首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
建立了一种在线扫集-胶束电动色谱法测定没食子酸的新方法。考察了背景溶液pH值、十二烷基硫酸钠(SDS)浓度、样品基体组成和进样时间对富集效果的影响。使用未涂层的毛细管柱(48.5 cm×75μmi.d.,有效柱长40 cm),pH9.0的20 mmol/L硼酸盐+50 mmol/LSDS为背景溶液,在紫外检测波长272 nm、运行电压18 kV的条件下,200 s内的富集倍数可达20倍。线性范围为0.62~10.30 mg/L(r=0.999),检出限(S/N=3)为0.08 mg/L,平均回收率为104%。没食子酸迁移时间和峰面积的相对标准偏差分别为1.2%和1.6%。方法快速、准确可靠、灵敏度高、重复性好,可检测石榴不同部位和石榴叶以及饮料中没食子酸的含量。  相似文献   

2.
The separation and determination of seven active ingredients in theophylline tablets by micellar electrokinetic capillary chromatography is described. On a 35 cm × 50 μm I.D. capillary, baseline separation is possible with a carrier solution containing 0.05 M sodium dodecyl sulphate (SDS) in 0.02 M borate buffer (pH 9.2) solution. The migration time of solutes increased markedly with increasing SDS concentration and slightly with increasing pH. With consecutive injections of samples, slight decreases in the migration times of the solutes occurred, but they were in parallel, owing to the temperature rise of the capillary with time. The column efficiency was influenced by the micellar concentration and applied voltage, and optimum values at which the highest theoretical plate number was achieved were established. The determination of the active ingredients was performed using hydrochlorothiazide and levamisole hydrochyloride (for ephedrine hydrochloride only) as internal standards, with good linearity with correlation coefficients from 0.9965 to 0.9999 and recoveries from 94.1 % to 101.1%. For quantitative information, measurements of peak height were better than peak area.  相似文献   

3.
In this work, a CE method with bare gold nanorods (GNRs) based pseudostationary phase was developed and applied for the separation of chondroitin sulfate (CS) isomers, CS, and dermatan sulfate (DS). The separation efficiency was investigated by varying the experimental parameters such as concentration and pH of the BGE, separation voltage, internal diameter of capillary, different size, and morphology of gold nanomaterials. Results showed that different size and morphology of gold nanomaterials had different effects on the separation of CS and DS. The best separation of CS and DS was achieved in the BGE composed of aqueous 150 mmol/L (mM) ethylenediamine + 20 mM sodium dihydrogen phosphate + 30% v/v GNRs, pH 4.5, at the separation voltage of ?10 kV. Capillary was 59.2 cm in length (effective length 49 cm), 50 μm id capillary thermostated at 25°C. CE with bare GNRs used as pseudostationary phase was shown to be a suitable technique for the separation of CS and DS mixtures with wider peaks. RSD of migration time and peak area of CS and DS were 0.13, 0.14 and 0.86, 1.07%, respectively.  相似文献   

4.
通过实验优化了葡聚糖筛分介质和运行缓冲溶液的浓度,采用十二烷基硫酸钠(SDS)无胶筛分电泳分离体系(10%(w/v)葡聚糖,0.1%SDS,10%甘油,0.2mol/LTris-硼砂,pH8.3的缓冲液)在自制的玻璃微流控芯片上高效分离了BODIPY衍生的蛋白质分子量标准样品,连续6次电泳所得迁移时间的相对标准偏差均小于0.50%。以6种蛋白质分子量的对数对其迁移时间作图,线性回归良好(r=0.994)。采用该芯片电泳分析体系对免疫球蛋白G不同片段的分子量进行了测定,所得结果与实际基本相符。  相似文献   

5.
周建忠  廖杰  钱小红  董芳霆 《色谱》1997,15(2):159-160
建立了用毛细管胶束电动色谱法(MEKC)分离19种PTH氨基酸的方法,并探讨了电压、pH值、温度、胶束浓度对氨基酸迁移时间的影响。方法具有速度快、灵敏度高、样品用量少的优点。  相似文献   

6.
The simultaneous determination of emodin, aloe-emodin and rhein, in Semen Cassiae, Qinghai Wild Dahuang tea, Ningxia Juemingzi tea, Lanzhou Juemingzi tea and Surong Juemingzi tea, has been investigated by micellar electrokinetic capillary chromatography for the fi rst time. With an electrolyte containing 15 mm borax, 30 mm SDS, 10% (v/v) ethanol, at pH 9.60 and 20 kV applied voltage, the three analytes were completely separated within 12 min. The effects of the concentration of borax, electrolyte pH, the concentrations of SDS and organic modifier and the applied voltage on electropheoretic behavior and separation were studied. The linear calibration range was 4-120 micro g/mL (r = 0.9921) for emodin, 10-200 micro g/mL (r = 0.9970) for aloe-emodin and 2-100 micro g/mL (r = 0.9971) for rhein, respectively. Under the optimum conditions, the relative standard deviation (RSD) values (n = 6) of the migration time and the peak area of each peak was 0.59-0.80% and 1.30-3.22%, respectively. The contents of the analytes in Rheum, Qinghai Wild Dahuang tea, Semen Cassiae and three other kinds of teas were easily determined with recoveries ranging from 95.3 to 104.4%.  相似文献   

7.
展学强  朱智甲  康经武 《色谱》2011,29(4):362-364
建立了以硝酸钾作为背景电解质测定阿霉素脂质体药物中微量硫酸根离子的毛细管电泳分析法。考察了分离电压、背景电解质、电渗流改性剂浓度、pH值对分离测定的影响。结果表明,当毛细管长度为60 cm(有效长度51.5 cm)、分离电压为~15 kV、缓冲溶液采用20 mmol/L硝酸钾(pH 7.0)、电渗流改性剂采用0.4 mmol/L十六烷基三甲基氯化铵(CTAC)、检测波长为202 nm时,阿霉素脂质体破乳液中硫酸根离子和氯离子在3 min内得到了基线分离,硫酸根离子迁移时间和峰面积的相对标准偏差分别小于0.01%和1.0%,检出限为5 μg/L。用该方法对阿霉素脂质体样品中的微量硫酸根离子进行了分析测定,结果令人满意。  相似文献   

8.
Li Q  Chang CK  Huie CW 《Electrophoresis》2005,26(17):3349-3359
The effects of organic solvents on the capillary electrophoresis (CE) separation of a number of important biological porphyrin methyl esters - six weakly basic, hydrophobic cyclic tetrapyrroles possessing two and four to eight methyl ester groups around the periphery of the porphyrin ring - were investigated in the mode of micellar electrokinetic chromatography (MEKC), microemulsion electrokinetic chromatography (MEEKC), and nonaqueous CE. In aqueous MEKC, partial separation of the six neutral porphyrin methyl esters was obtained with an organic modifier (acetonitrile) in the concentration range between 20 and 40%, in which sodium dodecyl sulfate (SDS) molecules might be present in the form of SDS micelles and/or SDS micelle-like aggregates. Relatively stable SDS micelles can be formed in nonaqueous MEKC using formamide as the separation medium, but the separation of the target analytes remained unsatisfactory. Improved resolution of all six porphyrin methyl esters was obtained using MEEKC with the running buffer consisting of 0.8% w/w n-heptane (oil phase), 2.25% w/w SDS and 1.0% w/w Brij 35 (mixed surfactant), 6.6% w/w 1-butanol (cosurfactant), and 30% v/v 2-propanol (second cosurfactant), but reproducibility in terms of peak areas for certain porphyrins (especially uroporphyrin I octamethyl ester) was found to be very poor. Best separation performances were achieved with nonaqueous CE separations in which the weakly basic porphyrin methyl esters were protonated under strongly acidic conditions (e.g., using 10 mM perchloric acid) in mixed organic solvents. For example, using a 50:50 mixture of methanol and acetonitrile as the separation medium, baseline separation of all six (positively charged) porphyrin methyl esters can be obtained within 3 min and the average precision (RSD, N = 13) in terms of migration time and peak area were 0.55 and 2.16%, respectively.  相似文献   

9.
建立了胶束电动毛细管色谱分离和测定大黄及其制剂三黄片中蒽醌类活性组分的方法.考察了背景电解质pH、表面活性剂浓度、有机改性剂种类和浓度对分离的影响.实验结果表明:在缓冲液pH为9.5、SDS浓度为25mmol/L、乙氰浓度为20%时的优化条件下,大黄及三黄片中蒽醌类活性组分得到基线分离且方法具有较好的重现性.  相似文献   

10.
以在线扫集-胶束毛细管电动色谱法(Sweeping-MEKC)测定了复方氨酚烷胺胶囊中的马来酸氯苯那敏、咖啡因和对乙酰氨基酚3种有效成分。考察了缓冲溶液pH值、SDS浓度、分离电压及进样时间等对分离效果的影响。优化条件:以未涂层熔融石英毛细管(55 cm×50μm,有效柱长35 cm)为分离柱;环境温度25℃;80 mmol/L十二烷基磺酸钠+20 mmol/L NaH2PO4(pH 2.2)+15%乙腈为缓冲体系,分离电压-20kV,进样时间60 s(H=20.0 cm),测量波长210 nm。在该条件下氯苯那敏、咖啡因和对乙酰氨基酚在25min内出峰,峰面积RSD均小于4%;线性范围分别为2.45~39.17、1.61~25.76、1.58~25.28 mg/L;检出限(S/N=3)分别达139、34、24μg/L,回收率分别为96%~101%、98%~102%、96%~102%。  相似文献   

11.
This paper describes a simple method for the effective and rapid separation of hydrophobic molecules on polydimethylsiloxane (PDMS) microfluidic devices using Micellar Electrokinetic Chromatography (MEKC). For these separations the addition of sodium dodecyl sulfate (SDS) served two critical roles - it provided a dynamic coating on the channel wall surfaces and formed a pseudo-stationary chromatographic phase. The SDS coating generated an EOF of 7.1 x 10(-4) cm(2) V(-1) s(-1) (1.6% relative standard deviation (RSD), n = 5), and eliminated the absorption of Rhodamine B into the bulk PDMS. High efficiency separations of Rhodamine B, TAMRA (6-carboxytetramethylrhodamine, succinimidyl ester) labeled amino acids (AA), BODIPY FL CASE (N-(4,4-difluoro-5,7-dimethyl-4-bora-3a,4a-diaza-s-indacene-3-propionyl)cysteic acid, succinimidyl ester) labeled AA's, and AlexaFluor 488 labeled Escherichia coli bacterial homogenates on PDMS chips were performed using this method. Separations of Rhodamine B and TAMRA labeled AA's using 25 mM SDS, 20% acetonitrile, and 10 mM sodium tetraborate generated efficiencies > 100,000 plates (N) or 3.3 x 10(6) N m(-1) in <25 s with run-to-run migration time reproducibilities <1% RSD over 3 h. Microchips with 30 cm long serpentine separation channels were used to separate 17 BODIPY FL CASE labeled AA's yielding efficiencies of up to 837,000 plates or 3.0 x 10(6) N m(-1). Homogenates of E. coli yielded approximately 30 resolved peaks with separation efficiencies of up to 600,000 plates or 2.4 x 10(6) N m(-1) and run-to-run migration time reproducibilities of <1% RSD over 3 h.  相似文献   

12.
解娜  丁晓静  宋宝花  李佳  王志 《色谱》2013,31(1):64-70
建立了邻苯二甲醛(OPA)、对氯间二甲基苯酚(PCMX)和三氯生3种杀菌剂同时分离测定的胶束电动毛细管色谱(MEKC)新方法。详细研究了影响上述3种杀菌剂同时分离与准确定量的因素: 如分离缓冲溶液的浓度及pH,十二烷基硫酸钠(SDS)浓度、样品缓冲溶液等。以40.2 cm (有效长度: 30 cm)×50 μm未涂层熔融石英毛细管为分离柱,20 mmol/L硼砂-80 mmol/L SDS(无需调pH)为分离缓冲溶液,2 mmol/L硼砂-8 mmol/L SDS (含体积分数为10%甲醇)为样品缓冲溶液,检测波长为214 nm。3种杀菌剂的校正峰面积的相对标准偏差(RSD)在1.1%~ 3.8%范围内,迁移时间的RSD均小于0.9%, OPA、PCMX和三氯生的检出限(LOD,信噪比为3)分别为4.0、0.4、0.4 mg/L,定量限(LOQ,信噪比为10)分别为12、1.2、1.2 mg/L,校正峰面积与相应的质量浓度分别在12~2 000 mg/L、1.2~200 mg/L和1.2~200 mg/L范围内具有良好的线性关系,相关系数分别为0.9994、0.9993和0.9995。该法前处理简单,可快速、准确地同时测定3种组分,非常适合常规实验室分析。  相似文献   

13.
The development of a mixed micellar electrokinetic capillary chromatography (MECC) method for the qualitative and quantitative determination of key components, including vanillin, 4-hydroxybenzaldehyde, 4-hydroxybenzoic acid, vanillic acid and 3-methoxybenzaldehyde, that contribute to vanilla flavour was investigated. The micellar phase consisted of sodium dodecyl sulfate (SDS) and sodium cholate (SC). The percent relative standard deviation (R.S.D.%) for migration time was <1 over six runs. The R.S.D.% for peak areas ranged between 0.85-1.96% over six runs. Peak efficiencies were excellent with theoretical plate numbers typically in the range of 130,000-200,000 per column (52 cm effective length). The limits of detection (LOD) were between 5-10 μg/ml. The quantitative data was verified by high performance liquid chromatography (HPLC) and gas chromatography (GC). The mixed MECC method was successfully applied to a number of natural vanilla extracts, nature identical extracts and synthetic flavourings.  相似文献   

14.
This investigation describes the simultaneous separation of two major non-chromophoric quaternary ammonium surfactants, alkyltrimethyl- and dialkyldimethylammonium compounds (ATMACs and DADMACs, respectively), by capillary electrophoresis (CE) using indirect UV detection. The most effective separation conditions was 10 mM phosphate buffer with 57.5% tetrahydrofuran and 3 mM sodium dodecyl sulfate (SDS) at pH 4.3, and the sample hydrodynamic injection of up to 20 s at 1 psi (approximately 60 nl), and an applied voltage of 25 kV (1 psi = 6.9 kPa). Specially, the selection of an appropriate chromophore and an internal standard (I.S.) to improve the peak identification and quantitation was systematically investigated. Decylbenzyldimethyl ammonium chloride (C10-BDMA+C-) as a chromophore with 3 mM sodium dodecyl sulfate provided the best detectability for all homologues. The reproducibility of the migration time and quantitative analysis can be improved by using tetraoctyl ammonium ion as an internal standard, giving the relative standard deviation (R.S.D.) less than 0.8% for the relative migration times, and 2.5-5.5% for the relative peak areas. A good linearity of CE analysis was obtained in the range of 1.0-20 microg/ml with r2 values of above 0.999. The analysis of cationic surfactants in commercial products of hair conditioners and fabric softeners was also performed. Electrospray mass spectrometric method was applied to evaluate the CE method, and the compatible results were obtained.  相似文献   

15.
Wu XZ  Pawliszyn J 《Electrophoresis》2002,23(4):542-549
Whole-column imaging capillary electrophoresis with a short capillary is discussed. A short capillary (3-6 cm) coated with either fluorocarbon or polyacrylamide was used as a separation capillary. The whole capillary was illuminated with 280 nm light, and the transmitted light was monitored by a linear charge-coupled device (CCD). For the short capillary, hydrodynamic flow caused by a subtle height difference between the anodic and cathodic reservoirs affected the sample migration in the capillary greatly. Several sample injection methods, including use of a cross connection, sealing of the capillary ends with a gel, and use of a gel-filled capillary, have been discussed. The experimental results showed that the peak height decreased and peak width increased with the electromigration distance. Therefore, higher sensitivity was obtained in a short capillary rather than a long capillary. The whole-column imaging CE with the short capillary has been applied for the study of conjugation reactions of protein cytochrome c with sodium dodecyl sulfate (SDS) and the dye Congo Red. The method has also been used for in situ monitoring of the electrophoretic protein desorption process. Our technique is a unique tool for the study of protein binding reactions and the interaction between analyte and inner wall of the capillary.  相似文献   

16.
The usefulness of a noncovalent, positively charged capillary coating for the efficient analysis of intact basic proteins with CE was studied. Capillaries were coated by subsequent flushing with solutions of 10% w/v Polybrene (PB), 3% w/v dextran sulfate (DS), and again 10% w/v PB. Coating characterization studies showed that stable coatings could be produced which exhibited a pH‐independent and highly reproducible EOF. The PB–DS–PB coating was evaluated with Tris phosphate BGEs of various pH using the four basic model proteins: α‐chymotrypsinogen A, ribonuclease A, cytochrome c, and lysozyme. Typical migration time RSDs for the proteins were less than 0.85%, and apparent plate numbers were above 125 000 using a capillary length of 40 cm. The high separation efficiency allowed detection of several minor impurities in the model proteins. Using a BGE of medium pH, the CE system with triple‐layer coating appeared to be useful for the repeatable profiling of recombinant humanized mouse monoclonal immunoglobulin G1 showing a characteristic pattern of glycoforms. The CE system was also applied to the characterization of two llama antibodies, which were produced in Saccharomyces cerevisiae, revealing the presence of a side product in one of the antibodies. The high migration time stability allowed the reliable determination of antibody–antigen binding by monitoring migration time shifts. Finally, the feasibility of using the PB–DS–PB coated capillaries for CE with mass spectrometric detection was shown by the characterization of the impure llama antibody sample.  相似文献   

17.
Two modes of capillary electrophoresis (CE)--free-solution capillary zone electrophoresis (CZE) and sodium dodecyl sulfate capillary electrophoresis (SDS-CE) using a non-gel sieving matrix--have been developed for comparative analysis of low-molecular-mass 2S albumin isoforms from lupins. The albumin fraction and 2S albumins were separated in uncoated fused-silica capillary by CZE with 0.02 M phosphate buffer, pH 7.3, containing the sodium salt of phytic acid. The use of phytic acid (0.025 M) as buffer modifier and ion-pairing agent improved migration reproducibility, peak shape and separation efficiency. The reduced 2S albumins were separated by SDS-CE using a high concentration (0.3-0.5 M) mixture of tris(hydroxymethyl)aminomethane and borate buffers in uncoated fused-silica capillary. Of the various polymers used as non-gel sieving matrix, SDS-CE with a 10% dextran solution was found to be suitable for separation of 2S albumin polypeptides with molecular masses of 4,000-7,000 and 8,000-11,000. The addition of glycerol or ethylene glycol to the SDS separating buffer improved the resolution of polypeptides. The examined Lupinus species showed species-specific CZE and SDS-CE migration profiles of the 2S albumins.  相似文献   

18.
A simple, rapid, and accurate method for the separation and determination of honokiol and magnolol in Magnolia officinalis and related herbal medicines was developed by combination of flow injection (FI) and capillary zone electrophoresis (CZE). The analysis was carried out using an unmodified fused-silica capillary (50-μm I.D.; total length 7.5 cm; effective length 4.5 cm). A series of optimization steps afforded the following conditions: the sample solvent consisted of 150 mM NaOH and a running buffer composed of 10 mM sodium tetraborate/10 mM sodium dihydrogenphosphate (NaH2PO4) at pH 12 was applied for the separation of the analytes. The separation could be achieved within 5 min with a sample throughput rate of up to 28 h−1. The repeatability (defined as the relative standard deviation, RSD) for honokiol and magnolol was 2.0% and 1.6% with peak area evaluation, 3.6% and 2.0% with peak height evaluation, and 2.0% and 1.4% with migration time evaluation, respectively. Regression equations revealed linear relationships (r = 0.9991–0.9998) between the peak area of each analyte and the concentration.  相似文献   

19.
The on-line sample concentration technique, micelle to solvent stacking (MSS), was studied for small organic cations (quaternary ammonium herbicides, β-blocker drugs, and tricyclic antidepressant drugs) in reversed migration micellar electrokinetic chromatography. Electrokinetic chromatography was carried out in fused silica capillaries with a background solution of sodium dodecyl sulfate (SDS) in a low pH phosphate buffer. MSS was performed using anionic SDS micelles in the sample solution for analyte transport and methanol or acetonitrile as organic solvent in the background solution for analyte effective electrophoretic mobility reversal. The solvent also allowed for the separation of the analyte test mixtures. A model for focusing and separation was developed and the mobility reversal that involved micelle collapse was experimentally verified. The effect of analyte retention factor was observed by changing the % organic solvent in the background solution or the concentration of SDS in the sample matrix. With an injection length of 31.9 cm (77% of effective capillary length) for the 7 test drugs, the LODs (S/N=3) of 5-14 ng/mL were 101-346-fold better when compared to typical injection. The linearity (R(2), range=0.025-0.8 μg/mL), intraday and interday repeatability (%RSD, n=10) were ≥0.988, <6.0% and <8.5%, respectively. In addition, analysis of spiked urine samples after 10-fold dilution with the sample matrix yielded LODs=0.02-0.10 μg/mL. These LODs are comparable to published electrophoretic methods that required off-line sample concentration. However, the practicality of the technique for more complex samples will rely on dedicated sample preparation schemes.  相似文献   

20.
Lihong Liu  Zhide Hu 《Talanta》2007,71(1):155-159
A simple, rapid, and accurate method for the separation and determination of alpinetin and cardamonin in Alpinia katsumadai Hayata was developed by combination of flow injection (FI)-micellar electrokinetic chromatography (MEKC) for the first time. The analysis was carried out using an unmodified fused-silica capillary (50 μm i.d.; total length 13.6 cm; effective length 10.3 cm) and direct ultraviolet (UV) detection at 214 nm. The sample throughput was 11-24 samples per hour using the background electrolyte (BGE) containing 4 mM sodium borate-8 mM NaH2PO4 (pH 8.1)-8 mM sodium dodecyl sulfate (SDS)-19% (v/v) ethanol. The repeatabilities (n = 4) reached relative standard deviation values (R.S.D.) of 3.0% and 2.5% for the peak areas and 2.5% and 3.1% for peak heights of alpinetin and cardamonin, respectively. Regression equations revealed linear relationships (r2: 0.9993-0.9994) between the peak area of each analyte and the concentration. Recoveries were in the range 90-92% and 99-105% for alpinetin and cardamonin, respectively.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号