共查询到20条相似文献,搜索用时 51 毫秒
1.
Juliana de L. Castro Maria Elvira P. Martucci Henrique M.G. Pereira Valria P. de Sousa 《Journal of mass spectrometry : JMS》2020,55(10)
Dermorphin is a peptide with analgesic actions similar to morphine, but with greater effect and less potential to cause tolerance. The use of dermorphin has been documented in race horses, and its use in humans has already been reported. Considering the potential advantages from the use of dermorphin over morphine, a method to monitor it, and its main metabolite dermorphin (1‐4) in humans becomes necessary for doping control. Here, we present two orthogonal methods for this purpose: a high‐throughput liquid chromatography coupled to high‐resolution mass spectrometry (HRMS) as an initial testing procedure and liquid chromatography–tandem mass spectrometry (MS/MS) in the selected reaction monitoring (SRM) acquisition mode for a confirmation procedure. For urine samples, pretreatment through a mixed‐mode weak cation‐exchange solid‐phase extraction emerged as an effective approach to extract peptides from the biological sample. For the HRMS analysis, a full‐MS scan acquisition mode was selected to detect the exact masses of dermorphin and dermorphin (1‐4) at m/z 803.37226 and 457.20816, respectively. The SRM method used in the MS/MS confirmation protocol presented high specificity and sensitivity. The selected product ions for dermorphin were 602.2, 202.1 and 574.3 and for dermorphin (1‐4) were 207.1, 223.1, and 235.1. Both methods were evaluated for specificity, repeatability, carryover, matrix effects, and recovery. No carryover and matrix effects were detected. The limit of detection for initial testing procedure and the limit of identification for confirmation procedure was 2.5 ng/ml. Also, specificity and robustness were acceptable for the application. Together, the developed methods proved to be efficient for the analysis of dermorphin and metabolite for human doping control purpose. 相似文献
2.
固相萃取-高效液相色谱-串联质谱法同时测定尿液中的4种巯基尿酸 总被引:1,自引:0,他引:1
建立了固相萃取-高效液相色谱-串联质谱(HPLC-MS/MS)同时检测人体尿液中N-乙酰基-S-(3,4-二羟基丁基)-L-半胱氨酸(DHBMA)、N-乙酰基-S-(3-羟基丙基)半胱氨酸(3-HPMA)、N-乙酰基-S-(2-氰乙基)-L-2-氨基-3-巯基羧酸(CEMA)和苯巯基尿酸(SPMA)的检测方法。冰冻的人体24 h尿液在室温下解冻,混合均匀后离心过滤,经C18固相萃取小柱净化富集后在多反应监测模式下采用HPLC-MS/MS进行定量分析。在3个添加水平下,尿液中DHBMA、3-HPMA、CEMA和SPMA的加标回收率分别为105.6%~124.4%、102.7%~106.5%、103.2%~103.9%和101.7%~104.3%,相对标准偏差为2.6%~7.7%。以不低于3倍的信噪比估算DHBMA、3-HPMA、CEMA和SPMA的检出限分别为0.062、0.031、0.020和0.003 μg/L。应用该方法检测了37例吸烟和非吸烟者的24 h尿液样本,结果发现吸烟者尿液中3-HPMA、SPMA和CEMA的平均含量比非吸烟者高3到6倍。 相似文献
3.
Simultaneous determination of benzene,toluene, ethylbenzene,and xylene metabolites in human urine using electromembrane extraction combined with liquid chromatography and tandem mass spectrometry 下载免费PDF全文
Joon Hyuk Suh Hye Yeon Lee Unyong Kim Han Young Eom Junghyun Kim Hyun‐Deok Cho Sang Beom Han 《Journal of separation science》2015,38(24):4276-4285
For the first time, electromembrane extraction combined with liquid chromatography and tandem mass spectrometry was applied for the determination of urinary benzene, toluene, ethylbenzene, and xylene metabolites. S‐Phenylmercapturic acid, hippuric acid, phenylglyoxylic acid, and methylhippuric acid isomers were extracted from human urine through a supported liquid membrane consisting of 1‐octanol into an alkaline acceptor solution filling the inside of a hollow fiber by application of an electric field. Various extraction factors were investigated and optimized using response surface methodology, the statistical method. The optimum conditions were established to be 300 V applied voltage, 15 min extraction time, 1500 rpm stirring speed, and 5 mM ammonium acetate (pH 10.2) acceptor solution. The method was validated with respect to selectivity, linearity, accuracy, precision, limit of detection, limit of quantification, recovery, and reproducibility. The results showed good linearity (r2 > 0.995), precision, and accuracy. The extract recoveries were 52.8–79.0%. Finally, we applied this method to real samples and successfully measured benzene, toluene, ethylbenzene, and xylene metabolites. 相似文献
4.
Hon Kit Lee Yan Ping Heidi Iu Chi Chung Shek Helene Bendstrup Klinke 《Analytica chimica acta》2009,649(1):80-719
Withdrawal of the support for the REMEDi HS drug profiling system has necessitated its replacement within our laboratories with an alternative broad toxicological screening technique. To this end, a novel method, based on ultra-performance liquid chromatography (UPLC) and time-of-flight (TOF) mass spectrometry, was developed for the routine analysis of urine samples. Identification was achieved by comparison of acquired data to libraries containing more than 300 common drugs and metabolites, and was based on a combination of retention time, exact mass and fragmentation patterns. Validation data for the method is presented and comprised an evaluation of the following parameters: precision; transferability of the methodology between the six collaborating laboratories; specificity; extraction recovery and stability of processed samples; matrix effects and sensitivity.This paper presents the benefits of supplementary fragmentation data with particular regard to increasing specificity and confidence of identification and its usefulness with overdosed samples. The utility of the method was assessed by the parallel analysis of 30 authentic urine samples using the REMEDi HS and UPLC-TOF. The latter provided enhanced detection, leading to the identification of twice as many drugs. Furthermore it did not miss any compounds that were identified by REMEDi HS. The UPLC-TOF findings were further verified by a combination of data from three other conventional screening techniques, i.e., GC-MS, HPLC-DAD and UPLC-MS/MS. 相似文献
5.
Dapeng Liang Wenjie Liu Rabia Raza Yu Bai Huwei Liu 《Journal of separation science》2019,42(1):330-341
Pesticides, widely applied in agriculture, can produce a variety of transformation products and their continuous use causes deleterious effects to ecosystem. Efficient and sensitive analytical techniques for enrichment and analysis of pesticides samples are highly required. Compared with other extraction methods, solid‐phase micro extraction is a solvent free, cost effective, robust, versatile, and high throughput sample preparation technique, especially for the analysis of pesticides from complicated matrices. Coupling of solid‐phase micro extraction with gas chromatography and mass spectrometry and liquid chromatography–mass spectrometry has been extensively applied in pesticide analysis. On the other hand, in recent years, combination of fast separation using solid‐phase micro extraction and rapid detection using ambient mass spectrometry is providing highly efficient pesticide screening. This article summarizes the applications of solid‐phase micro extraction coupled to mass spectrometry for pesticides analysis. 相似文献
6.
Summary A method for the selective quantification of doxycycline in human plasma and urine has been developed using HPLC with UV-detection
at 350 nm. Analyte and internal standard were extracted from plasma by extraction columns filled with octadecylsilica. Urines
were only mixed with diluted acid prio to injection. The influence of pH on peak shapes is discussed as well as comparative
investigations on selectivity and peak symmetry on commerical octadecylsilica. The method was successfully applied to the
samples of a clinical study with an oral single dose of 100 mg. Precision and accuracydata of the assay and calculated pharmacokinetic
parameters are presented. 相似文献
7.
Summary A method for the sensitive detection of isopropyl substituted β-blocking agents in human urine is presented. The sample preparation
step involves enzymatic hydrolysis, solid phase extraction and derivatisation withN-methyl-N-trimethylsilyl-trifluoroacetamide. The instrumental analysis was performed using gas chromatography-mass spectrometry with
an ion trap mass spectromeler. The mass spectrometer was operated in the scan as well as in the MS-MS mode. 相似文献
8.
Peschka M Petrovic M Knepper TP Barceló D 《Analytical and bioanalytical chemistry》2007,388(5-6):1227-1234
The transformation products 2-(isopropylcarbamoyl)phenylsulfamic acid and 2-(1-hydroxypropane-2-yl)-1,2-dihydroindazol-3-one
could be determined during the photolysis of the herbicide bentazone. Degradation experiments were carried out with different
types of water in a natural sunlight simulating system. Besides the anticipated hydroxylated bentazone, the second transformation
product was identified by means of exact mass measurement using ultra-performance liquid chromatography/quadrupole time-of-flight
mass spectrometry (UPLC/QqToF MS). Both phototransformation products occurred in all water types tested. The required irradiation
time was matrix dependent. 2-(Isopropylcarbamoyl)phenylsulfamic acid was detected in a drainage channel in the Ebro river
delta (Catalonia, Spain). 相似文献
9.
《Journal of separation science》2017,40(21):4234-4245
An easy‐to‐handle magnetic dispersive solid‐phase extraction procedure was developed for preconcentration and extraction of cocaine and cocaine metabolites in human urine. Divinyl benzene and vinyl pyrrolidone functionalized silanized Fe3O4 nanoparticles were synthesized and used as adsorbents in this procedure. Scanning electron microscopy, vibrating sample magnetometry, and infrared spectroscopy were employed to characterize the modified adsorbents. A high‐performance liquid chromatography with mass spectrometry method for determination of cocaine and its metabolites in human urine sample has been developed with pretreatment of the samples by magnetic dispersive solid‐phase extraction. The obtained results demonstrated the higher extraction capacity of the prepared nanoparticles with recoveries between 75.1 to 105.7% and correlation coefficients higher than 0.9971. The limits of detection for the cocaine and cocaine metabolites were 0.09–1.10 ng/mL. The proposed magnetic dispersive solid‐phase extraction method provided a rapid, environmentally friendly and magnetic stuff recyclable approach and it was confirmed that the prepared adsorbents material was a kind of highly effective extraction materials for the trace cocaine and cocaine metabolites analyses in human urine. 相似文献
10.
Tetracyclines abuse has frequently occurred in aquaculture against bacteria, rickettsiae, spirochetes, and mycoplasmas. In this study, a high‐throughput sample preparation method was developed using 96‐well plate solid‐phase extraction (p‐SPE) and the extract was analyzed by ultra‐performance liquid chromatography tandem mass spectrometry (UPLC‐MS/MS). The experimental conditions were optimized such that the pH is 4, the eluting solvent is methanol (2 mL), and the sorbent is hydrophilic‐lipophilic balance (HLB) microsphere. The whole protocol was validated, and it showed that the tetracyclines were linear with correlation coefficients ≥ 0.9990, precision and accuracy (RSD%) in 3.9–6.1%, and mean recoveries of 88.6–103.6%. To exhibit the potential of 96‐well p‐SPE as a routine tool for inspection and quarantine, fresh aquatic samples were tested, and among which positive samples were observed. This method was demonstrated to be promising for the purification and enrichment of tetracyclines with reduced time and labor, and indeed practically and particularly suitable for widespread tetracyclines analysis. 相似文献
11.
A general screening method for doping agents in human urine by solid phase extraction and liquid chromatography/time-of-flight mass spectrometry 总被引:1,自引:0,他引:1
A general screening method based on solid phase extraction (SPE) and liquid chromatography/time-of-flight mass spectrometry (LC/TOFMS) was developed and investigated with 124 different doping agents, including stimulants, -blockers, narcotics, -adrenergic agonists, agents with anti-estrogenic activity, diuretics and cannabinoids. Mixed mode cation exchange/C8 cartridges were applied to SPE, and chromatography was based on gradient elution on a C18 column. Ionization of the analytes was achieved with electrospray ionization in the positive mode. Identification by LC/TOFMS was based on retention time, accurate mass and isotopic pattern. Validation of the method consisted of analysis of specificity, analytical recovery, limit of detection and repeatability. The minimum required performance limit (MRPL), established by World Anti-Doping Agency (WADA), was attained to 97 doping agents. The extraction recoveries varied between 33 and 98% and the median was 58%. Mass accuracy was always better than 5 ppm, corresponding to a maximum mass error of 0.7 mDa. The repeatability of the method for spiked urine samples, expressed as median of relative standard deviations (RSD%) at concentrations of MRPL and 10 times MRPL, were 14% and 9%, respectively. The suitability of the LC/TOFMS method for doping control was demonstrated with authentic urine samples. 相似文献
12.
An ultra-performance liquid chromatography/time-of-flight mass spectrometry (UPLC/TOF-MS)-based metabolomic approach was developed to characterize the metabolic profile associated with isoproterenol (ISO)-induced myocardial infarction (MI). Analysis of the serum samples revealed distinct changes in the biochemical patterns of ISO-induced rats. A multivariate statistical method, supervised partial least squares-discriminant analysis (PLS-DA), was then used for screening of potential biomarkers. As a result, 13 lipid biomarkers, including lysophosphatidylcholines (Lyso-PCs) and fatty acids were identified by the accurate mass measurement of TOF-MS. The relationship between abnormal lipid metabolism and the formation of MI were also studied. This work demonstrates the utility of UPLC/TOF-MS-based metabolic profiling combined with multivariate analysis as a powerful tool to further investigate the pathogenesis of cardiovascular diseases. 相似文献
13.
For the detection of anabolic steroid residues in bovine urine, a highly sensitive liquid chromatographic/electrospray ionization tandem mass spectrometric (LC/ESI-MS/MS) method was developed using both positive and negative ionization. For four compounds the ESI mode was not sensitive enough and gas chromatographic/mass spectrometric GC/MS detection was therefore still necessary as a complementary method. The sample clean-up consisted of solid-phase extraction (SPE) on a C(18) column followed by enzymatic hydrolysis and a second solid-phase extraction on a combination of a C(18) and a NH(2) column. After this last SPE clean-up, the eluate was split into two equal aliquots. One aliquot was further purified and after derivatization used for GC/MS analysis. The other aliquot was analyzed with LC/MS/MS in both ESI+ and ESI- modes. The method was validated according to the European Commission Decision 2002/657/EC. Decision limits (CCalpha) were between 0.16 and 1 ng ml(-1) for the compounds detected with the LC/MS/MS method. The developed method is used in routine analysis in our laboratory. 相似文献
14.
Cazorla-Reyes R Fernández-Moreno JL Romero-González R Frenich AG Vidal JL 《Talanta》2011,85(1):183-196
A new multiresidue method has been developed and validated for the simultaneous extraction of more than two hundred pesticides, including non-polar and polar pesticides (carbamates, organochlorine, organophosphorous, pyrethroids, herbicides and insecticides) in urine at trace levels by gas and ultra high pressure liquid chromatography coupled to ion trap and triple quadrupole mass spectrometry, respectively (GC-IT-MS/MS, UHPLC-QqQ-MS/MS). Non-polar and polar pesticides were simultaneously extracted from urine samples by a simple and fast solid phase extraction (SPE) procedure using C18 cartridges as sorbent, and dichloromethane as elution solvent. Recovery was in the range of 60-120%. Precision values expressed as relative standard deviation (RSD) were lower than 25%. Identification and confirmation of the compounds were performed by the use of retention time windows, comparison of spectra (GC-amenable compounds) or the estimation of the ion ratio (LC-amenable compounds). For GC-amenable pesticides, limits of detection (LODs) ranged from 0.001 to 0.436 μg L−1 and limits of quantification (LOQs) from 0.003 to 1.452 μg L−1. For LC-amenable pesticides, LODs ranged from 0.003 to 1.048 μg L−1 and LOQs ranged from 0.011 to 3.494 μg L−1. Finally, the optimized method was applied to the analysis of fourteen real samples of infants from agricultural population. Some pesticides such as methoxyfenozide, tebufenozide, piperonyl butoxide and propoxur were found at concentrations ranged from 1.61 to 24.4 μg L−1, whereas methiocarb sulfoxide was detected at trace levels in two samples. 相似文献
15.
Jianshuang Wang Michael Van Parys Lin Pan Yuan Chen Dorothy Cheung Janine McKnight Dennis Milanowski Xiao Ding Brian Dean 《Biomedical chromatography : BMC》2019,33(4)
A specific and robust LC–MS/MS method was developed and validated for the quantitative determination of GDC‐3280 in human plasma and urine. The nonspecific binding associated with urine samples was overcome by the addition of CHAPS. The sample volume was 25 μL for either matrix, and supported liquid extraction was employed for analyte extraction. d6‐GDC‐3280 was used as the internal standard. Linear standard curves (R2 > 0.9956) were established from 5.00 to 5000 ng/mL in both matrices with quantitation extended to 50,000 ng/mL through dilution. In plasma matrix, the precision (RSD) ranged from 1.5 to 9.9% (intra‐run) and from 2.4 to 7.2% (inter‐run); the accuracy (RE) ranged from 96.1 to 107% (intra‐run) and from 96.7 to 104% (inter‐run). Similarly, in urine the precision was 1.5–6.2% (intra‐run) and 1.9–6.1% (inter‐run); the accuracy was 83.1–99.3% (intra‐run) and 87.1–98.3% (inter‐run). Good recovery (>94%) and negligible matrix effect were achieved in both matrices. Long‐term matrix stability was established for at least 703 days in plasma and 477 days in urine. Bench‐top stability of 25 h and five freeze–thaw cycles were also confirmed in both matrices. The method was successfully implemented in GDC‐3280's first‐in‐human trial for assessing its pharmacokinetic profiles. 相似文献
16.
超高效液相色谱-四极杆-飞行时间质谱检测和鉴定猪尿中氯丙那林的主要代谢产物 总被引:1,自引:0,他引:1
采用超高效液相色谱-四极杆-飞行时间质谱(UPLC/Q-TOF MS)检测和鉴定了猪尿中氯丙那林的主要代谢产物,并讨论了氯丙那林在猪体内的主要代谢途径。按10 mg/kg(b. w.)的剂量口服灌食氯丙那林,分别采集给药前及给药后的猪尿液样品。采用UPLC/Q-TOF MS对样品进行分析,并应用质量亏损过滤和离子色谱峰提取等数据处理技术,在给药后24 h内的猪尿中检测和鉴定了9种氯丙那林的代谢产物,其中,Ⅰ相代谢产物2种,Ⅱ相代谢产物7种。然后,根据氯丙那林原形和代谢产物的碎片离子特征,对代谢产物的结构进行鉴定。最后,根据所鉴定的代谢产物,推测氯丙那林在猪体内的代谢途径包括苯环羟基化、β -羟基和仲氨基的葡萄糖醛酸轭合、羟基化后的葡萄糖醛酸和硫酸轭合等。研究结果表明,羟基化氯丙那林及其轭合产物的相对含量大于60%,明显高于氯丙那林原形及其轭合产物,是尿液中的主要代谢产物。本研究将为确定氯丙那林在动物体内的残留标示物及加强对氯丙那林非法使用的监控提供科学依据。 相似文献
17.
We developed an analytical method for a simple, sensitive and simultaneous determination of oxidized nucleosides in urine using column-switching liquid chromatography-electrospray/tandem mass spectrometry (LC-ESI/MS/MS). We connected two columns through a six-way switching valve and effectively separated nucleosides in the urine from the interference by column-switching liquid chromatography. We monitored separated nucleosides using positive ionization tandem mass spectrometry in selective reaction monitoring (SRM) mode. The calibration ranges of nucleosides were 0.2-100 nmol/mL. The linearity of the method was 0.994-0.999, and the limits-of-detection (LOD) at a signal-to-noise (S/N) ratio of 3 were 0.1-0.2 nmol/mL. The coefficients of variation were in the range 2.28-11.74% for within-day variation and 4.36-11.15% for day-to-day variation, respectively. To explore the relationship between breast cancer and the nucleosides level in human urine, we measured the concentrations of nucleosides in female patients with breast cancer (n = 30) and in normal female subjects (n = 30). The concentration of nucleosides was significantly increased in patients with breast cancer when compared with the normal controls (1-methyladenosine; p < 0.005, N(2),N(2)-dimethylguanosine; p < 0.01, 5-hydroxymethyl-2'-deoxyuridine; p < 0.001, 8-hydroxy-2-deoxyguanosine; p < 0.001). Therefore, the elevated levels of nucleosides could be used as an important biomarker for breast-cancer research. 相似文献
18.
Weizhu Chen Yiping Zhang Hua Fang Hui Chen Jianlin He Ruizao Yi Zhuan Hong 《Biomedical chromatography : BMC》2020,34(9):e4900
Tetrodotoxin (TTX) exhibits the therapeutic potential in blocking pain and in low doses can safely relieve severe pain. The urinary excretion profiles of TTX in humans have not been reported due to the extremely low lethal dose. In this study, a rapid and specific method based on protein precipitation coupled to liquid chromatography tandem mass spectrometry was developed to determine the level of TTX in human urine samples. 11-Deoxytetrodotoxin was used as an internal standard (IS). Multiple reaction monitoring mode was used for quantification using target fragment ions m/z 320.0 → 162.1 for TTX and m/z 304.0 → 176.0 for 11-deoxyTTX. The separation of analytes was achieved on a hydrophilic interaction liquid chromatography column (250 × 4.6 mm, 5.0 μm). The mobile phase consisted of 5 mM ammonium formate in water (pH = 4.50) and 5 mM ammonium formate in acetonitrile (pH = 4.50). The flow rate was set at 0.80 mL/min in a gradient condition. Calibration plots were linear throughout the range 0.986–98.6 ng/mL of TTX in human urine. The intra-assay accuracies and precisions were within the acceptable range. The method was successfully applied to a urinary excretion study after intravenous administration of TTX to healthy volunteers. The developed method will be helpful for future pharmacological studies of TTX. 相似文献
19.
固相萃取-超高压液相色谱-串联质谱同时分析环境水样中四环素类和喹诺酮类抗生素 总被引:5,自引:0,他引:5
应用固相萃取及超高压液相色谱-质谱联用技术,建立了环境水样中4种四环素类和6种喹诺酮类抗生素的同时分析方法。样品经HLB固相萃取柱富集、净化后用甲醇洗脱,以超高压液相色谱-串联质谱仪多反应监测(MRM)离子模式定性、定量分析。以河水和海水为基质,卡巴氧为替代物进行回收率评价,4种四环素类抗生素在加标质量浓度分别为20.0 ng/L和100.0 ng/L时的回收率为94.0%~117.0%,相对标准偏差为2.0%~9.7%(n=4),方法的检出限均为20.0 ng/L;6种喹诺酮类抗生素在加标质量浓度分别为5.0 ng/L和20.0 ng/L时的回收率为63.6%~93.9%,相对标准偏差为1.6%~8.1%(n=4),方法的检出限为0.4 ng/L。结果表明,所建立的方法可成功地应用于近岸海域表层环境水样中目标抗生素残留的分析。 相似文献
20.
超高效液相色谱-三重四极杆质谱法测定人尿中9种邻苯二甲酸酯代谢物 总被引:1,自引:0,他引:1
建立了人尿中9种邻苯二甲酸酯(PAE)代谢物的超高效液相色谱-三重四极杆质谱(UPLC-MS/MS)测定方法。2 mL尿液样本酶解2 h后,经强阴离子固相萃取净化处理;选用Waters ACQUITY UPLC BEH Phenyl色谱柱(100 mm×2.1 mm,1.7 μ m),以0.1%(体积分数)乙酸乙腈和0.1%(体积分数)乙酸水溶液为流动相进行梯度洗脱;在负离子电喷雾多反应监测模式(MRM)下测定9种PAE代谢物含量。8种PAE代谢物在0.39~200 μ g/L范围内、1种PAE代谢物在1.17~600 μ g/L范围内线性关系良好,相关系数均大于0.995。方法检出限为0.06~0.85 μ g/L,定量限为0.20~2.80 μ g/L。3个加标水平的加标回收率为84.1%~122%,精密度为4.5%~14.3%;日内精密度不高于9.3%,日间精密度不高于10.1%;基质效应和稳定性符合分析要求。应用该方法测定50份人尿液样本,邻苯二甲酸单环已酯(MCHP)和邻苯二甲酸单苄酯(MBZP)的检出率分别为0和44.0%,其余7种PAE代谢物的检出率为100%。该方法操作简单、定量准确、稳定性好,适用于人尿中9种PAE代谢物的定量分析。 相似文献