共查询到20条相似文献,搜索用时 116 毫秒
1.
建立了动物源食品中喹喔啉类药物代谢残留标识物3-甲基喹喔啉-2-羧酸和喹喔啉-2-羧酸的高效液相色谱-串联质谱检测方法。样品在酸性环境水解,经乙酸乙酯、磷酸盐缓冲液依次提取,Oasis MAX固相萃取小柱净化,用Waters Xterra MS C18柱(150 mm×2.1 mm, 5 μm)分离,以甲醇-0.2%甲酸为流动相梯度洗脱,采用多反应监测(MRM)正离子模式检测,内标法定量。各物质在1.0~20.0 μg/L范围内线性关系良好,相关系数均不低于0.9996; 3-甲基喹喔啉-2-羧酸和喹喔啉-2-羧酸在0.1、0.2、1.0 μg/kg加标水平的回收率为62.4%~118%,相对标准偏差为1.48%~28.1%;定量限(以信噪比≥10计)为0.1 μg/kg。该方法简单、灵敏、稳定,可满足猪肉、猪肝、鸡肉、鸡肝、鱼、虾等动物源食品中3-甲基喹喔啉-2-羧酸和喹喔啉-2-羧酸残留的检测与确证需要。 相似文献
2.
建立了高效液相色谱-串联质谱同时定量和确证猪肉中3-甲基喹喔啉-2-羧酸(MQCA)残留量的检测方法。试样用0.3 mol/L盐酸溶液水解提取,加入乙腈和乙酸乙酯萃取,再用0.1 mol/L氢氧化钠溶液反萃取,阴离子交换固相萃取柱净化,经Agilent Eclipse Plus C18柱(50 mm×3.0 mm,1.8 μm)分离,采用液相色谱-串联质谱仪检测,基质匹配添加标准曲线定量。MQCA在1.0~50 μg/L范围内线性相关系数大于0.99,在0.5、1.0、5.0 μg/kg加标水平下其回收率为90.5%~119.6%,相对标准偏差为3.14%~4.22%。方法可用于猪肉中MQCA残留量的快速定量和确证检测。 相似文献
3.
以猪肉、猪肝、猪肾、胖头鱼、对虾和蟹为试验材料,建立了喹乙醇(OLA)的残留标示物3-甲基喹恶啉-2-羧酸(MQCA)残留的超高效液相色谱-串联质谱(UPLC-MS/MS)检测方法。采用0.2 mol/L盐酸提取可食性组织中的分析物,经C18固相萃取小柱净化、35 ℃氮气吹干及含0.1%(v/v)甲酸的乙腈溶解后,采用超高效液相色谱分离,串联质谱法确证和定量分析。质谱检测采取正离子多反应监测模式,外标法定量。结果表明: MQCA在2~500 μg/L范围内呈良好的线性关系,各组织中的相关系数(r2)均大于0.990;猪肉、猪肝、猪肾、鱼、对虾和蟹中MQCA的检出限依次为0.90、1.51、0.94、1.04、1.62和1.80 μg/kg,定量限依次为3.00、5.02、3.13、3.46、5.40、6.00 μg/kg。从3~100 μg/kg的添加浓度的检测结果可以看出,MQCA的平均回收率均在73.6%与89.0%之间,日内相对标准偏差(RSD, n=5)在15%以下,日间RSD(n=3)为20%以下。该方法的灵敏度、准确度和精密度均符合兽药残留分析技术的要求,适用于动物组织中MQCA残留的定量分析和确证检测。 相似文献
4.
5.
固相萃取-高效液相色谱法测定猪组织中的头孢喹诺 总被引:2,自引:0,他引:2
本文建立了固相萃取-高效液相色谱法测定猪组织中头孢喹诺的方法。组织样品用磷酸盐缓冲液、异辛烷和乙腈提取,40℃旋转蒸发至近干,C18固相萃取小柱净化后注入高效液相色谱仪分析。采用Inertsil C18色谱柱(250×4.6 mm,5μm),以磷酸盐缓冲液-乙腈(体积比为80∶20)为流动相,于270 nm波长处检测。肌肉、脂肪、肝脏和肾脏样品中头孢喹诺的检测限分别为5、10、15、30μg/kg。在20~2 000μg/kg添加水平内,平均回收率为55.7%~79.4%,相对标准偏差为3.3%~5.7%。本方法可用于猪组织中头孢喹诺残留的检测。 相似文献
6.
本文使用自制的3-溴甲基喹喔啉-2-甲酸乙酯(6)为反应物,经一锅连续的Williamson反应/酯基水解反应过程,简便有效地合成一系列结构新型的3-芳氧甲基喹喔啉-2-羧酸类化合物(4a-l)。然后选用五种菌株为研究对象,进行了初步的体外抗菌活性实验,结果表明含有叔丁基和卤素取代的化合物4j, 4k和4l对革兰氏阳性菌金黄色葡萄球菌和枯草芽孢杆菌表现出很好的抑制活性,其中化合物4j的活性比参考药物S环丙沙星还要高,其MIC值分别为15.625 和7.8125 μg/mL。 相似文献
7.
8.
高效液相色谱法测定动物组织中磺胺类残留量 总被引:9,自引:0,他引:9
磺胺类合成抗菌药是一类抑制核酸合成的抗菌药,可分为全身应用、肠道应用和局部外用等3类。磺胺类药物作为预防与治疗用药而广泛地用于食用动物中。但有文献报道该类药物可能使小鼠致癌。同时,由于该类药品可残留在动物组织中,食用含有磺胺类药物残留的动物源性食品,可引起过敏、尿和造血紊乱等不良反应。目前中国、欧盟、美国、日本、韩国等国家均将磺胺类药物列为动物饲养过程中限制使用的药物,其最大残余限量一般为50~100μg/kg。本实验采用样品加入乙腈提取后,用乙腈饱和的正己烷去除脂肪和杂质,通过优化色谱条件,进行7种磺胺类药物多残留的同时测定。结果表明,本方法简便,快速,结果准确,适合大批量样品的测定。 相似文献
9.
建立了水产品中甲基睾丸酮残留的分散固相萃取-高效液相色谱检测方法。样品加入无水硫酸镁后乙酸乙酯均质提取,提取液经中性氧化铝粉分散固相萃取、净化后上机检测。甲基睾丸酮的检出限为8μg/kg,在质量浓度为10~10 000ng/mL的范围内线性良好,相关系数为0.9999。对罗非鱼、草鱼、对虾及甲鱼进行3个水平(30,50,100μg/kg)的加标回收实验,回收率为84.6%~106%,相对标准偏差为1.77%~4.27%。方法适用于水产品中甲基睾丸酮残留的快速分析检测。 相似文献
10.
采用高效液相色谱法测定咪唑中2-甲基咪唑和4-甲基咪唑的含量。采用XDB C18色谱柱为分离柱,以pH 3.5的0.05mol·L-1磷酸二氢钾缓冲溶液与甲醇以体积比95比5组成的混合溶液为流动相,流量为1.0mL·min-1,在波长210nm处进行二极管阵列检测。2-甲基咪唑和4-甲基咪唑均在0.10~25.0mg·L-1范围内与其峰面积呈线性关系,检出限(3S/N)分别为20,40mg·kg-1。在1.00,5.00,20.0mg·L-1 3个浓度水平进行加标回收试验,回收率在89.0%~103%之间,测定值的相对标准偏差(n=7)在0.58%~3.0%之间。 相似文献
11.
《Analytical letters》2012,45(4):606-615
A time-resolved fluoroimmunoassay for the specific determination of methyl-3-quinoxaline-2-carboxylic acid in animal tissues, a marker residue of olaquindox, was developed. The IC50 of the assay was found to be 1.46 ± 0.19 ng/mL of methyl-3-quinoxaline-2-carboxylic acid in phosphate-buffered saline samples and the detection limit was 0.16 ± 0.03 ng/mL. For porcine liver and muscle samples spiked with 5, 10, and 15 ng/g, the recovery ranges were 95.7–112.3% and 98.5–116.2% and the coefficients of variation were 9.3–11.5% and 8.9–14.2%, respectively. The time-resolved fluoroimmunoassay results correlated well with high performance liquid chromatography results (correlation coefficients of 0.991 for liver and 0.988 for muscle). This study suggests that this method is simple, fast, and sensitive for the high-throughput determination of methyl-3-quinoxaline-2-carboxylic acid in animal tissues. 相似文献
12.
13.
14.
15.
高效液相色谱法测定动物组织样品中黄曲霉毒素的残留量 总被引:1,自引:0,他引:1
采用免疫亲合技术,对动物肝脏和肌肉中黄曲霉毒素残留进行了提取和纯化处理,建立了一种快速、灵敏、简便的测定动物组织中黄曲霉毒素B1、B2、G1、G2的高效液相色谱方法。用反相HPLC分离,柱后光化学衍生,荧光检测器测定黄曲霉毒素含量,保留时间定性,峰面积定量,测定了样品和标准样。结果表明,4种毒素可在10min内完成分离;线性范围为15~1500pg;线性回归系数大于0.9998。用本方法对动物肝脏和肌肉样品进行了加标回收实验,4种黄曲霉毒素的平均回收率为68.71%~83.42%;相对标准偏差为3.51%~7.40%;检出限均达到2.65pg。 相似文献
16.
用苯胺对四氢噻唑-2-硫酮-4-羧酸(TTCA)进行柱前衍生,将其衍生物在手性固定相上拆分,通过二极管阵列紫外检测器和在线旋光检测仪对其衍生物进行检测,建立了一种拆分TTCA消旋体、测定TTCA光学纯度的新方法。以正己烷和乙醇或异丙醇为流动相,在DNB-Leucine手性固定相上对TTCA衍生物进行了拆分,并考察了流动相组成和柱温对其衍生物分离的影响,获得较优分析条件,分离因子大于1.2。非手性试剂苯胺柱前衍生化法测定(R)-TTCA的光学纯度与旋光度方法比较,结果一致,相对偏差小于1.34%。 相似文献
17.
动物组织中阿莫西林残留的液相色谱分析方法研究 总被引:11,自引:0,他引:11
建立了反相高效液相色谱分析鸡肉、猪肉、猪皮、猪脂肪等动物组织样品中阿莫西林残留量的方法。对4种动物组织样品采用磷酸盐缓冲溶液提取、三氯乙酸沉淀蛋白、固相萃取净化和富集、1,2,4-三唑-氯化汞衍生化。研究了样品在C18柱上的保留行为和阿莫西林的衍生化条件。衍生物采用高效液相色谱法分离,外标法定量分析,标准曲线的线性相关系数为0.9997,线性范围为8.6-860 μg/L。动物组织样品中阿莫西林的加标回收率为70.9%-86.8%,相对标准偏差为3.2%-16.4%,最低检出限低于10 μg/kg。该分析 相似文献
18.
建立了人体尿液中蝶呤-6-羧酸的高效液相色谱-紫外分析新方法. 运用Lichrospher C18柱(250×4.6 mm,5 μm),甲醇-水(70∶30,V/V)为流动相,流速为0.4 mL/min,可较好地将尿液中蝶呤-6-羧酸与其它共存干扰物质分离.在355 nm检测波长下,蝶呤-6-羧酸在0.19~4.8 μg/mL范围内与色谱峰面积呈良好线性关系,相关系数为0.9999,方法检出限为0.015 μg/mL.尿液经0.45 μm滤膜过滤后,可直接进样分析,方法简便,应用于癌症病人和健康人尿样中蝶呤-6-羧酸测定,结果较好.方法的加标回收率为94.6%~100.2%,相对标准偏差为0.81%~ 5.07% . 相似文献
19.
免疫亲和色谱-HPLC-FLD法测定动物肝脏中10种喹诺酮类药物残留 总被引:2,自引:0,他引:2
利用免疫亲和色谱净化技术建立了可同时检测动物肝脏组织中10种喹诺酮类药物(麻保沙星、环丙沙星、诺氟沙星、单诺沙星、洛美沙星、恩诺沙星、沙拉沙星、二氟沙星、恶喹酸和氟甲喹)的高效液相色谱检测方法.对利用喹诺酮抗体制备的免疫亲和色谱柱的性能、操作条件进行了考察和优化.抗体的偶联量为5 g/L,其对10种喹诺酮药物的柱容量为3.75~6.67 μmol/L gel(1425~2135 mg/L gel),选用V(甲醇):V(PBS)=7:3作为洗脱溶液,连续使用12次后,QNs的柱容量仍能达到初始柱容量的38%~45%;IAC柱重复使用20次后,药物的回收率与样品的净化效果无明显变化.动物肝脏组织样品用PBS溶液提取,IAC柱净化,HPLC-FLD检测.方法的线性范围为0.15~200 μg/L,相关系数大于0.9989,检出限为0.05~0.15 μg/kg;10种喹诺酮类药物在动物肝脏的平均回收率为74.7%~94.8%,相对标准偏差为3.9%~12 1%. 相似文献
20.
建立了高效液相色谱法测定叶酸片中叶酸含量的方法。采用Symmetry C18色谱柱(150×4.6mm,3.5μm),以磷酸盐缓冲溶液(PBS,pH=6.3)为流动相,检测波长254nm,柱温35℃。叶酸在0.04~0.36μg/mL范围线性良好(r=0.9999),平均加标回收率为99.4%(RSD=0.44%)。该方法简便准确,精密度良好,适用于叶酸片中叶酸含量的测定。 相似文献