共查询到20条相似文献,搜索用时 15 毫秒
1.
This study describes an SPE coupled with large volume injection (LVI) analytical method for the analysis of organochlorine pesticides, BHC (alpha, beta, delta), aldrin, endosulfan (alpha, beta), endrin, dieldrin, and DDT, from aqueous samples. Determination was carried out by GC with MS. The LODs of organochlorine pesticides were determined at 10 ng/L concentration levels, and the results show that SPE-LVI-GC/MS has the potential to accurately determine organochlorine pesticides in water, as it avoids analyte classes in the various steps of a typical extraction procedure. 相似文献
2.
Lin Liu Yang Jiang Li Yong Bin Hu Lan Zhu Yan Wang 《International journal of environmental analytical chemistry》2018,98(8):743-757
A method for simultaneous determination of 11 organophosphorus pesticides residues in river water by MWCNTs-solid phase extraction combined with ultra-high performance liquid chromatography/tandem mass spectrometry was developed. After centrifugation and filtration, the target pesticides were enriched with MWCNTs-SPE cartridge. Then the pesticides adsorbed on MWCNTs were eluted with ethyl acetate and dichloromethane, the eluent was dried-up under nitrogen flow and the residue was dissolved in methanol-water (1:1, v/v) as sample solution. The separation was accomplished on a C18 column with the mobile phase consisting of methanol and 0.1% formic acid at 0.20 mL/min in gradient elution. The pesticides were detected in multiple reaction monitoring mode by a triple quadruple mass spectrometer. Good linearities were obtained within 1–200 ng/L, with the correlation coefficients greater than 0.998. The detection and quantification limits were in the ranges of 0.02–1.00 ng/L and 0.07–3.33 ng/L, respectively. The recoveries and relative standard deviations were in the range of 88.3–124.9% and 0.12–20.5%, respectively. The method has been successfully applied to the detection of 34 urban river water samples from Chengdu, China and 7 organophosphorus pesticides were detected with the concentrations of 0.32–211 ng/L. 相似文献
3.
Fang Zhu 《Analytica chimica acta》2009,650(2):202-196
A method based on solid-phase microextraction (SPME) and gas chromatography with mass spectrometry (GC/MS) for the determination of 18 organophosphorus pesticides (OPPs) in textiles is described. Commercially available SPME fibers, 100 μm PDMS and 85 μm PA, were compared and 85 μm PA exhibited better performance to the OPPs. Various parameters affecting SPME, including extraction and desorption time, extraction temperature, salinity and pH, were studied. The optimized conditions were: 35 min extraction at 25 °C, 5% NaSO4 content, pH 7.0, and 3.5 min desorption in GC injector port at 250 °C. The linear ranges of the SPME-GC/MS method were 0.1-500 μg L−1 for most of the OPPs. The limits of detection (LODs) ranged from 0.01 μg L−1 (for bromophos-ethyl) to 55 μg L−1 (for azinphos-methyl) and the RSDs were between 0.66% and 9.22%. The optimized method was then used to analyze 18 OPPs in textile sample, and the determined recoveries were ranged from 76.7% to 126.8%. Moreover, the distribution coefficients of the OPPs between 85 μm PA fiber and simulative sweat solution (Kpa/s) were determined. The determined Kpa/s of the OPPs correlated well with their octanol-water partition coefficients (r = 0.764 and 0.678) and water solubility (r = −0.892 and −0.863). 相似文献
4.
基于碳纳米管修饰电极检测有机磷农药的生物传感器 总被引:5,自引:0,他引:5
报道了一种用于检测有机磷农药的安培型生物传感器,利用戊二醛交联法将乙酰胆碱酯酶和牛血清白蛋白固定在羧基化多壁碳纳米管修饰玻碳电极表面,制备了可应用于检测有机磷农药的新型生物传感器,并确定了最佳工作条件.该方法具有良好的重现性和回收率,当辛硫磷及氧化乐果的浓度分别在5.0×10-4~5.0×10-1 g/L和1.0×10-3~5.0×10-1 g/L范围内时,抑制率与其浓度的对数呈线性关系,检出限按抑制率为10%时的农药浓度计算,可分别达到3.6×10-4 g/L和5.9×10-4 g/L. 相似文献
5.
Katia Buonasera Giovanni D’Orazio Salvatore Fanali Paola Dugo Luigi Mondello 《Journal of chromatography. A》2009,1216(18):3970-3976
In the present research, the separation of a series of organophosphorus pesticides (fensulfothion, fenamiphos, profenofos, fonofos, isofenphos, dialifos, sulprofos and prothiofos), by using nano-liquid chromatography (nano-LC) with UV detection is described. Three 100 μm ID capillary columns, packed with different silica-based stationary phases (CN, C18, and phenyl), were investigated. Among these, the phenyl column offered the best results in terms of chromatographic performance, and was selected for pesticide analyses. Parameters, such as sample dilution solvent, injection volume, mobile phase composition and flow rate, were optimized in order to define the ideal experimental conditions. With the aim of improving sensitivity, on-column focusing of large injection volumes was applied: a sensitivity increase of circa 100-fold was attained, with limits of detection (LODs) and quantification (LOQs) within the 4.4–37.5 and 14.5–125.0 ng/mL ranges, respectively. The method was validated, with satisfactory results, through the measurement of the following parameters: limits of detection and quantification, precision, linearity and recovery. Finally, five different baby foods, previously fortified with a solution of the eight aforementioned pesticides, and then subjected to liquid–liquid extraction and solid-phase extraction clean-up, were analyzed. 相似文献
6.
建立了快速溶剂萃取(ASE)-气相色谱-串联质谱(GC-MS/MS)同时分析土壤中8种有机氯农药(OCPs)和5种有机磷农药(OPPs)的方法。样品由正己烷-丙酮(1:1,v/v)溶液萃取,经无水硫酸钠脱水、氮吹仪浓缩后,采用硅胶(Si)固相萃取小柱进行净化,正己烷-丙酮(1:1,v/v)溶液进行洗脱,然后经HP-5MS色谱柱(30 m×0.25 mm×0.25 μm)分离,在电子轰击电离源下以多反应监测(MRM)模式进行检测,内标法定量。分析结果表明,13种目标物在1.00~100 μg/L范围内线性关系良好,相关系数(R)大于0.995;加标回收率为66.8%~88.4%,能够实现准确定量;日内精密度与日间精密度均小于10%。当取样量为10.0 g时,8种OCPs的方法检出限为0.02~0.04 μg/kg,5种OPPs的方法检出限为0.06~0.12 μg/kg,能够满足土壤农药残留的检测要求。 相似文献
7.
Ravelo-Pérez LM Hernández-Borges J Angel Rodríguez-Delgado M 《Journal of separation science》2008,31(20):3612-3619
In the present work, a GC method with nitrogen-phosphorus detection (NPD) was developed for the simultaneous determination of eight organophosphorus pesticide (OPP) residues (i.e., ethoprofos, diazinon, chlorpyrifos-methyl, fenitrothion, malathion, chlorpyrifos, fenamiphos, and buprofezin) in water samples. Preconcentration of the water samples was carried out using an SPE procedure with multiwalled carbon nanotubes (MWCNTs) of 10-15 nm od, 2-6 nm id, and 0.1-10 microm length as stationary phase. Extraction parameters, such as the amount of MWCNTs, sample volume, pH, and type and amount of the eluent were optimized. The most favorable conditions were as follows: 40 mg MWCNTs, 800 mL water, pH 6.0, and 20 mL dichloromethane, respectively. The MWCNTs-SPE-GC-NPD method was applied to the determination of these pesticides in real water samples: mineral and ground water as well as run-off water from an agricultural area collected shortly before opening out onto the sea. A recovery study was developed with five consecutive extractions of the three types of water spiked at three concentration levels (n = 15). Mean recovery values were in the range of 75-116% for mineral water (RSD < 6.3%), 67-119% for ground water (RSD < 5.8%), and 57-81% for run-off waters (RSDs < 6.9%), except for fenamiphos (mean recovery values between 40 and 84% for the three types of waters, RSDs < 8.9%). LODs were in the low ng/L level (i.e., levels below the maximum residue limits (MRLs) established by the European Union (EU) legislation for these compounds in waters). The proposed method was also applied to the analysis of six water samples (two of each type: mineral, ground, and run-off waters) in which no residues of the selected pesticides were found. Results show that the MWCNTs used in this work have a high adsorbability of the pesticides under study. The main advantage of the use of these MWCNTs is their low cost when compared with those MWCNTs previously used in the literature and with conventional SPE cartridges. 相似文献
8.
羟基化多壁碳纳米管分散固相萃取-气相色谱-质谱法测定茶叶中21种有机磷农药 总被引:1,自引:0,他引:1
建立了用羟基化多壁碳纳米管(MWCNTs-OH)、N-丙基乙二胺键合固相吸附剂(PSA)和MgSO4作为吸附剂的改进QuEChERS-气相色谱-质谱快速检测茶叶中21种有机磷农药的方法。茶叶中残留的农药经正己烷-丙酮(2 : 1, v/v)混合溶剂提取,以MWCNTs-OH、PSA和MgSO4去除杂质,离心、过滤后经气相色谱-电子轰击源质谱测定,外标法定量。结果表明,目标化合物在0.01~0.50 mg/kg范围内的线性关系良好。空白茶叶样品在低、中、高3个添加水平下的平均回收率为81.5%~109.4%,相对标准偏差(n=5)为2.3%~10.6%,定量限为0.001~0.040 mg/kg。该方法操作简单、快速、灵敏、成本低,能满足茶叶中常见有机磷农药残留的检测要求。 相似文献
9.
Summary A fast and simple procedure for the analysis of aqueous samples by on-line membrane disk extraction and capillary gas chromatography (GC) is presented. As an example, organophosphorus pesticides are preconcentrated from aqueous samples on three 0.5 mm thick, 4.2 mm diameter extraction disks. The layers are dried by a stream of nitrogen (10–15 min; ambient temperature). Desorption of the analytes is carried out with ethyl acetate which is directly introduced into a retention gap under partially concurrent solvent evaporation conditions, using an early solvent vapour exit. The final analysis is carried out by GC with thermionic detection. The technique is applied to the determination of a series of organophosphorus pesticides in tap water and water from two European rivers. With a sample volume of only 2.5 ml, detection limits of 10–30 ppt are achieved in tap water and of 50–100 ppt in river water. 相似文献
10.
Yanuardi Raharjo Mohd Marsin Sanagi Wan Aini Wan Ibrahim Ahmedy Abu Naim Hassan Y. Aboul‐Enein 《Journal of separation science》2009,32(4):623-629
A liquid‐phase microextraction coupled with LC method has been developed for the determination of organophosphorus pesticides (methidation, quinalphos and profenofos) in drinking water samples. In this method, a small amount (3 μL) of isooctane as the acceptor phase was introduced continually to fill‐up the channel of a 1.5 cm polypropylene hollow fiber using a microsyringe while the hollow fiber was immersed in an aqueous donor solution. A portion of the acceptor phase (ca. 0.4 μL) was first introduced into the hollow fiber and additional amounts (ca. 0.2 μL) of the acceptor phase were introduced to replenish at intervals of 3 min until set end of extraction (40 min). After extraction, the acceptor phase was withdrawn and transferred into a 2 mL vial for a drying step prior to injection into a LC system. Parameters that affect the extraction efficiency were studied including the organic solvent, length of fiber, volume of acceptor and donor phase, stirring rate, extraction time, and effect of salting out. The proposed method provided good enrichment factors of up to 189.50, with RSD ranging from 0.10 to 0.29%, analyte recoveries of over 79.80% and good linearity ranging from 10.0 to 1.25 mg/L. The LOD ranged from 2.86 to 82.66 μg/L. This method was applied successfully to the determination of organophosphorus pesticides in selected drinking water samples. 相似文献
11.
《Journal of separation science》2017,40(7):1564-1571
A sensitive method for the determination of six varying polarity pesticides (imidacloprid, acetamiprid, carbendazim, simazine, linuron, and tebufenozide) based on a solid‐phase extraction disk with multiwalled nanotubes is proposed.A dispersion of multiwalled nanotubes in a surfactant aqueous solution (Triton X‐100) was used for the preparation of the solid‐phase extraction disk. The effect of surfactant on the functional groups of multiwalled nanotubes was examined by applying temperature‐programmed desorption. It was found that this treatment increased the amount of oxygen groups of treated multiwalled nanotubes comparing with untreated ones. The factors that may influence the adsorption and recovery such as the kind and volume of eluent, volume, flow rate and pH of sample were investigated and optimized. Under the optimized conditions, the maximal enrichment factors for low polar pesticides are ranging from 4000 to 4985 and for more polar are 2250 and 2750. The linear range of calibration curves was 10–500 ng/L with correlation coefficient higher than 0.9960, and the detection limit was 6.2–23.7 ng/L. Finally optimized method was applied for determination trace level of five out of six pesticides in tap and river water samples with good recovery. 相似文献
12.
《Journal of separation science》2018,41(14):2934-2941
The precise control of pesticide residues in foodstuffs depends significantly on the clean extraction of analytes using specifically designed separation methods. In this study, a one‐pot sol–gel process was used for the preparation of a magnetic hybrid silica gel tetraethylortho silicate‐cyanopropyltriethoxy silane nanocomposite. The prepared material was characterized using energy dispersive X‐ray spectroscopy, Fourier transform infrared spectroscopy, single‐point specific surface area, and scanning electron microcopy. The synthesized magnetic hybrid material was used as a solid phase extraction sorbent for the extraction and preconcentration of some organophosphorus pesticides before gas chromatography with a microelectron capture detector. The performance of the proposed magnetic solid‐phase extraction technique was validated by linearity (0.05–2 ng/mL), correlation coefficients (r2 = 0.9993–0.9997), limit of detection (0.02–0.06 ng/mL, S/N = 3, n = 3), and intraday (RSD = 1.5–8.7%, n = 3) and interday precision (RSD = 5.5–9.3%, n = 12), while the recovery in real samples and equilibrium adsorption capacity was 72.02–103.84% and 8–20 mg/g, respectively. The magnetic solid‐phase extraction based on the hybrid nanocomposite revealed a high enrichment factor, an appropriate dynamic range, and great absorptive ability toward the selected organophosphorus pesticides spiked in real water samples. 相似文献
13.
Viorica Lopez-Avila Richard Young Werner F. Beckert 《Journal of separation science》1997,20(9):487-492
This paper describes the extraction of 49 organophosphorus pesti-cides (OPPs) from water samples using solid-phase microextraction (SPME). Three fibers, including a 15-μm XAD-coated fiber, a 85-μm polyacrylate-coated fiber, and a 30-μm polydimethylsilox-ane-coated fiber (PDMS), were evaluated here. The effects of stirring and the addition of NaCl to the sample were examined for the polyacrylate-coated fiber. The precision of the technique was examined for all three fibers and the extraction kinetics were investigated using the XAD- and polyacrylate-coated fibers. With some exceptions, the XAD- and polyacrylate-coated fibers performed better than the PDMS-coated fiber. The superiority of the XAD-nd polyacrylate-coated fiber. The superiority of the XAD- and polyacrylate-coated fibers over the PDMS-coated fibers can be attribuibuted to the aromatic functionalities of the XAD and the polar functionalities in the polyacrylate. The relatively high percent RSDs indicate that the SPME technique needs to be further refined before it can be used for anything other than screening. A more effective form of agitation than mechanical stirring may be neccessary to reduce variability and achieve a faster equilibrium between the sample and the SPME fiber. 相似文献
14.
《Journal of separation science》2017,40(23):4583-4590
A fast and sensitive analytical method based on stir bar sorptive extraction technology with gas chromatography and mass spectrometry was developed to simultaneously analyze 18 kinds of polychlorinated biphenyls and 20 kinds of organochlorine pesticides in aqueous samples. A long adsorption time and small sample volume, which are problems encountered in conventional methods of stir bar sorptive extraction, were effectively solved by simultaneously using multiple stir bars for enrichment with sequential cryofocusing and merged injection. Optimized results showed good linear coefficients in the range of 10–500 ng/L and the method detection limits of 0.12–2.07 ng/L for polychlorinated biphenyls and organochlorine pesticides. The recovery ratios of the spiked samples at different concentrations were between 64.7 and 111.0%, and their relative standard deviations ranged from 0.9 to 17.6%. Four types of the studied compounds were determined in Qiantang River water samples, and their contents were between 0.82 and 5.00 ng/L. 相似文献
15.
Wei Zuo Chao Dong Bining Jiao Chengqiu Wang Jing Li 《Journal of separation science》2022,45(13):2190-2199
A rapid and cost-effective analytical method based on ultrahigh-performance liquid chromatography-tandem mass spectrometry was designed and verified for simultaneously monitoring the novel acaricide pyflubumide and its metabolite (pyflubumide-des(2-methyl-1oxopropyl)) in vegetables and fruits. After the extraction with acetonitrile, the samples were purified by dispersive solid-phase extraction with multi-walled carbon nanotubes. Detection of the two target analytes was achieved within 3.0 min using a positive electrospray ionization mode. The average recovery, intra-day precision, and inter-day precision of the two analytes at three spiked levels (2, 20, and 100 μg/kg) were 75.0–101.0, 0.4–4.4, and 0.6–5.3%, respectively. The limit of quantification of two compounds was 2 μg/kg, which was far below the maximum residue limits of pyflubumide in foods established by Japan and South Korea. Finally, the concentrations of pyflubumide and its metabolite in the samples were 16.6 and 7.8 μg/kg respectively, which verified the practicability and reliability of the method. The method was used to efficiently detect pyflubumide and its metabolite in real samples and was confirmed to be robust and effective for routinely analyzing both pyflubumide and its metabolite in vegetable and fruit samples. 相似文献
16.
固相微萃取-气相色谱-质谱联用分析环境水样中痕量有机磷农药 总被引:10,自引:0,他引:10
研究了固相微萃取(SPME) 气相色谱 质谱联用(GC MS)同时测定环境水样中二嗪农、甲基对硫磷、对硫磷和水胺硫磷4种有机磷农药(OPPs)的分析方法。选择聚丙烯酸酯(PA)萃取纤维,对SPME的条件如萃取时间、萃取溶液的pH值和离子强度、解吸温度、解吸时间和GC MS的条件进行了优化。对二嗪农和水胺硫磷方法线性范围为0.001~10μg L,对甲基对硫磷和对硫磷方法线性范围为0.001~100μg L。二嗪农、甲基对硫磷、对硫磷、水胺硫磷的检出限分别为0.015,0.020,0.013和0.039μg L。分析加标自来水、矿泉水和湖水样品,回收率在89.0%~102%之间,RSD在2.1%~14.1%之间。适合于环境水样中痕量OPPs的快速分析。 相似文献
17.
Gas chromatography-mass spectrometry (GC-MS) with electron impact (EI), positive-ion chemical ionization (PCI) and negative-ion chemical ionization (NCI) were applied as confirmatory techniques for residue analysis of chlorotriazine pesticides, their degradation products and organophosphorus pesticides in soil samples. Clean-up was effected using a Florisil column with subsequent analysis by GC with a nitrogen-phosphorus detector. GC-MS with the EI mode of operation is the common mode of confirmation for all the pesticides. Further confirmation by either GC-MS with PCI and NCI for chlorotriazines and organophosphorus pesticides, respectively, is recommended. The method was applied to the determination of residue levels of atrazine, deethylatrazine, deisopropylatrazine, simazine, fenitrothion and tetrachlorvinphos in several soil samples at levels from 5 ng g?1 to 9 μg g?1. 相似文献
18.
19.
Ultrapreconcentration and determination of organophosphorus pesticides in water by solid‐phase extraction combined with dispersive liquid–liquid microextraction and high‐performance liquid chromatography 下载免费PDF全文
Junhua Chen Guangming Zhou Yongli Deng Hongmei Cheng Jie Shen Yi Gao Guilong Peng 《Journal of separation science》2016,39(2):272-278
Solid‐phase extraction coupled with dispersive liquid–liquid microextraction was developed as an ultra‐preconcentration method for the determination of four organophosphorus pesticides (isocarbophos, parathion‐methyl, triazophos and fenitrothion) in water samples. The analytes considered in this study were rapidly extracted and concentrated from large volumes of aqueous solutions (100 mL) by solid‐phase extraction coupled with dispersive liquid–liquid microextraction and then analyzed using high performance liquid chromatography. Experimental variables including type and volume of elution solvent, volume and flow rate of sample solution, salt concentration, type and volume of extraction solvent and sample solution pH were investigated for the solid‐phase extraction coupled with dispersive liquid–liquid microextraction with these analytes, and the best results were obtained using methanol as eluent and ethylene chloride as extraction solvent. Under the optimal conditions, an exhaustive extraction for four analytes (recoveries >86.9%) and high enrichment factors were attained. The limits of detection were between 0.021 and 0.15 μg/L. The relative standard deviations for 0.5 μg/L of the pesticides in water were in the range of 1.9–6.8% (n = 5). The proposed strategy offered the advantages of simple operation, high enrichment factor and sensitivity and was successfully applied to the determination of four organophosphorus pesticides in water samples. 相似文献
20.
固相萃取-液相色谱-串联质谱法测定蔬菜中4种有机磷农药及其代谢产物 总被引:2,自引:0,他引:2
在蔬菜种植中经常使用的有机磷农药马拉硫磷、甲基对硫磷、敌百虫及乙酰甲胺磷可能转化的主要代谢产物分别为O,O-二甲基二硫代磷酸酯、对硝基酚、敌敌畏及甲胺磷。根据蔬菜色素等基质的含量不同采用不同的净化方法,色素含量高的蔬菜采用活性炭和弗罗里硅土串联固相萃取小柱净化,其他蔬菜采用弗罗里硅土固相萃取小柱净化。色谱分离选择ACQUITY UPLC BEH HILIC色谱柱,以乙腈和5 mmol/L乙酸铵水溶液为流动相进行梯度洗脱,得到的分离效果较好;质谱采用电喷雾正或负离子电离、多反应监测模式检测。液相色谱-质谱检测的基质效应为15.3%~45.1%;4种有机磷农药及其代谢物的方法回收率为76.9%~102.8%,相对标准偏差为5.92%~10.19%;定量限范围为0.001~0.01 mg/L;在0.01~1.00 mg/L范围内线性相关系数为0.9982~0.9999。方法具有良好的回收率、相对标准偏差、定量限及线性关系,适合蔬菜中有机磷及代谢物的检测,应用该检测方法对农贸市场购买的白菜、辣椒、西红柿及洋葱进行了检测。 相似文献