首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
The hydrolytic degradation of poly(bisphenol A)carbonate (PC) has been characterized by various liquid chromatography techniques. Size exclusion chromatography (SEC) showed a significant decrease in molecular mass as a result of hydrolytic degradation, while ‘liquid chromatography at critical conditions’ (LC-CC) was very successful for observing differences in functionality due to degradation, i.e. the formation of OH end-groups. To characterize and identify the observed differences semi on-line coupling of liquid chromatography to matrix-assisted laser desorption ionization time-of-flight mass spectrometry (MALDI-TOF-MS) and Fourier transform infrared spectroscopy (FT-IR) has proved to be very useful.Comprehensive two-dimensional liquid chromatography (2D-LC) was also applied to study the hydrolytic degradation of poly(bisphenol A)carbonate. LC-CC × SEC showed that the formation of poly(bisphenol A)carbonate with OH end-groups occurred over the whole molecular mass range. This information could not be obtained with the separate liquid chromatographic techniques, thereby illustrating the usefulness of 2D-LC.The main degradation processes of poly(bisphenol A)carbonate under the applied hydrolysis conditions turned out to be disappearance of cyclic PC oligomers, chain scission of PC and (subsequent) formation of OH end-groups. FT-IR, SEC and LC-CC have been used to follow the hydrolytic degradation with time. LC-CC proved to be the most promising technique to detect the degradation of poly(bisphenol A)carbonate at an early stage.  相似文献   

2.
This paper reports the effect of transfer line (TL) internal diameter (i.d.) on gas chromatographic separation characteristics such as efficiency and speed, when a multicapillary (MC) column is used for speciation analysis of mercury. Five different TL consisting of fused-silica capillaries with 0.15, 0.20, 0.25, 0.32, and 0.53 mm i.d. are compared. The separation efficiency and total chromatographic run time are critically affected by the i.d. of the TL. Narrow capillaries (i.d.0.20 mm) produce minimum peak dispersion whereas wide capillaries result in narrow peaks and shorter chromatographic analysis times. A thermodynamic approach is proposed to describe the motion of the analytes through the separation column and TL. The model provides good agreement with the experimental data for high pressures (35 psig) and wide TL (0.25 mm i.d.).Dedicated to the memory of Wilhelm Fresenius  相似文献   

3.
Several methods for evaluating separation quality in two-dimensional thin layer chromatography are discussed. These include using either the distance between spot centers for the pair of solutes that is the most difficult to separate in a mixture, or the value of a suitable, separation function, as criteria of overall separation quality. Contour diagrams may be constructed in which solvent compositions for each of the two-dimensional developments are the independent variables and spot separation or the value of a suitable function is the dependent variable. Such diagrams indicate which are the best and the worst regions of the two-dimensional solvent domain. These diagrams should be of value for comparing different solvent systems for two-dimensional thin layer chromatography.  相似文献   

4.
With the analysis of Chinese liquor Moutai as an example, the effect of different column combinations was studied on two-dimensional separation in comprehensive two-dimensional gas chromatography (GC × GC). A method to optimize column combinations was developed for achieving maximum orthogonality. Using a geometric approach to factor analysis, the degree of separation orthogonality was quantitatively estimated. The parameters evaluated include peak spreading angle, retention correlation, and practical peak capacity. When using the “reversed-type” column combinations (a polar column as the first dimension and a non- or less polar one as the second dimension), correlation coefficient was lower than or equal to 0.221, the spreading angle was higher than or equal to 77°, and more than 92% of the theoretical peak capacity was reasonably used. For Moutai liquor mainly consisting of some polar compounds, the HP-Innowax + DB1701 column combination was optimal. In addition, through the test of Grob mixture and McReynolds constant, the mechanism of solute-stationary phase interactions was disclosed in details, which validated the estimation of GC × GC orthogonality in a molecular level.  相似文献   

5.
6.
This paper reports the conditions of online hyphenation of supercritical fluid chromatography (SFC) with twin comprehensive two-dimensional gas chromatography (twin-GC × GC) for detailed characterization of middle distillates; this is essential for a better understanding of reactions involved in refining processes. In this configuration, saturated and unsaturated compounds that have been fractionated by SFC are transferred on two different GC × GC columns sets (twin-GC × GC) placed in the same GC oven. Cryogenic focusing is used for transfer of fractions into the first dimension columns before simultaneous GC × GC analysis of both saturated and unsaturated fractions. The benefits of SFC–twin-GC × GC are demonstrated for the extended alkane, iso-alkane, alkene, naphthenes and aromatics analysis (so-called PIONA analysis) of diesel samples which can be achieved in one single injection. For that purpose, saturated and unsaturated compounds have been separated by SFC using a silver loaded silica column prior to GC × GC analysis. Alkenes and naphthenes are quantitatively recovered in the unsaturated and saturated fractions, respectively, allowing their identification in various diesel samples. Thus, resolution between each class of compounds is significantly improved compared to a single GC × GC run, and for the first time, an extended PIONA analysis of diesel samples is presented.  相似文献   

7.
Summary This contribution to the problems of carbohydrate (sugar) column liquid chromatography, evaluates several currently used systems (reversed phase octadecylated silica gel, amino modified silica gel, cation exchangers on polystyrene and on silica gel basis, polyol derivatised silica gel and anion exchange systems). The elution pattern, analysis time, column efficiency and column life time expectancy are considered to be the important points for this comparison. The application of silica gel-based cation exchanger and of polyol derivatised silica gel is new to this field. The comparison and/or evaluation tries to be critical and to come to a conclusion for the choice of a recommended system.  相似文献   

8.
Capture columns are important interface tools for on line two-dimensional liquid chromatography (2D-LC). In this study, a systematic method was developed to evaluate and optimize the capture ability of capture columns by off-line method. First, the parameter ΔtRtR = t2t1t0W) was introduced to quantitatively represent the capture ability of the capture column by connecting a capture column behind the first dimensional column. Based on the value of ΔtR, an appropriate capture column was selected after the first dimensional column was fixed. Then, the capture ability of the selected column was promoted by adjusting the mobile phase of the first dimensional column. Capture ability was also optimized using complex sample analysis software system (CSASS) software. Second, the elution mode of the trapped compounds on the capture column was investigated by connecting the capture column before the second dimensional column. More specifically, in mode I, capture column was connected to the second dimension without changing the flow rate direction and the trapped compounds must pass through the capture column and be eluted into the second dimensional column. The contrary connection mode was mode II. It was found that mode I is more suitable method for 2D-LC. Finally, an off-line reversed-phase/hydrophilic interaction liquid chromatography two-dimensional liquid chromatography (RP/HILIC 2D-LC) system with a C18 capture column was developed to demonstrate the practical application of this method.  相似文献   

9.
Tao Wen  Guoan Luo  Jian Wang  Bo Yao  Jun Zhu 《Talanta》2007,71(2):854-860
Microemulsion electrokinetic chromatography (MEEKC) and solvent modified micellar electrokinetic chromatography (MEKC) were investigated with the goal of the rapid separation of complex heroin and amphetamine samples. The rapid simultaneous separation of 17 species of heroin, amphetamine and their basic impurities and adulterants was performed within about 10 min using MEEKC for the first time, whereas solvent modified MEKCs were unable to resolve all the components. The comparisons between MEEKC and solvent modified MEKC proved internal lipophilic organic phase in microemulsions played an important role in improving the separation performance with respect to efficiency. However, the role of internal lipophilic organic phase in MEEKC was disgusted at high concentrations of cosurfactant, and the separations of MEEKC and 1-butanol modified MEKC became similar at high concentrations of 1-butanol. The evaluation of reproducibility, linearity and detection limit of optimized MEEKC method provided good results for all the analytes investigated, thus allowing its application to real controlled drug preparation analysis.  相似文献   

10.
A new method to influence the separation selectivity of inorganic cations in capillary electrophoresis is presented. This method combines the use of certain crown ethers to form complexes with a specific cation (changing its ionic radius/charge ratio and thereby its electrophoretic mobility) with partitioning of the crown ether/analyte complex between an aqueous phase and a pseudo-stationary phase, such as the oil droplet of a microemulsion. Several microemulsions, including uncharged oil droplets and oil droplets with different degrees of surface charge were tested to evaluate their ability to improve the separation of the selected analytes.  相似文献   

11.
Three macrolide antibiotic components – ascomycin, tacrolimus and dihydrotacrolimus – were separated and purified by silver ion high-speed counter-current chromatography (HSCCC). The solvent system consisted of n-hexane–tert-butyl methyl ether–methanol–water (1:3:6:5, v/v) and silver nitrate (0.10 mol/l). The silver ion acted as a π-complexing agent with tacrolimus because of its extra side double bond compared with ascomycin and dihydrotacrolimus. This complexation modified the partition coefficient values and the separation factors of the three components. As a result, ascomycin, tacrolimus and dihydrotacrolimus were purified from 150 mg extracted crude sample with purities of 97.6%, 98.7% and 96.5%, respectively, and yields over 80% (including their tautomers). These results cannot be achieved with the same solvent system but without the addition of silver ion.  相似文献   

12.
In this paper, we report the use of micellar electrokinetic chromatography (MEKC) for the highly efficient preconcentration and separation of gold nanoparticles (Au NPs). We used the reversed electrode polarity stacking mode (REPSM) of the MEKC system for the on-line enhancement and separation of the Au NPs. Several parameters had dramatic effects on the systems’ performance, including the concentration of sodium dodecylsulfate (SDS) surfactant, the presence of salts in the NP solution, the pH of the running electrolyte, and the temperature of the capillary. Under the optimized conditions [buffer: SDS (70 mM) and 3-cyclohexylamino-1-propanesulfonic acid (CAPS; 10 mM) at pH 10.0; applied voltage: 20 kV; operating temperature: 25 °C; additive: sodium dihydrogenphosphate (NaH2PO4, 10 mM); REPSM strategy for sample preconcentration], the number of theoretical plates for the 5.3- and 40.1-nm-diameter Au NPs were 3000 and (an ultrahigh) 2.1 × 106, respectively; in addition, the detection sensitivities toward the Au NPs were enhanced ca. 20- and 380-fold, respectively, relative to those obtained using standard MEKC analysis conditions. Furthermore, monitoring the electropherograms using diode-array detection allowed us to identify and characterize the sizes of the separated NPs from their UV–vis spectra. Our findings suggest that MEKC is a highly efficient tool for both the preconcentration and separation of NPs.  相似文献   

13.
In the past few years, low-pressure gas chromatography (LP-GC) has been applied for the fast analysis of various pollutants in different environmental and food matrices. A typical LP-GC set-up involves the use of a short microbore column (typically 0.5–1 m × 0.10 mm internal diameter) at the injector side connected with a zero dead-volume connector to a short megabore column (typically 10 m × 0.53 mm) to be used with higher gas velocities. This set-up maintains atmospheric injection conditions, while the analytical column is operated under low-pressure conditions that are compatible with mass-spectrometer analyzers. Although the use of LP-GC results in a loss of separation efficiency, it offers a 3–5-fold reduction in analysis time for organic compounds and thus increased sample throughput and enhancement of the signal-to-noise ratio leading to improved detection limits. Considering the significance of, and the potential interest in, this topic, this review briefly describes the concept of LP-GC. Furthermore, we explore recent developments and applications of LP-GC, with a focus on the use of various column systems and analyzers. Finally, we critically evaluate the prospects for, and the limitations of, LP-GC.  相似文献   

14.
Modeling the retention in comprehensive two-dimensional gas chromatography (GC x GC) was achieved using retention indices obtained in conventional GC. Predicted results were compared with experimental data obtained in the two-dimensional separation of a synthetic hydrocarbon mixture. This proved to be helpful in optimizing the operating conditions of GC x GC separation of a complex petroleum sample and in identifying chemical families.  相似文献   

15.
In this study, we evaluate advantages and disadvantages of three hyphenated techniques for mercury speciation analysis in different sample matrices using gas chromatography (GC) with mass spectrometry (GC-MS), inductively coupled plasma mass spectrometry (GC-ICP-MS) and pyrolysis atomic fluorescence (GC-pyro-AFS) detection. Aqueous ethylation with NaBEt(4) was required in all cases. All systems were validated with respect to precision, with repeatability and reproducibility <5% RSD, confirmed by the Snedecor F-test. All methods proved to be robust according to a Plackett-Burnham design for 7 factors and 15 experiments, and calculations were carried out using the procedures described by Youden and Steiner. In order to evaluate accuracy, certified reference materials (DORM-2 and DOLT-3) were analyzed after closed-vessel microwave extraction with tetramethylammonium hydroxide (TMAH). No statistically significant differences were found to the certified values (p=0.05). The suitability for water samples analysis with different organic matter and chloride contents was evaluated by recovery experiments in synthetic spiked waters. Absolute detection and quantification limits were in the range of 2-6 pg for GC-pyro-AFS, 1-4 pg for GC-MS, with 0.05-0.21 pg for GC-ICP-MS showing the best limits of detection for the three systems employed. However, all systems are sufficiently sensitive for mercury speciation in environmental samples, with GC-MS and GC-ICP-MS offering isotope analysis capabilities for the use of species-specific isotope dilution analysis, and GC-pyro-AFS being the most cost effective alternative.  相似文献   

16.
Summary Although widely used to compare the performances of capillary columns the separation number is a poor index of the quality of a column. It is shown that it is a rubber ruler whose length is a function of temperature: the separation number of a column is a function not only of the effective plate number, which itself varies largely with the retention as measured by the capacity factor k, but also of the relative retention of then-alkanes used for the measurement. This relative retention is strongly dependent upon the temperature for a given stationary phase. Unless the temperature at which the separation number is measured be normalized as well as the k range in which the second alkane of the pair used is eluted, the separation numbers are meaningless for the appreciation of the performance of a column or comparison of different columns. Using alkanes eluted in the same k range to measure the separation number of a column we obtained a value almost twice as large at 80°C as at 180°C. In spite of their imperfections the plate number and the coating efficiency are easier to use and less misleading.  相似文献   

17.
Multivariate curve resolution-particle swarm optimization (MCR-PSO) algorithm is proposed to exploit pure chromatographic and spectroscopic information from multi-component hyphenated chromatographic signals. This new MCR method is based on rotation of mathematically unique PCA solutions into the chemically meaningful MCR solutions. To obtain a proper rotation matrix, an objective function based on non-fulfillment of constraints is defined and is optimized using particle swarm optimization (PSO) algorithm. Initial values of rotation matrix are calculated using local rank analysis and heuristic evolving latent projection (HELP) method. The ability of MCR-PSO in resolving the chromatographic data is evaluated using simulated gas chromatography–mass spectrometry (GC–MS) and high-performance liquid chromatography–diode array detection (HPLC–DAD) data. To present a comprehensive study, different number of components and various levels of noise under proper constraints of non-negativity, unimodality and spectral normalization are considered. Calculation of the extent of rotational ambiguity in MCR solutions for different chromatographic systems using MCR-BANDS method showed that MCR-PSO solutions are always in the range of feasible solutions like true solutions. In addition, the performance of MCR-PSO is compared with other popular MCR methods of multivariate curve resolution-objective function minimization (MCR-FMIN) and multivariate curve resolution-alternating least squares (MCR-ALS). The results showed that MCR-PSO solutions are rather similar or better (in some cases) than other MCR methods in terms of statistical parameters. Finally MCR-PSO is successfully applied in the resolution of real GC–MS data. It should be pointed out that in addition to multivariate resolution of hyphenated chromatographic signals, MCR-PSO algorithm can be straightforwardly applied to other types of separation, spectroscopic and electrochemical data.  相似文献   

18.
Having nearly exhausted the possibilities for generating peak capacity through improvements in column technology, chromatographers are increasingly looking to alternative ways of maximising chromatographic separation. In recent years there has been increasing activity in the field of comprehensive multidimensional separations to meet analysis demands. Comprehensive two-dimensional liquid chromatography (LC×LC) approaches offer high peak capacity which leads to significantly improved analytical performance over single-column liquid chromatography. There are several closely related avenues available for achieving an LC×LC separation and this review pays special attention to the different valve-based interfaces that have been used to comprehensively couple the first and second dimension columns in LC×LC systems. A brief discussion of column choices for selected applications and the conditions employed is also presented.  相似文献   

19.
Although there are many simple thin-layer chromatography (TLC) separations, many more are complex and involve more than a few components, that means having to use special high-performance TLC (HPTLC) plates or microspotting or banding devices to increase its resolving power if developing in only one direction. However, adding a second development to perform two-dimensional TLC (2D TLC) allows even better resolution of complex samples. This is because different modes of chromatography are being invoked by the use of one stationary phase with two mobile phases, bilayer plates, graft TLC, or multidimensional TLC. This paper is a review of recent applications that have benefitted from using 2D TLC in its various forms. They were chosen for their variety of sample types as well as the unique choices of plates and/or mobile phases made by the researchers to yield improved separations.  相似文献   

20.
The application of high temperature comprehensive two-dimensional (2D) liquid chromatography for quantitative characterization of chemical composition and molecular weight (MW) heterogeneities in polyolefins is demonstrated in this study by separating a physical blend of isotactic-polypropylene, ethylene-random-propylene copolymer, and high density polyethylene. The first dimension separation is based on adsorption liquid chromatography that fractionates the blend from low to high ethylene content. The second dimension is size-exclusion chromatography connected with light scattering (LS) and infrared (IR) detectors. The IR detector shows desired sensitivity and linearity for monitoring analyte concentrations in the eluent after 2D separations. In addition, the compositions of the analytes are also determined from the ratio of two IR absorbances at the specified wavelength regions, an absorbance for measuring the level of methyl groups in polyolefins and another absorbance for measuring concentration. The LS detector is used to determine absolute molecular weight of the analytes from the ratio of the light scattering signal to the IR concentration signal. The ability to obtain concentration, chemical composition, and MW of polyolefins after 2D separation provides new opportunities to discover structure-property relationships for polyolefins with complex structures/architectures.  相似文献   