共查询到20条相似文献,搜索用时 15 毫秒
1.
Some insights on the description of gradient elution in reversed‐phase liquid chromatography 下载免费PDF全文
Juan José Baeza‐Baeza María Celia García‐Álvarez‐Coque 《Journal of separation science》2014,37(17):2269-2277
The so‐called “fundamental equation for gradient elution” has been used for modeling the retention in gradient elution. In this approach, the instantaneous retention factor (k) is expressed as a function of the change in the modifier content (φ(ts)), ts being the time the solute has spent in the stationary phase. This approach can only be applied at constant flow rate and with gradients where the elution strength depends on the column length following a f(t?l/u) function, u being the linear mobile phase flow rate, and l the distance from the column inlet to the location where the solute is at time t measured from the beginning of the gradient. These limitations can be solved by using the here called “general equation for gradient elution”, where k is expressed as a function of φ(t,l). However, this approach is more complex. In this work, a method that facilitates the integration of the “general equation” is described, which allows an approximate analytical solution with the quadratic retention model, improving the predictions offered by the “linear solvent strength model.” It also offers direct information about the changes in the instantaneous modifier content and retention factor, and gives a meaning to the gradient retention factor. 相似文献
2.
Reversed‐phase ion‐pair high‐performance liquid chromatography assay of polyprenyl diphosphate oligomer homologues 下载免费PDF全文
A reversed‐phase ion‐pair high‐performance liquid chromatography procedure was developed for the separation of polyprenyl diphosphate oligomer homologues obtained chemically from plant polyprenols. Tetrabutylammonium phosphate was used as the ion‐pair reagent, and the dependence of the separation quality on pH of ion‐pair reagent was investigated for the first time. The procedure is applicable for the control of commercial available polyprenyl monophosphates (the active components of veterinary drugs Phosprenyl and Gamapren) for the possible presence of polyprenyl diphosphate byproducts. 相似文献
3.
Incorporation of ionic liquid into porous polymer monoliths to enhance the separation of small molecules in reversed‐phase high‐performance liquid chromatography 下载免费PDF全文
Jiafei Wang Ligai Bai Zhen Wei Junxiao Qin Yamin Ma Haiyan Liu 《Journal of separation science》2015,38(12):2101-2108
An ionic liquid was incorporated into the porous polymer monoliths to afford stationary phases with enhanced chromatographic performance for small molecules in reversed‐phase high‐performance liquid chromatography. The effect of the ionic liquid in the polymerization mixture on the performance of the monoliths was studied in detail. While monoliths without ionic liquid exhibited poor resolution and low efficiency, the addition of ionic liquid to the polymerization mixture provides highly increased resolution and high efficiency. The chromatographic performances of the monoliths were demonstrated by the separations of various small molecules including aromatic hydrocarbons, isomers, and homologues using a binary polar mobile phase. The present column efficiency reached 27 000 plates/m, which showed that the ionic liquid monoliths are alternative stationary phases in the separation of small molecules by high‐performance liquid chromatography 相似文献
4.
5.
Deping Hu Yuandong Li Hui Zhao Yang Zhao Si Huang Juan Li Zhenjie Li Yuanxing Duan Yingzhuang Chen Jianjun Xia 《Journal of separation science》2020,43(8):1423-1430
An online high‐pH reversed‐phase liquid chromatography× low‐pH reversed‐phase liquid chromatography tandem electrospray ionization mass spectrometry combined with pulse elution gradient in the first dimension was constructed to separate and identify alkaloids from Macleaya cordata (willd.) R. Br. The modulation was performed by using a dual second dimensional columns interface combined with a make‐up dilution pump, which is responsible for dilution and neutralization of the first dimensional effluent, and the dual second dimensional columns integrated the trapping and the separation function to reduce the second dimension system dead volume. Taking advantage of the dissociable characteristics of alkaloids, mobile phases with different pH values were applied in the first dimension (pH 9.0) and the second dimension (pH 2.6) to improve the orthogonality of two‐dimension separation. Besides, the pulse elution gradient in first dimension and second dimensional gradient were carefully optimized and much better separation was achieved compared to the separation with the traditional two‐dimensional liquid chromatography approach. Finally, mass measurement was performed for alkaloids in M. cordata (willd.) R. Br. by coupling proposed two‐dimensional liquid chromatography system with triple quadrupole mass spectrometry, and 39 alkaloids were successfully identified by comparing the obtained result with the former reported results. 相似文献
6.
Separation of polyethylene glycols and maleimide‐terminated polyethylene glycols by reversed‐phase liquid chromatography under critical conditions 下载免费PDF全文
The separation of polyethylene glycols and maleimide‐substituted polyethylene glycol derivatives based on the number of maleimide end‐groups under critical liquid chromatography conditions has been investigated on a reversed‐phase column. The critical solvent compositions for nonfunctional polyethylene glycols and bifunctional maleimide‐substituted polyethylene glycols were determined to be identical at about 40% acetonitrile in water on a reversed‐phase octadecyl carbon chain‐bonded silica column using mixtures of acetonitrile and water of varying composition as the mobile phase at 25°C. The maleimide‐functionalized polyethylene glycols were successfully separated according to maleimide functionality (with zero, one, two, or three maleimide end‐groups, respectively) under the critical isocratic elution conditions without obvious effect of molar mass. The separation was mainly due to the hydrophobic interaction between the maleimide end‐groups and the column packing. Off‐line matrix‐assisted laser desorption/ionization time of flight mass spectrometry was used to identify the repeating units and, especially, the end‐groups of the maleimide‐substituted polyethylene glycols. Liquid chromatography analysis at critical conditions could provide useful information to optimize the synthesis of functional polyethylene glycols. To our knowledge, this is the first report of the baseline separation of maleimide‐functionalized polyethylene glycols based on the functionality independent of the molar mass without derivatization by isocratic elution. 相似文献
7.
Dicationic imidazolium ionic liquid modified silica as a novel reversed‐phase/anion‐exchange mixed‐mode stationary phase for high‐performance liquid chromatography 下载免费PDF全文
Min Sun Juanjuan Feng Xiaojiao Wang Huimin Duan Leilei Li Chuannan Luo 《Journal of separation science》2014,37(16):2153-2159
A dicationic imidazolium ionic liquid modified silica stationary phase was prepared and evaluated by reversed‐phase/anion‐exchange mixed‐mode chromatography. Model compounds (polycyclic aromatic hydrocarbons and anilines) were separated well on the column by reversed‐phase chromatography; inorganic anions (bromate, bromide, nitrate, iodide, and thiocyanate), and organic anions (p‐aminobenzoic acid, p‐anilinesulfonic acid, sodium benzoate, pathalic acid, and salicylic acid) were also separated individually by anion‐exchange chromatography. Based on the multiple sites of the stationary phase, the column could separate 14 solutes containing the above series of analytes in one run. The dicationic imidazolium ionic liquid modified silica can interact with hydrophobic analytes by the hydrophobic C6 chain; it can enhance selectivity to aromatic compounds by imidazolium groups; and it also provided anion‐exchange and electrostatic interactions with ionic solutes. Compared with a monocationic ionic liquid functionalized stationary phase, the new stationary phase represented enhanced selectivity owing to more interaction sites. 相似文献
8.
Comparison of reversed‐phase liquid chromatography and hydrophilic interaction chromatography for the fingerprint analysis of Radix isatidis 下载免费PDF全文
Cong‐En Zhang Yin Xiong Qin Dong Dan Gao Le‐Le Zhang Li‐Na Ma Cheng Peng Xiao‐Ping Dong Dan Yan 《Journal of separation science》2014,37(9-10):1141-1147
Radix isatidis is a famous anti‐influenza virus herbal medicine traditionally taken as a water decoction. However, the chemical fingerprint analysis of Radix isatidis is dominantly based on RPLC, from which it is difficult to obtain fingerprint information of hydrophilic compounds. Here, we developed the separation of Radix isatidis by RPLC and hydrophilic interaction chromatography, comparing the traditional RPLC fingerprint with the hydrophilic interaction chromatography fingerprint. Besides, an anti‐viral assay of Radix isatidis was conducted to evaluate its efficacy. The fingerprint–efficacy relationships between the fingerprints and the anti‐viral activity were further investigated with principal component regression analysis. The results showed that the anti‐viral activity correlated better with the hydrophilic interaction chromatography fingerprint than with the RPLC fingerprint. This study indicates that hydrophilic interaction chromatography could not only be a complementary method to increase the fingerprint coverage of conventional RPLC fingerprint, but also can better represent the efficacy and quality of Radix isatidis. 相似文献
9.
Chromatographic analysis of ionic liquids on different types of packings offers interesting possibility to determine their retention mechanism. As a consequence, the major interactions between stationary phase ligands and analyzed chemical entities can be defined. The main aim of this work was to analyze cations of ionic liquids on chemically bonded stationary phases with specific structural properties. The attempt to predict the main interactions between positive ions of ionic liquids and stationary phase ligands was undertaken. For that purpose, butyl, octyl, octadecyl, phenyl, aryl, mixed, alkylamide, and cholesterolic packings were chosen and applied to the analysis of six most commonly used ionic liquids' cations. Obtained results indicate mainly dispersive and pi-pi type of interaction part in the retention mechanism of analyzed compounds. 相似文献
10.
Summary A computer-assisted method is presented for the optimization of separation in gradient elution reversed-phase HPLC. The method is based on a polynomial estimation from nine preliminary experiments according to a two-factor (initial solvent composition C and gradient time T) rectangular design. This is followed by a two-dimension computer scanning technique. Resolution is used as the selection criterion. Good agreement was obtained between predicted data and experimental results. 相似文献
11.
《Journal of separation science》2018,41(10):2151-2160
In recent years, the use of human saliva for diagnostic purposes has evoked great interest. Thus, the aim of this study was to choose the optimal solid‐phase extraction cartridges and extraction solvents for the quantitation of venlafaxine in saliva. Blank saliva samples spiked with venlafaxine concentrations between 25 and 750 ng/mL were analyzed using five solid‐phase extraction columns (C18, C8, Strata‐X, Strata‐X‐C, and Strata‐X‐AW), washing solvents (deionized water, phosphate buffer at pH 5.5, and their mixtures with methanol), and elution solvents (methanol, acetonitrile, and their mixtures with 25% ammonia). A high‐performance liquid chromatography system was used to quantify venlafaxine in saliva. The results of this study revealed that nine of 25 procedures enabled quantitation of venlafaxine in the tested concentration range. The procedure that used a C18 cartridge, a mixture of methanol and deionized water as the washing solvent, and methanol as the elution solvent was the most effective and allowed quantitation of all venlafaxine concentrations with an acceptable recovery. In contrast, the Strata‐X‐C cartridge could not detect venlafaxine at the lowest concentration (25 ng/mL). The data acquired from the high‐performance liquid chromatography system were confirmed by a multivariate data analysis. 相似文献
12.
Ester Peris‐García Casandra Ortiz‐Bolsico Juan José Baeza‐Baeza María Celia García‐Alvarez‐Coque 《Journal of separation science》2015,38(12):2059-2067
Polyoxyethylene(23)lauryl ether (known as Brij‐35) is a nonionic surfactant, which has been considered as an alternative to the extensively used in micellar liquid chromatography anionic surfactant sodium lauryl (dodecyl) sulfate, for the analysis of drugs and other types of compounds. Brij‐35 is the most suitable nonionic surfactant for micellar liquid chromatography, owing to its commercial availability, low cost, low toxicity, high cloud temperature, and low background absorbance. However, it has had minor use. In this work, we gather and discuss some results obtained in our laboratory with several β‐blockers, sulfonamides, and flavonoids, concerning the use of Brij‐35 as mobile phase modifier in the isocratic and gradient modes. The chromatographic performance for purely micellar eluents (with only surfactant) and hybrid eluents (with surfactant and acetonitrile) is compared. Brij‐35 increases the polarity of the alkyl‐bonded stationary phase and its polyoxyethylene chain with the hydroxyl end group allows hydrogen‐bond interactions, especially for phenolic compounds. This offers the possibility of using aqueous solutions of Brij‐35 as mobile phases with sufficiently short retention times. The use of gradients of acetonitrile to keep the concentration of Brij‐35 constant is another interesting strategy that yields a significant reduction in the peak widths, which guarantee high resolution. 相似文献
13.
Adsorption and recovery issues of recombinant monoclonal antibodies in reversed‐phase liquid chromatography† 下载免费PDF全文
Szabolcs Fekete Alain Beck Elsa Wagner Karine Vuignier Davy Guillarme 《Journal of separation science》2015,38(1):1-8
The poor recovery of large biomolecules is a well‐known issue in reversed‐phase liquid chromatography. Several papers have reported this problem, but the reasons behind this behavior are not yet fully understood. In the present study, state‐of‐the‐art reversed‐phase wide‐pore stationary phases were used to evaluate the adsorption of therapeutic monoclonal antibodies. These biomolecules possess molar mass of approximately 150 000 g/mol and isoelectric points between 6.6 and 9.3. Two types of stationary phases were tested, the Phenomenex Aeris Widepore (silica based), with 3.6 μm superficially porous particles, and the Waters Acquity BEH300 (ethylene‐bridged hybrid), with 1.7 μm fully porous particles. A systematic investigation was carried out using 11 immunoglobulin G1, G2, and G4 antibodies, namely, panitumumab, natalizumab, cetuximab, bevacizumab, trastuzumab, rituximab, palivizumab, belimumab, adalimumab, denosumab, and ofatumumab. All are approved by the Food and Drug Administration and the European Medicines Agency in various therapeutic indications and are considered as reference antibodies. Several test proteins, such as human serum albumin, transferrin, apoferritin, ovalbumin, and others, possessing a molar mass between 42 000 and 443 000 g/mol were also evaluated to draw reliable conclusions. The purpose of this study was to find a correlation between the adsorption of monoclonal antibodies and their physicochemical properties. Therefore, the impact of isoelectric point, molar mass, protein glycosylation, and hydrophobicity was investigated. The adsorption of intact antibodies on the stationary phase was significantly higher than that of proteins of similar size, isoelectric point, or hydrophobicity. The present study also demonstrates the unique behavior of monoclonal antibodies, contributing some unwanted and unpredictable strong secondary interactions. 相似文献
14.
Solute migration in a chromatographic column is an important consideration when designing batch or continuous chromatographic separation processes. Most design methods for the chromatographic processes are based on the equilibrium theory which concerns only the migration velocity of the solute. However, in real cases, it is important to predict the zone spreading which occurs by axial dispersion and mass transfer resistance. To predict the actual solute profiles in the column or effluent stream, numerical methods to solve nonlinear partial differential equations have been used. However, these methods involve much time and expense. In this work, two different rate factors are considered to predict the characteristics of the solute profiles. The first is solute migration velocity and the second is the zone spreading rate. The zone spreading rate can be estimated by the apparent axial dispersion coefficient which is obtained from the height of the equivalent theoretical plate in particular. Four benzene derivatives (benzene, toluene, p‐xylene, and acetophenone) were used as model solutes, and two mobile phase systems, water/methanol and water/ACN, were used in RP‐HPLC. The bandwidths and retention times of the solutes were predicted under several linear gradient conditions. The predicted and experimental bandwidths and retention times showed good agreement. 相似文献
15.
Xiang Wang Shanshan Zhao Chaoyue Wang Wenyu Sun Yang Jin Xingchu Gong Shengqiang Tong 《Journal of separation science》2020,43(3):561-568
Off‐line comprehensive two‐dimensional reversed‐phase countercurrent chromatography with high‐performance liquid chromatography was investigated in separation of crude ethanol extract from traditional Chinese medicinal herb Polygonum cuspidatum Sieb. et Zucc. Two‐dimensional contour plots for countercurrent chromatography with high‐performance liquid chromatography was obtained after comprehensive separation was completed. Total peak capacity was evaluated and approximately 810 peaks were obtained through a comprehensive two‐dimensional separation. A highly orthogonality of 52.23% and a large separation space occupancy of 88.86% were achieved. Meanwhile, it was found that several components could be well separated by countercurrent chromatography while they could not be separated by high‐performance liquid chromatography, and vice versa, which further indicated the orthogonality of the two separation methods. The off‐line comprehensive two‐dimensional countercurrent chromatography with high‐performance liquid chromatography provided a promising and powerful method for separation of complex natural products. 相似文献
16.
(R)‐(+)‐naphthylethyl amine and (S)‐(+)‐1‐benzyl‐3‐aminopyrrolidine were incorporated as chiral auxiliaries, by nucleophilic substitution of chlorine atoms, in cyanuric chloride (CC) or its 6‐butoxy derivative. There were obtained four new chiral derivatizing reagents (CDRs) as two dichloro and two monochloro triazine reagents. The CDRs so obtained were characterized and their optical purity was ascertained. Diastereomers of dl ‐selenomethionine were synthesized under microwave irradiation for 60 or 90 s (at 80% power of 800 W). Reversed‐phase high‐performance liquid chromatographic separation of diastereomers was carried out on a C18 column using mixtures of acetonitrile with aqueous trifluoroacetic acid as mobile phase. The detection was made at 230 nm using a photodiode array detector. The separation behaviors in terms of retention times and resolutions were compared. The separation method was validated for limit of detection, linearity, accuracy, precision, and recovery. Copyright © 2013 John Wiley & Sons, Ltd. 相似文献
17.
《Journal of separation science》2018,41(15):3121-3128
Sarcosine is a potential prostate cancer marker. In this study, we developed a method of three‐phase solvent bar liquid‐phase microextraction combined with high‐performance liquid chromatography to determine sarcosine after derivatization with 4‐dimethylarminoazobenzene‐4‐sulfonyl chloride from human urine. The effects of different extraction conditions on extraction efficiency were investigated and optimized. Under optimum experimental conditions, a calibration graph exhibited linearity over the range of 0.05–25 μmol/L with a correlation coefficient (r2) of 0.9990. The enrichment factor was 168, and the detection limit was 0.02 μmol/L. The method was successfully used to analyze sarcosine in human urine and non‐invasive detection, and good spiked recoveries ranging from 90.5 to 93.6% were obtained. The proposed method exhibited high sensitivity, high enrichment factor, good precision, and a simple setup. It may contribute to the early accurate diagnosis and the progression monitoring of prostatic carcinoma. 相似文献
18.
Dan Liu Zhiguo Su Changhai Wang Ming Gu Siliang Xing 《Journal of separation science》2010,33(15):2266-2271
Three hydrolyzable tannins, geraniin, corilagin and gallic acid, main active components of Geranium wilfordii Maxim, have been separated and purified in one‐step by both reversed‐phase and normal‐phase high‐speed counter‐current chromatography. Gallic acid, corilagin and geraniin were purified from 70% aqueous acetone extract of G. wilfordii Maxim with solvent system n‐hexane–ethyl acetate–methanol–acetic acid–water (1:10:0.2:0.2:20) by reversed‐phase high‐speed counter‐current chromatography at purities of 94.2, 91.0 and 91.3%, at yields of 89.3, 82.9 and 91.7%, respectively. Gallic acid, corilagin and geraniin were purified with solvent system n‐hexane–ethyl acetate–methanol–acetic acid–water (0.2:10:2:1:5) by normal‐phase high‐speed counter‐current chromatography at purities of 85.9, 92.2 and 87.6%, at yields of 87.4, 94.6 and 94.3%, respectively. It was successful for both reversed‐phase and normal‐phase high‐speed counter‐current chromatography to separate high‐polarity of low‐molecular‐weight substances. 相似文献
19.
Imidazolium‐embedded iodoacetamide‐functionalized silica‐based stationary phase for hydrophilic interaction/reversed‐phase mixed‐mode chromatography 下载免费PDF全文
Huizhen Wang Lu Zhang Teng Ma Liyuan Zhang Xiaoqiang Qiao 《Journal of separation science》2016,39(18):3498-3504
A novel imidazolium‐embedded iodoacetamide‐functionalized silica‐based stationary phase has been prepared by surface radical chain‐transfer polymerization. The stationary phase was characterized by Fourier transform infrared spectrometry, thermogravimetric analysis, and element analysis. Fast and efficient separations of polar analytes, such as nucleosides and nucleic acid bases, water‐soluble vitamins and saponins, were well achieved in hydrophilic interaction chromatography mode. Additionally, a mixed mode of hydrophilic interaction and reversed‐phase could be also obtained in the analysis of polar and nonpolar compounds, including weak acidic phenols, basic anilines and positional isomers, with high resolution and molecular‐planarity selectivity, outperforming the commercially available amino column. Moreover, simultaneous separation of polar and nonpolar compounds was also achieved. In conclusion, the multimodal retention capabilities of the imidazolium‐embedded iodoacetamide‐functionalized silica‐based column could offer a wide range of retention behavior and flexible selectivity toward hydrophilic and hydrophobic compounds. 相似文献
20.
Fast determination of ginsenosides in ginseng by high‐performance liquid chromatography with chemometric resolution 下载免费PDF全文
Ginseng is a well‐known traditional Chinese medicinal herb, and ginsenosides are its major active components. A method for the fast determination of ginsenosides in ginseng samples by high‐performance liquid chromatography was developed and used for the quantitative analysis of four ginsenosides in three different ginseng samples. In this method, instead of time‐consuming gradient elution, isocratic elution was used to speed up the analysis. Under strong isocratic elution, all the ginsenosides are eluted in 2.3 min. Although the measured signal is composed of overlapped peaks with the interferences and background, the signal of ginsenosides can be extracted by chemometric resolution. A non‐negative immune algorithm was employed to obtain the chromatographic information of the target components from the data. Compared with conventional chemometric approaches, the method can perform the extraction for one‐dimensional overlapping signals. The method was validated by the determination of four ginsenosides in three different ginseng samples. The recoveries of the spiked samples were in the range of 94.08–107.3%. 相似文献