首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A rapid pioneering method has been developed to simultaneously determine residues of three pesticides (thiamethoxam, clothianidin, and metazachlor) in soil by ultrahigh performance liquid chromatography coupled to a mass spectrometry detector (quadrupole time‐of‐flight). An efficient extraction procedure (90–105% average analyte recoveries) has also been proposed, involving solid–liquid extraction by a mixture of water and methanol (60:40, v/v), centrifugation, and concentration. A chromatographic analysis of the compounds was achieved in 5.5 min by means of a core–shell technology based column (Kinetex® EVO C18, 50 × 2.1 mm, 1.7 μm, 100 Å). The mobile phase (0.3 mL/min, gradient elution mode) consisted of 0.1% v/v formic acid in water and 0.1% v/v formic acid in acetonitrile. The method was fully validated in terms of selectivity, detection and quantification limits, matrix effect, linearity, trueness, and precision. Low limits of detection and quantification were obtained, ranging from 0.2 to 3.0 μg/kg, which are similar to those published in previous studies, while the absence of a significant matrix effect allowed quantification of the pesticides with standard calibration curves. The proposed method was applied for an analysis of pesticides in several soil samples from experimental fields dedicated to oilseed rape cultivars.  相似文献   

2.
In this study, selenium species from Se containing proteins in mushrooms (Agaricus bisporus and Lentinula edodes) were investigated with size-exclusion liquid chromatography coupled to UV and inductively coupled plasma mass spectrometry (ICP-MS). Different protein extraction protocols were investigated. Variability of the fractionation patterns with three extraction media (0.1M NaOH, 30 mM Tris-HCl, and enzymatic digestions) was evaluated for both mushroom types. A 24 h Tris-HCl extraction followed by acetone addition was found to be optimal for protein precipitation. Presumably protein bound selenoamino acids were released using enzymes (proteinase K, protease XIV and trypsin). The selenium speciation of the proteolytic extract of the water soluble proteins fraction was carried out by using reversed-phase ion-pairing high performance liquid chromatography (RP-HPIPC) coupled on-line to ICP-MS for selenium specific detection. Selenocystine, selenomethionine, methylselenocysteine and inorganic selenium were established in both samples utilizing retention time standards and standard additions to the sample.  相似文献   

3.
A method of microwave-assisted extraction coupled with high-speed counter-current chromatography was established for separation and purification of isopimpinellin, pimpinellin and phellopterin from Toddalia asiatica (L.) Lam. The conditions of MAE including the extraction solvent, size of sample, solid/liquid ratio, extraction temperature and extraction time were optimized by a mono-factor test. That is, 2.0 g dried powder of T. asiatica (L.) Lam of 0.30-0.15 mm size was extracted with 20 mL (solid/liquid ratio of 1:10, g/mL) methanol under 50 °C for 1 min. The crude extract was separated and purified by high-speed counter-current chromatography with hexane-ethyl acetate-methanol-water (5:5:5.5:4.5, v/v/v/v) solvent system. 0.85 mg/g of isopimpinellin, 2.55 mg/g of pimpinellin and 0.95 mg/g of phellopterin were obtained from original sample in one-step within 240 min, the purity determined by high performance liquid chromatography was 95.0%, 99.1% and 96.4%, respectively. Their chemical structures were further identified by mass spectroscopy and nuclear magnetic resonance spectroscopy. The results demonstrated that microwave-assisted extraction coupled with high-speed counter-current chromatography was a feasible, economical and efficient technique for rapid extraction, separation and purification of effective compounds from natural products.  相似文献   

4.
Inductively coupled plasma mass spectrometry (ICP/MS) is utilized as a detector for several organotin species separated by high-performance liquid chromatography. Detection limits obtained by ICP/MS are 3 orders of magnitude lower than those obtained with inductively coupled plasma atomic emission spectrometry (ICP/AES) detection under the same chromatographic conditions. Chromatographic detection limits are higher than conventional solution nebulization for the same compound by a factor of 20. Ion-exchange chromatography yields linear response over 3 orders of magnitude, while ion pair chromatography gives a linear response of only 2 orders of magnitude as a result of poor resolution. The relative standard deviation for the injection of 20 ng of tin compounds is less than 10%.  相似文献   

5.
Thirteen polycyclic aromatic hydrocarbons have been determined in soy‐based nutraceutical products. First, an optimization of extraction procedure was performed, and a solid–liquid extraction assisted by sonication and a dilute and shoot procedure were compared, selecting the dilute and shoot approach for the extraction of target compounds, utilizing a mixture of acetone/n‐hexane (1:1 v/v) as extractant solvent. After this, a clean‐up step was needed bearing in mind the complexity of these matrices. Dispersive solid‐phase extraction, using a mixture of C18 and Zr‐Sep+ (25 mg/mL each) was used. The separation was achieved by gas chromatography and detection with triple quadrupole tandem mass spectrometry. For quantification purposes, matrix‐matched calibration was used. The validation was applied at three concentration levels (20, 100 and 250 μg/kg), obtaining recoveries between 70 and 120% and precision values equal to or lower than 23%. Limits of detection and quantification were below 8 and 20 μg/kg, respectively. The method was applied in 11 samples, detecting five polycyclic aromatic hydrocarbons at concentrations ranging from 4.1 to 18.5 μg/kg.  相似文献   

6.
The state-of-the-art of gas chromatography coupled with inductively coupled plasma mass spectrometry (GC-ICP MS) is comprehensively reviewed. Particular attention is given to the recent advances in ICP MS detection including: GC-ICP interface designs; low power plasmas; and alternative mass analyzers (time-of-flight, double-focussing single collector, double-focussing and collision cell single-focussing multicollectors). On the level of sample preparation for speciation analysis by GC-ICP MS, new derivatization reagents and advances in extraction techniques, such as capillary purge-and-trap, solid phase microextraction and stirbar solid phase extraction are discussed. The increasing role of organometallic species labeled with stable isotopes for the detection of sources of errors during sample preparation and for isotope dilution quantification is highlighted. Applications of GC-ICP MS to the analysis of real-world samples are summarized with a focus on the areas which particularly benefit from the high ICP MS detection sensitivity and tolerance to sample matrix.  相似文献   

7.
The usefulness and ease of utilizing supercritical fluid extraction (SFE) directly coupled to capillary gas chromatography (GC) as quantitative or qualitative analytical problem-solving tools will be demonstrated. As an alternative to conventional liquid solvent extractions, SFE presents itself as a means to achieve high extraction efficiencies of different compounds in complex solid matrices in very rapid tims frames. Moreover, SFE has an additional advantage of being able to achieve distinct extraction selectivities as a function of the solubilizing power of the supercritical fluid extracting phase. For on-line SFE/GC, the extraction effluent is directly transferred to the analytical chromatograph. On-line SFE/GC involves the decompression of pressurized extraction effluent directly into a heated, unmodified capillary split injection port of the GC. In this respect, SFE introduction into GC can be used as an alternative means of GC injection, comparable to such modes of injection as pyrolysis and thermal desorption. This paper will show applications of SFE/GC where mass spectrometric detection together with flame ionization detection was used for component identification from environmental, tobacco, and petroleum matrices.  相似文献   

8.
A method for the determination of organic chlorides in hydrogen for fuel cell vehicles by gas chromatography coupled with ion mobility spectrometry was established. Organic chlorides were separated by a non-polar gas chromatography column and detected in the negative ion mode of the ion mobility spectrometer. The effect of operating parameters of ion mobility spectrometer including drift gas flow rate and drift tube temperature on sensitivity and resolution were evaluated. Under the optimized conditions, the detection limits of seven organic chlorides were from 0.65 to 6.73 nmol/mol, which met the requirement of detection for the specification limit of 50 nmol/mol of total halogen impurities in hydrogen for fuel cell vehicles. Compared with gas chromatography-mass spectrometry, and gas chromatography coupled with electron capture detector under the same gas chromatography conditions, gas chromatography coupled with ion mobility spectrometry method demonstrated higher sensitivity for detection of organic chlorides under study. Based on the portability of the device and its detection capabilities, gas chromatography coupled with ion mobility spectrometry has the potential to perform online detection of impurities in hydrogen for fuel cell vehicles.  相似文献   

9.
A multiresidue method has been developed for determining pesticide residues in the tropical fruits kiwi, custard apple, and mango. The intended purpose of the method is for regulatory analyses of commodities for pesticides that have established maximum residue limits. A fast and simple extraction method with cyclohexane-ethyl acetate (1 + 1, v/v) and a high-speed homogenizer was optimized. Pressurized liquid extraction was evaluated as an alternative automated extraction technique. The pesticide residues were determined by using low-pressure gas chromatography coupled to tandem mass spectrometry. The proposed methodology was validated for each matrix. Pesticide recoveries ranged from 70 to 110%, with repeatability relative standard deviations of < or = 18% at spiking levels of 12 and 50 microg/kg. The limits of quantitation were in the range of 0.03-6.17 microg/kg, and the limits of detection were between 0.01 and 3.75 microg/kg. Mango can be selected as a representative matrix for calibration on the basis of the results of a potential matrix effect study. The method was successfully applied to the determination of pesticide residues in real samples in Spain.  相似文献   

10.
For the determination of trace residues of tetracycline antibiotics in fatty food samples, selective pressurized liquid extraction coupled with high‐performance liquid chromatography and tandem mass spectrometry was applied in this study. Copper(II) isonicotinate was first used as online cleanup adsorbent in the selective pressurized liquid extraction process. The adsorbent to sample ratio, extraction temperature, extraction time, and recycle times, etc. were optimized. The tetracyclines in food samples of pork, chicken meat, and clam meat were detected by liquid chromatography with tandem mass spectrometry. Tetracycline was found at levels of 0.32 and 0.53 μg/g and oxytetracycline was found at 0.14 and 0.21 μg/g in chicken meat and clam meat, respectively, while chlorotetracycline and deoxytetracycline were below the detection limit. The detection limit (S/N = 3) for these four tetracyclines were from 0.2 to 3.3 ng/g, the recoveries were from 75.8 to 110.5%, and relative standard deviations were from 5.5 to 13.6%. Copper(II) isonicotinate showed a higher purification capacity than other cleanup adsorbents for extraction of antibiotics in fatty food and the recovery showed predominance compared with a pressurized liquid extraction method without adsorbent. The study demonstrated that copper(II) isonicotinate would be a promising cleanup adsorbent in pressurized liquid extraction for the analysis of trace organic pollutants in complicated samples.  相似文献   

11.
This study presents a selective method of isolation of zearalenone (ZON) and its metabolite, α-zearalenol (α-ZOL), in neoplastically changed human tissue by accelerated solvent and ultrasonic extractions using a mixture of acetonitrile/water (84/16% v/v) as the extraction solvent. Extraction effectiveness was determined through the selection of parameters (composition of the solvent mixture, temperature, pressure, number of cycles) with tissue contamination at the level of nanograms per gram. The produced acetonitrile/water extracts were purified, and analytes were enriched in columns packed with homemade molecularly imprinted polymers. Purified extracts were determined by liquid chromatography (LC) coupled with different detection systems (diode array detection - DAD and mass spectrometry - MS) involving the Ascentis RP-Amide as a stationary phase and gradient elution. The combination of UE-MISPE-LC (ultrasonic extraction - molecularly imprinted solid-phase extraction - liquid chromatography) produced high (R ≈ 95–98%) and repeatable (RSD < 3%) recovery values for ZON and α-ZOL.  相似文献   

12.
A new screening procedure for 18 narcotics in urine for anti-doping purposes has been developed using liquid chromatography/triple quadrupole mass spectrometry (LC/MS). Electrospray ionization (ESI) was used as interface. Infusion experiments were performed for all substances to investigate their mass spectrometric behaviour in terms of selecting product specific ions. These product ions were then used to develop a tandem mass spectrometric method using selected reaction monitoring (SRM). For the LC/MS analysis, chromatography was performed on an octadecylsilane column. The total run time of the chromatographic method was 5.5 min. For the sample preparation prior to LC/MS analysis, the urine samples were liquid-liquid extracted at pH 9.5 after overnight enzymatic hydrolysis. Two extraction solvents were evaluated: dichloromethane/methanol 9/1 (v/v), which is currently used for the extraction of narcotics, and diethyl ether, used for the extraction of steroids. With diethyl ether the detection limits for all compounds ranged between 0.5 and 20 ng/mL and with the mixture containing dichloromethane the detection limits ranged between 0.5 and 10 ng/mL. Taking into account the minimum required performance limits of the World Anti-Doping Agency of 200 ng/mL for narcotics, diethyl ether can also be considered as extraction solvent for narcotics. Finally, the described method was applied to the analysis of urine samples previously found to contain narcotics by our routine gas chromatography/mass spectrometry (GC/MS) method.  相似文献   

13.
A method is proposed for the detection and confirmation of the presence of beta-blockers and their metabolites in fivefold diluted human urine samples by ultra performance liquid chromatography coupled with electrospay ionization tandem mass spectrometry. The limits of detection for most of compounds are 5–10 ng/mL. A substantial effect of ionization suppression was observed. The determination of metabolites and glucuronides of beta-blockers without additional derivatization and extraction is described for the first time.  相似文献   

14.
Atrasentan (A-147627) is an endothelin antagonist receptor being developed at Abbott Laboratories for the treatment of prostate cancer. A quick and sensitive method for the determination of atrasentan in human plasma has been developed and validated using high-performance liquid chromatography coupled with electrospray ionization tandem mass spectrometry. A dual-column, single mass spectrometer system is used to provide a reliable and routine means to increase sample throughput. The analytical method involves liquid-liquid extraction and internal standard (A-166790). The plasma samples and internal standard are acidified with 0.3 M hydrochloric acid prior to being extracted into 1:1 (v/v) hexanes--methyl t-butyl ether. The organic extract was evaporated to dryness using heated nitrogen stream and reconstituted with mobile phase. Atrasentan and internal standard were separated with no interference in a Zorbax SB-C(18) analytical column with 2.1 x 50 mm, 5 microm, and a Zorbax C(8) guard column using a mobile phase consisting of 50:50 (v:v) acetonitrile--0.05 M ammonium acetate, pH 4.5, at a flow rate of 0.30 mL/min to provide 4 min chromatograms. For a 250 microL plasma sample volume, the limit of quantitation was approximately 0.3 ng/mL. The calibration was linear from 0.30 to 98.0 ng/mL (r(2) > 0.995). A significant advantage of the method is the ability to employ parallel HPLC separations with detection by a single MS/MS system to provide sensitivity and selectivity sufficient to achieve robust analytical results with a lower limit of quantitation of 0.30 ng/mL and high throughput.  相似文献   

15.
This paper represents the first report of a liquid chromatography coupled to electrospray ionization mass spectrometry method for simultaneously analyzing resveratrol and piceid isomers (cis and trans) in beeswax. An efficient extraction procedure has been proposed (average analyte recoveries were between 89 and 95%); this involved a solid–liquid extraction using a mixture of ethanol and water (80:20, v/v) and a concentration step in a rotary evaporator. The separation of all the compounds was achieved using a C18 column and a mobile phase composed of ammonium formate 0.03 M in water and acetonitrile in gradient elution mode at a flow rate of 1 mL/min. The method was fully validated in terms of selectivity, limits of detection and quantification, linearity, precision, and accuracy. The limits of detection and quantification ranged from 1.0 to 1.7 and 3.5 to 5.5 μg/kg, respectively. Finally, the proposed method was applied to analyze beeswax samples collected from experimental and organic apiaries.  相似文献   

16.
This study developed an acid hydrolysis coupled to a solid-phase microextraction method employing a semi-microcolumn liquid chromatography system, instead of enzyme hydrolysis with solid-phase extraction for the pretreatment of human urine samples, to detect urinary 1-hydroxypyrene (1-OHP). The complete separation and detection of urinary 1-hydroxyprene was performed using a high-performance liquid-chromatography fluorescence detection system with an analytical C(18) semi-microcolumn, 60% (v/v) aqueous acetonitrile elution, and a lambda(ex/em) = 348/388 nm pair detection wavelength. Calibration graphs were linear with very good correlation coefficients (r = 0.9997), and the detection limit was 1.0 ng/L. These important parameters for acid hydrolysis and solid-phase microextraction were investigated. The total recovery was above 83% in acid hydrolysis with solid-phase microextraction. The proposed method provided a relatively simple, convenient, and practical procedure to determine the level of urinary 1-hydroxypyrene in biological samples, and was successfully applied to detect the urine of students.  相似文献   

17.
This paper describes the development of an accelerated solvent extraction methodology that is capable of simultaneously extracting organometallic species of As, Sn and Hg in a semi-automated manner. Accelerated solvent extraction (ASE) methods based on previous research on the separate extraction of organotin and -arsenic species in our laboratory were adapted for the co-extraction of six different species from an oyster tissue certified reference material (BCR 710). For the first time, the extraction of MeHg by this technique is also investigated. The proposed ASE conditions employed 50% acetic acid in methanol at a temperature of 100 degrees C with up to five consecutive extraction cycles of 3 minutes. Extraction efficiencies for organoarsenic species ranged from 80% (dimethylarsinic acid, DMA) to 99% for arsenobetaine (AsB). Species of toxicological interest, such as dibutyltin (DBT), tributyltin (TBT) and methylmercury (MeHg), were extracted with mean recoveries of 81, 84 and 76%, respectively. The extracted species were analysed by gas chromatography/inductively coupled plasma mass spectrometry (GC/ICPMS; DBT, TBT and MeHg) and liquid chromatography/inductively coupled plasma mass spectrometry (LC/ICPMS; MMA, DMA, AsB) after ethylation with sodium tetraethylborate or dilution with water, respectively. In addition to those species for which the extraction efficiency was assessed during this study, a further five arsenic species (arsenite, arsenate and three unidentified species), as well as monobutyltin (MBT) and mono-, di- and triphenyltin, could also be extracted from other matrices. The developed ASE method provides a significant improvement over many currently available routine monitoring methods for trace element speciation due to the fact that it is capable of extracting several species of toxicological interest simultaneously and quantitatively.  相似文献   

18.
The previously reported procedure for the determination of the total phthalate in fatty food involved the extraction of phthalates using chloroform/methanol followed by the removal of the solvents before alkaline hydrolysis requiring 20 h and derivatization of phthalic acid. In this study, a phase‐transfer catalyst (tetrabutylammonium chloride) was used in the liquid–liquid heterogeneous hydrolysis of phthalates in oil matrix shortening the reaction time to within 25 min. The resulting phthalic acid in the hydrolysate was extracted by a novel molecular complex based dispersive liquid–liquid microextraction method coupled with back‐extraction before high‐performance liquid chromatography coupled with photodiode array detection. Under the optimal experimental conditions, the linearity of the method was in the range of 0.5–12 nmol/g with the correlation coefficients (r) >0.997. The detection limit (S/N = 3) was 0.11 nmol/g. Intraday and interday repeatability values expressed as relative standard deviation were 3.9 and 7.1%, respectively. The recovery rates ranged from 82.4 to 99.0%. The developed method was successfully applied for the analysis of total phthalate in seven edible oils.  相似文献   

19.
This document is a glossary of terms for separations coupled to mass spectrometry. It covers gas chromatography/mass spectrometry, liquid chromatography/mass spectrometry, and supercritical fluid chromatography/mass spectrometry and the sample introduction, ionization, and data analysis methods used with these combined techniques.  相似文献   

20.
Highly selective separations can be achieved by utilizing different separation modes in a multi-dimensional (on-line coupled) chromatographic system. The application of such a system utilizing microcolumn liquid chromatography coupled on-line to capillary gas chromatography for the determination of 2-(1,1-dimethylethyl)-5-pyrimidinol, a pesticide metabolite, in various corn matrices at the ng g?1 level is described. A comparative quantitative study with conventional manual sample pretreatments followed by capillary gas chromatography-mass spectrometry indicated equivalence between the two techniques. The system offers the advantages of reduced sample handling steps and analysis time, high potential for automation and adequate sensitivity.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号