首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
The initialization of concentration vector for iterative target transformation factor analysis (ITTFA) and identification of pure or key variables are the important issue in MCR. In this study, dissimilarity analysis and evolving factor analysis (EFA) are combined to find the selective or key variables and subsequently obtain initial estimates of the concentration vectors for resolution of gas chromatography/mass spectrometry (GC/MS) data by ITTFA. For systems containing components with highly similar mass spectra, a new constraint setting the elements out of elution window to 0 is used to improve convergence rate and accuracy of results. Tested by standard mixture of two wax esters and real GC/MS data of gasoline 97#, dissimilarity based ITTFA could obtain accurate results (average Dot product of concentration vectors, average deviation of peak area ratio and average similarity of mass spectra are 0.9929, 0.0228 and 981.0, respectively).  相似文献   

2.
A new method was developed for the trace determination of phthalic acid esters in plasma using dispersive liquid–liquid microextraction and gas chromatography with mass spectrometry analysis. Plasma proteins were efficiently precipitated by trichloroacetic acid and then a mixture of chlorobenzene (as extraction solvent) and acetonitrile (as dispersive solvent) rapidly injected to clear supernatant using a syringe. After centrifuging, chlorobenzene sedimented at the bottom of the test tube. 1 μL of this sedimented phase was injected into the gas chromatograph for phthalic acid esters analysis. Different factors affecting the extraction performance, such as the type of extraction and dispersive solvent, their volume, extraction time, and the effects of salt addition were investigated and optimized. Under the optimum conditions, the enrichment factors and extraction recoveries were satisfactory and ranged between 820–1020 and 91–97%, respectively. The linear range was wide (50–1000 ng/mL) and limit of detection was very low (1.5–2.5 ng/mL for all analytes). The relative standard deviations for analysis of 1 μg/mL of the analytes were between 3.2–6.1%. Salt addition showed no significant effect on extraction recovery. Finally, the proposed method was successfully utilized for the extraction and determination of the phthalic acid esters in human plasma samples and satisfactory results were obtained.  相似文献   

3.
N W Rawle  R G Willis  J D Baty 《The Analyst》1990,115(5):521-523
Triacylglycerols from rat adipose tissue were chromatographed by high-performance liquid chromatography (HPLC), with a gradient of propan-2-ol in acetonitrile as the mobile phase. Fractions of the material eluting from the column were collected and analysed by automated gas - liquid chromatography of the fatty acid methyl esters obtained after transmethylation. Triacylglycerols were identified by using a combination of their fatty acid content and elution time from the HPLC column. Fractions corresponding to whole peaks or groups of peaks were also collected and re-chromatographed on a liquid chromatography - mass spectrometry system equipped with a belt interface. For most triacylglycerols, good agreement was obtained between the two methods, although mass spectrometric identification of the early eluting peaks was complicated by poor resolution of the triacylglycerols on the HPLC system.  相似文献   

4.
Time-of-flight (TOF) instruments have recently gained popularity in quantitative analyses. Normally, TOF mass spectrometers are used for accurate mass measurements for empirical formula verification. However, over the past decade, they have been used quantitatively as well. Because of the fast separations and narrow peaks that result from gas chromatography separations, scanning mass spectrometers are not ideal detectors. TOF mass spectrometers, however, have the ability to collect spectra at a faster rate. Two-dimensional gas chromatography has also been introduced to further resolve peaks from complex matrices. Two-dimensional gas chromatography results in a faster separation as well as narrower peaks. This paper reviews the methods currently in the literature for the quantitation of compounds using one- and two-dimensional gas chromatography and TOF mass spectrometry detection.  相似文献   

5.
建立了固相萃取结合气相色谱串联质谱联用仪检测土壤中15种邻苯二甲酸酯残留的方法。样品采用丙酮和石油醚超声提取,取上清液浓缩,上弗罗里硅土固相萃取柱净化,收集洗脱液,定容,以气相色谱串联质谱法分析。该方法在20~2 000 ng/g范围内线性关系良好(r~20.999 0),检出限(S/N=3)为0.12~0.61 ng/g。20,50,200 ng/g 3个添加浓度的15种邻苯二甲酸酯的加标回收率在78.9%~101.8%之间,测定结果的相对标准偏差为0.19%~8.34%(n=5)。该方法准确、灵敏,符合痕量分析的要求,适用于土壤中邻苯二甲酸酯类残留的分析。  相似文献   

6.
It is shown that both electrospray and fast atom bombardment mass spectrometry provide excellent negative-ion mass spectra of the anionic esters of boric, boronic and borinic acids. For electrospray, contact of the esters with water causes some hydrolysis but, in most cases, spectra of the intact molecular anions are readily obtained. For fast atom bombardment, solvents that chelate with the boron esters must be avoided, Tetraethylene glycol diethyl ether, pentaethylene glycol dimethyl ether or hexaethylene glycol dimethyl ether are suitable solvents. Negative-ion electrospray mass spectra showed few, if any, fragment ions, whereas fast atom bombardment generally produced abundant M? ions and several fragment ions of low abundance. It is shown that a simple reaction with dibenzene-borinic acid converts diols such as monoglycerides and monoalkyl glyceryl ethers into anionic borinate esters as a pre-ionization procedure for analysis by electrospray or fast atom bombardment mass spectrometry.  相似文献   

7.
Crude combwax of six various honey bee species have been analyzed by high-temperature gas chromatography (HTGC)-chemical ionization mass spectrometry after a two-step silylation procedure. An optimized chromatographic procedure, described previously, enables the separation of high-molecular mass lipid compounds resulting in a characteristic fingerprint of the combwaxes of different honeybee species. The coupling of HTGC to mass spectrometry requires appropriate instrumentation in order to achieve sufficient sensitivity at high elution temperatures and avoid loss of chromatographic resolution. Chemical ionization was carried out using methane as reagent gas in order to determine the molecular mass of the individual compounds by means of abundant quasi molecular ions. To confirm the presence of unsaturated wax esters, ammonia was used as reagent gas. More than 80 lipid constituents were separated and characterized by their mass spectra. Representative chemical ionization mass spectra of individual compounds are presented. Both, HTGC-flame ionization detection data and the results of the HTGC-mass spectrometric investigations enabled a rapid profiling of the individual classes of compounds in crude combwaxes.  相似文献   

8.
基质固相分散-气相色谱/质谱法测定蔬菜中的邻苯二甲酸酯   总被引:13,自引:0,他引:13  
王明林  寇立娟  张玉倩  史衍玺 《色谱》2007,25(4):577-580
利用基质固相分散-气相色谱/质谱法测定了蔬菜中的邻苯二甲酸二甲酯、邻苯二甲酸二乙酯、邻苯二甲酸二丁酯、邻苯二甲酸丁基苄基酯和邻苯二甲酸二异辛酯。蔬菜样品经弗罗里硅土和石墨化炭黑研磨均匀后,用乙酸乙酯淋洗净化,结果表明:上述5种邻苯二甲酸酯在0.05~10.00 mg/L 范围内具有良好的线性,样品的添加回收率为76%~90%,相对标准偏差为2%~7%,5种邻苯二甲酸酯的检出限为0.01~0.024 mg/kg。该方法操作简便、经济,分析速度快,适用于大批量样品的分析。  相似文献   

9.
A detection method for 19 kinds of phthalic acid ester compounds analyzed by n‐hexane/ether/acetonitrile 1:7:8 v/v/v mixed solvent extraction, quick, easy, cheap, effective, rugged, and safe purification and internal standard method of quantitative gas chromatography with mass spectrometry was established. This method can effectively remove interfering materials, such as lipids, fatty acids, and pigments, from dairy products. The 19 kinds of phthalic acid ester compounds were within a 0.025–0.2 mg/kg range, the recovery rate was 65.2–125.7%, relative standard deviation was 7.9–15.4% (n = 6), and the limit of detection was 0.005–0.02 mg/kg. Concentrations of the 19 kinds of phthalic acid ester compounds ranged between 0.01 and 0.12 mg/kg in ten dairy materials and 20 dairy products. The established method is simple, rapid, accurate, and highly sensitive.  相似文献   

10.
Cycloalkylcarbonyl (cycloalkyl = cyclopropyl, cyclobutyl, cyclopentyl, and cyclohexyl) derivatives were proposed for the determination of amino acid methyl esters by gas chromatography–mass spectrometry. These compounds are readily formed with the quantitative yield on heating hydrochlorides of amino acid methyl esters with cycloalkylcarbonyl chlorides. Although these derivatives exhibit lower chromatographic mobility than acetyl or perfluoroacyl derivatives, they form symmetric peaks. Mechanisms of the fragmentation of the new class of compounds under electron ionization conditions were studied in detail using high-resolution mass spectra and analysis of metastable ions. It was demonstrated that cyclopentylcarbonyl and cyclohexylcarbonyl derivatives can decompose with the cleavage of carbocycles.  相似文献   

11.
Total phenolic choline ester fractions prepared from seeds of Arabidopsis thaliana and Brassica napus were analyzed by capillary LC/ESI‐QTOF‐MS and direct infusion ESI‐FTICR‐MS. In addition to the dominating sinapoylcholine, 30 phenolic choline esters could be identified based on accurate mass measurements, interpretation of collision‐induced dissociation (CID) mass spectra, and synthesis of selected representatives. The compounds identified so far include substituted hydroxycinnamoyl‐ and hydroxybenzoylcholines, respective monohexosides as well as oxidative coupling products of phenolic choline esters and monolignols. Phenolic choline esters are well separable by reversed‐phase liquid chromatography and sensitively detectable using electrospray ionization mass spectrometry in positive ion mode. CID mass spectra obtained from molecular ions facilitate the characterization of both the type and substitution pattern of such compounds. Therefore, LC/ESI‐MS/MS represents a valuable tool for comprehensive qualitative and quantitative analysis of this compound class. Copyright © 2008 John Wiley & Sons, Ltd.  相似文献   

12.
A method for fast determination of the component in complex samples by using gas chromatography‐mass spectrometry (GC‐MS) was developed and used for quantitative analysis of phenanthrene in soils. In the method, window independent component analysis (WICA) was used for resolving the mass spectrum and non‐negative immune algorithm (NNIA) was employed for obtaining the chromatographic profile. Therefore, spectral and chromatographic information of a specific component can be obtained from the measured GC‐MS data of overlapping and high background. Six soil samples collected from different places were analyzed. The tedious pretreatments in preparing the samples and the elution in the separation were simplified for speeding up the analysis. Due to the complexity of the matrix, standard addition method was adopted for the final quantification. The applicability of the method was validated with a spiked sample and the results of the six samples are reasonable.  相似文献   

13.
The phenolic components from Radix Salvia miltiorrhizae Bunge, a well-known herbal medicine (Dan-Shen in Chinese), have been investigated by high-performance liquid chromatography/electrospray ionization tandem mass spectrometry (HPLC/ESI-MS/MS). HPLC analyses were performed on a reversed-phase C18 column using gradient elution. In the ESI mass spectra a predominant [M-H]- ion was observed in negative mode and provided molecular mass information. ESI-MS/MS spectra of the [M-H]- ions were used for structural analysis, based on the spectra of standards. It was found that caffeic acid and its monomeric analogs containing a carboxyl group readily lost CO2, while dimers, trimers and tetramers of caffeic acid expelled successively danshensu or caffeic acid or their esters. Twenty-eight phenolic compounds in S. miltiorrhizae were characterized, of which eight compounds were positively identified by comparison with standards. The remaining twenty phenolics for which standards were not available were tentatively identified based on their UV spectra and MS/MS fragmentation characteristics.  相似文献   

14.
Retention indices of standard organic compounds of environmental interest were determined by gas chromatography/mass spectrometry, using a DB-5 fused-silica capillary column. Retention indices are useful references for tentative compound identification by gas chromatography, or confirmation by gas chromatography/mass spectrometry. They provide elution order for isomers that might be indistinguishable based on mass spectra. Modified Kovats and Lee retention indices are given for polycyclic aromatic hydrocarbons; sulfur heterocycles; nitrogen heterocycles; aromatic amines; oxygen heterocycles; phenols; alcohols; ketones; alkanes; nitriles; and methylesters of fatty, dicarboxylic, and aromatic acids for comparison and reference. Retention index values for heterocycles by gas chromatography/mass spectrometry are comparable with gas chromatography values previously reported.  相似文献   

15.
The formation of chlorinated phenols during the analysis of chromatographically pure polychloroalicyclic ketones by gas chromatography and gas chromatography-mass spectrometry was observed. Also in the mass spectra obtained by direct inlet, the presence of small amounts of chlorophenols was detected. The reasons of the formation of chlorophenols are discussed and qualitative and quantitative results obtained are interpreted.  相似文献   

16.
A new type of low thermal mass (LTM) fast gas chromatograph (GC) was designed and operated in combination with gas chromatography mass spectrometry (GC-MS) with supersonic molecular beams (SMB), including GC-MS-MS with SMB, thereby providing a novel combination with unique capabilities. The LTM fast GC is based on a short capillary column inserted inside a stainless steel tube that is resistively heated. It is located and mounted outside the standard GC oven on its available top detector port, while the capillary column is connected as usual to the standard GC injector and supersonic molecular beam interface transfer line. This new type of fast GC-MS with SMB enables less than 1 min full range temperature programming and cooling down analysis cycle time. The operation of the fast GC-MS with SMB was explored and 1 min full analysis cycle time of a mixture of 16 hydrocarbons in the C(10)H(22) up to C(44)H(90) range was achieved. The use of 35 mL/min high column flow rate enabled the elution of C(44)H(90) in less than 45 s while the SMB interface enabled splitless acceptance of this high flow rate and the provision of dominant molecular ions. A novel compound 9-benzylazidanthracene was analyzed for its purity and a synthetic chemistry process was monitored for the optimization of the chemical reaction yield. Biodiesel was analyzed in jet fuel (by both GC-MS and GC-MS-MS) in under 1 min as 5 ppm fatty acid methyl esters. Authentic iprodion and cypermethrin pesticides were analyzed in grapes extract in both full scan mode and fast GC-MS-MS mode in under 1 min cycle time and explosive mixture including TATP, TNT and RDX was analyzed in under 1 min combined with exhibiting dominant molecular ion for TATP. Fast GC-MS with SMB is based on trading GC separation for speed of analysis while enhancing the separation power of the MS via the enhancement of the molecular ion in the electron ionization of cold molecules in the SMB. This paper further discusses several features of fast GC and fast GC-MS and the various trade-offs involved in having powerful and practical fast GC-MS.  相似文献   

17.
Substituted benzeneboronic acids are important intermediates in the synthesis of support matrices for affinity chromatography but their analysis by mass spectrometry is hindered by thermal reactions in the ion source. A simple derivatization with 1,2- or 1,3-diols removes this difficulty and imparts sufficient volatility for application of gas chromatography/mass spectrometry. The mass spectra of the resulting boronate esters are discussed with reference to high resolution measurements, isotope labelling studies and observation of metastable ions. ortho Substituents are shown to interact strongly during fragmentation. Linked scanning at constant B/E was used to characterize fragmentation pathways and the compatibility of linked scanning and GC/MS is reported.  相似文献   

18.
A technique using comprehensive two-dimensional gas chromatography/time-of-flight mass spectrometry (GC × GC/TOFMS) is applied to a qualitative analysis of three sample extracts from hair suspected of containing various drug compounds. The samples were also subjected to a quantitative target analysis for codeine, morphine, 6-monoacetylmorphine (6-MAM), amphetamine, methamphetamine, methylenedioxyamphetamine (MDA), methylenedioxymethylamphetamine (MDMA), methadone, and benzylpiperazine (BZP) by liquid chromatography-tandem mass spectrometry (LC-MS/MS). GC × GC/TOFMS provided a non-specific procedure that identified various drugs, metabolites, and impurities not included in the target analysis. They included cocaine, diazepam, and methaqualone (quaalude). Comprehensive GC × GC separation was achieved using twin-stage cryo-modulation to focus eluant from a DB-5ms (5% phenyl) to a BPX50 (50% phenyl) GC column. The TOF mass spectrometer provided unit mass resolution in the mass range m/z 5–1000 and rapid spectral acquisition (≤500 spectra/s). Clean mass spectra of the individual components were obtained using mass spectral deconvolution software. The ‘unknown’ components were identified by comparison with mass spectra stored in a library database.  相似文献   

19.
The detection of corticosteroids and sex steroids in samples with no content indication, which are confiscated for forensic investigation, is a challenge in doping analysis. A screening method based on the identification of androgens, estrogens, gestagens, and their esters by means of a mass spectral library, along with a fast ultra-performance liquid chromatography–mass spectrometry (UPLC-MS) method, was recently developed in our lab for the analysis of dietary supplements. However, for forensic investigations, it is important to extend the scope of the method to corticosteroids in various matrices. Therefore, 36 corticosteroids were added to the mass spectral library, and the sample preparation step was modified so that androgens, gestagens, corticosteroids, and their esters could be analyzed with only one injection with the UPLC-MS method. A complementary tool to the existing library identification was found in the extraction of common fragment ions out of the full scan data obtained for the library search. The fragment ion with m/z 147 was found to be a good marker for the detection of steroids. Extra confirmation was obtained from the fragment ions with m/z 135 (for all steroids) and 237 (specific for corticosteroids) or from the fragment ions with m/z 77, 91, and 105. The effectiveness of this approach was evaluated on some samples previously screened for forensic investigation with thin-layer chromatography and confirmed with a targeted gas chromatography–mass spectrometry method. This study shows that the combination of the library identification and the common fragment ions approach can be a valuable tool in the detection of steroids without defining any target at the start of the analysis.  相似文献   

20.
A new method for the fast screening of cocaine and 6-monoacetylmorphine (6-MAM) in a single hair, using gas chromatography/mass spectrometry (GC/MS), is described. The analyses are conducted in less than 10 min with minimal sample preparation. The novel method combines the ChromatoProbe direct sample introduction device for intrainjector thermal extraction, fast GC separation, a supersonic molecular beam GC/MS interface and hyperthermal surface ionization (HSI). The technique has been successfully employed for the detection of cocaine in as little as a 1-mm section of hair using selected ion monitoring (SIM). Unambiguous full scan mass spectra of cocaine and 6-MAM were obtained on a single hair for cocaine and heroin users, respectively. HSI was found to be almost 3 orders of magnitude more selective than electron impact ionization for cocaine compared with the major hair constituents, with a minimum detected concentration of approximately 10 ppb in the SIM mode. Results obtained for 12 drug users showed full qualitative agreement with similar results using rigorous solvent extraction followed by electrospray-liquid chromatography/mass spectrometry analysis. However, quantitative studies showed only partial agreement. No false positives were observed for 10 drug free subjects. This method enables fast drug monitoring along the hair length which permits time correlation studies.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号