首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A rapid and simple method for the extraction and preconcentration of N-methylcarbamates (NMCs) (carbofuran, carbaryl and promecarb) in water samples using dispersive liquid–liquid microextraction (DLLME) using chemometrics was developed. Influence variables such as volume of extracting (CHCl3) and dispersing solvents (ACN), pH and ionic strength, extraction time and centrifugation time and speed were screened in a 27–4 Plackett–Burman design was investigated. The significant variables were optimized by using a central composite design (CCD) combined with desirability function (DF). At optimum conditions values of variables set as 126 μL chloroform, 1.5 mL acetonitrile, 1 min extraction time, 10 min centrifugation at 4000 rpm min−1, natural pH, 4.7% (w/v) NaCl, the separation was reached in less than 14 min using a C18 column and an isocratic binary mobile phase (acetonitrile: water (50:50, v/v)) with flow rate of 1.0 mL min−1. At optimum conditions method has linear response over 0.001–10 μg mL−1 with detection limit between 0.0001 and 0.0005 μg mL−1 with relative standard deviations (RSDs) in the range 2.18–5.06% (n = 6).  相似文献   

2.
Hydrophobic silver and titanium (IV) oxide nanoparticles (commercial Ag and TiO2 NPs with average particle sizes of 17 and 19 nm, respectively) were quantitatively transferred into organic phase in natural water samples. Five NP surface modification and solvent extraction agents (reagents) types, mercaptocarboxylic acid, alkylamine, mediator solvent, extraction solvent, and surfactant, were investigated and optimized with three-level orthogonal array design (OAD), an OA27 (313) matrix. The most favorable reagents and experimental conditions were then examined. The best extraction efficiencies of 78.6 and 73.7% were obtained for 1 mg L−1 citrate-stabilized Ag and TiO2 NPs, respectively, with 0.5 mM of 11-mercaptoundecanoic acid, 1.5 mM of octadecylamine, 1 mL of methanol, 150 μL of cyclohexane, 0.05 mM of tetra-n-octylammonium bromide, pH = 8.0, adsorption time of 2 h, sonication time of 3 min, and centrifugation time of 10 min. Enrichment factors were 97 and 83, for Ag and TiO2 NPs, respectively. The optimum extraction conditions were successfully applied to genuine water samples at spiking levels of 2–100 μg L−1 of Ag and TiO2 NPs. The relative recoveries of (69.0–85.1)% and (61.5–78.5)% were obtained for Ag and TiO2 NPs, respectively. The extracted surface-modified NPs were characterized with transmission electron microscopy, selected area electron diffraction, energy-dispersive X-ray, ultraviolet–visible, and Fourier transform infrared spectroscopic techniques. Based on the results, efficient ligand exchange and acid–base pair formation were observed on the NP surface without significant change in its original properties. The organic phase was microwave digested, and analyzed with inductively coupled plasma (ICP) optical emission spectroscopy and ICP mass spectrometry (ICP-MS). Detection limits of ICP-MS analyses of Ag and TiO2 NPs were 0.02 and 0.07 μg L−1, respectively.  相似文献   

3.
Ultrasound-assisted emulsification-microextraction (USAEME) procedure was developed for the determination of selected polychlorinated biphenyls (PCBs) in 10 mL of water samples by gas chromatography-mass-selective detection. After determination of the most suitable solvent and extraction time, several other parameters including solvent volume, centrifugation time and ionic strength of the sample were optimized using a 23 factorial experimental design. The optimized USAEME procedure used 200 μL of chloroform as extraction solvent, 10 min of extraction with no ionic strength adjustment at 25 °C and 5 min of centrifugation at 4000 rpm. The limits of detection ranged from 14 ng L−1 (for PCB153) to 30 ng L−1 (for PCB101). Recoveries of PCBs from fortified distilled water are over 80% for three different fortification levels between 0.1 and 5 μg L−1 and relative standard deviations of the recoveries are below 10%. The performance of the proposed method was compared with those involving traditional liquid-liquid extraction (LLE) and solid phase extraction (SPE) on the real water samples (i.e., tap and well water as well as domestic and industrial wastewaters, etc.) and comparable efficiencies were obtained. The proposed USAEME procedure has been demonstrated to be viable, simple, rapid and easy to use for residue analysis of PCBs in water samples.  相似文献   

4.
A rapid and simple method for the determination of two phthalates and five polycyclic musks in water samples using dispersive liquid-liquid microextraction (DLLME) mated to chemometrics and coupled to GC-MS was developed. Volume of extraction (CCl4) and disperser solvent (MeOH), pH, ionic strength, extraction time, centrifugation time as well as centrifugation speed were optimized in a 27-4 Plackett-Burman design. The obtained significant factors were optimized by using a central composite design (CCD) and the quadratic model between the dependent and the independent variables was built. The optimum experimental conditions of the proposed method were: 250 μL carbon tetrachloride, 0.62 mL methanol, 7.5 min centrifugation time, natural pH containing 0% (w/v) NaCl, while keeping centrifugation speed fixed at 4000 rpm.The calculated calibration curves gave high-level linearity for all target analytes with correlation coefficients ranging between 0.9970 and 0.9992. The repeatability and reproducibility of the proposed method, expressed as relative standard deviation, varied between 2.6% to 9.7% and 5.7% to 12.2%, respectively. The obtained LOD values were in the range of 8-63 ng L−1.  相似文献   

5.
In this work, a headspace-solid-phase micro-extraction (HS-SPME) combined with gas chromatography–mass spectrometry (GC–MS) method for multielemental speciation of organometallic compounds of mercury, lead and tin in water samples was upgraded by the introduction of tandem mass spectrometry (MS/MS) as detection technique. The analytical method is based on the ethylation with NaBEt4 and simultaneous headspace-solid-phase micro-extraction of the derivative compounds followed by GC–MS/MS analysis. The main experimental parameters influencing the extraction efficiency such as derivatisation time, extraction time and extraction temperature were optimized. The overall optimum extraction conditions were the following: a 50 μm/30 μm divinyl-benzene/carboxen/polydimethylsiloxane (DVB/CAR/PDMS) SPME fibre, 150 min derivatisation time, 15 min extraction time, sample agitation at 250 rpm and 40 °C extraction temperature. The analytical characteristics of the HS-SPME method combined with GC–MS and GC–MS/MS were evaluated. The combination of both techniques HS-SPME and GC–MS/MS allowed to attain lower limits of detection (4–33 ng l−1) than those obtained by HS-SPME–GC–MS (17–45 ng l−1). The proposed method presented good linear regression coefficients (r2 > 0.9970) and repeatability (4.8–21.0%) for all the compounds under study. The accuracy of the method measured as the average percentage recovery of the compounds in spiked river water and seawater samples was higher than 80% for all the compounds studied, except for monobutyltin in the river water sample. A study of the uncertainty associated with the analytical results was also carried out.  相似文献   

6.
Saracoglu S  Soylak M  Elci L 《Talanta》2003,59(2):287-293
Multi-element determination of trace elements in urine and dialysis solutions by atomic absorption spectrometry has been investigated. Coprecipitation with samarium hydroxide was used for preconcentration of trace elements and elimination of matrix elements. To 10 ml of each sample was added 500 μl of 2 mg ml−1 samarium solutions; the pH was then adjusted to 12.2 in order to collect trace heavy metals on samarium hydroxide. The precipitate was separated by centrifugation and dissolved in 1 ml of 1 mol l−1 HNO3. Coprecipitation parameters and matrix effects are discussed. The precision, based on replicate analysis, is around 5% for the analytes, and recovery is quantitative, based on analysis of spiked samples and solutions including matrix components. The time required for the coprecipitation and determination was about 30 min.  相似文献   

7.
In this paper, bamboo charcoals were modified using Fe3O4 nanosheets for the first time. The composites, as a novel solid-phase microextraction (SPME) fiber coating, were used for the extraction of seven polybrominated diphenyl ethers (PBDEs) in environmental water samples. The extraction factors (stirring rate, extraction time, and ionic strength) and desorption factors (desorption time and desorption temperature) of the fibers were systematically investigated and optimized. Under optimum conditions, the linear range was 1–1000 ng L−1. Based on the ratio of chromatographic signal to base line noise (S N−1 = 3), the limits of detection (LODs) can reach 0.25–0.62 ng L−1. The novel method was successful in the analysis of PBDEs in real environmental water samples. The results indicate that bamboo charcoal/Fe3O4 as an SPME coating material coupled with gas chromatography–negative chemical ionization-mass spectrometry is an excellent method for the routine analysis of PBDEs at trace levels in environmental water samples.  相似文献   

8.
A new and fast equilibrium-based solvent microextraction technique termed vortex-assisted liquid-liquid microextraction (VALLME) has been developed and used for the trace analysis of octylphenol, nonylphenol and bisphenol-A in water and wastewater samples. According to VALLME, dispersion of microvolumes of a low density extractant organic solvent into the aqueous sample is achieved by using for the first time vortex mixing, a mild emulsification procedure. The fine droplets formed could extract target analytes towards equilibrium faster because of the shorter diffusion distance and larger specific surface area. Upon centrifugation the floating extractant acceptor phase restored its initial single microdrop shape and was used for high-performance liquid chromatographic analysis. Different experimental parameters were controlled and the optimum conditions found were: 50 μl of octanol as the extractant phase; 20 ml aqueous donor samples; a 2 min vortex extraction time with the vortex agitator set at a 2500 rpm rotational speed; centrifugation for 2 min at 3500 rpm; no ionic strength or pH adjustment. The calculated calibration curves gave high levels of linearity yielding correlation coefficients (r2) greater than 0.9935. The repeatability and reproducibility of the proposed method were found to be good and the limits of the detection were calculated in the low μg l−1 level ranging between 0.01 and 0.07 μg l−1. Matrix effects were determined by applying the proposed method to spiked tap, river water and treated municipal wastewater samples. The proposed method was finally applied to the determination of target pollutants in real wastewater effluent samples using the standard addition method.  相似文献   

9.
In the present work, a cloud point extraction (CPE) system has been proposed for determination of species de chromium in the natural water samples, Cr(III) and Cr(VI). The procedure was based on the reaction of Cr(III) with 1-(2-pyridilazo)-2-naphtol (PAN) in a surfactant solution (Triton X-114) yielding a hydrophobic complex, which then is entrapped “in situ” in the surfactant micelles. When the temperature of the system was higher than the cloud point of Triton X-114, the complex of Cr(III)-PAN entered the surfactant-rich phase and thus separation of the analyte from the matrix was achieved. Separation of the two phases was accomplished by centrifugation for 15 min at 2500 rpm. The Cr(VI) assay is based on its reduction to Cr(III) by ascorbic acid which subsequently reacts with PAN in a similar manner. The main factors affecting the cloud point extraction, such as complexation pH (7.7), buffer concentration (0.025 mol L− 1) and microwave irradiation time (10 min) were optimized by response surface methodology (RSM) using Box–Behnken design. Under the optimized conditions, the preconcentration system (50 mL sample) permitted an enrichment factor of 48, linear range of 2.5–80 μg L− 1, limit of detection and quantification of 0.7 and 2.5 μg L− 1, respectively, and the relative standard deviation (n = 10) of 2.0% for 50 μg L− 1 Cr(III) solution and (n = 10) 5.5% for 10 μg L− 1. The proposed procedure was applied to the speciation of chromium in river water samples. The procedure affords recoveries of 84–115% and a relative standard deviation lower than 4.2%. The analytical results of total chromium in the river water samples under study agreed well with those by electrothermal atomic absorption spectrometry (ET AAS). It is proved that the procedure can be successfully employed as an alternative to the commonly used preconcentration and speciation analytical techniques.  相似文献   

10.
A novel and efficient digestion method based on choline chloride–oxalic acid (ChCl–Ox) deep eutectic solvent (DES) was developed for flame atomic absorption spectrometry (FAAS) determination of Cu, Zn, and Fe in biological fish samples. Key parameters that influence analyte recovery were investigated and optimized, using the fish protein certified reference material (CRM, DORM-3) throughout the procedure. In this method, 100 mg of the sample was dissolved in ChCl–Ox (1:2, molar ratio) at 100 °C for 45 min. Then, 5.0 mL HNO3 (1.0 M) was added. After centrifugation, the supernatant solution was filtered, diluted to a known volume, and analyzed by FAAS. Under optimized conditions, an excellent agreement between the obtained results and the certified values was observed, using Student's t-test (P = 0.05); the extraction recovery of the all elements was greater than 95.3%. The proposed method was successfully applied to the determination of analytes in different tissues (muscle, liver, and gills) having a broad concentration range in a marine fish sample. The reproducibility of the method was validated by analyzing all samples by our method in a different laboratory, using inductively coupled plasma optical emission spectrometry (ICP-OES). For comparison, a conventional acid digestion (CAD) method was also used for the determination of analytes in all studied samples. The simplicity of the proposed experimental procedure, high extraction efficiency, short analysis time, lack of concentrated acids and oxidizing agents, and the use of safe and inexpensive components demonstrate the high potential of ChCl–Ox (1:2) for routine trace metal analysis in biological samples.  相似文献   

11.
Stir bar sorptive extraction (SBSE) and thermal desorption (TD)–gas chromatography–mass spectrometry (GC–MS) have been optimized for the determination of five organic booster biocides (Chlorothalonil, Dichlofluanid, Sea-Nine 211, Irgarol 1051 and TCMTB) in seawater samples. The parameters affecting the desorption and absorption steps were investigated using 10 mL seawater samples. The optimised conditions consisted of an addition of 0.2 g mL−1 KCl to the sample, which was extracted with 10 mm length, 0.5 mm film thickness stir bars coated with polydimethylsiloxane (PDMS), and stirred at 900 rpm for 90 min at room temperature (25 °C) in a vial. Desorption was carried out at 280 °C for 5 min under 50 mL min−1 of helium flow in the splitless mode while maintaining a cryotrapping temperature of 20 °C in the programmed-temperature vaporization (PTV) injector of the GC–MS system. Finally, the PTV injector was ramped to a temperature of 280 °C and the analytes were separated in the GC and detected by MS using the selected-ion monitoring (SIM) mode. The detection limits of booster biocides were found to be in the range of 0.005–0.9 μg L−1. The regression coefficients were higher than 0.999 for all analytes. The average recovery was higher than 72% (R.S.D.: 7–15%). All these figures of merit were established running samples in triplicate. This simple, accurate, sensitive and selective analytical method may be used for the determination of trace amounts of booster biocides in water samples from marinas.  相似文献   

12.
A novel derivatization-ultrasonic assisted-dispersive liquid–liquid microextraction (UA-DLLME) method for the simultaneous determination of 11 main carbohydrates in tobacco has been developed. The combined method involves pressurized liquid extraction (PLE), derivatization, and UA-DLLME, followed by the analysis of the main carbohydrates with a gas chromatography-flame ionization detector (GC-FID). First, the PLE conditions were optimized using a univariate approach. Then, the derivatization methods were properly compared and optimized. The aldononitrile acetate method combined with the O-methoxyoxime-trimethylsilyl method was used for derivatization. Finally, the critical variables affecting the UA-DLLME extraction efficiency were searched using fractional factorial design (FFD) and further optimized using Doehlert design (DD) of the response surface methodology. The optimum conditions were found to be 44 μL for CHCl3, 2.3 mL for H2O, 11% w/v for NaCl, 5 min for the extraction time and 5 min for the centrifugation time. Under the optimized experimental conditions, the detection limit of the method (LODs) and linear correlation coefficient were found to be in the range of 0.06–0.90 μg mL−1 and 0.9987–0.9999. The proposed method was successfully employed to analyze three flue-cured tobacco cultivars, among which the main carbohydrate concentrations were found to be very different.  相似文献   

13.
A new simultaneous derivatization and extraction method for the preconcentration of ammonia using new one-step headspace dynamic in-syringe liquid-phase microextraction with in situ derivatization was developed for the trace determination of ammonium in aqueous samples by liquid chromatography with fluorescence detection (LC–FLD). The acceptor phase (as derivatization reagent) containing o-phthaldehyde and sodium sulfite was held within a syringe barrel and immersed in the headspace of sample container. The gaseous ammonia from the alkalized aqueous sample formed a stable isoindole derivative with the acceptor phase inside the syringe barrel through the reciprocated movements of plunger. After derivatization-cum-extraction, the acceptor phase was directly injected into LC–FLD for analysis. Parameters affecting the ammonia evolution and the extraction/derivatization efficiency such as sample matrix, pH, temperature, sampling time, and the composition of derivatization reagent, reaction temperature, and frequency of reciprocated plunger, were studied thoroughly. Results indicated that the maximum extraction efficiency was obtained by using 100 μL derivatization reagent in a 1-mL gastight syringe under 8 reciprocated movements of plunger per min to extract ammonia evolved from a 20 mL alkalized aqueous solution at 70 °C (preheated 4 min) with 380 rpm stirring for 8 min. The detection was linear in the concentration range of 0.625–10 μM with the correlation coefficient of 0.9967 and detection limit of 0.33 μM (5.6 ng mL−1) based on S N−1 = 3. The method was applied successfully to determine ammonium in real water samples without any prior cleanup of the samples, and has been proved to be a simple, sensitive, efficient and cost-effective procedure for trace ammonium determination in aqueous samples.  相似文献   

14.
Ultrasonic back-extraction of Triton X-100 reverse micelles by a water/chloroform binary system and gas chromatography with flame ionization detection (GC-FID) was developed for extraction and determination of β-sitosterol and cholesterol in soybean and sunflower oil samples. After the homogenization of the oil samples with Triton X-100, an aliquot of 200 μL of methanol was added to the samples to form two phases. The clear Triton X-100 extract obtained by centrifugation was treated with a mixture of water (1000 μL) and chloroform (300 μL) for back-extraction of the analytes into the chloroform phase by ultrasonication. After centrifugation, the sedimented chloroform layer was withdrawn easily by a microsyringe and directly injected into the GC-FID system. The influence of several important parameters on the extraction efficiencies of the analytes was evaluated. Under optimized experimental conditions, the calibration graphs were linear in the range of 1.0–30.0 mg L−1 with coefficient of determination more than 0.994 for both analytes. The method detection limit values were in the range of 0.2–0.7 mg L−1. The lower limit of quantification values were in the range of 0.7–2.4 mg L−1. Intra-day relative standard deviations were in the range of 1.0–2.7%. This procedure was successfully applied with satisfactory results to the determination of β-sitosterol and cholesterol in spiked oil samples. The relative mean recoveries of oil samples ranged from 93.6% to 105.0%.  相似文献   

15.
In the present study, a three phase-based hollow fiber protected liquid-phase microextraction (HF-LPME) method combined with high-performance liquid chromatography (HPLC) for the determination of salicylates in environmental waters was developed. The HF-LPME procedure was optimized by an L16(45) orthogonal array experimental design (OAD) with five factors at four levels. Under the optimal extraction condition (pHs of donor and receiving phases of 3.0 and 6.2, respectively, extraction time of 45 min, stirring speed of 1000 rpm, and salt addition of 20% (w/v)), salicylates could be determined in a linear range from 0.025 to 1.0 μg mL−1 with a good correlation (r2 > 0.9930). The limits of detection (LODs) ranged between 0.6 ng mL−1 and 1.2 ng mL−1 for the target analytes. The relative standard deviations (RSDs) of intra-day and inter-day were in the range of 0.64–14.58% and 0.16–15.45%, respectively. This procedure afforded a convenient, sensitive, accurate and cost-saving operation with high extraction efficiency for the model analytes. The method was applied satisfactorily to the determination of salicylates in two environmental waters.  相似文献   

16.
A novel approach for preconcentration and speciation analysis of trace amount of mercury from water samples was proposed by dispersive liquid–liquid microextraction (DLLME) coupled to high performance liquid chromatography with diode array detection (HPLC-DAD). Mercury species (Hg2+, methylmercury (MeHg+) and phenylmercury (PhHg+)) were complexed with dithizone (DZ) to form hydrophobic chelates and then extracted into the fine drops of extraction solvent dispersed in the aqueous sample by dispersive solvent. After extraction, the sedimented phase was analyzed by HPLC-DAD. Some important parameters affecting the DLLME such as extraction solvent and dispersive solvent type and volume, concentration of dithizone solution, sample pH, extraction time and salt effect were investigated. Ionic liquid 1-hexyl-3-methylimidazolium hexafluorophosphate ([HMIM][PF6]) was found to be a suitable extractant for the chelates. Under the optimized conditions (extraction solvent: 70 μL of ionic liquid 1-hexyl-3-methylimidazolium hexafluorophosphate ([HMIM][PF6]); dispersive solvent: 0.75 mL of methanol containing dithizone (0.02%, m/v); pH: 4; extraction time: 5 min; and without salt addition), the limits of detection for Hg2+, MeHg+ and PhHg+ were 0.32, 0.96 and 1.91 μg L−1 (S N−1 = 3) respectively, and the relative standard deviation (RSD) was between 4.1 and 7.3% (n = 5). Three real water samples (tap water, river water and lake water) spiked with mercury species were detected by the developed method, and the relative recoveries obtained for Hg2+, MeHg+ and PhHg+ were 89.6–101.3%, 85.6–102.0% and 81.3–97.6%, respectively.  相似文献   

17.
A new method based on probe sonication extraction (USP) prior to high performance liquid chromatography (HPLC) has been developed for the determination of linear alkylbenzene sulfonates (LAS) from sewage sludge. The optimized method was designed to be cost effective compared to existing extraction methods (ultrasonic assisted extraction, Soxhlet or pressurized liquid extraction) which may require large quantities of organic solvents, or costly instrumentation or equipment.The main factors affecting the extraction efficiency (extractant volume, ultrasounds power and extraction time) were optimized using compost sludge. The detection limit of total LAS in the sludge was 10 mg kg− 1. The extraction of C10-C13 homologues is carried out using an extraction time of 7 min with 10 mL of methanol. Liquid chromatography with fluorescence (FL) detector is used for determination of LAS homologues. A mobile phase acetonitrile-water containing 0.1 M NaClO4 (65:35) and isocratic elution was used. Compounds were eluted over 6 min at a flow rate of 1 mL/min. Polar interferences are eluted between 0 and 2 min and no purification of the samples is required prior to the final determination by high performance liquid chromatography (HPLC). The recoveries of LAS in spiked sewage sludge were between 84.0% and 97.0%, which reflect the efficiency of the method for extraction of these analytes from sewage sludge. Concentration levels found were between 11,858 mg kg− 1 for digested sludge and 2379 mg kg− 1 for compost sludge.  相似文献   

18.
An in situ formation of ionic liquid was used for preconcentration of four triazole fungicides in food samples. The microextraction method was used for the first time in the literature for preconcentration of triazole fungicides. In the developed method, tributylhexadecylphosphonium bromide ([P44412]Br) and potassium hexafluorophosphate (KPF6) were used for the formation of hydrophobic ionic liquid. After centrifugation, the fine microdroplets were produced in one step, providing the extraction step in a quick and environmentally friendly manner. The functional group of the hydrophobic ionic liquid was investigated using FT-IR. Various extraction parameters were studied and optimized. In the extraction method, 0.01 g of [P44412]Br and 0.01 g of KPF6, centrifugation at 4500 rpm for 10 min were used. The optimized technique provided a good linear range (90–1000 μg L−1) and high extraction recovery, with a low limit of detection (30–50 μg L−1). Methods for the proposed in situ formation of ionic liquid were successfully applied to honey, fruit juice, and egg matrices. The recoveries were obtained in a satisfactory range of 62–112%. The results confirmed the suitability of the proposed microextraction method for selective extraction and quantification of triazole fungicides.  相似文献   

19.
A novel sample pre-treatment technique termed dispersive suspended microextraction (DSME) coupled with gas chromatography-flame photometric detection (GC-FPD) has been developed for the determination of eight organophosphorus pesticides (ethoprophos, malathion, chlorpyrifos, isocarbophos, methidathion, fenamiphos, profenofos, triazophos) in aqueous samples. In this method, both extraction and two phases’ separation process were performed by the assistance of magnetic stirring. After separating the two phases, 1 μL of the suspended phase was injected into GC for further instrument analysis. Varieties of experiment factors which could affect the experiment results were optimized and the following were selected: 12.0 μL p-xylene was selected as extraction solvent, extraction speed was 1200 rpm, extraction time was 30 s, the restoration speed was 800 rpm, the restoration time was 8 min, and no salt was added. Under the optimum conditions, limits of detections (LODs) varied between 0.01 and 0.05 μg L−1. The relative standard deviation (RSDs, n = 6) ranged from 4.6% to 12.1%. The linearity was obtained by five points in the concentration range of 0.1–100.0 μg L−1. Correlation coefficients (r) varied from 0.9964 to 0.9995. The enrichment factors (EFs) were between 206 and 243. In the final experiment, the developed method has been successfully applied to the determination of organophosphorus pesticides in wine and tap water samples and the obtained recoveries were between 83.8% and 101.3%. Compared with other pre-treatment methods, DSME has its own features and could achieve satisfied results for the analysis of trace components in complicated matrices.  相似文献   

20.
Based on carbon nanofibers (CNFs) as a solid phase extraction adsorbent, a microcolumn preconcentration method coupled to inductively coupled plasma mass spectrometry (ICP–MS) was developed for the determination of trace elements (Mn, Co and Ni). The effect of various experimental parameters such as pH, sample flow rate and volume, elution solution and interfering ions on the retention of the studied ions have been investigated systematically. During all the steps of the experimental process, Mn, Co and Ni could be quantitatively sorbed on the microcolumn containing CNFs in the range of pH 6.0–9.0, and then eluted completely with 0.5 mol ml− 1 HNO3. A preconcentration factor of 150-fold was obtained. The detection limits for Mn, Co and Ni were 40, 0.4 and 8.0 pg ml− 1, respectively, with relative standard deviations less than 6.0%. In order to validate the proposed method, two certified reference materials of human hair (GBW 07601) and mussel (GBW 08571), and water sample were analyzed with satisfactory results. The recoveries were between 95.0 and 114%.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号