首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 156 毫秒
1.
Fat‐soluble vitamins play a pivotal role in the progression of atherosclerosis and the development of cardiovascular disease. Therefore, plasma monitoring of their concentrations may be useful in the diagnosis of these disorders as well as in the process of treatment. The study aimed to develop and validate an HPLC–MS/MS method for determination of retinol, α‐tocopherol, 25‐hydroxyvitamin D2 and 25‐hydroxyvitamin D3 in plasma of patients with cardiovascular disease. The analytes were separated on an HPLC Kinetex F5 column via gradient elution with water and methanol, both containing 0.1% (v/v) formic acid. Detection of the analytes was performed on a triple‐quadrupole MS with multiple reaction monitoring via electrospray ionization. The analytes were isolated from plasma samples with liquid–liquid extraction using hexane. Linearity of the analyte calibration curves was confirmed in the ranges 0.02–2 μg/mL for retinol, 0.5–20 μg/mL for α‐tocopherol, 5–100 ng/mL for 25‐hydroxyvitamin D2 and 2–100 ng/mL for 25‐hydroxyvitamin D3. Intra‐ and inter‐assay precision and accuracy of the method were satisfactory. Short‐ and long‐term stabilities of the analytes were determined. The HPLC‐MS/MS method was applied for the determination of the above fat‐soluble vitamin concentrations in patient plasma as potential markers of the cardiovascular disease progression.  相似文献   

2.
Formononetin‐7‐O‐β‐d ‐glucoside has been proved to have significant anti‐inflammatory effect. To evaluate its rat pharmacokinetics, a rapid, sensitive, and specific liquid chromatography–tandem mass spectrometry method has been developed and validated for the quantification of formononetin‐7‐O‐β‐d ‐glucoside and its main metabolite formononetin in rat plasma. Samples were pretreated using a simple protein precipitation and the chromatographic separation was performed on a C18 column by a gradient elution using a mobile phase consisting of water and acetonitrile both containing 0.1% formic acid. Both analytes were detected using a tandem mass spectrometer in positive multiple reaction monitoring mode. The assay showed wide linear dynamic ranges of both 0.10–100 ng/mL, with acceptable intra‐ and inter‐batch accuracy and precision. The lower limits of quantification were both 0.10 ng/mL using 50 μL of rat plasma for two analytes. The method has been successfully used to investigate the oral pharmacokinetic profiles of both analytes in rats. After oral administration of formononetin‐7‐O‐β‐d ‐glucoside at the dose of 50 mg/kg, it was rapidly absorbed in vivo and metabolized to its metabolite formononetin. The plasma concentration‐time profiles both showed double‐peak phenomena, which would be attributed to the strong enterohepatic circulation of formononetin‐7‐O‐β‐d ‐glucoside.  相似文献   

3.
A rapid and simple LC with MS/MS method for the simultaneous determination of metoprolol and its two CYP2D6‐derived metabolites, α‐hydroxy‐ and O‐desmethylmetoprolol, in human plasma was established. Metoprolol (MET), its two metabolites, and the internal standard chlorpropamide were extracted from plasma (50 μL) using ethyl acetate. Chromatographic separation was performed on a Luna CN column with an isocratic mobile phase consisting of distilled water and methanol containing 0.1% formic acid (60:40, v/v) at a flow rate of 0.3 mL/min. The total run time was 3.0 min per sample. Mass spectrometric detection was conducted by ESI in positive ion selected‐reaction monitoring mode. The linear ranges of concentration for MET, α‐hydroxymetoprolol, and O‐desmethylmetoprolol were 2–1000, 2–500, and 2–500 ng/mL, respectively, with a lower limit of quantification of 2 ng/mL for all analytes. The coefficient of variation for the assay's precision was ≤ 13.2%, and the accuracy was 89.1–110%. All analytes were stable under various storage and handling conditions and no relevant cross‐talk and matrix effect were observed. Finally, this method was successfully applied to assess the influence of CYP2D6 genotypes on the pharmacokinetics of MET after oral administration of 100 mg to healthy Korean volunteers.  相似文献   

4.
A simple, robust, and rapid LC‐MS/MS method was developed for the quantitation of U0126 and validated in rat plasma. Plasma samples (20 μL) were deproteinized using 200 μL ACN containing 30 ng/mL of chlorpropamide, internal standard. Chromatographic separation performed on an Agilent Poroshell 120 EC‐C18 column (4.6 × 50 mm, 2.7 μm particle size) with an isocratic mobile phase consisting of a 70:30 v/v mixture of ACN and 0.1% aqueous formic acid. Each sample was run at 0.6 mL/min for a total run time of 2 min per sample. Detection and quantification were performed using a mass spectrometer in selected reaction‐monitoring mode with positive ESI at m/z 381 → 123.9 for U0126 and m/z 277 → 175 for the internal standard. The standard curve was linear over a concentration range of 20–5000 ng/mL with correlation coefficients greater than 0.9965. Precision, both intra‐ and interday, was less than 10.1% with an accuracy of 90.7–99.4%. No matrix effects were observed. U0126 in rat plasma degraded approximately 41.3% after 3‐h storage at room temperature. To prevent degradation, sample handling should be on an ice bath and all solutions kept at 4°C. This method was successfully applied to a pharmacokinetic study of U0126 at various doses in rats.  相似文献   

5.
A rapid, sensitive and selective liquid chromatography–tandem mass spectrometry method for the detection of tandospirone (TDS) and its active metabolite 1‐[2‐pyrimidyl]‐piperazine (1‐PP) in Sprague–Dawley rat plasma is described. It was employed in a pharmacokinetic study. These analytes and the internal standards were extracted from plasma using protein precipitation with acetonitrile, then separated on a CAPCELL PAK ADME C18 column using a mobile phase of acetonitrile and 5 mm ammonium formate acidified with formic acid (0.1%, v/v) at a total flow rate of 0.4 mL/min. The detection was performed with a tandem mass spectrometer equipped with an electrospray ionization source. The method was validated to quantify the concentration ranges of 1.000–500.0 ng/mL for TDS and 10.00–500.0 ng/mL for 1‐PP. Total time for each chromatograph was 3.0 min. The intra‐day precision was between 1.42 and 6.69% and the accuracy ranged from 95.74 to 110.18% for all analytes. Inter‐day precision and accuracy ranged from 2.47 to 6.02% and from 98.37 to 105.62%, respectively. The lower limits of quantification were 1.000 ng/mL for TDS and 10.00 ng/mL for 1‐PP. This method provided a fast, sensitive and selective analytical tool for quantification of tandospirone and its metabolite 1‐PP in plasma necessary for the pharmacokinetic investigation.  相似文献   

6.
A simple method that consumes low organic solvent is proposed for the analysis of phthalic acid esters in Chinese white spirit using dispersive liquid–liquid microextraction coupled with sweeping‐micellar electrokinetic chromatography. Tetrachloromethane and white‐spirit‐containing ethanol were used as the extraction and dispersing solvents, respectively. The electrophoresis separation buffer was composed of 5 mM β‐cyclodextrin, 50 mM sodium dodecyl sulfate and 25 mM borate buffer (pH 9.2) with 9% acetonitrile, enabling the baseline resolution of the analytes within 13 min. Under the optimum conditions, satisfactory linearities (5–1000 ng/mL, r ≥ 0.9909), good reproducibility (RSD ≤ 6.7% for peak area, and RSD ≤ 2.8% for migration time), low detection limits (0.4–0.8 ng/mL) and acceptable recovery rates (89.6–105.7%) were obtained. The proposed method was successfully applied to 22 Chinese white spirits, and the content of dibutyl phthalate in 55% of the samples exceeded the Specific Migration Limit of 0.3 mg/kg established by the domestic and international regulations.  相似文献   

7.
A high‐throughput, specific, and rapid liquid chromatography with tandem mass spectrometry method was established and validated for the simultaneous determination of atorvastatin and its two major metabolites, ortho‐hydroxyatorvastatin and para‐hydroxyatorvastatin, in human plasma. A simple salting‐out‐assisted liquid–liquid extraction using acetonitrile and a mass‐spectrometry‐friendly salt, ammonium acetate, was employed to extract the analytes from human plasma. A recovery of more than 81% for all analytes was achieved in 1 min extraction time. Chromatographic separation was performed on a Kinetex XB C18 column utilizing a gradient elution starting with a 60% of water solution (1% formic acid), followed by increasing percentages of acetonitrile. Analytes were detected on a tandem mass spectrometer equipped with an electrospray ionization source that was operated in the positive mode, using the transitions of m/z 559.3 → m/z 440.2 for atorvastatin, and m/z 575.3 → m/z 440.2 for both ortho‐ and para‐hydroxyatorvastatin. Deuterium‐labeled compounds were used as the internal standards. The method was validated over the concentration ranges of 0.0200–15.0 ng/mL for atorvastatin and ortho‐hydroxyatorvastatin, and 0.0100–2.00 ng/mL for para‐hydroxyatorvastatin with acceptable accuracy and precision. It was then successfully applied in a bioequivalence study of atorvastatin.  相似文献   

8.
A rapid and selective liquid chromatography/tandem mass spectrometric method was developed for the simultaneous determination of capecitabine and its metabolites 5′‐deoxy‐5‐fluorocytidine (5′‐DFCR), 5′‐deoxy‐5‐fluorouracil (5′‐DFUR), 5‐fluorouracil (5‐FU) and dihydro‐5‐fluorouracil (FUH2) in human plasma. A 200 μL human plasma aliquot was spiked with a mixture of internal standards fludarabine and 5‐chlorouracil. A single‐step protein precipitation method was employed using 10% (v/v) trichloroacetic acid in water to separate analytes from bio‐matrices. Volumes of 20 μL of the supernatant were directly injected onto the HPLC system. Separation was achieved on a 30 × 2.1 mm Hypercarb (porous graphitic carbon) column using a gradient by mixing 10 mm ammonium acetate and acetonitrile–2‐propanol–tetrahydrofuran (1 : 3 : 2.25, v/v/v). The detection was performed using a Finnigan TSQ Quantum Ultra equipped with the electrospray ion source operated in positive and negative mode. The assay quantifies a range from 10 to 1000 ng/mL for capecitabine, from 10 to 5000 ng/mL for 5′‐DFCR and 5′‐DFUR, and from 50 to 5000 ng/mL for 5‐FU and FUH2 using a plasma sample of 200 μL. Correlation coefficients (r2) of the calibration curves in human plasma were better than 0.99 for all compounds. At all concentration levels, deviations of measured concentrations from nominal concentration were between ?4.41 and 3.65% with CV values less than 12.0% for capecitabine, between ?7.00 and 6.59% with CV values less than 13.0 for 5′‐DFUR, between ?3.25 and 4.11% with CV values less than 9.34% for 5′‐DFCR, between ?5.54 and 5.91% with CV values less than 9.69% for 5‐FU and between ?4.26 and 6.86% with CV values less than 14.9% for FUH2. The described method was successfully applied for the evaluation of the pharmacokinetic profile of capecitabine and its metabolites in plasma of treated cancer patients. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

9.
In the present investigation, a series of 4‐((3‐(trifluoromethyl)‐5,6‐dihydro‐[1,2,4]triazolo[4,3‐a]pyrazin‐7(8H)‐yl)methyl)benzenamine analogs 6a–o were synthesized and characterized by IR, NMR (1H and 13C), and mass spectra. All newly synthesized compounds 6a–o were prepared under conventional and microwave irradiation methods. These compounds obtained in higher yields and in shorter reaction times in the microwave irradiation method when compared with the conventional method. Synthesized compounds 6a–o were inspected for their in vitro antitubercular activity against Mycobacterium tuberculosis H37Ra using an established XTT reduction menadione assay. Among the screened compounds, 6i (IC50: 1.82 μg/mL), 6j (IC50: 1.02 μg/mL), and 6k (IC50: 1.59 μg/mL) showed excellent activity. Furthermore, compound 6i showed MIC90 value of 16.02 μg/mL. In summary, the results indicate the identification of some novel, selective, and specific inhibitors against M. tuberculosis that can be explored further for the potential antitubercular drug.  相似文献   

10.
Pantoprazole, a proton pump inhibitor, is clinically used for the treatment of peptic diseases. An enantioselective LC‐MS/MS method was developed and validated for the simultaneous determination of pantoprazole enantiomers in human plasma. Pantoprazole enantiomers and the internal standard were extracted from plasma using acetonitrile. Chiral separation was carried on a Chiralpak IE column using the mobile phase consisted of 10 mm ammonium acetate solution containing 0.1% acetic acid–acetonitrile (28 : 72, v /v). MS analysis was performed on an API 4000 mass spectrometer. Multiple reactions monitoring transitions of m /z 384.1→200.1 and 390.1→206.0 were used to quantify pantoprazole enantiomers and internal standard, respectively. For each enantiomer, no apparent matrix effect was found, the calibration curve was linear over 5.00–10,000 ng/mL, the intra‐ and inter‐day precisions were below 10.0%, and the accuracy was within the range of –5.6% to 0.6%. This method was applied to the stereoselective pharmacokinetic studies in human after intravenous administration of S ‐(–)‐pantoprazole sodium injections. No chiral inversion was observed during sample storage, preparation procedure and analysis. While R ‐(+)‐pantoprazole was detected in human plasma with a slightly high concentration, which implied that S ‐(–)‐pantoprazole may convert to R ‐(+)‐pantoprazole in some subjects.  相似文献   

11.
A sensitive and reliable ultra‐high‐performance liquid chromatography–electrospray ionization–tandem mass spectrometry (UHPLC‐MS/MS) method was developed and validated for the simultaneous determination of four active components of Semen Cassiae extract (aurantio‐obtusin, chrysoobtusin, obtusin and 1‐desmethylobtusin) in rat plasma after oral administration. Chromatographic separation was achieved on an Agilent Poroshell 120 C18 column with gradient elution using a mobile phase that consisted of acetonitrile‐ammonium acetate in water (30 mm ) at a flow rate of 0.4 mL/min. Detection was performed by a triple‐quadrupole tandem mass spectrometer in multiple reaction monitoring mode. The calibration curve was linear over a range of 3.24–1296 ng/mL for aurantio‐obtusin, 0.77–618 ng/mL for chrysoobtusin, 34.55–1818 ng/mL for obtusin and 1.86–1485 ng/mL for 1‐desmethylobtusin. Inter‐ and intra‐day assay variation was <15%. All analytes were shown to be stable during all sample storage and analysis procedures. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

12.
A highly sensitive, specific and enantioselective assay has been validated for the quantitation of OTX015 enantiomers [(+)‐OTX015 and (−)‐OTX015] in mice plasma on LC–MS/MS‐electrospray ionization as per regulatory guidelines. Protein precipitation was used to extract (±)‐OTX015 enantiomers and internal standard (IS) from mice plasma. The active [(−)‐OTX015] and inactive [(+)‐OTX015] enantiomers were resolved on a Chiralpak‐IA column using an isocratic mobile phase (0.2% ammonia/acetonitrile 20 : 80, v /v) at a flow rate of 1.2 mL/min. The total run time was 6.0 min. (+)‐OTX015, (−)‐OTX015 and IS eluted at 3.34, 4.08 and 4.77 min, respectively. The MS/MS ion transitions monitored were m/z 492 → 383 for OTX015 and m/z 457 → 401 for IS. The standard curves for OTX015 enantiomers were linear (r 2 > 0.998) in the concentration range 1.03–1030 ng/mL. The inter‐ and intraday precisions were in the range 2.20–13.3 and 8.03–12.1% and 3.80–14.4 and 8.97–13.6% for (+)‐OTX015 and (−)‐OTX015, respectively. Both the enantiomers were found to be stable in a battery of stability studies. This novel method has been applied to the study of stereoselective oral pharmacokinetics of (−)‐OTX015 and unequivocally demonstrated that (−)‐OTX015 does not undergo chiral inversion to its antipode in vivo in mice.  相似文献   

13.
A sensitive and rapid LC–MS/MS method was developed and validated for the simultaneous quantitation of four HDAC inhibitors, namely belinostat (BST), panobinostat (PST), rocilinostat (RST) and vorinostat (VST), in mouse plasma as per regulatory guidelines. The analytes and internal standard were extracted from 50 μL mouse plasma by protein precipitation, followed by chromatographic separation using an Atlantis C18 column with an isocratic mobile phase comprising 0.1% formic acid–acetonitrile (25:75, v /v) at a flow rate of 0.5 mL/min within 2.5 min. Detection and quantitation were done by multiple reaction monitoring on a triple quadrupole mass spectrometer following the transitions: m/z 319 → 93, 350 → 158, 434 → 274 and 265 → 232 for BST, PST, RST and VST, respectively, in the positive ionization mode. The calibration curves were linear from 2.92 to 2921 ng/mL for BST and PST and from 1.01 to 1008 ng/mL for RST and VST with r 2 ≥ 0.99 for all of the analytes. The intra‐ and inter‐batch accuracy and precision (CV) across quality controls varied from 85.5 to 112% and from 2.30 to 12.5, respectively, for all of the analytes. Analytes were found to be stable under different stability conditions. The method was applied to an i.v. pharmacokinetic study in mice.  相似文献   

14.
A sensitive and reliable ultra‐high‐performance liquid chromatography with tandem mass spectrometry (UHPLC–MS/MS) method was developed and validated for simultaneous determination of l ‐tetrahydropalmatine (l ‐THP) and its active metabolites l ‐isocorypalmine (l ‐ICP) and L ‐corydalmine (l ‐CD) in rat plasma. The analytes were extracted by liquid–liquid extraction and separated on a Bonshell ASB C18 column (2.1 × 100 mm; 2.7 μm; Agela) using acetonitrile–formic acid aqueous as mobile phase at a flow rate of 0.2 mL/min in gradient mode. The method was validated over the concentration range of 4.00–2500 ng/mL for l ‐THP, 0.400–250 ng/mL for l ‐ICP and 1.00–625 ng/mL for l ‐CD. Intra‐ and inter‐day accuracy and precision were within the acceptable limits of <15% at all concentrations. Correlation coefficients (r ) for the calibration curves were >0.99 for all analytes. The quantitative method was successfully applied for simultaneous determination of l ‐THP and its active metabolites in a pharmacokinetic study after oral administration with l ‐THP at a dose of 15 mg/kg to rats.  相似文献   

15.
A simple, high‐throughput and highly sensitive liquid chromatography coupled with tandem mass spectrometry (LC–MS/MS) method has been developed for the simultaneous estimation of rosuvastatin and free ezetimibe. Liquid–liquid extraction was carried out using methyl‐tert butyl ether after prior acidification from 300 μL human plasma. The recovery for both the analytes and their deuterated internal standards (ISs) ranged from 95.7 to 99.8%. Rosuvastatin and ezetimibe were separated on Symmetry C18 column using acetonitrile and ammonium formate buffer, pH 3.5 (30:70, v/v) as the mobile phase. The analytes were well resolved with a resolution factor of 3.8. Detection and quantitation were performed under multiple reaction monitoring using ESI(+) for rosuvastatin (m/z 482.0 → 258.1) and ESI(−) for ezetimibe (m/z 407.9 → 271.1). A linear response function was established in the concentration ranges of 0.05–50.0 ng/mL and 0.01–10.0 ng/mL for rosuvastatin and ezetimibe, respectively, with correlation coefficient, r2 ≥ 0.9991. The IS‐normalized matrix factors for the analytes ranged from 0.963 to 1.023. The developed method was successfully used to compare the pharmacokinetics of a fixed‐dose combination tablet of rosuvastatin‐ezetimibe and co‐administered rosuvastatin and ezetimibe as separate tablets to 24 healthy subjects. The reliability of the assay was also assessed by reanalysis of 115 subject samples.  相似文献   

16.
A fast, sensitive, and high‐throughput ultra‐HPLC–MS/MS method has been developed and validated for the simultaneous determination of three main active constituents of Euphorbiae pekinensis Radix in rat plasma. After addition of the internal standard, plasma samples were extracted by liquid–liquid extraction with ethyl acetate/isopropanol (1:1, v/v) and separated on a CAPCELL PAK C18 column (100 × 2.0 mm, 2 μm, Shiseido, Japan), using a gradient mobile phase system of methanol/water. The detection of the analytes was performed on a 4000Q UHPLC–MS/MS system with turbo ion spray source in the negative ion and multiple reaction‐monitoring mode. The linear range was 1.0–1000 ng/mL for 3,3′‐di‐O‐methyl ellagic acid‐4′‐Oβ‐d ‐glucopyranoside (i), 1.5–1500 ng/mL for 3,3′‐di‐O‐methyl ellagic acid‐4′‐Oβ‐d ‐xylopyranoside (ii), and 5.0–5000 ng/mL for 3,3′‐di‐O‐methyl ellagic acid (iii). The intra‐ and interday precision and accuracy of all the analytes were within 15%. The extraction recoveries of the three analytes and internal standard from plasma were all more than 80%. The validated method was first successfully applied to the evaluation of pharmacokinetic parameters of compounds 1 , 2 , and 3 in rat plasma after intragastric administration of the Euphorbiae pekinensis Radix extract.  相似文献   

17.
A simple, sensitive and reproducible ultra‐performance liquid chromatography–tandem mass spectrometry method has been developed for the simultaneous determination of atenolol, a β‐adrenergic receptor‐blocker and chlorthalidone, a monosulfonamyl diuretic in human plasma, using atenolol‐d7 and chlorthalidone‐d4 as the internal standards (ISs). Following solid‐phase extraction on Phenomenex Strata‐X cartridges using 100 μL human plasma sample, the analytes and ISs were separated on an Acquity UPLC BEH C18 (50 mm × 2.1 mm, 1.7 µm) column using a mobile phase consisting of 0.1% formic acid–acetonitrile (25:75, v/v). A tandem mass spectrometer equipped with electrospray ionization was used as a detector in the positive ionization mode for both analytes. The linear concentration range was established as 0.50–500 ng/mL for atenolol and 0.25–150 ng/mL for chlorthalidone. Extraction recoveries were within 95–103% and ion suppression/enhancement, expressed as IS‐normalized matrix factors, ranged from 0.95 to 1.06 for both the analytes. Intra‐batch and inter‐batch precision (CV) and accuracy values were 2.37–5.91 and 96.1–103.2%, respectively. Stability of analytes in plasma was evaluated under different conditions, such as bench‐top, freeze–thaw, dry and wet extract and long‐term. The developed method was superior to the existing methods for the simultaneous determination of atenolol and chlorthalidone in human plasma with respect to the sensitivity, chromatographic analysis time and plasma volume for processing. Further, it was successfully applied to support a bioequivalence study of 50 mg atenolol + 12.5 mg chlorthalidone in 28 healthy Indian subjects. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

18.
;A simple and reproducible method was developed for the quantification of ketamine and S(+)‐ketamine in dog plasma using a high‐performance liquid chromatography system coupled to a positive ion electrospray mass spectrometric analysis. Solid‐phase extraction was used for extracting analytes from dog plasma samples. The analytes were separated on a Zorbax SB C18 column (100 × 2.1 mm, 3.5 μm) with acetonitrile–formate buffer (10 mM ammonium formate and 0.3% formic acid) (17 : 83, v/v) as mobile phase at a flow‐rate of 0.2 mL/min. Detection was operated under selected ion monitoring mode. [M + H]+ at m/z 238 for ketamine and S(+)‐ketamine and [M + H]+ at m/z 180 for phenacetin (internal standard) were selected as detecting ions, respectively. The method was linear in the concentration range 51.6–2580 ng/mL. The intra‐ and inter‐day precisions (RSD %) were within 11.3% and the assay accuracies ranged from 80.0 to 101.4%. Their average recoveries were greater than 91.1% at all test concentrations. The analytes were proved to be stable during all sample storage, preparation and analysis procedures. The method was successfully applied to the toxicokinetics study and comparison of ketamine and S (+)‐ketamine following intravenous administration to dogs. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

19.
5‐Substituted (amine, alkyl, aryl, heterocyclic) 4‐(1,3,4‐thiadiazol‐2‐yl)benzene‐1,3‐ diols were synthesized, and their antifungal properties were examined. The compounds were obtained by the one‐pot reaction of sulfinylbis((2,4‐dihydroxyphenyl)methanethione) with hydrazides or thiosemicarbazides. Their structures were identified from elemental, IR, 1H NMR, and MS spectra analyses. The activities of the derivatives against five phytopathogenic fungi in vitro were measured. Moderate fungicidal effect of the compounds under consideration was found. © 2010 Wiley Periodicals, Inc. Heteroatom Chem 21:533–540, 2010; View this article online at wileyonlinelibrary.com . DOI 10.1002/hc.20645  相似文献   

20.
The therapeutic drug monitoring of paroxetine could be used to optimize the pharmacological treatment of depressed patients. A simple and sensitive high‐performance liquid chromatography procedure was developed for the determination of paroxetine in serum. After simple pretreatment of serum (50 μL) with acetonitrile and o‐phthalaldehyde, paroxetine was derivatized with 4‐(5,6‐dimethoxy‐2‐phthalimidinyl)‐2‐methoxyphenylsulfonyl chloride at 70°C for 20 min in borate buffer (0.1 mol/L, pH 8.0) to produce a fluorescent product. The derivative was separated on a reversed‐phase column at 40°C for stepwise elution with (A) acetic acid (10 mmol/L) and (B) acetonitrile. The flow rate was 1.0 mL/min. The fluorescence intensity was monitored at excitation and emission wavelengths of 320 and 400 nm, respectively. The within‐day and day‐to‐day relative standard deviations were 3.0–3.4 and 2.7–8.3%, respectively. The detection limit of paroxetine was 8.3 fmol at a signal‐to‐noise ratio of 3. As the proposed method that only requires a small quantity of serum (50 μL) is simple, sensitive and reproducible, it would be useful for clinical and biochemical research as well as drug monitoring. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏