首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 42 毫秒
1.
Electroanalytical and chromatographic methodologies have been applied for the determination of pentachlorophenol (PCP) and some of its derivatives in real soil samples contaminated by industrial discharge. The analytes were extracted with hexane from soil samples collected at different points of the site and mixed to produce a representative sample. Square wave voltammetry (SWV) experiments were carried out on either a boron-doped diamond (BDD) electrode or a gold ultramicroelectrode (Au-UME) in an analyte composed by the Britton-Robinson (B-R) buffer at pH 5.5 with the direct addition of proper amounts of the extract. The voltammetric responses revealed an irreversible anodic peak at approximately 0.80 V vs. Ag/AgCl with a peak current showing a linear dependence on PCP concentration. This linear relationship yielded a detection limit (DL) of 2×10−8 mol l−1 (or 5.5 μg l−1) for the BDD electrode and 6.9×10−8 mol l−1 (18.4 μg l−1) for the Au-UME, while the independently measured HPLC detection limit was 1.1×10−8 mol l−1 (3.0 μg l−1). The application of electroanalytical and chromatographic methodologies in the analysis of soil extracts revealed, besides the PCP responses, signals for some related molecules such as o-tetrachlorobenzoquinone (o-chloranil), hexachlorobenzene and tetrachlorophenol. Recovering experiments for PCP showed a concentration of 27.5 mg kg−1 for the electroanalytical determinations and 26.8 mg kg−1 for the HPLC analysis, values exceedingly high if considering that the maximum residue limit established for natural waters by the Brazilian Environmental Agency is 10 μg l−1.  相似文献   

2.
The interfacial tensions of mixed α-dipalmitoylphosphatidylcholine (DPPC)/β-lactoglobulin layers at the chloroform/water interface have been measured by the pendent drop and drop volume techniques. In certain intervals, the adsorption kinetics of these mixed layers was strongly influenced by the concentrations of both protein and DPPC. However, at low protein concentration, Cβ-lactoglobulin=0.1 mg l−1, the adsorption rate of mixed interfacial layers was mainly controlled by the variation of the DPPC concentration. As Cβ-lactoglobulin was increased to 0.8 mg l−1, the interfacial activity was abruptly increased, and within the concentration range of CDPPC=10−4–10−5 mol l−1, the DPPC has very little effect on the whole adsorption process. In this case, the adsorption rate of mixed layers was mainly dominated by the protein adsorption. This phenomenon also happened as the protein concentration was further increased to 3.6 mg l−1. When CDPPC>3 · 10–5 mol l−1, the adsorption behaviour was very similar to that of the pure DPPC although the protein concentration was changed. The equilibrium interfacial tensions of the mixed layers are dramatically effected by the lipid as compared to the pure protein adsorption at the same concentration. It reveals the estimation of which composition of lipid and protein decreases the interfacial tension. The combination of Brewster angle microscopy (BAM) with a conventional LB trough was applied to investigate the morphology of the mixed DPPC/β-lactoglobulin layers at the air/water interface. The mixed insoluble monolayers were produced by spreading the lipid at the water surface and the protein adsorbed from the aqueous buffer subphase. The BAM images allow to visualise the protein penetration and distribution into the DPPC monolayer on compression of the complex film. It is shown that a homogeneous distribution of β-lactoglobulin in lipid layers preferentially happens in the liquid fluid state of the monolayer while the protein can be squeezed out at higher surface pressures.  相似文献   

3.
柴春彦  徐明刚  刘国艳 《分析化学》2006,34(12):1715-1719
为探索用电化学方法检测生物样品中氯霉素残留的高灵敏度技术,本实验研究了阳离子表面活性剂十六烷基三甲基溴化铵(CTMAB)对氯霉素在玻碳电极上伏安行为的影响,实验结果表明,以0.02 mol/L高氯酸为支持电解质,在0.40~-0.60 V的范围内进行伏安扫描时,2×10-5mol/L CTMAB能显著提高氯霉素在-0.41 V处的还原峰电流。利用这种改进的电化学方法检测氯霉素的线性范围为0.0026~8 mg/L,检出限达到0.83μg/L。研究了缓冲液种类及其酸碱度及其它表面离子活性剂等对测试氯霉素的影响。  相似文献   

4.
毛细管电泳-安培法测定复方磺胺甲噁唑片中的有效成分   总被引:1,自引:0,他引:1  
采用毛细管电泳-安培法(CE-AD)同时分离测定了磺胺甲噁唑(sulfamethoxazole,SMZ)、磺胺嘧啶(sulfadiazine,SD)和抗菌增效剂甲氧苄胺嘧啶(trimethoprim,TMP)3种常用磺胺类抗菌药物成分,考察了实验参数对分离、检测体系的影响。在优化实验条件下,以300μm碳圆盘电极作为工作电极,检测电位为1050mV(vs.SCE),在Na2B4O7(13mmol/L)-KH2PO4(18mmol/L)(pH5.8)的缓冲溶液中,分离电压18kV,进样6s,3组分在14min内可实现基线分离。上述3组分浓度分别在5×10-4~5×10-2、5×10-4~0.1和5×10-4~5×10-2g/L范围内与其峰电流强度呈线性关系,检出限达5.1×10-5~8.0×10-5g/L(S/N=3)。该方法已成功应用于复方磺胺甲噁唑片中抗菌活性成分的含量测定,结果令人满意。  相似文献   

5.
This work presents alternatives for Fe and Co determination in pharmaceutical samples using flow analysis. The first procedure describes Fe extraction in mineral/vitamin complexes. The best conditions were reached when HNO3 concentration and volume, sample mass and shaking time were 1.0 mol l−1, 5 ml, 25 mg and 10 min. Three mineral/vitamin complexes of known concentrations (ranging from 12 to 32 g kg−1) were analyzed (10 authentic replicates for each) and recoveries of around 100% were obtained when compared with a well-established mineralization procedure employing concentrated HNO3 and H2O2 (30% w/v). The second work part shows the employment of Tiron and H2O2 reaction for Co determination in a drug for inappetence. The results (352±18.7 mg kg−1) were compared with those using Electrothermal Atomic Absorption Spectrometry—ETAAS (346±15.7 mg kg−1). The proposed method showed detection and quantification limits of 0.20 and 0.70 μg l−1, respectively. Both procedures for Fe and Co determination presented time, reagent and effort reduction.  相似文献   

6.
Specific determination for IO3 and I in ground water using high performance liquid chromatography-inductively coupled plasma mass spectrometry (HPLC-ICPMS) is described. Chromatographic separations were carried out using an ICS-A23 column. Iodine species were quantitatively eluted with 0.03 M ammonium carbonate. Under the Shield Torch high sensitive mode, the method detection limits for IO3 and I with injection of 1 ml were 0.035 μg l−1 and 0.025 μg l−1, respectively. The method was applied to the determination of iodide and iodate in ground water. However, the signal response difference between iodate and iodide was observed by both the HPLC-ICP-MS system and the ICP-MS system. Also, the same signal response difference was also observed in other laboratories. It was reported that the signal response and stability of iodine species vary with their solution medium. The instability of IO3 – and I – was controlled by using KOH as their solution storing media. The IO3 and I peak area ratios by HPLC-ICP-MS measurement were still close to 1:1 when the mixed standard solution was stored in the 0.01% KOH medium for 5 days.  相似文献   

7.
An automated on-line pre-reduction of arsenate, monomethylarsonate (MMA) and dimethylarsinate (DMA) using flow injection hydride generation atomic absorption spectrometry (FI-HGAAS) is feasible. The kinetics of pre-reduction and complexation depend strongly on the concentration of -cysteine and on the temperature in the following increasing order: inorganic As(V)<DMA<MMA. Arsenate is pre-reduced/complexed within less than 50 s at 70–100°C compared to 1 h at room temperature, while MMA and DMA require 1.5–2 min at 70–100°C and up to 1–2 h at room temperature. The characteristic masses and concentrations for 100 μl injections are 0.01 ng and 0.1 μg l−1 in integrated absorbance and 0.2 ng and 2 μg l−1 in peak height measurements, and the limits of detection are ca. 0.5 ng and 5 μg l−1, respectively. In a high-performance liquid chromatography (HPLC)–HGAAS system, the -cysteine complexes of inorganic As(III), MMA and DMA are best separated within 7 min by HPLC on a strongly acidic cation exchange column such as Spherisorb S SCX 120×4 mm (5 μm) with a mobile phase containing 12 mmol l−1 phosphate buffer (KH2PO4/H3PO4)–2.5 mmol l−1 -cysteine, pH 3.3–3.5. Upon dilution to -cysteine levels below 10 mmol l−1, which are compatible with HPLC separations, the DMA–cysteine complex is unstable on storage. No baseline separations are possible with anion exchange and reverse phase C18 HPLC columns. The limits of detection with 50 μl injections in peak area mode are ca. 0.5 ng and 10 μg l−1, respectively.  相似文献   

8.
An automatic flow procedure for the determination of glycerol in wines by employing a flow system based on multicommutation and enzymatic reaction is described. Glycerol dehydrogenase was immobilized on aminopropyl glass beads and packed into a column that was coupled to the flow system. The NADH produced by the enzymatic reaction was monitored by spectrophotometry at 340 nm and its radiation absorption presented a relationship with glycerol concentration. The system manifold comprised a set of three-way solenoid valves controlled by a microcomputer, which was furnished with electronic interfaces and runs a software that was designed to carry out on-line sample dilution, reagent addition, and data acquisition. The procedure allows the determination of glycerol in wine samples without any prior pretreatment. The procedure presented as profitable features a linear response range between 2.0 and 10.0 g l−1 glycerol (R=0.998), a detection limit of 0.006 g l−1 glycerol, a relative standard deviation of 1.8% (n=14) for a typical wine sample presenting 5.3 g l−1 glycerol, a sampling throughput of 33 determinations per hour, and a NAD+ consumption of 0.8 mg per determination. The results were compared with those obtained using a reference method and no significant difference at 90% confidence level was observed.  相似文献   

9.
The electrochemical behavior of the interaction of furazolidone (Fu) with bovine serum albumin (BSA) was investigated by cyclic voltammetry and differential pulse voltammetry at a glassy carbon electrode. Fu shows an irreversible reduction at − 0.34 V in pH 4.0 Britton–Robinson buffer (B–R) buffer–10% DMF solution. After the addition of BSA into the Fu solution, the reductive peak currents decreased without any significant shift of the peak potential and the appearance of new peaks. The electrochemical parameters of the interaction system were calculated in the absence and presence of BSA. This electrochemical method was further applied to the determination of BSA samples and the results were in good agreement with the traditional cellulose acetate electrophoresis. The linear dynamic range was between 10.0 and 80.0 mg l− 1. The detection limit was 7.6 mg l− 1 and the recoveries were obtained from 97.0% to 104.0%.  相似文献   

10.
The use of rice husks as an alternative adsorbent in an on-line preconcentration system for Cd (II) and Pb (II) determination by flame atomic absorption spectrometry (FAAS) is described. The potential of rice husks as a natural adsorbent was evaluated as a material modified with 0.75 mol l−1 NaOH solution and in the unmodified form. For this task, several techniques such as spectroscopy and thermogravimetry were used for elucidation of possible functional groups responsible for the uptake of Cd (II) and Pb (II). Furthermore, based on adsorption studies and adsorption isotherms applied to the Langmüir model, it was possible to verify that modified rice husks present a higher adsorption capacity for both metals. After establishing this material as a promising natural adsorbent, it was used for on-line preconcentration of Cd (II) and Pb (II) metals. The multivariate optimisation of chemical and flow variables was performed by using a full factorial design (24) including the following factors: preconcentration time, preconcentration flow rate, concentration and volume of eluent. The optimum pH values used for on-line preconcentration were taken from prior univariate experiments. Under optimised conditions for Cd (II) determination (4 min of preconcentration at a 6 ml min−1 preconcentration flow rate, in which comprises 24 ml of preconcentration volume, 200 μl elution volume and 1.0 mol l−1 HNO3 solution as eluent), the system achieved a detection limit of 1.14 μg l−1 and an enrichment factor of 72.4. Similar conditions were used for Pb (II) determination (4 min of preconcentration, 6 ml min−1 preconcentration flow rate, 300 μl elution volume and 1.0 mol l−1 HNO3 solution as eluent) from which a detection limit of 14.1 μg l−1 and enrichment factor of 46.0 were achieved. Also, rice husks have been shown to be a homogeneous and stable adsorbent in which more than 100 preconcentration/elution cycles provide a relative standard deviation (RSD) of less than 6.0% on the analytical signal. The satisfactory accuracy of the method developed was obtained by using spiked water samples (mineral water and lake water) and spiked red wine samples. These values were confirmed by electrothermal atomic absorption spectrometry (ETAAS). The certified reference material [pig kidney (CRM 186)] and the reference material [beech leaves (CRM 100)] were also used.  相似文献   

11.
Sun X  Xia K  Liu B 《Talanta》2008,76(4):747-751
This paper details the fabrication of indole (ID) self-assembled multilayers (SAMs) and fluorescence interfacial sensing for organophosphorus (OP) pesticides. Quartz/APES/AuNP/l-Cys/ID film was constructed on l-cysteine modified Quartz/APES/AuNP surface via electrostatic attraction between ID and l-cysteine. Cyclic voltammetry indicates that ID is immobilized successfully on the gold surface. Fluorescence of the Quartz/APES/AuNP/l-Cys/ID film shows sensitive response toward OPs. The fluorescent sensing conditions of the SAMs are optimized that allow linear fluorescence response for methylparathion and monocrotophos over 5.97 × 10−7 to 3.51 × 10−6 g L−1 and 3.98 × 10−6 to 3.47 × 10−5 g L−1, with detection limit of 6.1 × 10−8 gL−1 and 3.28 × 10−6 gL−1, respectively. Compared to bulk phase detection, interfacial fluorescence sensing based on the SAMs technology shows higher sensitivity by at least 2 order of magnitude.  相似文献   

12.
The present paper proposes an on-line pre-concentration procedure for lead determination in drinking water and saline waste from oil refinery by flame atomic absorption spectrometry (FAAS). It is based on the sorption of lead (II) ions in a minicolumn of polyurethane foam loaded with 4-(2-pyridylazo)-resorcinol (PAR) reagent. The optimization step was performed using Doehlert matrix involving the variables: sampling flow rate (SR), buffer concentration (BC), pH and eluent concentration (EC). The validation process was performed considering the parameters: linearity and other characteristics of the calibration curve, analytical features of on-line system, precision, robustness, effect of other ions in the pre-concentration system and accuracy. Using the established experimental conditions, the procedure allows lead determination with detection limit (3δ/S) of 0.4 μg l−1, quantification limit (10δ/S) of 1.4 μg l−1, and a precision, calculated as relative standard deviation (RSD) of 5.7 (n=8) and 2.1% (n=8) for lead concentration of 5 and 50 μg l−1, respectively. The pre-concentration factor (PF) considering the ratio among the slopes of the analytical curves with and without pre-concentration is 51. The achieved recovery for lead determination in presence of several cations demonstrated that this procedure could be applied for analysis of water samples. The accuracy was confirmed by analysis of the standard reference material NIST 1640 Trace elements in natural water. The sorption process was characterized by the Langmuir isotherm. The method was applied for lead determination in drinking water collected in Salvador City, Brazil and in saline effluent samples from oil refinery. The lead content for 16 samples of drinking water analyzed varied from 0.77 to 6.98 μg l−1.  相似文献   

13.
The redox reaction of 5-fluorouracil (FU) at a hanging mercury drop electrode (HMDE) is studied by means of square-wave voltammetry (SWV). It is demonstrated that the redox reaction proceeds according to the scheme: L2−(aq)L2−(ads)+Hg(l)HgL(s)+2e, which involves both chemisorption of FU on the electrode surface and creation of a sparingly soluble compound with the electrode material. The overall response exhibits properties of a surface process in which both the reactant and the product of the redox reaction are immobilized on the electrode surface. The square-wave voltammetric response of FU possesses features typical of surface confined processes such as ‘split SW peaks’ and a ‘quasi-reversible maximum’. The proposed electrode mechanism is studied theoretically. The numerically calculated response under conditions of SWV is in qualitative agreement with the experimental data. Comparing the theoretical and the experimental data, the kinetic parameters of the redox reaction investigated are estimated. The standard rate constant appears to be within the interval 54≤ks/s−1≤108, the adsorption constant is K=10 cm−1, and the transfer coefficient is α=0.54±0.01. The effect of the Cu(II) ions on the adsorptive SWV response of FU is discussed from an analytical point of view. It is demonstrated that SWV is a particularly appealing technique, which enables determination of FU at an ultra-trace concentration level. A linear calibration plot was established at 10−11 mol l−1 concentration level with a correlation coefficient of R2=0.992. The detection limit is 7.7×10−12 mol l−1. The reproducibility of the results in terms of the relative standard deviation ranges from 0.9 to 3.2%.  相似文献   

14.
龚福春  何德肆  曹忠  谭淑珍  谭亚非 《分析化学》2007,35(12):1783-1786
一种纯天然产物白藜芦醇用作辣根过氧化物酶(HRP)底物。对其化学性质的研究证实,白藜芦醇在空气中较稳定,对HRP、H2O2的电化学响应性能优于传统HRP底物,对人体无毒害。白藜芦醇在HRP催化下可被H2O2氧化成醌,产物醌在电极上于-376 mV处可被还原,其电流的大小与HRP的浓试在一定浓度范围内呈线性相关。将兔布氏杆菌抗原包埋在石墨-石蜡基质中制备了测定兔布氏杆菌抗体的电化学酶联免疫传感器,该传感器测定兔布氏杆菌抗体的线性范围为3×10-4~1.65×10-2g/L;检出限为1×10-4g/L;RSD为4.6%。本方法制备免疫传感器的电化学性能稳定,抗原活性保持良好。  相似文献   

15.
A flow injection on-line coprecipitation preconcentration system with diethyldithiocarbamate (DDTC) chelate of copper used as the coprecipitate carrier was coupled with flame atomic absorption spectrometry (FAAS) for the determination of trace silver. Silver was on-line coprecipitated with DDTC-Cu(II) in 0.5 moL · L−1HCl, and the precipitate was collected in a knotted reactor. The precipitate was then dissolved by isobutyl methyl ketone and transported directly into the nebulizer–burner system of a flame atomic absorption spectrometer. A detection limit (3ς) of 0.6 μg · L−1was achieved for a loading period of 30 s, a relative standard derivation of 2.0% was obtained for 11 determinations of 20 μg · L−1Ag(I). Interference-free levels were 10 mg · L−1for Cd2+, 50 mg · L−1for Cu2+, 50 mg · L−1for Mn2+, 25 mg · L−1for Ni2+, 100 mg · L−1for Pb2+, 50 mg · L−1for Zn2+, 500 mg · L−1for Fe3+, and 2000 mg · L−1for Fe2+reduced from Fe3+by ascorbic acid. The developed method has been successfully applied to the determination of trace amount of silver in geological samples.  相似文献   

16.
A screen-printed carbon electrode modified with both HRP and LOD (SPCE–HRP/LOD) has been developed for the determination of l-lactate concentration in real samples. The resulting SPCE–HRP/LOD was prepared in a one-step procedure, and was then optimised as an amperometric biosensor operating at [0, −100] mV versus Ag/AgCl for l-lactate determination in flow injection mode. A significant improvement in the reproducibility (coefficient variation of about 10%) of the preparation of the biosensors was obtained when graphite powder was modified with LOD in the presence of HRP previously oxidised by periodate ion (IO4). Optimisation studies were performed by examining the effects of LOD loading, periodation step and rate of the binder on analytical performances of SPCE–HRP/LOD. The sensitivity of the optimised SPCE–HRP/LOD to l-lactate was 0.84 nA L μmol−1 in a detection range between 10 and 180 μMol. The possibility of using the developed biosensor to determine l-lactate concentrations in various dairy products was also evaluated.  相似文献   

17.
The voltammetric behavior of the LMF-Mg(II) complex with DNA at a mercury electrode is reported for the first time. In NH3–NH4Cl buffer (pH=9.10), the adsorption phenomena of the LMF–Mg(II) complex were observed by linear sweep voltammetry. The mechanism of the electrode reaction was found to be a reduction of LMF in the complex, and the composition of the LMF–Mg(II) complex is 2:1. In the presence of calf thymus DNA (ctDNA), the peak current of LMF–Mg(II) complex decreased considerably, and a new well-defined adsorptive reduction peak appeared at −1.63 V (vs. SCE). The electrochemical kinetic parameters and the binding number of LMF–Mg(II) with ctDNA were also obtained. Moreover, the new peak currents of LMF–Mg(II)–DNA system increased linearly correlated to the concentration of DNA in the 4.00×10−7–2.60×10−6 g ml−1 range when the concentrations of LMF–Mg(II) complex was fixed at 5.00×10−6 mol l−1, with the detection limits of 2.33×10−7 g ml−1. An electrostatic interaction was suggested by electrochemical method.  相似文献   

18.
Xiong C  He M  Hu B 《Talanta》2008,76(4):772-779
A new, simple, and selective method has been presented for the separation and preconcentration of inorganic arsenic (As(III)/As(V)) and selenium (Se(IV)/Se(VI)) species by a microcolumn on-line coupled with inductively coupled plasma-optical emission spectrometry (ICP-OES). Trace amounts of As(V) and Se(VI) species were separated and preconcentrated from total As and Se at desired pH values by a conical microcolumn packed with cetyltrimethylammonium bromide (CTAB)-modified alkyl silica sorbent in the absence of chelating reagent. The species adsorbed by CTAB-modified alkyl silica sorbent were quantitatively desorbed with 0.10 ml of 1.0 mol l−1 HNO3. Total inorganic arsenic and selenium were similarly extracted after oxidation of As(III) and Se(IV) to As(V) and Se(VI) with KMnO4 (50.0 μmol l−1). The assay of As(III) and Se(IV) were based on subtracting As(V) and Se(VI) from total As and total Se, respectively. All parameters affecting the separation/preconcentration of As(V) and Se(VI) including pH, sample flow rate and volume, eluent solution and volume have been studied. With a sample volume of 3.0 ml, the sample throughput was 24 h−1 and the enrichment factors for As(V) and Se(VI) were 26.7 and 27.6, respectively. The limits of detection (LODs) were 0.15 μg l−1 for As(V) and 0.10 μg l−1 for Se(VI). The relative standard deviations (RSDs) for nine replicate determinations at 5.0 μg l−1 level of As(V) and Se(VI) were 4.0% and 3.6%, respectively. The calibration graphs of the method for As(V) and Se(VI) were linear in the range of 0.5–1000.0 μg l−1 with a correlation coefficient of 0.9936 and 0.9992, respectively. The developed method was successfully applied to the speciation analysis of inorganic arsenic and selenium in natural water samples with satisfactory results.  相似文献   

19.
A fast and sensitive high performance liquid chromatography method for quantitative determination of rosiglitazone in human plasma has been developed. The extraction from plasma was performed using solid-phase extraction (SPE) on C4 silica (100 mg) disposable extraction cartridges (DEC). The separation of rosiglitazone and two metabolites was achieved on a Phenomenex® Synergi 4 µm MAX-RP (150 × 4.6 mm) column, protected by a guard column. The mobile phase was 0.01 M ammonium acetate, pH 7.0 - acetonitrile (65:35, v/v). (3S)-3-OH-quinidine was used as internal standard. The analytes were detected using fluorescence detection. The method was validated. The limit of quantitation was 1 ng mL−1 and the detection limit was 0.25 ng mL−1 for rosiglitazone in human plasma. The recovery was 90% for rosiglitazone. Linearity was observed over a range of 1-1000 ng mL−1 (r2=0.9959). The intra- and inter-day precision (C.V.) did not exceed 8.7 %. Applicability of the method was demonstrated by a clinical pharmacokinetic study. A healthy volunteer received in two separate phases 4 mg and 8 mg rosiglitazone maleate as a single oral dose. Plasma concentrations were measured for 24 h in both phases.  相似文献   

20.
A multivariate curve resolution method by alternating least-squares (MCR-ALS) is applied to differential pulse voltammograms measured on the Cd(II)+(γ-Glu---Cys)2Gly system as a model of metal–phytochelatin interactions at concentrations of both components in the range 10−7–10−5 mol l−1. The course of complexation is different when peptide is titrated with metal from that when metal is titrated with peptide. The combined analysis of both matrices from titrations of peptide with metal and of metal with peptide allowed the resolution of the system. The analysis of the resulting pure voltammograms and concentration profiles of the resolved components suggested the presence of four different types of bound Cd(II) and made possible the formulation of a complexation model.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号