共查询到20条相似文献,搜索用时 12 毫秒
1.
Murali R. Cholemari 《Experiments in fluids》2007,42(6):913-922
The systematic tendency of PIV evaluations to bias towards integral pixel values is known as peak-locking. These errors, although
small, significantly affect the statistics extracted from such measurements. In this paper, the process by which such errors
accrue is modeled, and a scheme for the removal of the same is suggested. Specifically, the modeling process considers FFT
PIV with discrete window offset. The results are applied to actual situations and the results are found to be encouraging.
The process is computationally inexpensive, and can be applied as a post processing technique to existing data to correct
peak-locking. 相似文献
2.
The effect of a discrete window offset on the accuracy of cross-correlation analysis of digital PIV recordings 总被引:9,自引:15,他引:9
This paper describes how the accuracy for estimating the location of the displacement-correlation peak in (digital) particle
image velocimetry (PIV) can be optimized by the use of a window offset equal to the integer-pixel displacement. The method
works for both cross-correlation analysis of single-exposure image pairs and multiple-exposure images. The effect is predicted
by an analytical model for the statistical properties of estimators for the displacement, and it is observed in the analysis
of synthetic PIV images of isotropic turbulence, and in actual measurements of grid-generated turbulence and of fully-developed
turbulent pipe flow.
Received: 29 April 1996/Accepted: 29 October 1996 相似文献
3.
Local field correction particle image velocimetry (LFC-PIV) has become an established alternative among high-resolution PIV techniques. Previous works by the authors introduced its implementation by means of simple algorithms. In these works the initial limitation of the method, which was related to the mean distance between particles, was removed. Comparison with other contemporary high-resolution techniques indicates that it offers advantages in robustness and accuracy. The trade-off for this better performance is a heavier computing load. Until now, the computing time that this load requires has not been characterized in detail, since this computing time could be substantially reduced by accepting a reduction in accuracy. This paper focuses on the characterization of the trade-off between time and accuracy, thus offering a new perspective to PIV. In this field, LFC-PIV offers a wide range of possibilities that are described in the paper. Several alternative schemes for LFC-PIV are tested, together with an analysis of the influence of the number of iterations. Performance figures for both accuracy and expended time are given. Metrological evaluation is carried out over synthetic images. A test of coherence between these results and the performance on real images is also presented. The paper shows that even for a limited number of iterations this technique offers advantages. 相似文献
4.
A simple model was constructed to study the effect of peak-locking on the accuracy of particle image velocimetry (PIV) turbulence statistics. A crucial parameter is the ratio between the root-mean-square (rms) velocity and the discretization velocity, which reflects the number of peaks distributed over the velocity probability density functions. When the ratio of the discretization velocity, which is set by the PIV setup parameters, to the rms, given by the flow, is larger than two, the maximum errors introduced in the mean and rms values become significant (larger than 1%). The errors introduced also depend on the amplitude, or severity, of the peak-locking, and whether the mean displacement corresponds to an integer or a fractional number of pixels. The peak-locking affects the statistical moments of different order in such a way that the errors are phase shifted. The proposed model can be used to predict errors in the turbulence statistics in a laboratory PIV experiment. According to our model predictions, the most significant influence of peak-locking in a boundary layer type of flow is an overall underestimation of the wall-normal rms. Our predictions are in good agreement with our experimental results from turbulent boundary layers and the recent experimental results from a turbulent channel flow by Christensen (Exp Fluids 36:484–497, 2004) for a case of moderate peak-locking.
相似文献
K. P. AngeleEmail: |
5.
6.
7.
On the accuracy of velocity and vorticity measurements with PIV 总被引:3,自引:0,他引:3
A number of numerical techniques aimed at improving the accuracy of measurements using the correlation approach in Particle
Image Velocimetry, PIV, are proposed and investigated. In this approach the velocity (displacement) is found as the location
of a peak in the correlation map. Based on an experimental model the best performing peak finding approaches are selected
among different strategies. Second, an algorithm is proposed which minimizes errors on the estimates of vorticity using velocity
distributions obtained by means of PIV. The proposed methods are experimentally validated against a flow with known properties.
Work supported by NASA Ames Research Center 相似文献
8.
The fully digital evaluation of photographic PIV recordings 总被引:4,自引:0,他引:4
Christian Willert 《Applied Scientific Research》1996,56(2-3):79-102
The performance of a purely digital evaluation system for photographic PIV recordings is described. High resolution digital images are obtained from the 35 mm negatives using a commonly available slide scanner. Together with the continually improving capabilities of standard computers, this evaluation system is a cost effective alternative to the traditional analog optical/digital (Young's fringe method) and purely optical PIV interrogation systems. Compared to the optical systems the fully digital evaluation can provide a higher spatial resolution while maintaining a similar measurement uncertainty. Using actual PIV recordings absolute measurement uncertainties are obtained and further predictions toward optimal displacement data recovery are made with the aid of Monte-Carlo simulations. Measurement uncertainties are minimized for particle image diameters on the order of 2 pixels while the reduction of the image depth (i.e. bits/pixel) has little effect. The overall performance of the described digital evaluation is compared to two types of optical evaluation systems.Affiliated with DNW-NWB, DLR-Braunschweig. 相似文献
9.
The reliable measurement of mean flow properties near walls and interfaces between different fluids or fluid and gas phases is a very important task, as well as a challenging problem, in many fields of science and technology. Due to the decreasing concentration of tracer particles and the strong flow gradients, these velocity measurements are usually biased. To investigate the reason and the effect of the bias errors systematically, a detailed theoretical analysis was performed using window-correlation, singe-pixel ensemble-correlation and particle tracking evaluation methods. The different findings were validated experimentally for microscopic, long-range microscopic and large field imaging conditions. It is shown that for constant flow gradients and homogeneous particle image density, the bias errors are usually averaged out. This legitimates the use of these techniques far away from walls or interfaces. However, for inhomogeneous seeding and/or nonconstant flow gradients, only PTV image analysis techniques give reliable results. This implies that for wall distances below half an interrogation window dimension, the singe-pixel ensemble-correlation or PTV evaluation should always be applied. For distances smaller than the particle image diameter, only PTV yields reliable results. 相似文献
10.
Results are presented from a single and dual lens endoscopic PIV imaging system with a view to application of PIV where optical access is restricted, such as internal combustion engines and other internal flows. PIV images taken from the single lens system were processed using cross-correlation and a quadratic distortion-mapping function. The dual lens images were processed using cross-correlation, a cubic mapping function, and standard stereoscopic relationships. Comparisons between the single and dual lens systems show the single lens system to have in-plane errors, caused by perspective effects, of an order of magnitude greater than the stereoscopic dual lens endoscopic PIV system. The stereo arrangement is recommended wherever quantitative velocimetry is required, and may also prove useful in general endoscopic inspection where dimensional measurements are to be estimated. 相似文献
11.
Micro PIV uses volume illumination; therefore, the velocity measured at the focal plane is a weighted average of the velocities
within the measurement volume. The contribution of out-of-focus particles to the PIV correlation can generate significant
measurement errors particularly in near wall regions. We present a new application of image overlapping, which is shown to
be very effective in improving the accuracy of time-averaged velocity measurements by effectively reducing the measurement
depth. The performance of image overlapping and correlation averaging were studied using synthetic and experimental images
of micro channel flow, both with and without image pre-processing. The results show that for flows without particle clumping,
image overlapping provides the best measurement accuracy without any need for image pre-processing. For flows with particle
clumping, image overlapping combined with band-pass filtering provides the best measurement accuracy. When overlapped images
are saturated with particles due to a large number of image pairs, image overlapping measurement still does not show any visible
pixel-locking effect. Image overlapping was found to have comparable or slightly reduced pixel-locking effects compared to
correlation averaging. In addition, image overlapping utilizes significantly fewer computational resources than the other
techniques. 相似文献
12.
A numerical implementation of the advection equation is proposed to increase the temporal resolution of PIV time series. The
method is based on the principle that velocity fluctuations are transported passively, similar to Taylor’s hypothesis of frozen turbulence. In the present work, the advection model is extended to unsteady three-dimensional flows. The main objective of the method
is that of lowering the requirement on the PIV repetition rate from the Eulerian frequency toward the Lagrangian one. The
local trajectory of the fluid parcel is obtained by forward projection of the instantaneous velocity at the preceding time
instant and backward projection from the subsequent time step. The trajectories are approximated by the instantaneous streamlines,
which yields accurate results when the amplitude of velocity fluctuations is small with respect to the convective motion.
The verification is performed with two experiments conducted at temporal resolutions significantly higher than that dictated
by Nyquist criterion. The flow past the trailing edge of a NACA0012 airfoil closely approximates frozen turbulence, where the largest ratio between the Lagrangian and Eulerian temporal scales is expected. An order of magnitude reduction
of the needed acquisition frequency is demonstrated by the velocity spectra of super-sampled series. The application to three-dimensional
data is made with time-resolved tomographic PIV measurements of a transitional jet. Here, the 3D advection equation is implemented
to estimate the fluid trajectories. The reduction in the minimum sampling rate by the use of super-sampling in this case is
less, due to the fact that vortices occurring in the jet shear layer are not well approximated by sole advection at large
time separation. Both cases reveal that the current requirements for time-resolved PIV experiments can be revised when information is poured from space to time. An additional favorable effect is observed by the analysis in the frequency domain whereby the spectrum becomes significantly
less prone to aliasing error for the super-sampled data series. 相似文献
13.
A novel, accurate and simple stereo particle image velocimetry (SPIV) technique utilising three cameras is presented. The key feature of the new technique is that there is no need of a separate calibration phase. The calibration data are measured concurrently with the PIV data by a third paraxial camera. This has the benefit of improving ease of use and reducing the time taken to obtain data. This third camera also provides useful velocity information, considerably improving the accuracy of the resolved 3D vectors. The additional redundancy provided by this third perspective in the stereo reconstruction equations suggests a least-squares approach to their solution. The least-squares process further improves the utility of the technique by means of the reconstruction residual. Detailed error analysis shows that this residual is an accurate predictor of resolved vector errors. The new technique is rigorously validated using both pure translation and rotation test cases. However, while this kind of validation is standard, it is shown that such validation is substantially flawed. The case of the well-known confined vortex breakdown flow is offered as an alternative validation. This flow is readily evaluated using CFD methods, allowing a detailed comparison of the data and evaluation of PIV errors in their entirety for this technique. 相似文献
14.
T. Astarita 《Experiments in fluids》2006,40(6):977-987
As testified by a previous article (Astarita and Cardone in Exp Fluids 38:233–243, 2005), a critical point that can influence significantly the accuracy of image deformation methods (IDM) for particle image velocimetry (PIV) is the interpolation scheme (IS) used in the reconstruction of deformed images. In the cited paper the effect of noise has been neglected and for this reason in this follow-up paper the influence of the IS, in the presence of noise, on both accuracy and spatial resolution is studied. Performance assessment is conducted using synthetic images with particles of Gaussian shape and with constant and sinusoidal displacement fields. Both the local and the top hat moving average approaches are investigated and the modulation transfer function, the total and bias errors have been used to evaluate the performances of IDMs for PIV applications. The results show that, when a high noise level is present in the images, the influence of the IS is less relevant than what was shown by Astarita and Cardone (Exp Fluids 38:233–243, 2005). 相似文献
15.
The effect of independent variations of the intensity of individual tracer particles between consecutive images on the accuracy
of common displacement estimation methods in particle image velocimetry (PIV) is investigated. Such variations can be observed,
e.g., in flows with components perpendicular to the illumination sheet, leading to out-of-plane displacements of the tracer
particles. The achievable accuracy of PIV measurements is shown to be limited by this effect alone to be of the order of 0.1
pixel, yielding a basic limitation of the PIV technique.
相似文献
Holger NobachEmail: |
16.
A digital mask technique for reducing the bias error of the correlation-based PIV interrogation algorithm 总被引:1,自引:0,他引:1
In this paper the bias phenomenon in the evaluation of PIV recordings by using the correlation-based interrogation algorithm
is discussed, and a digital mask technique, that can effectively reduce the bias error, is introduced. The correlation-based
interrogation algorithm, when masked with a Gaussian window function, can achieve a higher evaluation accuracy not only for
PIV recordings of flows with small velocity gradients, but also for that of flows with large gradients.
Received: 14 October 1998/Accepted: 20 July 1999 相似文献
17.
In this communication, the Digital Image Compression (DIC) – PIV system is introduced. The present system allows the measurement
of mean and RMS velocities in turbulent flow fields, using JPEG digital image compression technique for on-line recording
of thousands of images. The decompression and subsequent analysis of the images, performed by means of digital cross-correlation
technique, is carried out off-line. Errors incurred by the application of the compression method are assessed and discussed.
The effect of the compression is firstly analysed by linearly traversing (synthetic) computer-generated PIV-images at constant
velocity. Secondly, accurate LDA measurements and data from direct numerical simulation (DNS) are used as a basis for the
analysis in a low Reynolds number open water channel flow. The results show that excellent agreement between LDA and DIC–PIV
measurements for mean and RMS velocities can be achieved using a compression factor up to 12.
Received: 27 August 1996 / Accepted: 15 December 1998 相似文献
18.
Sara Nauri José Nogueira Antonio Lecuona Mathieu Legrand Pedro A. Rodríguez 《Experiments in fluids》2008,45(4):609-621
Particle image velocimetry with local field correction (LFC PIV) has been tested in the past to obtain two components of velocity
in a two dimensional domain (2D2C). When compared to conventional correlation based algorithms, this advanced technique has
shown improvements in three important aspects: robustness, resolution and ability to cope with large displacements gradients.
A further step in the development of PIV algorithms consists in the combination of LFC with the stereo technique, which is
able to obtain three components of velocity in a plane (2D3C PIV). In this work this combination is implemented and its performance
is evaluated carrying out the following two different tasks:
The first task has been achieved using synthetic images. Afterwards the coherence of the results has been checked with real
images. The results show improvement of Stereo-LFC PIV in respect to Stereo-Multigrid PIV enhanced with image distortion.
The performance of Stereo-LFC when only large scales are involved shows an increase of the dynamic range of measurable vorticity.
When small scales are analysed, the magnitude of the error resulting when using Stereo-LFC is about half of the one obtained
for the Stereo-Multigrid measurements. Results with errors below 20% have been achieved for some of the cases with peak vorticities
as large as 1.8 Δt
−1 (in the absence of out-of-plane displacements), out-of-plane loss of particle pairs of 65% (with a low peak vorticity of
0.06 Δt
−1) and peak vorticities as large as 1.5 Δt
−1 with 50% particle pair loss. For the second task most of the information has been obtained using real images. It has been
found that the resolution limit is very dependent on the robustness of the algorithms against image defects and variability.
The results show a remarkable improvement when using the Stereo-LFC PIV processing, although a full quantification and characterization
would need further study because of the variety of noise sources possible in a real image. 相似文献
– | Comparison of robustness and accuracy for large and small scale flow structures. This is carried out using three techniques: the conventional Stereo PIV, the Stereo-LFC PIV and the Stereo-Multigrid PIV enhanced with image distortion. |
– | Insight on the limit of resolvable scales for the Stereo-LFC. This task is relevant because the resolution attainable by this combination is higher than what has been obtained by the rest of the herein used algorithms. |
19.
Characterization of the tip clearance flow in an axial compressor using 3-D digital PIV 总被引:2,自引:0,他引:2
Mark P. Wernet Dale Van Zante Tony J. Strazisar W. Trevor John P. Susan Prahst 《Experiments in fluids》2005,39(4):743-753
The accurate characterization and simulation of rotor tip clearance flows has received much attention in recent years due to their impact on compressor performance and stability. At NASA Glenn the first known three dimensional digital particle image velocimetry (DPIV) measurements of the tip region of a low speed compressor rotor have been acquired to characterize the behavior of the rotor tip clearance flow. The measurements were acquired phase-locked to the rotor position so that changes in the tip clearance vortex position relative to the rotor blade can be seen. The DPIV technique allows the magnitude and relative contributions of both the asynchronous motions of a coherent structure and the temporal unsteadiness to be evaluated. Comparison of measurements taken at the peak efficiency and at near stall operating conditions characterizes the mean position of the clearance vortex and the changes in the unsteady behavior of the vortex with blade loading. Comparisons of the 3-D DPIV measurements at the compressor design point to a 3D steady N-S solution are also done to assess the fidelity of steady, single-passage simulations to model an unsteady flow field. 相似文献
20.
Andreas Fouras David Lo Jacono Chuong Vinh Nguyen Kerry Hourigan 《Experiments in fluids》2009,47(4-5):569-577
A method is proposed that allows three-dimensional (3D) two-component measurements to be made by means of particle image velocimetry (PIV) in any volume illuminated over a finite thickness. The method is based on decomposing the cross-correlation function into various contributions at different depths. Because the technique is based on 3D decomposition of the correlation function and not reconstruction of particle images, there is no limit to particle seeding density as experienced by 3D particle tracking algorithms such as defocusing PIV and tomographic PIV. Correlations from different depths are differentiated by the variation in point spread function of the lens used to image the measurement volume over that range of depths. A number of examples are demonstrated by use of synthetic images which simulate micro-PIV (μPIV) experiments. These examples vary from the trivial case of Couette flow (linear variation of one velocity component over depth) to a general case where both velocity components vary by different complex functions over the depth. A final validation—the measurement of a parabolic velocity profile over the depth of a microchannel flow—is presented. The same method could also be applied using a thick light sheet in macro-scale PIV and in a stereo configuration for 3D three-component PIV. 相似文献