首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
Summary A reversed-phase, High-performance Liquid chromatographic method for the simultaneous determination of phenazopyridine and nitrofurantoin in tablets is described. An aminopropyl-silica (APS-Hypensil) 5μm column and a mobile phase consisting of Methanol:H2O: 0.05M sodium dihydrogen phosphate (50∶45∶5) were used. Calibration curves were linear over the concentration range 2–20μg/ml, with minimum detectability of 10ng/ml for both drugs. The method was applied to tablets containing the two species and the results obtained were compared to those given with a published method.  相似文献   

2.
A mixture of piracetam and vincamine was determined by 3 different methods. The first was the determination of piracetam and vincamine using the ratio-spectra first-derivative (DD1) spectrophotometric technique at 209 and 293 nm in concentration ranges of 10-45 and 2-14 microg/mL with mean recoveries of 99.22 +/- 0.72 and 99.67 +/- 0.79%, respectively. The second method was based on the resolution of the 2 components by bivariate calibration depending on a mathematic algorithm that provides simplicity and rapidity. The method depended on quantitative evaluation of the absorbencies at 210 and 225 nm in concentration ranges of 5-45 and 2-14 microg/mL, with mean recoveries of 100.33 +/- 0.54 and 100.44 +/- 0.98% for piracetam and vincamine, respectively. The third method was reversed-phase liquid chromatography using 0.05 M potassium dihydrogen phosphate-methanol (50 + 50, v/v) as the mobile phase, with the pH adjusted to 3.5 with phosphoric acid. The eluent was monitored at 215 nm in concentration ranges of 5-100 and 2-200 microg/mL, with mean recoveries of 99.62 +/- 0.67 and 99.32 +/- 0.85% for piracetam and vincamine, respectively. The suggested procedures were checked using laboratory-prepared mixtures and were successfully applied for the analysis of their pharmaceutical preparation. The methods retained their accuracy and precision when applying the standard addition technique. The results obtained by applying the proposed methods were statistically analyzed and compared with those obtained by the manufacturer's method.  相似文献   

3.
A simple, rapid, and precise reversed-phase liquid chromatographic method has been developed for the simultaneous determination of metformin in combination with glimepride. Under the developed conditions, good separation of the analytes was achieved in short analysis time. Several parameters affecting the separation of the analytes were studied, including pH and the concentration of SDS. The method is validated and shown to be linear in the range of 25 microg/mL to 150 microg/mL for metformin and 0.1 microg/mL to 0.6 microg/mL for glimepride. The method is applied for the analysis of these analytes in commercially available tablets.  相似文献   

4.
5.
6.
A method for the determination of 2-[(N-phenyl)benzylaminomethyl]-2-imidazoline X H3PO4 (antazoline phosphate) and 2-(1,2,3,4-tetrahydro-1-naphthyl)-2-imidazoline X HCl (tetrahydrozoline hydrochloride) in ophthalmic solution is described. The pharmaceutical preparation is analysed directly by reversed-phase ion-pair high-performance liquid chromatography and the method is very rapid, selective and simple.  相似文献   

7.
A sensitive high-performance liquid chromatographic assay was developed for the determination of tocainide enantiomers in plasma. Following extraction of tocainide from plasma, the enantiomers were derivatized with S-(+)-1-(1-naphthyl)ethylisocyanate. The resulting diastereomers were separated and quantified using normal-phase chromatography with fluorescence detection set at 220/345 nm (excitation/emission). The peaks, resolved with a resolution factor greater than 1.5, were free from interference. Linearity was established over the concentration range 0.25-10.0 mg/l for each enantiomer in plasma (r2 greater than 0.998). The inter-assay variability was less than 10% at all concentrations examined. The method can be used to determine the pharmacokinetics of tocainide enantiomers in man.  相似文献   

8.
Lanin SN  Nikitin YS 《Talanta》1989,36(5):573-579
Normal-phase high-performance liquid chromatography has been used for separation of phenol and its monoderivatives. Multi-component mixtures of hexane (non-polar component) with butan-1-ol, chloroform, butyl bromide, butyl chloride or diethyl ether (polar additives) were used as selective eluents. Silica gel "Silasorb 600" with specific surface area of about 600 m(2)/g and average particle size of $ 10 mum was used as the sorbent. Phenol and the o-, m-, p-isomers of cresol were concentrated by extraction with n-butyl acetate from aqueous solutions. A method for determination of microamounts of phenols in aqueous solutions in the presence of 160-fold amounts of aromatic hydrocarbons has been developed.  相似文献   

9.
10.
Summary Due to manifold physiological and cardioprotective actions of adenosine, the demand for a simple but accurate method to determine its concentration in plasma is increasing. The aim of this study was firstly to develop a simple isocratic method instead of the gradient elution or peak-shifting techniques used earlier and secondly to check conflicting data on the composition of stop-solution, added to the sample in order to prevent changes in adenosine concentration. Isocratic elution improved signal to noise ratio and concentrations of 100 mol L–1 dipyridamole and 2.5 mol L–1 erythro-9(2-hydroxy-3-nonyl)adenine in the blood sample effectively prevented both adenosine formation and degradation, even without the use of a 5-ecto-nucleotidase inhibitor. Lowering the concentration of dipyridamole to 25 mol L–1 caused more than a tenfold increase of adenosine concentration in two out of five cases and even 100 mol L–1 dipyridamole alone is not sufficient to inhibit adenosine deaminase in blood samples.  相似文献   

11.
A high-performance liquid chromatographic method for the determination of pirenzepine in human plasma is reported using imipramine as an internal standard. The assay has a lower limit of detection of 2.5 ng/ml. The calibration function is found to be linear in the range from 5 ng/ml up to at least 100 ng/ml. Two sets of chromatographic conditions are described, which provide different chromatographic selectivities for the separation of the compounds of interest from other material present in a sample.  相似文献   

12.
Two simple and accurate methods of analysis to determine pioglitazone hydrochloride (PIO) and mefformin hydrochloride (MET) in combined dosage forms were developed using second-derivative spectrophotometry and reversed-phase liquid chromatography (LC). PIO and MET in combined preparations (tablets) were quantified using the second-derivative responses at 227.55 nm for PIO and 257.25 nm for MET in spectra of their solutions in a mixture of methanol and acetonitrile (30 + 70). The calibration curves were linear [correlation coefficient (r) = 0.9984 for PIO and 0.9986 for MET] in the concentration range of 8-40 microg/mL for PIO and 4-12 microg/mL for MET. In the LC method, analysis was performed on a Hypersil ODS-C18 column with 5 microm particle size using the mobile phase acetonitrile-water-acetic acid (75 + 25 + 0.3), adjusted to pH 5.5 with liquor ammonia, at a flow rate of 0.5 mL/min. Measurement was made at a wavelength of 230 nm. Both the drugs were well resolved on the stationary phase, and the retention times were 8.5 min for PIO and 16.0 min for MET. The calibration curves were linear (r = 0.9933 for PIO and 0.9958 for MET) in the concentration range of 4-20 microg/mL for PIO and MET. Both methods were validated, and the results were compared statistically. They were found to be accurate, precise, and specific. The methods were successfully applied to the estimation of PIO and MET in combined tablet formulations.  相似文献   

13.
Two rapid, accurate and sensitive methods are developed and validated for the quantitative simultaneous determination of cefotaxime (CFX) and its active metabolite desacetylcefotaxime (DCFX) in urine.Based on the previous results which showed the four electron reduction of CFX at ≈ −0.5 V, and the new findings that DCFX reduction occurred at more positive potential (−0.23 V), the new adsorptive stripping differential pulse voltammetric (AdSDPV) method was developed for determination of CFX in the presence of DCFX. Linear responses were observed over a wide concentration range (0.07-0.52 μg/ml for CFX and 0.22-1.3 μg/ml for DCFX) in urine.The second assay involves subsequent separation on a reversed-phase HPLC column, with ultraviolet detection at 262 nm. Retention times were 4.057 and 1.960 min for CFX and DCFX, respectively. Linear responses were observed over a wide range, 0.55-6.60 μg/ml for CFX and 1.10-11.00 μg/ml for DCFX, in urine.The statistical evaluation for both methods was examined by means of within-day repeatability (n = 5) and day-to-day precision (n = 3) and was found to be satisfactory with high accuracy and precision.  相似文献   

14.
Mitoxantrone is one of the newer anthracenedione derivatives which has already been studied in phase I and II trials, where it has shown significant antitumor activity against a variety of human tumours. To determine the prolonged terminal half-life of mitoxantrone, we developed a sensitive high-performance liquid chromatographic method, providing a detection limit of 1 ng/ml of extracted serum. This system uses a C18 reversed-phase column. The mobile phase consists of a mixture of acetonitrile (30%, v/v) and an ammonium formate buffer (70%, v/v) with a pH of 2.7. Hexane sulphonic acid is added as an ion-pair former. Detection at a wavelength of 658 nm provides a highly selective system, showing no interfering peaks. Ametantrone, another anthracenedione derivative, is used as an internal standard. The extraction procedure for serum also uses hexane sulphonic acid in an ion-paired system. Because of the highly selective detection wavelength, urine samples can be injected without a sample clean-up procedure. This very sensitive method, combined with high selectivity and a fast and inexpensive serum clean-up procedure, has allowed us to document the prolonged terminal plasma half-life of mitoxantrone (levels of 2-5 ng/ml of plasma can still be detected six days after an intravenous infusion of 15 mg/m2 over 30 min). In urine an as yet unidentified metabolite was discovered.  相似文献   

15.
16.
Furusawa N 《Talanta》1999,49(2):461-465
A precise method is presented for determination of residual spiramycin (SP) in chicken eggs and tissues by high-performance liquid chromatography (HPLC). The sample preparation was performed by homogenizing with a mixture of acetonitrile and n-hexane (5:4, v/v) to minimize the fat amount followed by ultra-filtration using a MolCutII(R). The extracts containing SP were free from interfering compounds when examined by the normal-phase HPLC using a LiChrosorb(R) NH(2) column and a mobile phase of acetonitrile-water (85:15, v/v) with a photo-diode array detector. The average recoveries from spiked SP (0.1, 0.5 and 1.0 ppm) were in excess of 89.0% with coefficients of variation between 1.4 and 2.4%. The limit of detection was 0.1 ppm.  相似文献   

17.
18.
D-Lactate in biological samples was converted into a strongly fluorescent substance in a one-vial reaction. It was first converted into the pyruvate hydrazone in the presence of D-lactate dehydrogenase, an NADH-reoxidation system using diaphorase, D,L-6,8-thioctamide and hydrazine. This hydrazone was then converted into 2-hydroxy-6,7-dimethoxy-3-methylquinoxaline by 1,2-diamino-4,5-dimethoxybenzene in 1 M hydrochloric acid, and the quinoxaline was extracted and measured fluorimetrically at 432 nm (excitation at 365 nm). The calibration curve for D-lactate was linear up to at least 100 nmol/ml of the assay mixture, with a determination limit of 2 nmol/ml. The quinoxaline was also analysed by high-performance liquid chromatography with fluorimetric detection. The calibration curve for D-lactate was linear from 500 fmol to 75 nmol in the reaction mixture. This method was 4000 times more sensitive than the fluorimetric method, and could determine D-lactate in blood plasma volumes of less than 1 microliter.  相似文献   

19.
20.
A rapid and sensitive method for the quantitative determination of folylpolyglutamate hydrolase activity in crude tissue extracts was developed. The procedure is based on high-performance liquid chromatographic separation of folate analogue mono- and polyglutamates on a reversed-phase column using sodium dodecyl sulfate in water as the mobile phase. Interfering substances in tissue extracts were removed by gel filtration on centrifugally-eluted mini-columns of Sephadex G-25 prior to incubation of polyglutamate substrate with tissue extract hydrolase. Reactions were terminated by denaturation of the enzyme in sodium dodecyl sulfate, which subsequently served as the micellar solvent system for chromatographic separation of substrate from reaction products.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号