首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
建立了水产品中大环内酯类抗生素[红霉素(ERM)、罗红霉素(ROM)、替米卡星(TIL)、泰乐菌素(TYL)、北里霉素(KIT)、交沙霉素(JOS)、竹桃霉素(OLM)、螺旋霉素Ⅰ(SPM-Ⅰ)]和林可胺类(林可霉素(LIN)和氯林可霉素(CLD))的高效液相色谱-电喷雾串联质谱(LC-ESI-MS/MS)检测方法.样品经提取、反相液相色谱分离净化后进行质谱分析,在选择反应监测模式(SRM)下进行特征母-子离子对信号采集.根据保留时间和母离子及两个特征子离子信息定性分析,以基峰离子进行定量.大环内酯类残留的检出限(S/N=3)为0.1~0.2μg/kg,定量限为1.0μg/kg,在1.0~200 ng/mL时峰强度与质量浓度的线性关系良好(R~2 >0.99).在虾、鳗鱼和带鱼3种基质中1.0、2.0、10.0μg/kg 3个添加水平下,除个别药物外,药物的平均回收率范围为64%~114%,RSD<12%.该法适用于各种水产品中大环内酯类残留的分析.  相似文献   

2.
A simple extraction technique has been developed for seven macrolide antibiotics in milk. The procedure involves a modified quick, easy, cheap, effective, rugged, and safe method based on acetonitrile extraction, followed by the addition of a mixture of salts (sodium sulfate, sodium chloride, and potassium carbonate) not yet reported in literature. The method was validated for tylosin and was selective, free of matrix effect, and linear in the range of 0.78–18.75 ng/mL in the final extract, corresponding to 0.125–3 times the maximum residue limit. The limit of detection, limit of quantification, decision limit, and detection capability were, respectively, 0.84, 2.79, 58.4, and 71.7 μg/kg. The overall average recovery at 25, 50, and 75 μg/kg ranged from 89–97%. Repeatability and intermediate precision expressed by relative standard deviations were below 10.5 and 12%, respectively. The extension of the validation for spiramycin, throleandomycin, oleandomycin, roxithromycin, erythromycin, and clarithromycin is under consideration since the procedure proved to be able to efficiently extract all studied macrolides, with recoveries from 74–104% at 50 μg/kg for tylosin, erythromycin, spiramycin, and oleandomycin and 20 μg/kg for throleandomycin, roxithromycin, and clarithromycin.  相似文献   

3.
谢文  丁慧瑛  奚君阳  钱艳  黄雷芳 《色谱》2007,25(3):404-407
建立了高效液相色谱-质谱/质谱测定蜂王浆中5种大环内酯类抗生素(螺旋霉素、竹桃霉素、泰乐菌素、罗红霉素、交沙霉素)残留的方法。先用三氯乙酸沉淀蜂王浆中的蛋白质,上层清液再用乙腈提取、C18小柱净化。每种抗生素选择一个母离子和两个子离子进行监测。5种大环内酯类抗生素在0.002~0.05 mg/L 范围内与其峰面积具有良好的线性关系,检测低限均为20 μg/kg,3个加标水平(每种抗生素的添加水平均为20, 100 和 200 μg/kg)下的加标回收率为73.0%~90.2%,相对标准偏差为5.6%~10.5%。  相似文献   

4.
The simple, rapid and sensitive liquid chromatographic separation of five macrolides (tilmicosin, erythromycin, tylosin, roxithromycin and josamycin) widely used in food producing animals was developed. Response surface methodology was used as an optimization method of mobile phase, column temperature and pH to provide the best resolution of these analytes. The separation was performed by using an end-capped X-Terra RP-18 column (250 × 4.6 mm I.D × 5 m) with an isocratic system of 15 mM hydrochloric acid (pH 2.5)-acetonitrile as the mobile phase at a temperature of 30°C and flow-rate of 1.0 mL/min. The suitability of the method for multi-residue determination of the macrolides is demonstrated by the analysis of milk samples spiked with tylosin. Roxithromycin was used as internal standard. The recovery of tylosin was quite good as 90.8%. The limit of quantification and detection limit were 0.024 and 0.007 μg/mL, respectively. The method was successfully applied to determination of macrolides at levels below the maximum concentration legally allowed in milk samples.  相似文献   

5.
建立了超高效液相色谱-串联质谱(UPLC-MS/MS)法测定动物源性食品中12种大环内酯类抗生素(林可霉素、阿奇霉素、螺旋霉素、替米考星、竹桃霉素、红霉素、泰乐霉素、吉他霉素、罗红霉素、克拉霉素、麦迪霉素、交沙霉素)的方法.样品均质后,用乙腈提取,正己烷净化,无水硫酸钠脱水.乙腈提取液减压浓缩后,氮气流吹干,甲醇溶解定容;采用UPLC-MS/MS电喷雾多反应监测模式检测,基质匹配标准曲线定量.实验结果表明,12种大环内酯化合物在5 ~100 μg/kg范围内线性关系良好,检出限均为5.0 μg/kg,定量下限为10 μg/kg.5种空白基质样品中,10、25、50 μg/kg加标水平的平均回收率为60% ~117%,相对标准偏差均在20%以内.该方法灵敏度高、重复性好,各项技术指标均满足国内外相关法规要求,可用于动物源性食品中12种大环内酯类抗生素残留的检测.  相似文献   

6.
An LC/MS/MS-based multiresidue quantitative method was developed for the macrolides erythromycin A, neospiramycin I, oleandomycin, spiramycin I, tilmicosin, and tylosin A in porcine kidney tissues. The Canadian Food Inspection Agency (CFIA) had as part of its analytical scope an LC/UV method for quantification of residues of two macrolide antibiotics, tilmicosin and tylosin A, in the kidney, liver, and muscle of cattle, swine, and poultry. The method could not reliably detect concentrations below 10 microg/kg. To increase the scope of the CFIA's analytical capabilities, a sensitive multiresidue quantitative method for macrolide residues in food animal tissues was required. Porcine kidney samples were extracted with acetonitrile and alkaline buffer and cleaned-up using silica-based C18 SPE cartridges. Sample extracts were analyzed using LC/MS/MS with positive electrospray ionization. Fitness for purpose was verified in a single-laboratory validation study using a second analyst. The working analytical range was 5 to 50 microg/kg. LOD and LOQ were 0.5 to 0.6 microg/kg and 1.5 to 3.0 microg/kg, respectively. Limits of identification were 0.5 to 2.0 microg/kg. Relative intermediate precisions were 8 to 17%. Average absolute recoveries were 68 to 76%.  相似文献   

7.
Determination of macrolide antibiotics by liquid chromatography   总被引:7,自引:0,他引:7  
The liquid chromatographic separation of seven macrolides used in food producing animals in the European Union has been studied. Separation was performed by using an end-capped high-purity silica-based C18 column and mobile phases consisting of phosphate buffer (pH 2.5)–acetonitrile mixtures. The effect of pH and acetonitrile percentage on the separation was examined. Two UV-based detection systems, wavelength programming and diode array, were assayed. Detection limits were in the range 6–33 μg l−1 for spiramycin, tilmicosin, tylosin, kitasamicin and josamicin and about 400 μg l−1 for erythromycin and oleandomycin. The suitability of the method for multiresidue determination of the five macrolides is demonstrated by the analysis of spiked samples of chicken muscle.  相似文献   

8.
The separation of basic macrolide antibiotics suffers from peak tailing and poor efficiency on traditional silica‐based reversed‐phase liquid chromatography columns. In this work, a C18HCE column with positively charged surface was applied to the separation of macrolides. Compared with an Acquity BEH C18 column, the C18HCE column exhibited superior performance in the aspect of peak shape and separation efficiency. The screening of mobile phase additives including formic acid, acetic acid and ammonium formate indicated that formic acid was preferable for providing symmetrical peak shapes. Moreover, the influence of formic acid content was investigated. Analysis speed and mass spectrometry compatibility were also taken into account when optimizing the separation conditions for liquid chromatography coupled with tandem mass spectrometry. The developed method was successfully utilized for the determination of macrolide residues in a honey sample. Azithromycin was chosen as the internal standard for the quantitation of spiramycin and tilmicosin, while roxithromycin was used for erythromycin, tylosin, clarithromycin, josamycin and acetylisovaleryltylosin. Good correlation coefficients (r2 > 0.9938) for all macrolides were obtained. The intra‐day and inter‐day recoveries were 73.7–134.7% and 80.7–119.7% with relative standard deviations of 2.5–8.0% and 3.9–16.1%, respectively. Outstanding sensitivity with limits of quantitation (S/N ≥ 10) of 0.02–1 μg/kg and limits of detection (S/N ≥ 3) of 0.01–0.5 μg/kg were achieved.  相似文献   

9.
A gas chromatographic-mass spectrometric (GC-MS) method using single ion monitoring (SIM) is described for the determination of residual macrolide antibiotics, oleandomycin, kitasamycin, spiramycin and tylosin, in beef and pork. For GC-MS determination, oleandomycin is acid hydrolysed to desoleandomycin and acetylated, in the same way as erythromycin. However, for elution from a GC column, the carbon-carbon double bonds in the antibiotics must be hydrogenated to single bonds before acid hydrolysis. Kitasamycin and spiramycin are therefore converted into hydroforocidine acetate and tylosin into hydro-O-mycaminosyl tylonolide acetate, which are determined by GC-MS with SIM.  相似文献   

10.
A new confirmatory method for three macrolides (tylosin, tilmicosin and erythromycin) in bovine muscle, liver and kidney by micro-LC-MS-MS using an atmospheric pressure ionisation source and an ionspray interface has been developed. Roxithromycin was used as internal standard. The molecular related ions, [M+2H]2+, at m/z 435 for tilmicosin, and [M+H]+, at m/z 734 and 916 for erythromycin and tylosin, respectively, were the precursor ions for collision-induced-dissociation and two diagnostic product ions for each macrolide were identified for the unambiguous confirmation by selected reaction monitoring LC-MS-MS. Precision values (relative standard deviations) were all below 14.9%, whereas the overall accuracy (relative error) ranged from -17.7 to -9.8% for tylosin, from -17.5 to -10.7% for tilmicosin and from -19.6 to -13.7% for erythromycin, in all the investigated bovine tissues. The limits of quantification were 30 (muscle) or 40 (liver, kidney) microg kg(-1), 20 (muscle) or 150 (liver, kidney) microg kg(-1), 50 (muscle, liver) or 80 (kidney) microg kg(-1), 20 (muscle, liver) or 50 (kidney) microg kg(-1) for tylosin, tilmicosin, erytromycin and roxithromycin, respectively.  相似文献   

11.
A rapid qualitative method using on-line column-switching liquid chromatography/tandem mass spectrometry (LC/MS/MS) was developed and validated for screening 13 target veterinary drugs: four macrolides - erythromycin A, josamycin (leucomycin A3), kitasamycin (leucomycin A5), and tylosin A; six (fluoro)quinolones - ciprofloxacin, danofloxacin, enrofloxacin, flumequine, oxolinic acid, and sarafloxacin; and lincomycin, virginiamycin M1, and trimethoprim in different animal muscles. Clindamycin, norfloxacin, nalidixic acid, oleandomycin, ormetoprim, and roxithromycin were used as the internal standards. After simple deproteination and analyte extraction of muscle samples using acetonitrile, the supernatant was subjected to on-line cleanup and direct analysis by LC/MS/MS. On-line cleanup with an extraction cartridge packed with hydrophilic-hydrophobic polymer sorbent followed by fast LC using a short C18 column resulted in a total analysis cycle of 6 min for 19 drugs. This screening method considerably reduced the time and the cost for the quantitative and confirmatory analyses. The application of a control point approach was also introduced and explained.  相似文献   

12.
A new sensitive electrochemical enzyme-linked immunosorbent assay (ELISA) for the detection of two macrolides (erythromycin and tylosin) in bovine muscle was developed, using the mouse monoclonal antibodies anti-erythromycin and anti-tylosin. The competitive indirect assay was performed using an erythromycin (or tylosin)-BSA conjugate as a coating molecule; after competition between free and coated analytes for the antibodies, the activity of the horseradish peroxidase-labelled antiglobulins was measured electrochemically using 3,3',5,5'-tetramethylbenzidine (TMB) as substrate. The detection limit of the assay was 0.4 ng ml(-1) for erythromycin and 4.0 ng ml(-1) for tylosin, while the sensitivity (25% inhibition concentration) was 1.4 ng ml(-1) for erythromycin and 13.0 ng ml(-1) for tylosin. The specificity of the assay was assessed by studying the cross-reactivity of various macrolides other than erythromycin and tylosin. The results indicate that the monoclonal antibodies anti-erythromycin and anti-tylosin can readily distinguish the target compound from other macrolides, with the exception of roxithromycin, a semisynthetic macrolide antibiotic derived from erythromycin. Fortified and real samples were analysed by the developed ELISA method and results confirmed by micro-LC-MS-MS using an atmospheric pressure ionisation (API) source and an ionspray (IS) interface. The latter provides unequivocal identification and quantification of the analytes at the level of interest. The ELISA assay showed precision (RSD) values ranging from 6.3 to 11.4% for erythromycin and from 7.5 to 12.6% for tylosin; the accuracy (relative error, RE) ranged from -16.0 to -9.8% and from -9.5 to 8.0% for erythromycin and tylosin, respectively. All results obtained demonstrate that the electrochemical ELISA is a suitable method for a sensitive, simple, rapid and reliable screening of the two macrolides in animal tissues.  相似文献   

13.
A high-performance liquid chromatography method coupled to coulometric detection has been applied for the determination, in a single run, of up to eight macrolide antibiotics (erythromycin [ERY], tylosin [TYL], tilmicosin [TILM], spiramycin 2 [SPI 2], spiramycin 3 [SPI 3], josamycin [JOS], kitasamycin [KIT], and rosamicin [ROS]) in spiked porcine and bovine urine. Quantification was performed using matrix-matched calibration with roxithromycin (ROX) as the internal standard. The detection limits for each drug were below 3.5 ng injected (equivalent to an initial concentration below 0.07 mg L–1) for porcine urine and below 5 ng injected (equivalent to an initial concentration below 0.10 mg L–1) for bovine urine. Recoveries from urine samples spiked at three different concentrations within the linear range were not significantly dependent on concentration. The entire procedure provides average macrolide recoveries ranging from 69.7 to 96.6% for bovine urine and from 75.5 and 96.1% for porcine urine.  相似文献   

14.
严丽娟  张峰  方恩华  郭彦妮  周昱  林立毅  储晓刚 《色谱》2010,28(11):1038-1042
建立了动物饲料中竹桃霉素、红霉素、吉他霉素、交沙霉素、罗红霉素、泰乐菌素6种大环内酯和林可霉素、克林霉素2种林可胺抗生素的超高效液相色谱-电喷雾串联质谱(UPLC-ESI-MS/MS)检测方法。饲料样品采用甲醇提取,Oasis HLB固相萃取柱富集净化,Waters Acquity UPLC BEH C18色谱柱分离,以0.1%甲酸和乙腈为流动相进行梯度洗脱,流速为0.3 mL/min,正离子模式扫描,多反应监测模式检测,外标法定量。实验结果表明,8种药物在1~100 μg/L范围内具有良好的线性关系。在空白饲料样品中分别添加1、10和100 μg/kg 3个加标水平的8种药物,其平均回收率为68.6%~95.2%,相对标准偏差(RSD)为4.9%~11.8%,定量限均为1 μg/kg。结果表明,该方法简便快速、灵敏度高,适用于动物饲料中大环内酯类和林可胺类抗生素的同时检测。  相似文献   

15.
The dissociation constants of six common human and veterinary antibiotics, namely, erythromycin, roxithromycin, tilmicosin, oleandomycin, josamycin, and spiramycin in 15?%, 25?%, 40?% and 50?% (v/v) methanol?Cwater solvent mixtures were determined by UV/pH titration and correlated with the Kamlet and Taft solvatochromic parameters, ?? ?, ?? and ??. Kamlet and Taft??s general equation was reduced to two terms by combined factor analysis and target factor analysis in these mixtures: the independent term and polarity/polarizability ?? ?, which are solvatochromic parameters. The influence of methanol on the dissociation constants was investigated. Further, the quasi-lattice quasi-chemical (QLQC) model of preferential solvation has been applied to quantify the preferential solvation by water of electrolytes in methanol?Cwater mixtures.  相似文献   

16.
A method for the analysis of several macrolide and ionophore antibiotics as well as tiamulin in liquid manure was developed. Reversed-phase liquid chromatography and atmospheric pressure chemical ionisation (APCI) tandem mass spectrometry was used for detection.High-performance liquid chromatographic (HPLC) separation of the antibiotics was achieved in 35 min. The analytes were extracted with ethyl acetate and the extracts were cleaned up by solid-phase extraction on a diol SPE cartridge. Recovery experiments with spiked liquid manure concentrations varying from 6 to 2,000 microg kg(-1) gave constant recovery rates. The recovery rates for the macrolides erythromycin, roxithromycin and oleandomycin were 75-94%, that for the ionophore salinomycin was 119%, while that for the pleuromutilin tiamulin was 123%, when using a macrolide internal standard. The relative standard deviation was found to be 15-36% and the limits of detection were 0.4-11.0 micro g kg(-1).The maximum concentrations found in manure samples were 43 micro g kg(-1) for tiamulin and 11 micro g kg(-1) for salinomycin.  相似文献   

17.
Zhou J  Chen Y  Cassidy R 《Electrophoresis》2000,21(7):1349-1353
Separation and determination of erythromycin, spiramycin and oleandomycin by capillary zone electrophoresis coupled with fast reductive voltammetric detection using an Hg-film electrode was investigated in a simple aqueous phosphate buffer system. The influence of pH, concentration of phosphate, applied voltage, capillary length and dimension on the separation was examined and optimized. The entire separation of erythromycin, spiramycin, and oleandomycin was achieved in a 0.2 mol/L phosphate buffer system without organic modifiers. The electrochemical detection parameters, such as electrode material, applied waveform, scan rate, preconcentration potentials and preconcentration times, were investigated and discussed. This approach provides high separation efficiency and high sensitivity for all compounds, with detection limits (3 x peak-to-peak baseline noise) of 7.5 x 10(-8) mol/L for spiramycin, and 3 x 10(-7) mol/ L for erythromycin and oleandomycin. The calibration plot of peak areas for each separated peak vs. concentration of analyte was found to be linear over three orders of magnitude.  相似文献   

18.
A novel universal aerosol-based detector Nano Quantity Analyte Detector – NQAD™, connected with an ultra-performance liquid chromatography system is described. The detector was employed for detection of selected antibiotic compounds – macrolides (oleandomycin, erythromycin, troleandomycin, clarithromycin and roxithromycin) that are hard to detect using classical UV detectors due to the lack of chromophores. The determined lowest detection limits under isocratic conditions for these compounds ranged from 3.0 to 5.4 μg/mL. The suitability of the detector connected with ultra high-performance liquid chromatography in the gradient mode was tested on a more complex mixture containing 12 antibiotics. The detector exhibited full compatibility under both the elution modes when UHPLC separations were achieved in relatively short run times.  相似文献   

19.
The potentiometric measurement of lipoic acid reduction was used to evaluate and compare the in vitro antibacterial activity of four macrolides against sensitive strains of Staphylococcus aureus and Group A Streptococcus. Apparent growth rates of organisms submitted to different antibiotic concentrations could be calculated from the potentiometric data, and a potentiometric minimal inhibitory concentration (MIC) was defined as the antibiotic concentration corresponding to an apparent zero growth rate. The potentiometric MIC of roxithromycin was similar to that of josamycin. Erythromycin and spiramycin exhibited respectively the strongest and the lowest inhibiting power. These potentiometric results were in good agreement with classical MICs. They show that the lipoic acid-based assay may usefully complement the conventional tests of in vitro antibacterial susceptibility to antibiotics.  相似文献   

20.
A simple, reliable, and fast multiresidue method has been developed for the determination of 17 veterinary drugs belonging to several families (macrolides, sulfonamides, and anthelmintics) in cheese at trace levels. Ultra‐high‐performance LC coupled to MS/MS has been used for the analysis of these compounds in less than 9 min. Veterinary drug residues have been extracted from cheese samples using a QuEChERS (quick, easy, cheap, effective, rugged, and safe)‐based extraction procedure without applying any further clean‐up step. Matrix‐matched calibration was used for quantification and recoveries were calculated at three concentration levels (10, 50, and 100 μg/kg). The obtained values ranged from 70 to 110% for the selected compounds except for tylosin and josamycin at 100 μg/kg (111.7 and 112.7%, respectively). Intra‐ and interday precision were also evaluated and RSDs were lower than 25% in all the cases. LOQs ranged from 0.3 μg/kg (for thiabendazole, oxfendazole, mebendazole, josamycin, and fenbendazole) to 10.5 μg/kg (abamectin), whereas decision limit and detection capability ranged from 2.3 (thiabendazole) to 11.3 (abamectin) and 4.2 (thiabendazole) to 14.3 μg/kg (abamectin), respectively. Finally, 13 samples were analyzed and traces of thiabendazole were detected in two different cheeses.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号