首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
An efficient separation process of flavonoid from Taxus wallichiana var. mairei remainder extracts free of taxoids was developed in this study. AB‐8 macroporous resin and polyamide resin offered the fine adsorption capacity, and its adsorption rate at 30°C fitted well to the Langmuir and Freundich isotherms. Resin dynamic adsorption and desorption experiments were conducted to optimize the separation process of total flavonoids from T. wallichiana var. mairei remainder extracts free of taxoids. The optimum parameters for adsorption by AB‐8 resin were as follows: (1) the concentration of flavonoids in a sample solution of 5.61 mg/mL with a processing volume of 2 bed volume (BV) (60 mL); (2) for desorption, ethanol–water (80:20, v/v), with 6 BV as an eluent at a flow rate of 2 BV/h. After a one‐run treatment with AB‐8 resin, the content of flavonoids was increased 5.10‐fold from 4.05 to 20.65%. The optimum parameters for adsorption by polyamide resin were as follows: processing volume of 2 BV (30 mL); for desorption, ethanol–water (70:30, v/v), with 8 BV as an eluent at a flow rate of 2 BV/h. After one‐run treatment with polyamide resin, the content of total flavonoids increased from 20.65 to 65.21%. The method will provide a potential approach for large‐scale separation and purification of flavonoid for its wide pharmaceutical use.  相似文献   

2.
Anthocyanins have attracted attention over the past several decades because of their beneficial health effects. In this research, a strategy combining column chromatography and high‐speed countercurrent chromatography was developed for the separation of high‐purity anthocyanin monomers from mulberry fruits. After purification using Amberlite XAD‐7HP column with 80% ethanol (0.1% HCl), a fraction of anthocyanins mixtures with a purity of 68.6% was obtained. High‐speed countercurrent chromatography with a biphasic solvent system of n‐butanol/methyl tert‐butyl ether/acetonitrile/water/trifluoroacetic acid (30:10:10:50:0.05, v/v) was used to separate the anthocyanin monomers. Three monomers of delphinidin‐3‐O‐ rutinoside, cyanidin‐3‐O‐ rutinoside, and cyanidin‐3‐O‐ glucoside were obtained, and identified by 1H and 13C NMR spectroscopy and high‐performance liquid chromatography with electrospray ionization‐mass spectrometry. The method developed in this work can be used to conduct large‐scale separations of anthocyanin monomers from mulberry fruits and other plants.  相似文献   

3.
Three techniques (liquid–liquid extraction, packed bed adsorption and expanded bed adsorption) have been compared for the purification of flavonoids from the leaves of Ginkgo biloba L. A crude Ginkgo extract was obtained by refluxing with ethanol for 3 h. The yield of flavonoids achieved by this crude extraction was about 19% (w/w) and the purity of flavonoids in the concentrated extract was between 1.9 and 2.3% (w/w). The crude extract was then dissolved in deionized water and centrifuged where necessary to prepare clarified feedstock for further purification. For the method using liquid–liquid extraction with ethyl acetate, the purity, concentration ratio and yield of flavonoids were 25.4–31.0%, 16–18 and >98%, respectively. For the method using packed bed adsorption, Amberlite XAD7HP was selected as the adsorbent and clarified extract was used as the feedstock. The dynamic adsorption breakthrough curves and elution profiles were measured. For a feedstock containing flavonoids at a concentration of 0.25 mg/mL, the appropriate loading volume to reach a 5% breakthrough point during the adsorption stage was estimated to be 550–600 mL for a packed bed of volume 53 mL and a flow rate of 183 cm/h. The results from the elution stage indicated that the majority of impurities were eluted by ethanol concentrations of 40% (v/v) or below and efficient separation of flavonoids from the impurities could be achieved by elution of the flavonoids with 50–80% ethanol reaching an average purity of ∼25%. The recovery yield of flavonoids using the packed bed purification method was about 60% of the flavonoids present in the clarified feedstock (corresponding to around 30% for the total flavonoids in the unclarified crude extract). For the method using expanded bed adsorption also conducted with Amberlite XAD7HP as the adsorbent, the optimal operation conditions scouted during the packed bed experiments were used but unclarified crude extract could be loaded directly into the column. For an expanded bed with a settled bed height of 30 cm, the loss of flavonoids in the column flow-through was about 30%. The two-step elution protocol again proved to be effective in separating the adsorbed impurities and flavonoids. More than 96% of the bound impurities were completely removed by 40% ethanol in the first elution stage and less than 4% remained in the final product eluted by 90% ethanol in the second elution stage. Also, ∼74% of the adsorbed flavonoids on column (corresponding to 51% of the total flavonoids in the unclarified feedstock) were recovered in the product. In addition to higher recovery yield, the average process time to obtain the same amount of product was decreased in the expanded bed adsorption (EBA) process. The results suggest that the adoption of EBA procedures can greatly simplify the process flow sheet and in addition reduce the cost and time to purify flavonoids from Ginkgo biloba. These results clearly demonstrate the potential for the use of EBA to purify pharmaceuticals from plant sources.  相似文献   

4.
Two chloromethyl phenylcarbamate‐based chiral stationary phases, one containing an amylose‐type chiral selector (Lux Amylose 2, from Phenomenex) and the other a cellulose‐type one (Lux Cellulose‐4, from Phenomenex), were successfully used for the chiral resolution of three helical chromenes featuring a helicene‐like structure. The compound bearing a phenyl substituent on the helicene‐like structure was enantioresolved at 25°C with Lux Cellulose‐4 and a n‐hexane/1‐propanol 99:1 v/v eluent. With a n‐hexane/2‐propanol 99.8:0.2 v/v mobile phase, the same column (operated at 35°C) provided the separation of the four isomers of the compound having a hexyl residue on the helicene‐like motif and an additional asymmetric carbon. Lux Amylose‐2 was necessary for the enantioseparation of the compound having the sole hexyl residue on the helical scaffold. For the last compound a n‐hexane/2‐propanol 99.8:0.2 v/v eluent was used, and the column temperature was fixed at 5°C. The enantiomer elution order was appraised by using electronic circular dichroism and theoretical calculations. Notably, different thermodynamics of retention and enantioseparation were observed for molecules with pronounced structural similarity, that is, the enantiomer pairs of the compound containing the additional asymmetric carbon atom. Indeed, both entropically and enthalpically controlled adsorption and separation processes were observed.  相似文献   

5.
The separation and purification of hydroxytysol and oleuropein from Olea europaea L. (olive) using a macroporous resin with a novel solvent system was systematically investigated. Static adsorption experiments with BMKX–4 resin revealed that the experimental data of both hydroxytysol and oleuropein fitted best to the pseudo‐second‐order kinetic and Freundlich isotherm models. The thermodynamic parameters indicated spontaneous and exothermic adsorption processes. The novel solvent system, composed of n–hexane:ethyl acetate:methanol:water in a (v/v/v/v) ratio of 1:9:1:9, had two phases (upper and lower). The separation and purification parameters of hydroxytysol and oleuropein were optimized using dynamic adsorption/desorption on a column packed with BMKX–4 resin. The effects of flow rates and volumes of the upper and lower phases on the separation efficiency were systematically studied. Under optimal conditions, the fraction of hydroxytysol in the final product increased by 6.34‐fold from 0.46 to 2.96%, with a yield rate of 88.58% w/w, while that of oleuropein increased 4.17‐fold from 11.40 to 47.59%, with a 93.31% w/w yield rate. These results may be help in selecting a suitable eluent for improved separation of macroporous adsorption resins.  相似文献   

6.
Novel zirconium silicalite‐1 zeolite membrane was hydrothermally prepared on the mullite porous support at 150–185°C for 40–72 h by an "in situ" method using tetraethyl orthosilicate (TEOS), zirconium butoxide (ZBOT) and tetrapropylammonium hydroxide (TPAOH) as silica source, zirconium source and organic structure directing agent, respectively. X‐ray diffraction (XRD) patterns, fourier transformed infrared (FT‐IR) spectra, and inductively coupled plasma‐atomic emission spectrometry (ICP) of the accompanying zeolite powder confirmed that the zirconium was isomorphously incorporated into the zeolite framework. The surface chemical compositions of the obtained membrane were measured with an energy‐dispersive X‐ray spectral analyzer (EDS), and the membrane morphologies were observed by a scanning electron microscope (SEM). The results showed that the zeolite crystals growing on the support were zirconium silicalite‐1 zeolites, and the dense membrane layer was composed of the well inter‐growing zeolite crystals. The zirconium silicalite‐1 zeolite membrane, which was derived from the synthesis solution having a molar ratio of 1.00SiO2:0.01ZrO2:0.17TPAOH:120H2O, showed high ethanol permselectivity with a flux of 1.01 kg/(m2·h) accompanied with a separation factor of 73 for ethanol/water (5/95, w/w) system under a pervaporation condition at 60°C. Moreover, this membrane displayed pervaporation‐aided catalysis activity for iso‐propanol oxidation with hydrogen peroxide as oxidant, and the corresponding iso‐propanol conversion was 35%.  相似文献   

7.
Normal-phase and reversed-phase high-performance liquid chromatography methods for the separation of the active pharmaceutical ingredient escitalopram from its (R)-enantiomer impurity have been developed on the cellulose-based Chiralcel OJ-H chiral stationary phase. Both methods share two features: they use ethanol as a cosolvent and are able to give a complete enantioseparation without interference from other associated chiral impurities. With the green eluent mixture ethanol–water–diethylammine 70:30:0.1 (v/v/v), the resolution between escitalopram and (R)-enantiomer was 2.09 at 30°C. The limits of quantification for the (S) and (R) enantiomers were 4.5 and 3.8 μg mL−1, respectively.  相似文献   

8.
Several kinds of resins were investigated in the first step and D101 macroporous resin was selected for cleaning-up naringin (NAR), a major flavonoid glycoside from Fructus aurantii. In the subsequent column chromatography, 10% aqueous ethanol was first used to elute the column to remove the undesired constituents and 70% aqueous ethanol was used to elute the target. The content of NAR was 57.1% with 95.7% recovery in this process. In the second step, the obtained crude sample was directly isolated by high-speed counter-current chromatography (HSCCC) with a two-phase solvent system composed of ethyl acetate–n-butanol–water at a volume ratio of 2: 0.8: 3.2 (v/v/v), and 331 mg NAR with 98.3% purity was obtained from 600 mg crude extract in only one run. The recovery of the compound in this step was 95.0%. Thus, the total recovery of NAR was 90.9% after the two step purification. The established protocol for large-scale isolation and separation of NAR with high purity and recovery from F. aurantii was simple, efficient, and suitable for pharmace- utical and commercial use.  相似文献   

9.
This work reports two methods developed for the separation and determination of the enantiomers of the new alkaloid malacitanine (MLC) and the determination of the enantiomeric purity in mixtures. First, the isomers were separated using a Chirex 3020 (250 mm × 4.6 mm, 5 μm) chiral column with a mobile phase of cyclohexane–1,2‐dichloroethane–ethanol–trifluoroacetic acid (64:30:6:0.6, v/v/v/v) at a flow rate of 1 mL/min and fluorimetric detection. Obtained retention times were 12.4 and 15.9 min (+ and ?) with a resolution Rs of 1.13. Relative standard deviations (RSDs) were 2.5 and 2.4% at the 0.5‐μg level (four determinations). Second, a nonenantioselective procedure for the determination of enantiomeric purity of MLC using a Lichrospher ® Si‐60 (250 mm × 5 mm, 5 μm) normal phase with a mobile phase of 100% ethanol at a flow rate of 0.9 mL/min coupled to two detectors in series, fluorimetric and polarimetric. RSD of 3.3% was obtained. Calculated enantiomeric purity by chiral chromatography gave 48.6% (?)‐MLC in the near racemic product. Using polarimetric signal of the nonseparated enantiomers and comparing the slopes of the calibration curves (enantiomers) from the racemic product gave 47.8% (?)‐MLC content. A study of accuracy of (?)‐MLC gave recoveries from 98.3 to 100.7%.  相似文献   

10.
Liquid chromatographic separation of stereoisomers of darunavir on Chiralpak AD‐H, a column containing the stationary phase coated with amylose tris(3,5‐dimethylphenylcarbamate) as a chiral selector, was studied under normal‐phase conditions at different temperatures between 20 and 50°C. The effect of quality and quantity of different polar organic modifiers viz: methanol, ethanol, 1‐propanol, and 2‐propanol in the mobile phase as well as column temperature on retention, separation, and resolution was investigated and optimized. The optimum separation was accomplished using a mobile phase composed of n‐hexane/ethanol/diethyl amine (80:20:0.1 v/v/v) at 40°C. Apparent thermodynamic parameters ΔH0 and ΔS* were derived from the Van't Hoff plots (lnk′ versus 1/T) and used to explain the strength of interactions between the stereoisomers and amylose tris(3,5‐dimethylphenylcarbamate) coated chiral stationary phase.  相似文献   

11.
Abstract

A chiral separation of N(+)-and S(-)-benzyl-3-tetrahydrofuroate (I) and p-nitrobenzyl-3-tetrahydrofuroate (II) using a Chiralcel OB© (cellulose tribenzoate) column with a hexane/2-propanol (60:40 v/v) mobile phase is described. Enantiomeric purity of R(+)-I was evaluated using the same chromatographic conditions. I was also separated using a Chiralspher© (polyamides bonded to silica gel) column with an ethanol/distilled water (50:50 v/v) mobile phase.  相似文献   

12.
An investigation was carried out into the fast determination of five homologue imidazolium cations in ionic liquids by ion chromatography using a cation-exchange column and direct conductivity detection. Ethylenediamine, complex organic acid (citric acid, oxalic acid and tartaric acid) and organic modifiers (acetonitrile) were used as mobile phase. The influences of the eluent types, eluent concentration, eluent pH and column temperature on separation of the cations were discussed. Simultaneous separation and determination of the five homologue imidazolium cations in ionic liquids were achieved under an optimum condition. The optimized mobile phase was consisted of 0.25 mmol L?1 ethylenediamine + 0.5 mmol L?1 citric acid + 3% acetonitrile (v/v) (pH 4.1), set at a flow rate of 1.0 mL min?1. The column temperature was 40 °C and detection limits were obtained in the range of 1.1–45.6 mg L?1. The relative standard deviations of the chromatographic peak areas for the cations were <3.0% (n = 5). This method was successfully applied to separate imidazolium cations in ionic liquids produced by organic synthesis. The recoveries of spiked components were 92.5–101.9%.  相似文献   

13.
Stilbenoids are the main components of leaves and stems of Pholidota chinensis. In the present investigation, high‐speed counter‐current chromatography was used for the separation and purification of two classes of stilbenoids, namely, bibenzyls and 9,10‐dihydrophenanthrenes, on a preparative scale from whole plants of P. chinensis with different solvent systems after silica gel column chromatography fractionation. n‐Hexane/ethyl acetate/methanol/water (1.2:1:1:0.8, v/v/v/v) was selected as the optimum solvent system to purify 1‐(3,4,5‐trimethoxyphenyl)‐1′,2′‐ethanediol ( 1 ), coelonin ( 2 ), 3,4′‐dihydroxy‐5,5′‐dimethoxybibenzyl ( 3 ), and 2,?7‐?dihydroxy‐?3,?4,?6‐?trimethoxy‐?9,?10‐?dihydrophenanthrene ( 4 ). While 2,7‐dihydroxy‐3,4,6‐trimethoxy‐?9,?10‐?dihydrophenanthrene ( 5 ), batatasin III ( 6 ), orchinol ( 7 ), and 3′‐O‐methylbatatasin III ( 8 ) were purified by n‐hexane/ethyl acetate/methanol/water (1.6:0.8:1.2:0.4, v/v/v/v). After the high‐speed counter‐current chromatography isolation procedure, the purity of all compounds was over 94% assayed by ultra high performance liquid chromatography. The chemical structure identification of all compounds was carried out by mass spectrometry and 1H and 13C NMR spectroscopy. To the best of our knowledge, the current investigation is the first study for the separation and purification of bibenzyls and 9,10‐dihydrophenanthrenes by high‐speed counter‐current chromatography from natural resources.  相似文献   

14.
In this paper, macroporous resin column chromatography and counter‐current chromatography (CCC) were applied for large‐scale preparative separation of three flavonoids from the flower of Daphne genkwa, a famous Chinese medicinal herb. Nine kinds of resins were investigated by adsorption and desorption tests and D101 macroporous resin was selected for the first cleaning‐up, in which 40% aqueous ethanol was used to remove the undesired constituents and 90% aqueous ethanol was used to elute the targets. The crude extract after the first step was directly subjected to the preparative CCC purification using the solvent system composed of n‐hexane–ethyl acetate–methanol–water (4:5:4:5, v/v). The compounds apigemin (823 mg), 3‐hydroxyl‐genkwanin (842 mg) and genkwanin (998 mg) with the purities of 98.79, 97.71 and 93.53%, respectively, determined by HPLC were produced from 3‐g crude extract only in one CCC run. Their chemical structures were identified by MS, UV and the standards.  相似文献   

15.
A simple and reproducible UPLC‐MS/MS method for the determination of itraconazole (ITZ) and its photodegradation products formed during exposure to UV‐A radiation was developed. Chromatographic separations were carried out using an Acquity UPLC BEH C18 column (2.1 × 100 mm, 1.7 μm particle size). The column was maintained at 40°C, and eluted under gradient conditions from 100% to 50% of eluent A over 13 min, at a flow rate of 0.3 mL min?1. Eluent A was 0.1% (v/v) formic acid in water; eluent B was 0.1% (v/v) formic acid in acetonitrile. The linear regression analysis for the calibration curve showed a good linear correlation over the concentration range 0.0066–0.15 mg mL?1 with determination coefficient > 0.99. The activities of some photocatalysts during degradation process of ITZ were compared. It was found that indirect photodegradation of ITZ was more effective than direct photolysis. Under our experimental conditions the photodegradation rate constant depended on the applied catalysts with catalytic activity decreasing in the following pattern: FeCl3 > TiO2/FeCl3 > TiO2. The kinetic analysis of the photodegradation data revealed that the degradation of the ITZ follows first‐order kinetics. The photodegradation products of ITZ were identified, and their fragmentation pathways, derived from MS/MS data, were proposed. Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   

16.
A simple liquid chromatographic method was developed for the separation and simultaneous determination of cobalt and nickel as chelates with 1-(2-pyridylazo)-2-naphthol (PAN). The method, using a switching column technique for the on-line purification and separation, enables to reach the sub-microgram per litre concentration level excluding off-line sample treatment with the exception of the derivatization reaction. Two small-sized columns packed with CN- and C4-bonded stationary phases were selected and used considering their complementary behaviour with respect to chelated Co and Ni ions. The analysis was performed within 10 min using an optimised eluent (water–acetonitrile–methanol–tetrahydrofuran, 40:45:10:5, v/v/v/v) containing Tween 40 (10?3 M) and acetate buffer (5 × 10?3 M, pH 4.8). Detection was performed by UV-vis spectrophotometry (λ = 565 nm) permitting to reach quantification limits of 0.9 and 0.5 μg L?1 for Co and Ni, respectively.  相似文献   

17.
In this article, a simple and efficient protocol for rapid preparation and separation of neohesperidin from the albedo of Citrus reticulata cv. Suavissima was established by the combination of macroporous resin column chromatography and high-speed counter-current chromatography (HSCCC). Six types of resin were investigated by adsorption and desorption tests, and D101 macroporous resin was selected for the first cleaning-up procedure, in which 55% aqueous ethanol was used to elute neohesperidin. After treatment with D101 resin, the neohesperidin purity increased 11.83-fold from 4.92% in the crude extract to 58.22% in the resin-refined sample, with a recovery of 68.97%. The resin-refined sample was directly subjected to HSCCC purification with a two-phase solvent system composed of ethyl acetate-n-butanol-water (4:1:5, v/v), and 23.6 mg neohesperidin with 97.47% purity was obtained from 60 mg sample in only one run. The recovery of neohesperidin in HSCCC separation procedure was 65.85%. The chemical structure of the purified neohesperidin was identified by both HPLC and LC-MS. The established purification process will be helpful for further characterization and utilization of Citrus neohesperidin.  相似文献   

18.
 L-Lysine was produced by a microbial process utilizing a Corynebacterium glutamicum (ATCC 21799) strain. L-Lysine was purified from the cultivated medium by fixed-bed and simulated moving bed (SMB) chromatography. The separation conditions including pH, eluent concentration and Lys+ and Lys2+ adsorption isotherms were studied in batch adsorption. The column capacity, eluent flow rate and eluent concentration have been studied in fixed-bed chromatography. Maximum purification rate of lysine was obtained as 0.066 g/(g·h) (per gram resin and per hour) at an eluent flow rate of 10 mL/min in fixed-bed chromatography. The results obtained from SMB were 0.11 g/(g·h) for L-lysine purification rate and 96% for L-lysine recovery.  相似文献   

19.
Tzanis  Lydie  Simon  Patrice  Walcarius  Alain 《Chromatographia》2008,67(11):857-861

A simple liquid chromatographic method was developed for the separation and simultaneous determination of cobalt and nickel as chelates with 1-(2-pyridylazo)-2-naphthol (PAN). The method, using a switching column technique for the on-line purification and separation, enables to reach the sub-microgram per litre concentration level excluding off-line sample treatment with the exception of the derivatization reaction. Two small-sized columns packed with CN- and C4-bonded stationary phases were selected and used considering their complementary behaviour with respect to chelated Co and Ni ions. The analysis was performed within 10 min using an optimised eluent (water–acetonitrile–methanol–tetrahydrofuran, 40:45:10:5, v/v/v/v) containing Tween 40 (10−3 M) and acetate buffer (5 × 10−3 M, pH 4.8). Detection was performed by UV-vis spectrophotometry (λ = 565 nm) permitting to reach quantification limits of 0.9 and 0.5 μg L−1 for Co and Ni, respectively.

  相似文献   

20.
A simple and rapid reversed‐phase high‐performance liquid chromatographic method for the separation and determination of 4‐amino‐azobenzene‐4′,5‐disulfonic acid (AABDS) and its process‐related impurities was developed. The separation was achieved on a μ‐Bondapak C18 column using 0.15 M ammonium sulfate‐acetonitrile (55:45) (v/v) as eluent. A UV‐visible spectrophotometric detector fixed at 386 nm was used both for detection and quantitation. The method was used not only for quality assurance but also for process development and wastewater management of AABDS.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号