首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
Monodisperse silica particles with average diameters of 1.9–2.9 μm were synthesized by a modified Stöber method, in which tetraethyl orthosilicate was continuously supplied to the reaction mixture containing KCl electrolyte, water, ethanol, and ammonia. The obtained silica particles were modified by self‐assembly with positively charged photosensitive diazoresin on the surface. After treatment with ultraviolet light, the ionic bonding between silica and diazoresin was converted into covalent bonding through a unique photochemistry reaction of diazoresin. Depending on the chemical structure of diazoresin and mobile phase composition, the diazoresin‐modified silica stationary phase showed different separation mechanisms, including reversed phase and hydrophilic interactions. Therefore, a variety of baseline separation of benzene analogues and organic acids was achieved by using the diazoresin‐modified silica particles as packing materials in ultra high performance liquid chromatography. According to the π–π interactional difference between carbon rings of fullerenes and benzene rings of diazoresin, C60 and C70 were also well separated by ultra‐high performance liquid chromatography. Because it has a small size, the ∼2.5 μm monodisperse diazoresin‐modified silica stationary phase shows ultra‐high efficiency compared with the commercial C18‐silica high‐performance liquid chromatography stationary phase with average diameters of ∼5 μm.  相似文献   

2.
The parameters that affect the shape of the band profiles of acido‐basic compounds under moderately overloaded conditions (sample size less than 500 nmol for a conventional column) in RPLC are discussed. Only analytes that have a single pKa are considered. In the buffer mobile phase used for their elution, their dissociation may, under certain conditions, cause a significant pH perturbation during the passage of the band. Two consecutive injections (3.3 and 10 μL) of each one of three sample solutions (0.5, 5, and 50 mM) of ten compounds were injected on five C18‐bonded packing materials, including the 5 μm Xterra‐C18 (121 Å), 5 μm Gemini‐C18 (110 Å), 5 μm Luna‐C18(2) (93 Å), 3.5 μm Extend‐C18 (80 Å), and 2.7 μm Halo‐C18 (90 Å). The mobile phase was an aqueous solution of methanol buffered at a constant WWpH of 6, with a phosphate buffer. The total concentration of the phosphate groups was constant at 50 mM. The methanol concentration was adjusted to keep all the retention factors between 1 and 10. The compounds injected were phenol, caffeine, 3‐phenyl 1‐propanol, 2‐phenyl butyric acid, amphetamine, aniline, benzylamine, p‐toluidine, procainamidium chloride, and propranololium chloride. Depending on the relative values of the analyte pKa and the buffer solution pH, these analytes elute as the neutral, the cationic, or the anionic species. The influence of structural parameters such as the charge, the size, and the hydrophobicity of the analytes on the shape of its overloaded band profile is discussed. Simple but general rules predict these shapes. An original adsorption model is proposed that accounts for the unusual peak shapes observed when the analyte is partially dissociated in the buffer solution during its elution.  相似文献   

3.
This work reports the use of two‐dimensional (2D) liquid chromatography system coupled with a tandem mass spectrometry for the quantification of ampicillin in bovine milk. A restrict access media column (RAM‐BSA C8, 50 × 2.1 mm, Luna, 10 μm, 100 Å) was used in the first dimension in order to exclude macromolecules, while an ACQUITY UPLC BEH C18 (50 × 2.1 mm, 1.7 μm) column was used in the second dimension. Three different channels of selected reaction monitoring (SRM) were used: 350 > 106 m/z, 350 > 160 m/z, and 350 > 192 m/z. The first transition was used for the quantification (higher intensity), and latter two for confirmation. The developed method is simple and requires a total analysis time of only 14 min/sample. The sample treatment involved only a centrifugation step for 20 min. The validated method has been successfully applied to monitor AMP residues in raw milk samples. To our knowledge, this is the first study to report the use of ultrahigh‐performance liquid chromatography (UHPLC) in 2D configuration.  相似文献   

4.
New generation columns, i.e. packed with superficially porous silica particles are available as trade names with following manufacturers: Halo, Ascentis Express, Proshell 120, Kinetex, Accucore, Sunshell, and Nucleoshell. These provide ultra‐fast HPLC separations for a variety of compounds with moderate sample loading capacity and low back pressure. Chemistries of these columns are C8, C18, RP‐Amide, hydrophilic interaction liquid chromatography, penta fluorophenyl (PFP), F5, and RP‐aqua. Normally, the silica gel particles are of 2.7 and 1.7 μm as total and inner solid core diameters, respectively, with 0.5‐μm‐thick of outer porous layer having 90 Å pore sizes and 150 m2/g surface area. This article describes these new generation columns with special emphasis on their textures and chemistries, separations, optimization, and comparison (inter and intra stationary phases). Besides, future perspectives have also been discussed.  相似文献   

5.
In this work, the chromatographic performance of superficially porous particles (Halo core–shell C18 column, 50 mm × 2.1 mm, 2.7 μm) was compared with that of sub‐2 μm fully porous particles (Acquity BEH C18, 50 mm × 2.1 mm, 1.7 μm). Four parabens, methylparaben, ethylparaben, propylparaben, and butylparaben, were used as representative compounds for calculating the plate heights in a wide flow rate range and analyzed on the basis of the Van Deemter and Knox equations. Theoretical Poppe plots were constructed for each column to compare their kinetic performance. Both phases gave similar minimum plate heights when using nonreduced coordinates. Meanwhile, the flat C‐term of the core–shell column provided the possibilities for applying high flow rates without significant loss in efficiency. The low backpressure of core–shell particles allowed this kind of column, especially compatible with conventional high‐performance liquid chromatography systems. Based on these factors, a simple high‐performance liquid chromatography method was established and validated for the determination of parabens in various seafood sauces using the Halo core–shell C18 column for separation.  相似文献   

6.
Herein, we report a newly developed C60 fullerene‐bonded silica monolith in a capillary with unique retention behavior due to the structure of C60 fullerene. N‐Hydroxysuccinimide (NHS)‐conjugated C60 fullerene was successfully synthesized by a thermal coupling agent, perfluorophenyl azide (PFPA), and assigned by spectroscopic analyses. Then, NHS‐PFPA‐C60 fullerene was attached onto the surface of a silica monolith in a capillary. The capillary provided specific separation ability for polycyclic aromatic hydrocarbons in liquid chromatography by an effective π–π interaction. Furthermore, corannulene, which has a hemispherical structure, was selectively retained in the capillary based on the specific structural recognition due to the spherical C60 fullerene. This is the first report revealing the spherical recognition ability by C60 fullerene in liquid chromatographic separation.  相似文献   

7.
A silica‐particle‐supported zwitterionic polymeric monolithic column, shortened as supported column (S‐column), was prepared by the in situ polymerization of methacrylic acid, ethylene dimethacrylate, and 2‐(dimethylamino)ethyl methacrylate in the presence of a ternary porogenic solvent containing water, methanol, and cyclohexanol in a 250 μm id fused‐silica capillary prepacked with 5 μm bare silica particles. In the S‐column, a thin layer of the polymers was formed around the silica particles in the form of nanoglobules, leaving the interstitial spaces between the particles free for liquid flow. The effects of the preparation conditions on the morphology of the monolith were investigated by scanning electron microscopy and backpressure measurements. The selected volumetric ratio of porogens, monomer concentration, polymerization time, and temperature are 1:1:8 (water/methanol/cyclohexanol), 25% v/v, 5 h, and 60°C, respectively. The S‐column was evaluated by comparison with its conventional organic counterpart in terms of morphology, mechanical stability, permeability, swelling–shrinking behavior, capacity, and efficiency. The results demonstrate that the S‐column is superior to its counterpart in all the terms with the exception of permeability. The above merits and zwitterionic property of the S‐column were further confirmed by separate separations of four inorganic anions and three organic cations.  相似文献   

8.
We established a qualitative method to analyze the main chemical compositions of the root of Aster tataricus. Most of the peaks were separated on a C18 column packed with 5.0 μm particles, and 28 compounds were identified, including 11 chlorogenic acids, ten astins/asterinins, and seven astersaponins, four of which were reported for the first time from A. tataricus. Furthermore, we developed a reliable method for the simultaneous quantification of 3‐caffeoylquinic acid, 3,4‐dicaffeoylquinic acid, 3,5‐dicaffeoylquinic acid, astin A, astin B, astin C, astersaponin A, and astersaponin C, and the qualified separations were achieved only on a C18 column packed with 2.7 μm particles. The method was used to measure the concentrations of eight components in samples from two major producing areas in China, and the average contents in samples from Bozhou (Anhui) were higher than those in samples from Anguo (Hebei).  相似文献   

9.
A simple, robust, and rapid LC‐MS/MS method was developed for the quantitation of U0126 and validated in rat plasma. Plasma samples (20 μL) were deproteinized using 200 μL ACN containing 30 ng/mL of chlorpropamide, internal standard. Chromatographic separation performed on an Agilent Poroshell 120 EC‐C18 column (4.6 × 50 mm, 2.7 μm particle size) with an isocratic mobile phase consisting of a 70:30 v/v mixture of ACN and 0.1% aqueous formic acid. Each sample was run at 0.6 mL/min for a total run time of 2 min per sample. Detection and quantification were performed using a mass spectrometer in selected reaction‐monitoring mode with positive ESI at m/z 381 → 123.9 for U0126 and m/z 277 → 175 for the internal standard. The standard curve was linear over a concentration range of 20–5000 ng/mL with correlation coefficients greater than 0.9965. Precision, both intra‐ and interday, was less than 10.1% with an accuracy of 90.7–99.4%. No matrix effects were observed. U0126 in rat plasma degraded approximately 41.3% after 3‐h storage at room temperature. To prevent degradation, sample handling should be on an ice bath and all solutions kept at 4°C. This method was successfully applied to a pharmacokinetic study of U0126 at various doses in rats.  相似文献   

10.
A simple, rapid and economical method was developed and validated for the analysis and quantification of 1‐(propan‐2‐ylamino)‐4‐propoxy‐9H ‐thioxanthen‐9‐one (TX5), a P‐glycoprotein inducer/activator, in biological samples, using reverse‐phase high‐performance liquid chromatography (HPLC). A C18 column and a mobile phase composed of methanol–water (90/10, v /v) with 1% (v/v) triethylamine, at a flow rate of 1 mL/min, were used for chromatographic separation. TX5 standards (0.5–150 μm ) were prepared in human serum. Methanol was used for TX5 extraction and serum protein precipitation. After filtration, samples were injected into the HPLC apparatus and TX5 was quantified by a conventional UV detector at 255 nm. The TX5 retention time was 13 min in this isocratic system. The method was validated according to ICH guidelines for specificity/selectivity, linearity, accuracy, precision, limits of detection and quantification (LOD and LOQ) and recovery. The method was proved to be selective, as there were no interferences of endogenous compounds with the same retention time of TX5. Also, the developed method was linear (r 2 ≥ 0.99) for TX5 concentrations between 0.5 and 150 μm and the LOD and LOQ were 0.08 and 0.23 μm , respectively. The results indicated that the reported method could meet the requirements for TX5 analysis in the trace amounts expected to be present in biological samples.  相似文献   

11.
The overall kinetic performance of three production columns (2.1 mm × 100 mm format) packed with 1.6 μm superficially porous CORTECS‐C18+ particles was assessed on a low‐dispersive I‐class ACQUITY instrument. The values of their minimum intrinsic reduced plate heights (hmin = 1.42, 1.57, and 1.75) were measured at room temperature (295 K) for a small molecule (naphthalene) with an acetonitrile/water eluent mixture (75:25, v/v). These narrow‐bore columns provide an average intrinsic efficiency of 395 000 plates per meter. The gradient separation of 14 small molecules shows that these columns have a peak capacity about 25% larger than similar ones packed with fully porous BEH‐C18 particles (1.7 μm) or shorter (50 mm) columns packed with smaller core–shell particles (1.3 μm) operated under very high pressure (>1000 bar) for steep gradient elution (analysis time 80 s). In contrast, because their permeabilities are lower than those of columns packed with larger core–shell particles, their peak capacities are 25% smaller than those of narrow‐bore columns packed with standard 2.7 μm core–shell particles.  相似文献   

12.
A new platform technology for the preparation of stable chiral stationary phases was successfully optimized. The chiral selector tert‐butylcarbamoylquinine was firstly covalently connected to the polymer poly(3‐mercaptopropyl)methylsiloxane by thiol‐ene click reaction. Secondly, the quinine carbamate functionalized polysiloxane conjugate was coated onto the surface of vinyl modified silica particles and cross‐linked via thiol‐ene click reaction. The amount of polysiloxane, chiral selector, radical initiator, reaction solvent (chloroform and methanol), reaction time, and pore size of the supporting silica particles were varied and systematically optimized in terms of achievable plate numbers while maintaining simultaneously enantioselectivity. The optimization was based on elemental analysis data, chromatographic results, and H/u‐curves (Van Deemter) of the resultant chiral stationary phases. The results suggest that better chromatographic efficiency (higher plate numbers) at equal enantioselectivity can be achieved with methanol (a poor solvent for the polysiloxane that is dispersed rather than dissolved) and a lower film thickness of quinine carbamate functionalized polysiloxane. In this study, chiral stationary phases based on 100 Å silica slightly outperformed 200 Å silica particles (each 5 μm). The optimized two step material exhibited significantly reduced mass transfer resistance compared to the one step material and equal performance as a brush‐type chiral stationary phase.  相似文献   

13.
A range of porous carbon‐based monolithic (PCM) rods with flow‐through pore sizes of 1, 2, 5 and 10 μm, were produced using a silica particle template method. The rods were characterised using SEM and energy‐dispersive X‐ray spectroscopy, BET surface area and porous structure analysis, dilatometry and thermal gravimetry. SEM evaluation of the carbon monolithic structures revealed an interconnected rigid bimodal porous structure and energy‐dispersive X‐ray spectroscopy analysis verified the quantitative removal of the embedded silica beads. The specific surface areas of the 1, 2, 5 and 10 μm rods were 178, 154, 84 and 125 m2/g after pyrolysis and silica removal, respectively. Shrinkage of the monolithic rods during pyrolysis is proportional to the particle size of the silica used and ranged from 9 to 12%. Mercury porosimetry showed a narrow distribution of pore sizes, with an average of ~700 nm for the 1 μm carbon monolith. The suitability of bare and surface oxidised PCM rods for the use as a stationary phase for reversed and normal phase LC was explored. The additional modification of PCM rods with gold micro‐particles followed by 6‐mercaptohexanoic acid was performed and ion‐exchange properties were evaluated.  相似文献   

14.
We report on the optimization of nano‐LC gradient separations of proteomic samples that vary in complexity. The gradient performance limits were visualized by kinetic plots depicting the gradient time needed to achieve a certain peak capacity, while using the maximum system pressure of 80 MPa. The selection of the optimal particle size/column length combination and corresponding gradient steepness was based on scouting the performance of 75 μm id capillary columns packed with 2, 3, and 5 μm fully porous silica C18 particles. At optimal gradient conditions, peak capacities up to 500 can be obtained within a 120 min gradient using 2 μm particle‐packed capillary columns. Separations of proteomic samples including a cytochrome c tryptic digest, a bovine serum albumin tryptic digest, a six protein mix digest, and an Escherichia coli digest are demonstrated while operating at the kinetic‐performance limit, i.e. using 2‐μm packed columns, adjusting the column length and scaling the gradient steepness according to sample complexity. Finally, good run‐to‐run retention time stability (RSD values below 0.18%) was demonstrated applying ultra‐high pressure conditions.  相似文献   

15.
m‐Cresol‐imprinted silica nanoparticles coated with N‐propylsilylmorpholine‐4‐carboxamide have been developed that contain specific pockets for the selective uptake of m‐cresol. Silica nanoparticles were synthesized by a sol–gel process followed by functionalization of their surface with N‐propylsilylmorpholine‐4‐carboxamide. The formation of m‐cresol‐imprinted silica nanoparticles was confirmed by UV‐Vis spectrophotometry, infrared spectroscopy, thermogravimetric analysis, scanning electron microscopy and transmission electron microscopy. Electron microscopic studies revealed the formation of monodispersed imprinted silica nanoparticles with spherical shape and an average size of 83 nm. The developed nanoparticles were filled in a syringe and used for the extraction of m‐cresol from aqueous samples followed by quantification using high‐performance liquid chromatography with diode array detection. Various adsorption experiments showed that developed m‐cresol‐imprinted silica nanoparticles exhibited a high adsorption capacity and selectivity and offered a fast kinetics for rebinding m‐cresol. The chromatographic quantification was achieved using mobile phase consisting of acetonitrile/water (70:30 v/v) at an isocratic flow rate of 1.0 mL/min using a reversed‐phase C18 column and detection at λmax = 275 nm. The limits of detection and quantification were 1.86 and 22.32 ng/mL, respectively, for the developed method. The percent recoveries ranged from 96.66–103.33% in the spiked samples. This combination of this nanotechnique with molecular imprinting was proved as a reliable, sensitive and selective method for determining the target from synthetic and real samples.  相似文献   

16.
Three mixed‐mode high‐performance liquid chromatography columns packed with superficially porous carbon/nanodiamond/amine‐polymer particles were used to separate mixtures of cannabinoids. Columns evaluated included: (i) reversed phase (C18), weak anion exchange, 4.6 × 33 mm, 3.6 μm, and 4.6 × 100 mm, 3.6 μm, (ii) reversed phase, strong anion exchange (quaternary amine), 4.6×33 mm, 3.6 μm, and (iii) hydrophilic interaction liquid chromatography, 4.6 × 150 mm, 3.6 μm. Different selectivities were achieved under various mobile phase and stationary phase conditions. Efficiencies and peak capacities were as high as 54 000 N/m and 56, respectively. The reversed phase mixed‐mode column (C18) retained tetrahydrocannabinolic acid strongly under acidic conditions and weakly under basic conditions. Tetrahydrocannabinolic acid was retained strongly on the reversed phase, strong anion exchange mixed‐mode column under basic polar organic mobile phase conditions. The hydrophilic interaction liquid chromatography column retained polar cannabinoids better than the (more) neutral ones under basic conditions. A longer reversed phase (C18) mixed‐mode column (4.6 × 100 mm) showed better resolution for analytes (and a contaminant) than a shorter column. Fast separations were achieved in less than 5 min and sometimes 2 min. A real world sample (bubble hash extract) was also analyzed by gradient elution.  相似文献   

17.
In the last decade, core–shell particles have gained more and more attention in fast liquid chromatography separations due to their comparable performance with fully porous sub‐2 μm particles and their significantly lower back pressure. Core–shell particles are made of a solid core surrounded by a shell of classic fully porous material. To embrace the developed core–shell column market and use these columns in pharmaceutical analytical applications, 17 core–shell C18 columns purchased from various vendors with various dimensions (50 mm × 2.1 mm to 100 mm × 3 mm) and particle sizes (1.6–2.7 μm) were characterized using Tanaka test protocols. Furthermore, four selected active pharmaceutical ingredients were chosen as test probes to investigate the batch to batch reproducibility for core–shell columns of particle size 2.6–2.7 μm, with dimension of 100 × 3 mm and columns of particle size 1.6 μm, with dimension 100 × 2.1 mm under isocratic elution. Columns of particle size 2.6–2.7 μm were also tested under gradient elution conditions. To confirm the claimed comparable efficiency of 2.6 μm core–shell particles as sub‐2 μm fully porous particles, column performances of the selected core–shell columns were compared with BEH C18, 1.7 μm, a fully porous column material as well.  相似文献   

18.
A comparison between C18 silica and multi‐walled carbon nanotubes (MWCNTs) in the extraction of Chlorpyrifos and Phosalone in environmental water samples was carried out using HPLC. Parameters affecting the extraction were type and volume of elution solvent, pH and flow rate of sample through the adsorbent. The optimum conditions obtained by C18 cartridge for adsorption of these pesticides were 4 mL dichloromethane as elution solvent, sample pH of 5, flow rate of 1 mL/min, and those for MWCNT cartridge were 3 mL dichloromethane, pH of 5 and flow rate of 10 mL/min, respectively. Optimized mobile phase for separation and determination of these compounds by HPLC was methanol/water (80:20 v/v) with pH=5 (adjusted with phosphate buffer). Under optimal chromatographic and SPE conditions, LOD, linear range and precision (RSD n=8) were 3.03×10?3, 0.01–5.00 μg/mL and 2.7% for Chlorpyrifos and 4.03×10?4, 0.01–5.00 μg/mL and 2.3% for Phosalone, in C18 cartridge, respectively. These values for MWCNT were 4.02×10?6, 0.001–0.500 μg/mL and 1.8% for Chlorpyrifos and 1.02×10?6, 0.001–0.500 μg/mL and 1.5% for Phosalone, respectively.  相似文献   

19.
A novel sulfoalkylbetaine‐based zwitterionic organic‐silica hybrid monolith was synthesized by using 3‐dimethyl‐(3‐(N‐methacrylamido) propyl) ammonium propane sulfonate (DMMPPS, neutral sulfoalkyl‐betaine monomer). The added amount of zwitterionic monomer was significantly increased when DMMPPS was used instead of the conventionally used acidic sulfoalkyl‐betaine monomer, that is, the N,N‐dimethyl‐N‐ methacryloxyethyl‐N‐(3‐sulfopropyl) ammonium betaine, and this led to a significantly improved hydrophilicity of the monolith. The DMMPPS‐based organic‐silica hybrid monolith exhibited good mechanical stability and excellent separation performance. About ~20 μm plate height (corresponding to column efficiency of ~50 000 plates/m) was obtained for nucleoside at the linear velocity of 1 mm/s. The proposed monolithic column was successfully applied to separate purines/pyrimidines, nucleotides, and tryptic digest of bovine hemoglobin in a nano‐HILIC mode, and the results demonstrated that such monolith has the potential for separation of a variety of hydrophilic substances.  相似文献   

20.
A variety of fluoroalkyl end‐capped N‐(1,1‐dimethyl‐3‐oxobutyl)acrylamide oligomer [RF‐(DOBAA)n‐ RF]/silica nanocomposites, in which the oligomer contents are 18–96%, were prepared by reactions of the corresponding fluorinated oligomer with tetraethoxysilane and silica nanoparticles under alkaline conditions. Each fluorinated oligomer/silica composite thus obtained is nanometer size‐controlled very fine particles (22–68 nm) possessing a good dispersibility and stability in a variety of solvents including water. Interestingly, the weight loss of RF‐(DOBAA)n‐RF/silica nanocomposites, in which the oligomer contents are 18–72%, were not observed at all even at 800°C, as well as the original silica nanoparticles, although the corresponding sub‐micrometer size‐controlled RF‐ (DOBAA)n‐RF/silica composites (particle size: 359 nm) decomposed completely at 800°C to afford the weight loss in proportion to the content of RF‐(DOBAA)n‐RF oligomer in composites. On the other hand, a slight weight loss of RF‐(DOBAA)n‐RF/silica nanocomposites, in which the oligomer contents are 75–94%, was observed at 800°C compared to that of the original silica nanoparticles. Copyright © 2008 John Wiley & Sons, Ltd.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号