首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
对齐矣物中各单分散组分的折光指数增量、尺寸排除色谱响应面积与重量分数之间的相互关系作了数学分析。折光指数增量的分子量依赖性完全起源于端基效应,提出了一个对高分子的尺寸排除色谱谱图,作掀光指数增量改正的理论方程,其中包含端基与结构重复单元的分子量以及两者折光指数增量的比值,此比值可事先用Lorenz-Lorentz或Gladstone-Dale方程计算得到,理论的推断从苯乙烯齐聚物的HPSEC实验数据得到了证实。  相似文献   

2.
对齐聚物中各半分散组分的折光指数增量、尺寸排除色谱响应面积与重量分数之间的相互关系作了数学分析。折光指数增量的分子量依赖性完全起源于端基效应。提出了一个对高分子的尺寸排除色谱谱图,作折光指数增量改正的理论方程,其中包含端基与结构重复单元的分子量以及两者折光指数增量的比值,此比值可事先用Lorenz-Lorentz或Gladstone-Dale方程计算得到。理论的推断从苯乙烯齐聚物的HPSEC实验数据得到了证实。  相似文献   

3.
Discretization of a size-exclusion chromatography (SEC) chromatogram is shown here to be an important calculation for characterizing the distribution of a polydisperse polymer, especially when the polydispersity is large. Commercial poly-glucose maltodextrins are known to have such a polydispersity. A mathematical discretization method with Gaussian peaks centered on each individual degree of polymerization is proposed and is performed on the entire SEC chromatogram for three different grades of corn maltodextrins. Because SEC and high-performance anion exchange chromatography with pulsed amperometric detection (HPAEC-PAD) are based on different separation mechanisms, they can be considered orthogonal techniques, and HPAEC-PAD was therefore used to validate the SEC discretization procedure. Because this validation proved satisfactory for all commercially available oligomers, the discretization is extended to all of their SEC chromatograms. Comparing the number-average molar weight and the weight-average molar weight before and after the mathematical discretization verifies that such a mathematical treatment does not denaturate the chromatogram. This approach tentatively leads to a more exhaustive characterization of a broadly polydisperse sample, such as maltodextrins, than was previously available, as it (i) gets rid of the apparent, chemically irrelevant, continuous molar weight distribution obtained by raw SEC and (ii) addresses the current detection and quantitation limits of the HPAEC-PAD technique without any sample treatment.  相似文献   

4.
A novel method for analysing polysaccharide materials is described which employs size-exclusion chromatography (SEC) followed by detection by on-line electrospray ionisation mass spectrometry (ESI-MS) and off-line matrix-assisted laser desorption/ionisation time-of-flight mass spectrometry (MALDI-TOFMS). It is demonstrated through SEC/ESI ion trap mass spectrometry that the formation of multiply charged oligomer ions, which bind up to five sodium cations, allows the rapid analysis of polysaccharide ions with molecular weights in excess of 9 kDa. MALDI spectra generated from fractionation of the effluent collected from the same SEC separation are shown to be in good agreement with the ESI spectra with respect to molecular weight distributions and types of ions generated. ESI and MALDI mass spectra of samples obtained from sequential graded ethanol precipitation and SEC fractionation of acid and enzymatically digested arabinoxylan polysaccharides show important structural differences between polysaccharide fragments. In addition, a comparison is made between the mass spectra of native and permethylated SEC-separated fragments of acid and enzymatically treated arabinogalactan. Linkage information of the permethylated arabinogalactan oligomers can be rapidly established through the use of on-line SEC/ESI-MS( n) experiments.  相似文献   

5.
Matrix-assisted laser desorption ionization time-of-flight mass spectrometry (MALDI-TOFMS) can be used to determine number- and weight-average molecular weights of narrow polydispersity polymers. In this work, several possible sources of error in determining molecular weights of polymers with narrow polydispersity by MALDI-TOFMS are rigorously examined. These include the change in polymer distribution function, broadening or narrowing of the overall distribution, and the truncation of selected oligomer peaks within a distribution (i.e., the oligomer peaks at the high-and low-mass tails expected to be observed are not detected). These variations could be brought about by a limited detection sensitivity, background interference, and/or mass discrimination of oligomer analysis in MALDI-TOFMS. For narrow polydispersity polystyrenes, it is shown that by using an appropriate MALDI matrix and sample preparation protocol and a sensitive ion detection instrument, no systematic errors from these possible variations were detected within the experimental precision (0.5% relative standard deviation) of the MALDI method. It is concluded that MALDI mass spectrometry can provide accurate molecular weight and molecular weight distribution information for narrow polydispersity polymers, at least for polystyrenes examined in this work. The implications of this finding for polymer analysis are discussed.  相似文献   

6.
Quantitative evaluation of polymer composition across the SEC chromatogram can provide more accurate characterization of heterogeneous polymer samples for problem solving and for material specification. To this end Fourier-transform infrared spectroscopy (FTIR) with solvent-evaporation interfaces has become a very powerful detector for size-exclusion chromatography (SEC). The solvent-evaporation interface removes the mobile phase at the exit of the chromatograph and deposits the separated molecular sizes as polymer films on infrared transparent substrates. Quantitative interpretation of the FTIR spectra obtained from these films has recently been found to be best accomplished by using partial least squares. In this paper, polystyrene and poly(methylmethacrylate), alone, as blends, and a copolymer were analyzed in a SEC equipped with an evaporative interface. Molecular weight effects, wavelength selection, the effect of averaging spectra on results, and selection of the best data preprocessing method were investigated. General methods of evaluating these variables were developed to arrive at conditions for this particular "model" situation in order to provide a basis for the analysis of more complex polymers.  相似文献   

7.
This paper presents a modeling-based approach to the prediction of the molar mass distribution of the various species in a star-branched polycondensation mixture. The interpretation of experimental SEC data of the mixture of linear, cyclic and star-branched molecules is not straightforward, because of the different sizes of those molecules (having the same molecular mass). Therefore we have opted to use SEC analysis with only a concentration detector and fit the experimental data to the theoretical mass distribution, corrected for the volume of the various molecules. This allows the relative fraction and the distribution of the various species in the mixture (linear, cyclic and star-branched) to be determined. To demonstrate this, the six-arm star-branched poly-epsilon-caprolactam based on the six-functional coupling molecule, hexa(6-caproic acid) melamine has been analyzed. Five polymer mixtures with different initial concentration of coupling molecule have been synthesized. As the initial concentration of coupling molecule increased, we found that the weight fraction of star-branched molecules increased, while the weight fraction of linear and cyclic molecules decreased. We also found that the weight-average molar mass and the arm length decrease as the initial fraction of the coupling molecule increases.  相似文献   

8.
Advances in analytical methodology for speciation of manganese in pine nuts are presented in this work. The approach is based on the use of orthogonal chromatographic systems, namely size-exclusion chromatography (SEC) of the extracts and strong anion exchange (IEC) of the fractions collected by the first column. In both columns, manganese elution is first monitored by a quadrupole inductively coupled plasma mass spectrometry (ICP-MS) instrument equipped with an octopole reaction cell and an ultraviolet (UV) detector. SEC is performed by using two columns covering the molecular weight range from <10 to 70 kDa that allows an initial screening of the molecular weight of the Mn species. The higher resolution capability of the low molecular weight range column is the reason to use the latter for further experiments. The fraction from SEC-ICP-MS in which Mn is present at highest concentration is submitted to IEC-ICP-MS allowing Mn-citrate and MnCl(2) identification by retention time matching with standards. The concentration of these species is estimated to be 75 and 125 microg kg(-1) (as Mn), respectively, in the pine nuts samples and the presence of Mn-citrate is confirmed by nanoelectrospray ionization quadrupole time-of-flight mass spectrometry (nESI-QqTOF-MS). In the same fraction, a third Mn-containing peak is detected in the IEC-UV-ICP-MS chromatogram. This peak corresponds to a protein containing Mn that was later submitted to a tryptic digestion and analyzed by nESI-QqTOF. The MS/MS data of a doubly charged peptide are used to obtain the sequence of the protein with the Mascot search engine. The peak turned out to be isocitrate dehydrogenase, a protein commonly associated with Mn. Copyright (c) 2008 John Wiley & Sons, Ltd.  相似文献   

9.
Size-exclusion chromatography (SEC) and capillary zone electrophoresis (CZE) coupled with inductively coupled plasma mass spectrometry were applied to characterize low, medium, and high molecular weight cadmium complexes with glutathione and phytochelatins (PCs). The dominant stoichiometry of the complexes formed in vitro was established as 1:1 using electrospray ionization mass spectrometry. Calculated molecular masses of Cd1L1 complexes were used for calibration of the SEC and CZE methods. The results showed a lower (2 kDa) SEC column exclusion limit for cadmium complexes compared with free peptides (10 kDa), and most of the high molecular weight cadmium species were eluted in the void volume of the column. Moreover, the CZE method based on the semiempirical model of Offord to elucidate peptide migration allowed us to show a high propensity of Cd–PC complexes for polymorphism on complexation, which was also observed for extracts of Arabidopsis thaliana treated with cadmium. All the information presented is vital for understanding the mechanism of metal deactivation in plants.
Figure
Estimation of molecular mass of Cd-thiopeptide complexes by size electrophoretic mobility  相似文献   

10.
本文提出了从未知样品的特性粘数和GPC图谱计算重均分子量的新方法,该方法可用于计算窄分布和宽分布的未知Mark-Houwink 常数的样品的重均分子量。用七个不同分子量和不同分布的实例验证了所提出的方法。结果与已知Mark-Houwink常数用普适校准法得到的结果一致。  相似文献   

11.
Abstract

The mixture of methylene chloride/hexafluoroisopropanol (70/30, v/v) is an excellent polyester solvent, but its low boiling point causes unstable flow when it is used for size exclusion chromatography (SEC). In high-performance SEC experiments, retention time is normally used to measure elution volume; however, unstable flow makes it difficult to calibrate an SEC column set or calculate molecular weight parameters from a chromatogram. We have devised a simple and inexpensive method to compensate for the effect of unstable flow in SEC calculations. A calibration marker injected along with each sample is used to indicate flow-rate variations. The ratio of the sample retention time to the marker retention time is invariant to flow-rate changes and is used in place of retention time as a measure of elution volume in the universal calibration technique. Calibrating a column set and analyzing chromatograms by this method result in a large improvement in the accuracy and precision of calculated molecular weight parameters.  相似文献   

12.
A method for calculating diffusion rates for individual species in concentrated regime is outlined. The effects of monomeric friction coefficient, Flory–Huggins thermodynamic interaction parameter, individual species molecular weights, local molecular weights distribution, and local Tg are precisely calculated. The method is used to calculate individual concentration profiles generated by diffusion of multicomponent polymer blends, and experimentally tested. Polystyrene with a bimodal molecular weight distribution is allowed to diffuse in a blend of polyphenylene oxide and polystyrene. Local physical properties change markedly along the interdiffusion path and, therefore, this is a demanding test for the proposed calculation method. The simulated concentration profiles are compared with results obtained by using two independent experimental techniques: Raman spectroscopy and dynamic mechanical analyzer (DMA). The total polystyrene (PS) concentration profiles, calculated using the proposed method, agree well with Raman spectroscopy results. Simulated DMA results—which are sensitive to the PS species molecular weight distribution—obtained using the concentration profiles, calculated for each PS molecular weight species agree well with the experimental DMA results. Calculations based on average molecular weights give incorrect results. © 1999 John Wiley & Sons, Inc. J Polym Sci B: Polym Phys 37: 3097–3107, 1999  相似文献   

13.
An AB2 monomer, 1‐(2‐hydroxyethoxy)‐3,5‐bis‐(methoxymethyl)‐2,4,6‐trimethylbenzene, was synthesized from mesitol and melt‐polycondensed in the presence of an acid catalyst via a transetherification process at 145–150 °C to yield a soluble, moderately high molecular weight hyperbranched polyether. The degree of branching in the polymer was calculated to be 0.78 by a comparison of its NMR spectrum with that of an appropriately designed model compound. The weight‐average molecular weight of the hyperbranched polymer was determined to be 64,600 (weight‐average molecular weight/number‐average molecular weight = 5.2) by size exclusion chromatography (SEC) in CHCl3 with polystyrene standards. The origin of the broad molecular weight distribution, which could either be intrinsic to such hyperbranched structures or be due to structural heterogeneity, was further probed by the fractionation of the samples by SEC and by the subjection of each fraction to matrix‐assisted laser desorption/ionization time‐of‐flight mass spectral analysis. The mass spectral analysis suggested the presence of two primary types of species: one corresponding to the simple branched structure and the other to macrocyclics. Interestingly, from the relative intensities of the two peaks, it was apparent that cyclization became favorable at higher conversions in the melt transetherification process. © 2002 Wiley Periodicals, Inc. J Polym Sci Part A: Polym Chem 40: 4463–4476, 2002  相似文献   

14.
A computer program is described that can rapidly process low-resolution electrospray liquid chromatography/mass spectrometry (LC/MS) for peptides and proteins and assign molecular weights for observed components. The program first analyzes individual scans using a deconvolution algorithm similar to that previously described by Zhang and Marshall. Results for the entire run are then sorted by mass and those values found in adjacent scans are grouped together. The list of found components can also be compared to a user defined list of target molecular weight values making it easy to compare the results from different analyses. The program also has the capability to process a rolling average of scans that improves the performance when analyzing high molecular weight components. Other program features facilitate closer examination of selected spectra or regions of the chromatogram to check the MoWeD mass assignments. The utility of the program was demonstrated by the analysis of LC/MS data derived from a complex mixture of proteins derived from a bacterial whole cell lysate that had previously been analyzed manually. The MoWeD analysis was 30 times faster and provided a more comprehensive list of the components present.  相似文献   

15.
A low molecular weight predominantly polyolefin copolymer of isobutylene and para methylstyrene (IMS) was studied using matrix-assisted laser desorption/ionization (MALDI) mass spectrometry. Average composition information derived from the spectra was skewed to higher para methylstyrene (pMS) content as compared to that obtained using multiple NMR techniques, and drifted towards lower pMS incorporation at higher oligomer lengths. Although both observations were initially attributed in total to an inability to ionize the isobutylene component, comparison with subsequent field desorption (FD) mass spectrometry results gave similar values to that obtained via MALDI, even though FD ionizes oligomers not detected by MALDI. Instead, the compositional drift observed with MALDI roughly mirrored the mass distribution, and was determined to arise from a mass bias effect in oligomer ionization and detection. Composition with respect to oligomer mass was found to be relatively constant, although similarly higher in pMS content. Comparison of experimental peaks with a Bernoullian statistical model revealed severe overrepresentation of higher pMS composition oligomers with regard to the calculated distribution. This discrepancy is attributed to preferential ionization of oligomers with greater pMS content, and likely results in the observed difference between MALDI and NMR compositions.  相似文献   

16.
New approaches for the determination of the extent of symmetric and asymmetric band broadening (BB) in size exclusion chromatography (SEC) are presented. For this purpose raw data was simulated by starting with either a theoretical Poisson number chain length distribution (NCLD), or a log-normal weight chain length distribution (WCLD). Each distribution was first converted to a BB-free mass chromatogram, as typically obtained from a standard differential refractive index detector. Then, the broadened (or "measured") chromatograms were simulated by convoluting the BB-free chromatograms with a BB function, which was assumed to follow symmetrical (Gauss) as well as unsymmetrical (exponentially modified Gauss) function. A broad range of BB parameters (standard deviation, sigma(BB), and exponential decay, tau(BB)) was used for the simulations. The approaches are based on the determination of the points of inflection belonging to the peak of the broadened chromatogram, and closed as well as empirically derived equations connecting the peak width, its variance, and the parameters sigma(BB) and tau(BB). The developed methods are applicable for Poisson distributions well above a peak chain length of 100.  相似文献   

17.
The applicability of size exclusion chromatography (SEC) to analyze (upgraded) pyrolysis oil samples has been studied using model compounds, pyrolysis oils and hydrodeoxygenated pyrolysis oils. The assumptions needed for the conversion of the chromatogram to the Mw-distribution were validated. It was shown that the conversion of elution volume to molecular weight (based on polystyrene calibration curves) can introduce substantial errors in the prediction of the molecular weight. The conversion of RID response to W(log M) (as plotted on the y-axis of the Mw-distribution) is based on the assumption of a compound independent RID response factor and linear response to concentration. While the latter was shown to be true within the concentration range studied, the former was not true: the RID response factor depends on the type of (upgraded) pyrolysis oil. It was shown that within a single pyrolysis oil sample, the RID response for the low molecular weight fraction was a factor 3 lower than the high molecular weight fraction. Furthermore long term column fouling can influence SEC results that cannot be corrected with regular polystyrene recalibrations.Based on the results we recommend SEC not to be used as a quantitative method for characterization (upgraded) pyrolysis oil samples, but as a tool to compare (upgraded) pyrolysis oil samples, preferably prepared using incremental operating conditions and expected to have similar molecular composition. This work has further shown that (i) the ∫UVDdv/∫RIDdv ratio can be used as an indication of the sum of the relative aromaticity and conjugated double bond content for (upgraded) pyrolysis oil, and (ii) the negative peak area appearing in the low molecular weight part of the chromatogram can be used to estimate the water content of (upgraded) oil samples.  相似文献   

18.
SEC separates complex branched polymers by hydrodynamic volume, rather than by molecular weight or branching characteristics. Equations relating the response of different types of detectors are derived including band broadening, by defining a distribution function N′(M,Vh), the number of chains with molecular weight M and hydrodynamic volume Vh. While the true molecular weight distribution of complex polymers cannot be determined by SEC, irrespective of the detector used, the formalism enables multiple detection SEC data to be processed to both analyze the polymer sample and reveal mechanistic information about polymer synthesis. The formalism also shows how the true weight‐ and number‐average molecular weight, and , can be obtained from correct processing of the hydrodynamic volume distributions.

  相似文献   


19.
The products obtained on degradation of poly(m-acetoxystyrene) in vacuo are described. The effects of molecular weight and pyrolysis temperature are discussed and compared with those observed for polystyrene under similar conditions. The liquid products of pyrolysis were separated and identified by gas-liquid chromatography and mass spectrometry. Product analysis revealed significant differences between the products of degradation of the two polymers and mechanisms involving O-acetyl bond scission are proposed and discussed to account for this behaviour. Quantitative studies on the liquid fraction are also described and the behaviour compared with results obtained for polystyrene.  相似文献   

20.
Column systems for gel permeation chromatography are usually calibrated by eluting a series of sharp polymer fractions of known molecular weights and by correlating their elution volumes with molecular size or weight. A different method for calibration is proposed in which only one polymer sample, with a broad, well-characterized molecular weight distribution, is used. The cumulative distribution and the integrated, normalized GPC chromatogram are successively superimposed, and molecular weights and corresponding elution volumes are correlated. It is found that calibration curves obtained in this manner show a definite curvature. A possible explanation and correction for this behavior is given, based on the concentration dependence of elution volumes.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏