, electronic waste, and car interiors. Polybrominated diphenylethers, new brominated flame retardants, and organophosphorus flame retardants were present in most of the samples. The combination of DP with HR mass spectra and data processing based on mass accuracy and isotopic patterns allowed the unambiguous identification of chemicals at low levels of about 0.025 % (w/w). Under untargeted screening, resorcinol bis(biphenylphosphate) and bisphenol A bis(bisphenylphosphate) were identified in many of the consumer products of which literature data are still very limited.
Figure
Direct probe APPI/APCI-HRMS for screening flame retardants and plasticizers  相似文献   

5.
Gas chromatography/mass spectrometry (GC/MS) is applied to the analysis of volatile and thermally stable compounds, while liquid chromatography/atmospheric pressure chemical ionization mass spectrometry (LC/APCI‐MS) and liquid chromatography/electrospray ionization mass spectrometry (LC/ESI‐MS) are preferred for the analysis of compounds with solution acid‐base chemistry. Because organic explosives are compounds with low polarity and some of them are thermally labile, they have not been very well analyzed by GC/MS, LC/APCI‐MS and LC/ESI‐MS. Herein, we demonstrate liquid chromatography/negative ion atmospheric pressure photoionization mass spectrometry (LC/NI‐APPI‐MS) as a novel and highly sensitive method for their analysis. Using LC/NI‐APPI‐MS, limits of quantification (LOQs) of nitroaromatics and nitramines down to the middle pg range have been achieved in full MS scan mode, which are approximately one order to two orders magnitude lower than those previously reported using GC/MS or LC/APCI‐MS. The calibration dynamic ranges achieved by LC/NI‐APPI‐MS are also wider than those using GC/MS and LC/APCI‐MS. The reproducibility of LC/NI‐APPI‐MS is also very reliable, with the intraday and interday variabilities by coefficient of variation (CV) of 0.2–3.4% and 0.6–1.9% for 2,4,6‐trinitrotoluene (2,4,6‐TNT). Copyright © 2008 John Wiley & Sons, Ltd.  相似文献   

6.
Electrospray ionization (ESI), atmospheric pressure chemical ionization (APCI), and atmospheric pressure photo-ionization (APPI) are the most important techniques for the ionization of liquid samples. However, working under atmospheric pressure conditions, all these techniques involve some chemical rather than purely physical processes, and therefore, side reactions often yield to matrix-dependent ionization efficiencies. Here, a system is presented that combines both soft single-photon ionization (SPI) and hard 70 eV electron impact ionization (EI) of dissolved compounds under vacuum conditions. A quadrupole mass spectrometer was modified to enable direct EI, a technique developed by Cappiello et al. to obtain library-searchable EI mass spectra as well as soft SPI mass spectra of sample solutions. An electron beam-pumped rare gas excimer lamp working at 126 nm was used as well as a focusable vacuum UV light source for single-photon ionization. Both techniques, EI and SPI, were applied successfully for flow injection experiments providing library-matchable EI fragment mass spectra and soft SPI mass spectra, showing dominant signals for the molecular ion. Four model compounds were analyzed: hexadecane, propofol, chlorpropham, and eugenol, with detection limits in the picomolar range. This novel combination of EI and SPI promises great analytical benefits, thanks to the possibility of combining database alignment for EI data and molecular mass information provided by SPI. Possible applications for the presented ionization technology system are a matrix-effect-free detection and a rapid screening of different complex mixtures without time-consuming sample preparation or separation techniques (e.g., for analysis of reaction solutions in combinatorial chemistry) or a switchable hard (EI) and soft (SPI) MS method as detection step for liquid chromatography.
Figure
Scheme of the interface for introduction of liquid samples for vacuum photoionization/electron impact ionization MS  相似文献   

7.
A comprehensive, sensitive and high-throughput liquid chromatography–atmospheric pressure photoionization tandem mass spectrometry (LC–APPI-MS/MS) method has been developed for analysis of 36 halogenated flame retardants (HFRs). Under the optimized LC conditions, all of the HFRs eluted from the LC column within 14 min, while maintaining good chromatographic separation for the isomers. Introduction of the pre-heated dopant to the APPI source decreased the background noise fivefold, which enhanced sensitivity. An empirical equation was proposed to describe the relation between the ion intensity and dopant flow. The excellent on-column instrument detection limits averaged 4.7 pg, which was similar to the sensitivity offered by gas chromatography–high-resolution mass spectrometry (GC–HRMS). This method was used to analyze a series of fish samples. Good agreement was found between the results for PBDEs from LC–APPI-MS/MS and GC–HRMS.  相似文献   

8.
9.
Ivano Marchi 《Talanta》2009,78(1):1-610
This review presents the state-of-the-art techniques that couple liquid chromatography (LC) and mass spectrometry (MS) via atmospheric pressure photoionization (APPI). The different ionization mechanisms are discussed as well as the influence of the mobile phase composition, the nature of the dopant, etc. A comparison with other ionization sources, such as electrospray ionization (ESI) and atmospheric pressure chemical ionization (APCI), is reported, and the combination of APPI with these sources is also discussed. Several applications, covering the time period of 2005-2008, for the analysis of drugs, lipids, natural compounds, pesticides, synthetic organics, petroleum derivatives, and other substances are presented.  相似文献   

10.
Atmospheric pressure photoionization (APPI) is a novel method of ionization in liquid chromatography/mass spectrometry (LC/MS). It was originally developed in order to broaden the range of LC/MS ionizable compounds towards less polar compounds that cannot be analyzed by electrospray (ESI) and atmospheric pressure chemical ionization (APCI). Studies done thus far have shown that non-polar compounds that earlier were not ionizable in LC/MS can indeed be ionized by the use of APPI. However, the best ionization efficiency for low polarity samples has been achieved with low proton affinity (PA) solvents that are not suitable in reversed-phase LC (RP-LC). Here it is demonstrated that the signals for analytes with low proton affinities in acetonitrile can be increased 100-fold by using anisole as the dopant for APPI, which takes the sensitivity to the same level achieved in the analysis of high PA analytes.  相似文献   

11.
In this work, 53 selected pesticides of different chemical groups were extracted from Chinese herbal medicines and determined by ultra-high-performance liquid chromatography (UHPLC)–tandem mass spectrometry (MS/MS) using both electrospray ionization (ESI) and atmospheric-pressure chemical ionization (APCI). Extracts were obtained using the acetonitrile-based quick, easy, cheap, effective, rugged, and safe (QuEChERS) sample preparation technique. Cleanup was performed by dispersive solid-phase extraction using primary secondary amine, graphitized carbon black, and octadecylsilane. Two atmospheric-pressure interfaces, ESI and APCI, were checked and compared. The validation study, including detection limits, linearity, and matrix effects, was conducted on fritillaria, radix ginseng, folium isatidis, semen persicae, and flos lonicerae in multiple reaction monitoring mode. These matrices represent a variety of plants used in traditional Chinese medicine. Fritillaria and radix ginseng were chosen as representatives for roots, folium isatidis was chosen as a representative for leaves, semen persicae was chosen as a representative for seeds, and flos lonicerae was chosen as a representative for flowers. The limits of detection for pesticides were lower in the UHPLC–ESI-MS/MS method than in the UHPLC–APCI-MS/MS method. Matrix effects on the two ionizations were evaluated for the five matrices. Soft signal enhancement in UHPLC–APCI-MS/MS and signal suppression in UHPLC–ESI-MS/MS were observed.
Figure
Overview of UPLC–MS/MS assay for comparing the APCI and ESI interfaces  相似文献   

12.
Analysis of 11 polybrominated diphenyl ethers (PBDEs), tetrabromobisphenol A bis 2,3-dibromopropylether (TBBPA-bis), tetrachlorobisphenol A (TCBPA), tetrabromobisphenol A (TBBPA) and hexabromocyclododecanes (HBCDs) was optimized by ultrahigh pressure liquid chromatography/tandem mass spectrometry (UPLC–MS/MS) operating in negative ion (NI) mode. Electrospray ionization (ESI), atmospheric pressure photoionization (APPI) and atmospheric pressure chemical ionization (APCI) sources were tested and for PBDEs APCI gave higher sensitivity than APPI while for TBBPA-bis APCI and APPI showed similar performance. ESI was the best option for TCBPA, TBBPA and HBCDs. Detection limits were between 20 and 59 fg for the compounds analyzed by ESI, 0.10 and 0.72 pg for PBDEs and 6 pg for TBBPA-bis. The matrix effect of sewage sludge extract was also tested showing negligible ion suppression for APCI and an increase of the background level of all investigated pollutants leading to a worsening of the limits of quantification by a factor between 1.2 and 3.3. The UPLC-APCI/MS/MS method for PBDEs, after pressurized liquid extraction (PLE), was validated by comparison with the concentration values from the NIST 1944 standard reference material. The advantages of the methods include low detection limits, PBDE congeners specificity using selected multiple reaction monitoring (MRM) transitions, and the absence of thermal degradation of higher PBDE congeners, especially BDE-209. The methods were applied for the determination of the above reported flame retardants in sewage sludge in order to get more information about the degradation on PBDEs (in particular BDE-209) during municipal wastewater treatments.  相似文献   

13.
A novel, gas-tight API interface for gas chromatography–mass spectrometry was used to study the ionization mechanism in direct and dopant-assisted atmospheric pressure photoionization (APPI) and atmospheric pressure laser ionization (APLI). Eight analytes (ethylbenzene, bromobenzene, naphthalene, anthracene, benzaldehyde, pyridine, quinolone, and acridine) with varying ionization energies (IEs) and proton affinities (PAs), and four common APPI dopants (toluene, acetone, anisole, and chlorobenzene) were chosen. All the studied compounds were ionized by direct APPI, forming mainly molecular ions. Addition of dopants suppressed the signal of the analytes with IEs above the IE of the dopant. For compounds with suitable IEs or Pas, the dopants increased the ionization efficiency as the analytes could be ionized through dopant-mediated gas-phase reactions, such as charge exchange, proton transfer, and other rather unexpected reactions, such as formation of [M?+?77]+ in the presence of chlorobenzene. Experiments with deuterated toluene as the dopant verified that in case of proton transfer, the proton originated from the dopant instead of proton-bound solvent clusters, as in conventional open or non-tight APPI sources. In direct APLI using a 266 nm laser, a narrower range of compounds was ionized than in direct APPI, because of exceedingly high IEs or unfavorable two-photon absorption cross-sections. Introduction of dopants in the APLI system changed the ionization mechanism to similar dopant-mediated gas-phase reactions with the dopant as in APPI, which produced mainly ions of the same form as in APPI, and ionized a wider range of analytes than direct APLI. Graphical Abstract
?  相似文献   

14.
Various carotenoids were analyzed by ultra-high-pressure liquid chromatography with tandem mass spectrometry detection (UHPLC-MS/MS). Three different techniques to ionize the carotenoids were compared: electrospray ionization (ESI), atmospheric pressure chemical ionization (APCI) and atmospheric pressure photoionization (APPI). For all of the carotenoids tested, it was possible to obtain characteristic transitions for their unequivocal identification using each ionization technique. APCI was shown to be a more powerful technique to ionize the carotenoids than ESI or APPI. Transitions to differentiate carotenoids that coelute were determined to distinguish antheraxanthin from astaxanthin and lutein from zeaxanthin. In addition, four dopants were evaluated to improve ionization and enhance the carotenoid signal strength in APPI. These dopants were acetone, toluene, anisole, and chlorobenzene. Carotenoids improved their response in almost all cases when a dopant was used. The use of dopants allowed the enhancement of the carotenoid signals strength up to 178-fold.  相似文献   

15.
Ion suppression is a well-known phenomenon in electrospray ionization (ESI) mass spectrometry. These suppression effects have been shown to adversely affect the accuracy and precision of quantitative bioanalytical methods using ion spray. Such suppression effects have not been as well defined in atmospheric pressure chemical ionization (APCI) and there is some debate whether these effects actually occur in the ionization process using APCI. Here an example is described where clear ion suppression was observed during studies on a model compound and three metabolites using APCI liquid chromatography/tandem mass spectrometry (LC/MS/MS).  相似文献   

16.
A fast and robust high-throughput ultra-performance liquid chromatography/time-of-flight mass spectrometry (UPLC–TOF MS) profiling method was developed and successfully applied to discriminate a total of 78 Bacillus cereus strains into no/low, medium and high producers of the emetic toxin cereulide. The data obtained by UPLC–TOF MS profiling were confirmed by absolute quantitation of cereulide in selected samples by means of high-performance liquid chromatography with tandem mass spectrometry (HPLC–MS/MS) and stable isotope dilution assay (SIDA). Interestingly, the B. cereus strains isolated from four vomit samples and five faeces samples from patients showing symptoms of intoxication were among the group of medium or high producers. Comparison of HEp-2 bioassay data with those determined by means of mass spectrometry showed differences, most likely because the HEp-2 bioassay is based on the toxic action of cereulide towards mitochondria of eukaryotic cells rather than on a direct measurement of the toxin. In conclusion, the UPLC–electrospray ionization (ESI)–TOF MS and the HPLC–ESI–MS/MS–SIDA analyses seem to be promising tools for the robust high-throughput analysis of cereulide in B. cereus cultures, foods and other biological samples.
Figure
Score plot (comp[1] vs. comp[2]) of UPLC‐TOF MS full scan analysis (50–1,300 Da) of 78 B. cereus strains with color‐coded signal intensity of the accurate mass of pseudo molecular ion of cereulide (m/z 1175.6608, [M+Na]+), from group 1 with the lowest up to group 5 with the highest signal intensity  相似文献   

17.
This paper presents a novel splitting method for liquid chromatography/mass spectrometry (LC/MS) application, which allows fast MS detection of LC-separated analytes and subsequent online analyte collection. In this approach, a PEEK capillary tube with a micro-orifice drilled on the tube side wall is used to connect with LC column. A small portion of LC eluent emerging from the orifice can be directly ionized by desorption electrospray ionization (DESI) with negligible time delay (6~10 ms) while the remaining analytes exiting the tube outlet can be collected. The DESI-MS analysis of eluted compounds shows narrow peaks and high sensitivity because of the extremely small dead volume of the orifice used for LC eluent splitting (as low as 4 nL) and the freedom to choose favorable DESI spray solvent. In addition, online derivatization using reactive DESI is possible for supercharging proteins and for enhancing their signals without introducing extra dead volume. Unlike UV detector used in traditional preparative LC experiments, this method is applicable to compounds without chromophores (e.g., saccharides) due to the use of MS detector. Furthermore, this splitting method well suits monolithic column-based ultra-fast LC separation at a high elution flow rate of 4 mL/min.
Figure
?  相似文献   

18.
The most widely used ionization techniques in liquid chromatography-mass spectrometry (LC-MS) are electrospray ionization (ESI), atmospheric pressure chemical ionization (APCI) and atmospheric pressure photoionization (APPI). All three provide user friendly coupling of LC to MS. Achieving optimal LC-MS conditions is not always easy, however, owing to the complexity of ionization processes and the many parameters affecting mass spectrometric sensitivity and chromatographic performance. The selection of eluent composition requires particular attention since a solvent that is optimal for analyte ionization often does not provide acceptable retention and resolution in LC. Compromises must then be made between ionization and chromatographic separation efficiencies. The review presents an overview of studies concerning the effect of eluent composition on the ionization efficiency of ESI, APCI and APPI in LC-MS. Solvent characteristics are discussed in the light of ionization theories, and selected analytical applications are described. The aim is to provide practical background information for the development and optimization of LC-MS methods.  相似文献   

19.
The performance of the atmospheric pressure photoionization (APPI) technique was evaluated against five sets of standards and drug-like compounds and compared to atmospheric pressure chemical ionization (APCI) and electrospray ionization (ESI). The APPI technique was first used to analyze a set of 86 drug standards with diverse structures and polarities with a 100% detection rate. More detailed studies were then performed for another three sets of both drug standards and proprietary drug candidates. All 60 test compounds in these three sets were detected by APPI with an overall higher ionization efficiency than either APCI or ESI. Most of the non-polar compounds in these three sets were not ionized by APCI or ESI. Analysis of a final set of 201 Wyeth proprietary drug candidates by APPI, APCI and ESI provided an additional comparison of the ionization techniques. The detection rates in positive ion mode were 94% for APPI, 84% for APCI, and 84% for ESI. Combining positive and negative ion mode detection, APPI detected 98% of the compounds, while APCI and ESI detected 91%, respectively. This analysis shows that APPI is a valuable tool for day-to-day usage in a pharmaceutical company setting because it is able to successfully ionize more compounds, with greater structural diversity, than the other two ionization techniques. Consequently, APPI could be considered a more universal ionization method, and therefore has great potential in high-throughput drug discovery especially for open access liquid chromatography/mass spectrometry (LC/MS) applications.  相似文献   

20.
Mass defect is the difference between the nominal and exact mass of a chemical element or compound. An intrinsic property of polyhalogenated molecules is a uniquely negative mass defect, which readily distinguishes halogenated from non-halogenated compounds in a complex mass spectrum and can be visualized by constructing a mass defect plot. This study demonstrates the utility of the mass defect plot as a powerful tool to screen gas-chromatography (ultra)high-resolution mass spectrometry data for potentially toxic and bioaccumulative halogenated compounds in a Lake Ontario lake trout, an apex species in the Great Lakes environment. Our results indicate that the sample is contaminated with polychlorinated biphenyls, terphenyls, diphenylethers, as well as other chlorinated pesticides and flame retardants that are regulated and routinely analyzed by traditional target analyses. However, the mass defect plot also displays peaks which could be traced to the presence of as yet undiscovered contaminants. These include chlorinated polycyclic aromatic hydrocarbons as well as mixed halogenated analogues of the flame retardant Dechlorane 604. The identity of the latter class of compounds is supported by experiments with genuine standards.
Fig
The mass defect plot provides an informative picture of the halogenated contaminants in a sample of Lake Ontario lake trout.  相似文献   