1.
The need for novel packing materials in both capillary electrochromatography (CEC) and capillary liquid chromatography (CLC) is apparent and the development towards more selective, application-oriented chromatographic phases is under progress world-wide. In this study we have synthesized new polyethyleneimine (PEI) functionalized Mn(2)O(3), SiO(2), SnO(2), and ZrO(2) particles for the fabrication of packed capillary columns for CEC and CLC. The nanocasting approach was successful for the preparation of functionalized metal oxide materials with a controlled porosity and morphology. PEI functionalization was done using ethyleneimine monomers to create particles which are positively charged in aqueous solution below pH 9. This functionalization allowed the possibility to have both hydrophobic (due to its alkyl chain) and ionic interactions (due to positively charged amino groups) with selected compounds. For comparison aminopropyl-functionalized silica was also synthesized and tested. Both slurry pressure and electrokinetic packing procedures used gave similar results, but fast sedimentation of the material caused some problems during the packing. The high stability and wide pH range of PEI-functionalized SiO(2) material, with potential for hydrophobic and electrostatic interactions, proved to be useful for the CEC and CLC separation of some model acidic and neutral compounds.  相似文献   

2.
3.
4.
Cortex Moutan (Radicis Cortex Moutan), the dried root bark of Paeonia moutan and P. spp., contains a series of water‐soluble tannins. With the eight components, 1 4,6‐di‐O‐GG (4,6‐di‐O‐galloyl‐D‐glucose), 2 1,2,3,6‐tetra‐O‐GG, 3 1,2,3,4,6‐penta‐O‐GG, 4 1,3,4,6‐tetra‐O‐GG, 5 3,4,6‐tri‐O‐GG, 6 1,3,6‐tri‐O‐GG, 7 3,6‐di‐O‐GG, and 8 1,2,6‐tri‐O‐GG, as marker substances, a rapid and efficient method of analysis based on HPLC and CE was developed. Using a phosphate eluent, a 5C18‐MS separating column, and a detection wavelength of 280 nm, HPLC was successfully used to analyze the eight constituents within 60 min. The analysis can be completed within 50 min, using the MEKC mode with a buffer composed of borate, SDS, and isopropanol, and a detection wavelength of 210 nm. The detection limit for the marker substances varied from 0.04 to 0.93 μg/mL for the HPLC method and 0.02 to 0.36 μg/mL for the CE method.  相似文献   

5.
A simple capillary flow porometer (CFP) was assembled for through-pore structure characterization of monolithic capillary liquid chromatography columns in their original chromatographic forms. Determination of differential pressures and flow rates through dry and wet short capillary segments provided necessary information to determine the mean diameters and size distributions of the through-pores. The mean through-pore diameters of three capillary columns packed with 3, 5, and 7 μm spherical silica particles were determined to be 0.5, 1.0 and 1.4 μm, with distributions ranging from 0.1 to 0.7, 0.3 to 1.1 and 0.4 to 2.6 μm, respectively. Similarly, the mean through-pore diameters and size distributions of silica monoliths fabricated via phase separation by polymerization of tetramethoxysilane (TMOS) in the presence of poly(ethylene glycol) (PEG) verified that a greater number of through-pores with small diameters were prepared in columns with higher PEG content in the prepolymer mixture. The CFP system was also used to study the effects of column inner diameter and length on through-pore properties of polymeric monolithic columns. Typical monoliths based on butyl methacrylate (BMA) and poly(ethylene glycol) diacrylate (PEGDA) in capillary columns with different inner diameters (i.e., 50–250 μm) and lengths (i.e., 1.5–3.0 cm) were characterized. The results indicate that varying the inner diameter and/or the length of the column had little effect on the through-pore properties. Therefore, the through-pores are highly interconnected and their determination by CFP is independent of capillary length.  相似文献   

6.
A simple approach to fabricate hybrid monolithic column within the confines of fused-silica capillaries (75 μm i.d.) was introduced. A polyhedral oligomeric silsesquioxanes (POSS) reagent containing a methacrylate group was selected as functional monomer, and copolymerized with bisphenol A dimethacrylate (BPADMA) or ethylene dimethacrylate (EDMA) in the presence of porogenic solvents via thermally initiated free radical polymerization. After optimization of the preparation conditions, two POSS-containing hybrid monoliths were successfully prepared and exhibited good permeability and stability. By comparison of the separation efficiencies of the resulting poly(POSS-co-BPADMA) and poly(POSS-co-EDMA) monoliths in capillary electrochromatography (CEC) and capillary liquid chromatography (cLC), it was indicated the former has better column efficiencies for alkylbenzenes, phenols, anilines and PAHs in CEC and cLC than the latter. Particularly, the hybrid poly(POSS-co-BPADMA) monolith is more suitable for separation of PAHs due to π–π interaction between the analytes and aromatic rings in the surface of monolithic stationary phase.  相似文献   

7.
A series of ionic liquids (ILs) monolithic capillary columns based on 1-vinyl-3-octylimidazolium (ViOcIm+) were prepared by two approaches (“one-pot” approach and “anion-exchange” approach). The effects of different anions (bromide, Br; tetrafluoroborate, BF4; hexafluorophosphate, PF6; and bis-trifluoromethanesulfonylimide, NTf2) on chromatography performance of all the resulting columns were investigated systematically under capillary electrochromatography (CEC) mode. The results indicated that all these columns could generate a stable reversed electroosmotic flow (EOF) over a wide pH range from 2.0 to 12.0. For the columns prepared by “one-pot” approach, the EOF decreased in the order of ViOcIm+Br > ViOcIm+BF4 > ViOcIm+PF6 > ViOcIm+NTf2 under the same CEC conditions; the ViOcIm+Br based column exhibited highest column efficiencies for the test small molecules; the ViOcIm+NTf2 based column possessed the strongest retention for aromatic hydrocarbons; and baseline separation of four standard proteins was achieved on ViOcIm+NTf2 based column corresponding to the highest column efficiency of 479 000 N m−1 for cytochrome c (Cyt c). These results indicated that the property of ILs based columns could be tuned successfully by changing anions, which gave these columns potential to separate both small molecules and macro biomolecules.  相似文献   

8.
A short length of a sol‐gel monolith was initially prepared as the temporary frit in a 100 μm inner diameter fused‐silica capillary by an in situ photopolymerization. The packed 4 μm octadecylsilane particles were then immobilized within the identical sol‐gel solution through the same photopolymerization process. The prepared fritless capillary column was examined for the chromatographic performance by the self‐developed capillary liquid chromatography system. Baseline separation of the model analytes was achieved including thiourea, benzene, toluene and ethylbenzene with the lowest theoretical plate height about 66 μm for the retained component. A scanning electron micrograph was used to characterize the temporary frit and entrapped microspheres. The inorganic polymer matrix in the microsphere‐packed column functioned to link microspheres at specific sphere‐sphere and sphere‐capillary contact points. Furthermore, the stability and porosity of the fritless column were systematically investigated by a simple flow method.  相似文献   

9.
10.
A novel monolithic capillary column (530 microm i.d.) was prepared for capillary liquid chromatography (CLC) by in situ copolymerization of octyl methacrylate (MAOE) and ethylene dimethacrylate (EDMA) in the presence of a porogen solvent containing 1-propanol, 1,4-butanediol, and water with azobisisobutyronitrile as the initiator. The influences of the contents of the porogen solvent, EDMA and the various concentration ratios of 1-propanol to 1,4-butanediol in the polymerization mixture on the morphology, porosity, globule size, stability and column efficiency were investigated. The morphology and pore size distribution of monolithic capillary columns were characterized by SEM and mercury intrusion porosimetry, respectively. Chromatographic evaluations of the columns were performed under CLC mode. The results showed that good permeability and stability can be obtained under optimal experimental conditions. The separation results of some acid, neutral and basic analytes demonstrated the hydrophobicity and low affinity to basic analytes of the new column. Three metal ions, i.e. Mg(II), Zn(II) and Cd(II) were also separated under ion-pair mode on the new monolithic capillary column and the results were acceptable.  相似文献   

11.
A novel amphiphilic silica‐based monolithic column having surface‐bound octanoyl‐aminopropyl moieties was successfully prepared by a one‐step in situ derivatization process. As expected, the amphiphilic monolithic column exhibited RP chromatographic behavior toward non‐polar solutes (e.g., alkyl benzenes) with high column performance. As the pH of the buffer inside the column increases, the EOF changed from −2.65×10−8m2 V−1s−1 at pH 3.0 to 1.20×10−8 m2 V−1s−1 at pH 8.0 with the reversion of EOF at about pH 6.4. Using acidic mobile phase, five aromatic acids can be efficiently separated in less than 6 min under co‐EOF conditions. For basic compounds, symmetrical peaks were obtained due to the existence of hydrophilic acyl amide group, which can effectively minimize the adsorption of the positively charged basic analyte to the silica‐based surface of the capillary column.  相似文献   

12.
A novel fritting technology was introduced for the fused-silica capillary. The technique involved sintering of stainless steel (SS) particles at the tip of capillary through flame heating. A simple butane gas based welding torch was used for sintering the SS particles. The new fritting technique, flame induced sintering of SS particles (FIS/SSP), was applied for making frits with different inlet diameters (75 μm, 100 μm, 250 μm and 530 μm). The changes in morphologies of SS particles during sintering process were identified by scanning electron microscopy (SEM). Frits with the length of 0.5-1 mm and capillaries with inner diameter about 50-100 μm were fabricated through suitable selection of experimental conditions (size of SS particles and heating mode). The frits prepared by FIS/SSP technique exhibited adequate separation properties and mechanical strength. Columns packed with C18 particles were stable with these frits in a few important chromatographic operations. Frits prepared by FIS/SSP technique was used in three typical separation modes namely, capillary electrochromatography (CEC), p-assisted CEC (p-CEC) and low pressure liquid chromatography (LPLC). Importantly, no bubble formation was noticed with the frit over a period of one week. A good peak symmetry and high efficiency for separation were obtained using pressure-assisted CEC, p-CEC and low pressure-driven separation modes.  相似文献   

13.
Boronate affinity chromatography is an important tool for specific isolation of cis-diol-containing compounds such as glycoproteins, RNA and carbohydrates. Boronate functionalized monolithic capillaries have been recently developed for specific capture of cis-diol-containing small biomolecules, but the apparent hydrophobicity of the columns prevents them from specific capture of glycoproteins. In this paper, a hydrophilic boronate affinity monolithic capillary was prepared by in situ free radical polymerization, using 4-vinylphenylboronic acid (VPBA) and N, N′-methylenebisacrylamide (MBAA) as functional monomer and cross-linker, respectively. The prepared poly(VPBA-co-MBAA) monolithic capillary exhibited uniform open channel network and high density of accessible boronic acid. Due to the utilization of hydrophilic cross-linker, the prepared column was hydrophilic, allowing for specific capture of glycoproteins.  相似文献   

14.
In the previous part of this study, a significant improvement of the fundamental relationships that control GC resolution in a pressure‐tunable assembly operating in isothermal conditions inside a single oven was made. A theoretical approach for the correct choice of the working temperature was proposed for the first time. In this second part of our report, a new interfacing device has been proposed for a rapid and reliable alignment of the two columns at the midpoint junction. Moreover, the results of a series of experimental tests have confirmed the validity of the proposed mathematical models.  相似文献   

15.
Creatinine in human serum was separated in a fused-silica capillary with H3PO4 (75 mmol/L, pH 2.5) as BGE, followed by UV detection at 200 nm. Serum with methylimidazole added as internal standard was deproteinized with acetonitrile and the supernatant, after dilution with water was injected at pressure mode. Creatinine and methylimidazole were baseline-resolved in 6.5 min. Linearity in the 0-880 micromol/L range gave an r2 > or = 0.998, recovery was 102 +/- 2.8% (n = 6). Enzymatic breakdown with creatininase confirmed that serum does not interfere. The within-day and between-days coefficient of variation (CV) were < or = 2.16 and 2.7%, respectively. The accuracy, determined for lyophilized samples by isotope dilution gas chromatography-mass spectrometry was < or = +/- 2.0%. The results were compared with HPLC for 32 lyophilized samples and on 27 serum pools. Capillary electrophoresis, rapid and inexpensive, seems a promising alternative to high-performance liquid chromatography (HPLC) for creatinine determination in human serum.  相似文献   

16.
A direct injection method for large volume samples which avoids severe tailing of the solvent peak has been developed using a packed column injector (up to 100 μl) leading into an ordinary capillary column (0.3 mm i.d.). Modifications are made to the cooler zones of the inlet port and on the carrier gas flow control system. This injection technique is based on the effective use of phase soaking and cold trapping using a retention gap. The large volume of solvent vapor is rapidly purged out of the injector with a higher flow of carrier gas while the solutes trapped at the head of the column are subsequently analyzed with another optimum flow rate. The proposed carrier gas flow regulation system is also compared with conventional split/splitless injection methods.  相似文献   

17.
We report on a series of flow velocity and efficiency profiles, which were measured across the cross section of preparative chromatographic columns packed with different stationary phase materials using computed tomography. It is shown that this non-invasive technique is very useful for visualization of the inner part of a packed column and measurement of the spatial resolved column packing properties. For evaluation of the influence of the particle shape on the velocity distribution and column performance, irregular and spherical reversed phases were studied in detail. The results showed a decreasing velocity towards the column wall most certainly due to a lower permeability. This effect was much less pronounced in the case of spherical particles, indicating a more homogenous packing structure. The influence of the column packing pressure, as a possible measure for improvement of the packing homogeneity was also studied. It was shown that under the same packing conditions spherical particles always lead to a more homogeneous packing. The overall results of this work contribute to the origin of the fact that spherical material is superior to irregular one from the hydrodynamic point of view.  相似文献   

18.
Cyclodextrins and their derivatives are one of the most common and successful chiral selectors. However, there have been few publications about the use of cyclodextrin‐modified monoliths. In this study, organic hybrid monoliths were prepared by the immobilization of derivatized β‐cyclodextrin alone or with l‐ 2‐allylglycine hydrochloride to the polyhedral oligomeric silsesquioxane methacryl substituted monolith. The main topic of this study is a combined system with dual chiral selectors (l‐ 2‐allylglycine hydrochloride and β‐cyclodextrin) as monolithic chiral stationary phase. The effect of l‐ 2‐allylglycine hydrochloride concentration on enantioseparation was investigated. The enantioseparation of the four acidic compounds with resolutions up to 2.87 was achieved within 2.5 min on the prepared chiral monolithic column in capillary liquid chromatography. Moreover, the possible mechanism of enantioseparation was discussed.  相似文献   

19.
Paracetamol, caffeine and ibuprofen are found in over‐the‐counter pharmaceutical formulations. In this work, we propose two new methods for simultaneous determination of paracetamol, caffeine and ibuprofen in pharmaceutical formulations. One method is based on high‐performance liquid chromatography with diode‐array detection and the other on capillary electrophoresis with capacitively coupled contactless conductivity detection. The separation by high‐performance liquid chromatography with diode‐array detection was achieved on a C18 column (250×4.6 mm2, 5 μm) with a gradient mobile phase comprising 20–100% acetonitrile in 40 mmol L?1 phosphate buffer pH 7.0. The separation by capillary electrophoresis with capacitively coupled contactless conductivity detection was achieved on a fused‐silica capillary (40 cm length, 50 μm i.d.) using 10 mmol L?1 3,4‐dimethoxycinnamate and 10 mmol L?1 β‐alanine with pH adjustment to 10.4 with lithium hydroxide as background electrolyte. The determination of all three pharmaceuticals was carried out in 9.6 min by liquid chromatography and in 2.2 min by capillary electrophoresis. Detection limits for caffeine, paracetamol and ibuprofen were 4.4, 0.7, and 3.4 μmol L?1 by liquid chromatography and 39, 32, and 49 μmol L?1 by capillary electrophoresis, respectively. Recovery values for spiked samples were between 92–107% for both proposed methods.  相似文献   

20.
In this second part of the series of investigations involving the postpolymerization modification of a hydroxy monolith (OHM) capillary column, the surface hydroxyl groups were reacted with epoxy biphenyl thus yielding the so‐called Biphenyl OHM capillary column. The modification involved the epoxy ring opening of the 2‐biphenylyl glycidyl ether catalyzed by BF3 and its subsequent reaction with the hydroxyl groups on the OHM precursor surface. The Biphenyl OHM capillary column thus obtained exhibited the typical reversed phase behavior by primarily hydrophobic interactions vis‐à‐vis the homologous series of alkyl benzenes and in addition by π–π interactions toward nitroalkane homologous series via their π‐electron rich nitro groups. This dual retention mechanism was very distinctly observed with a set of PAH solutes in the sense that the k values of the PAH solutes were comparable to those obtained on a more non polar stationary phase, namely the Epoxy OHM C‐16 reported in the preceding article. Other aromatic solutes showed the dual retention mechanism on the Biphenyl OHM capillary including phenols, anilines derivatives, and phenoxy acid herbicides. The Biphenyl OHM capillary exhibited good reproducibility from run‐to‐run, day‐to‐day, and column‐to‐column.  相似文献   