首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 860 毫秒
1.
The enantiomer separation of a number of racemic 7‐[(1‐alkylpiperidin‐3‐yl)methoxy]coumarin derivatives, some of which show outstanding in vitro multitarget neuroprotective activities, was successfully achieved on a polysaccharide‐based chiral stationary phase, bearing amylose tris(3,5‐dimethylphenylcarbamate) as a chiral selector, in normal polar mode (methanol and acetonitrile as the mobile phases). The majority of the screened selectands, especially those bearing 1‐(3‐X‐benzyl)piperidin‐3‐yl moieties, showed baseline enantiomer separations, and compound 8 (X = NO2) was the best resolved (α = 2.01; RS = 4.27). Linear free energy relationships, usefully complemented by molecular docking calculations, have the key role in enantioselective retention of aromatic interactions between π‐donor moieties in the chiral selector and π‐acceptor moieties in selectand, strengthened by hydrogen bond interaction between a hydrogen bond donor in the chiral selector and the hydrogen bond acceptor group(s) in the selectand. Statistically, reliable equations highlighted the importance of the substituent's size and substitution pattern (meta better than para) to affect the enantiorecognition of the title compounds. The chromatographic data support the scalability of the optimized experimental conditions for preparative purposes.  相似文献   

2.
Recycling high‐speed counter‐current chromatography was successfully applied to the preparative separation of oxybutynin enantiomers. The two‐phase solvent system consisted of n‐hexane, methyl tert‐butyl ether, and 0.1 mol/L phosphate buffer solution (pH = 5.0) with the volume ratio of 6:4:10. Hydroxypropyl‐β‐cyclodextrin was employed as the chiral selector. The influence of factors on the chiral separation process, including the concentration of chiral selector, the equilibrium temperature, the pH value of the aqueous phase were investigated. Under optimum separation conditions, 15 mg of oxybutynin racemate was separated with the purities of both the enantiomers over 96.5% determined by high‐performance liquid chromatography. Recovery for the target compounds reached 80–82% yielding 6.00 mg of (R)‐oxybutynin and 6.15 mg of (S)‐oxybutynin. Technical details for recycling elution mode were discussed.  相似文献   

3.
This paper presents a multi‐residue method for direct enantioselective separation of chiral pharmacologically active compounds in environmental matrices. The method is based on chiral liquid chromatography and tandem mass spectrometry detection. Simultaneous chiral discrimination was achieved with a macrocyclic glycopeptide‐based column with antibiotic teicoplanin as a chiral selector working under reverse phase mode. For the first time, enantioresolution was reported for metabolites of ibuprofen: carboxyibuprofen and 2‐hydroxyibuprofen with this chiral stationary phase. Moreover, enantiomers of chloramphenicol, ibuprofen, ifosfamide, indoprofen, ketoprofen, naproxen and praziquantel were also resolved. The overall performance of the method was satisfactory in terms of linearity, precision, accuracy and limits of detection. The method was successfully applied for monitoring of pharmacologically active compounds at enantiomeric level in influent and effluent wastewater and in river water. In addition, the chiral recognition and analytical performance of the teicoplanin‐based column was critically compared with that of the α1‐acid glycoprotein chiral stationary phase. Copyright © 2017 John Wiley & Sons, Ltd.  相似文献   

4.
5.
In the present study, an in silico methodology able to define the binding modes adopted by carnosine enantiomers in the setting of the chiral recognition process is described. The inter‐ and intramolecular forces involved in the enantioseparation process with the Teicoplanin A2‐2 chiral selector and carnosine as model compound are successfully identified. This approach fully rationalizes, at a molecular level, the (S) < (R) enantiomeric elution order obtained under reversed‐phase conditions. Consistent explanations were achieved by managing molecular dynamics results with advanced techniques of data analysis. As a result, the time‐dependent identification of all the interactions simultaneously occurring in the chiral selector‐enantiomeric analyte binding process was obtained. Accordingly, it was found that only (R)‐carnosine is able to engage a stabilizing charge–charge interaction through its ionized imidazole ring with the carboxylate counter‐part on the chiral selector. Instead, (S)‐carnosine establishes intramolecular contacts between its ionized functional groups, that limit its conformational freedom and impair the association with the chiral selector unit.  相似文献   

6.
He  Xiaomei  Lin  Rui  He  Hua  Sun  Meiling  Xiao  Deli 《Chromatographia》2012,75(23):1355-1363
Purpose

In this study, direct separation of ketoprofen enantiomers was performed on a Chirobiotic T column.

Methods

The effects of the type and amount of the organic modifier, buffer concentration, pH value, temperature and flow rate on retention and selectivity were investigated. Experiments were carried out in the temperature range of 20–40 °C to study the effects of temperature. Thermodynamic parameters were calculated from plots of ln k or ln α versus 1/T. Molecular dynamics simulation was done to investigate interactions between ketoprofen enantiomers and the chiral selector—teicoplanin.

Results

It was observed that pH and flow rate had a large influence on resolution. Baseline separation of ketoprofen enantiomers could be achieved with low amounts of methanol, high temperature and high buffer concentrations.

Conclusions

Results from a thermodynamic study and molecular dynamics simulation show that steric hindrance effect, π–π complexation, hydrogen bonding and electrostatic forces are the main driving forces which cause chiral recognition of ketoprofen enantiomers.

  相似文献   

7.
The application of chemical‐modified gold nanoparticles (GNPs) as chiral selector for the enantioseparation based on pseudostationary phase‐CEC (PSP‐CEC) is presented. GNPs modified by thiolated β‐CD were characterized by NMR and FT‐IR. The nanoparticle size was determined to be of 9.5 nm (+2.5 nm) by Transmission Electron Microscopy (TEM) and UV spectra. Four pairs of dinitrophenyl‐labeled amino acid enantiomers (DL‐Val, Leu, Glu and Asp) and three pairs of drug enantiomers (RS‐chlorpheniramine, zopiclone and carvedilol) were analyzed by using modified GNPs as the chiral selector in PSP‐CEC. Good theoretical plate number (up to 2.4×105 per meter) and separation resolution (up to 4.7) were obtained even with low concentration of modified GNPs (0.8–1.4 mg/mL). The corresponding concentration of β‐CD in the buffer was only 0.30?0.53 mM, which was much lower than the optimum concentration of 15 mM if pure β‐CD was used as chiral selector. Our results showed that thiolated β‐CD modified GNPs have more sufficient interaction with the analytes, resulting in significant enhancement of enantioseparation. The study shed light on potential usage of chemical modified GNPs as chiral selector for enantioseparation based on PSP‐CEC.  相似文献   

8.
A review of atomistic molecular modeling studies related to chromatographic separations of enantiomers is presented. Only those types of calculations where direct interactions between a selector and a selectand are involved are described in this review; omitted are regression models. An emphasis is placed on comparing methods used for sampling potential energy surfaces implementing different methodologies like quantum and molecular mechanics for energy calculations, and molecular dynamics and Monte Carlo sampling strategies for simulations. Type I-V chiral stationary phases and additives for capillary electrophoresis and ion-pair chromatography are covered in this review.  相似文献   

9.
This paper extends the research of the utilization of borate coordination complexes in chiral separation by counter‐current chromatography (CCC). Racemic propafenone was successfully enantioseparated by CCC with di‐n‐butyl l ‐tartrate combined with boric acid as the chiral selector. The two‐phase solvent system was composed of chloroform/ 0.05 mol/L acetate buffer pH 3.4 containing 0.10 mol/L boric acid (1:1, v/v), in which 0.10 mol/L di‐n‐butyl l ‐tartrate was added in the organic phase. The influence of factors in the enantioseparation of propafenone were investigated and optimized. A total of 92 mg of racemic propafenone was completely enantioseparated using high‐speed CCC in a single run, yielding 40–42 mg of (R)‐ and (S)‐propafenone enantiomers with an HPLC purity over 90–95%. The recovery for propafenone enantiomers from fractions of CCC was in the range of 85–90%.  相似文献   

10.
A new ligand exchange chiral stationary phase (new CSP) containing residual silanol group‐protecting n‐octyl groups on the silica surface was prepared by treating a ligand exchange CSP (original CSP) based on sodium N‐[(R)‐2‐hydroxy‐1‐phenylethyl]‐N‐undecylaminoacetate bonded to silica gel with excess n‐octyltriethoxysilane. The new and original CSPs containing an identical amount of chiral selector were applied to the resolution of α‐amino acids and proton pump inhibitors (PPIs) including omeprazole, pantoprazole, lansoprazole, and rabeprazole. The separation factors (α) and resolutions (RS) were greater on the new CSP than on the original CSP except for the resolution of asparagine. The trends of the retention factors (k1) for the resolution of α‐amino acids on the new and original CSPs with the variation of the organic modifier content in aqueous mobile phase were opposite to those for the resolution of PPIs. Removal of the nonenantioselective interactions between the residual silanol groups and the analytes and the improved lipophilicity of the new CSP were proposed to be responsible for the improved chiral recognition ability of the new CSP and the different retention behaviors of the enantiomers between the new and original CSPs.  相似文献   

11.
RP high‐performance liquid chromatographic methods were developed for the enantioseparation of eleven unusual β2‐homoamino acids. The underivatized analytes were separated on a chiral stationary phase containing (+)‐(18‐crown‐6)‐2,3,11,12‐tetracarboxylic acid as chiral selector. The effects of organic (alcoholic) and acidic modifiers, the mobile phase composition and temperature on the separation were investigated. The structures of the substituents in the α‐position of the analytes substantially influenced the retention and resolution. The elution sequence was determined in some cases: the S enantiomers eluted before the R enantiomers.  相似文献   

12.
To improve resolution power of chiral selector and enantiomeric peak efficiency in CE, single isomer negatively charged β‐CD derivatives, mono(6‐deoxy‐6‐sulfoethylthio)‐β‐CD (SET‐β‐CD) bearing one negative charge and mono[6‐deoxy‐6‐(6‐sulfooxy‐5,5‐bis‐sulfooxymethyl)hexylthio]‐β‐CD (SMHT‐β‐CD) carrying three negative charges, were synthesized. The structure of these two β‐CD derivatives was confirmed by 1H NMR and MS. SET‐β‐CD and SMHT‐β‐CD successfully resolved the enantiomers of several basic model compounds. SMHT‐β‐CD provided for a significantly greater enantioseparation than SET‐β‐CD at lower concentrations. This appears to be due to the higher binding affinity of SMHT‐β‐CD to the model compounds and the wider separation window resulting from an increased countercurrent mobility of the selector. Overall, the new chiral selectors provided enantioseparations with high peak efficiency while avoiding peak distortion due to polydispersive and electrodispersive effects. The information obtained from an apparent binding constant study suggested that the enantioseparation of the model compounds followed the predictions of charged resolving agent migration model and that the observed degree of enantioseparation difference were due to the magnitude of differences in both enantiomer‐chiral selector binding affinities (ΔK) and the mobilities of the complexed enantiomers (Δμc).  相似文献   

13.
Xiaomei He  Rui Lin  Hua He  Meiling Sun  Deli Xiao 《Chromatographia》2012,75(23-24):1355-1363

Purpose

In this study, direct separation of ketoprofen enantiomers was performed on a Chirobiotic T column.

Methods

The effects of the type and amount of the organic modifier, buffer concentration, pH value, temperature and flow rate on retention and selectivity were investigated. Experiments were carried out in the temperature range of 20?C40?°C to study the effects of temperature. Thermodynamic parameters were calculated from plots of ln k or ln ?? versus 1/T. Molecular dynamics simulation was done to investigate interactions between ketoprofen enantiomers and the chiral selector??teicoplanin.

Results

It was observed that pH and flow rate had a large influence on resolution. Baseline separation of ketoprofen enantiomers could be achieved with low amounts of methanol, high temperature and high buffer concentrations.

Conclusions

Results from a thermodynamic study and molecular dynamics simulation show that steric hindrance effect, ?ШC?? complexation, hydrogen bonding and electrostatic forces are the main driving forces which cause chiral recognition of ketoprofen enantiomers.  相似文献   

14.
An LC method was developed and prevalidated for the enantiomeric purity determination of S‐amlodipine in polar organic solvent chromatography using a chlorine‐containing cellulose‐based chiral stationary phase (CSP). The concentration of formic acid (FA) (0.01–0.2%) in the mobile phase containing acetonitrile as the main solvent was found to influence the elution order of amlodipine enantiomers as well as the enantioresolution. A reversal of the enantiomer elution order of amlodipine was only observed with chiral stationary phases with both electron‐withdrawing (chloro) and electron‐donating groups (methyl) on the phenyl moieties of the chiral selector, namely cellulose tris(3‐chloro‐4‐methylphenylcarbamate) and cellulose tris(4‐chloro‐3‐methylphenylcarbamate). The highest enantioresolution (Rs: 4.1) value was obtained at the lowest FA concentration (0.01%) using cellulose tris(4‐chloro‐3‐methylphenylcarbamate) as the chiral selector and the enantiomeric impurity, R‐amlodipine, eluted first under these conditions. Therefore, the mobile phase selected for the prevalidation of the method consisted of ACN/0.1% DEA/0.01% FA and the temperature was set at 25°C. The method was prevalidated by means of the strategy based on the total measurement error and the accuracy profile. The method was found to be selective and the limit of quantification was found to be about 0.05% for R‐amlodipine, while the limit of detection was close to 0.02%.  相似文献   

15.
Recycling countercurrent chromatography was successfully applied to the resolution of 2‐(4‐bromomethylphenyl)propionic acid, a key synthetic intermediate for synthesis of nonsteroidal anti‐inflammatory drug loxoprofen, using hydroxypropyl‐β‐cyclodextrin as chiral selector. The two‐phase solvent system composed of n‐hexane/n‐butyl acetate/0.1 mol/L citrate buffer solution with pH 2.4 (8:2:10, v/v/v) was selected. Influence factors for the enantioseparation were optimized, including type of substituted β‐cyclodextrin, concentration of hydroxypropyl‐β‐cyclodextrin, separation temperature, and pH of aqueous phase. Under optimized separation conditions, 50 mg of 2‐(4‐bromomethylphenyl)propionic acid was enantioseparated using preparative recycling countercurrent chromatography. Technical details for recycling elution mode were discussed. The purities of both the S and R enantiomers were over 99.0% as determined by high‐performance liquid chromatography. The enantiomeric excess of the S and R enantiomers reached 98.0%. The recovery of the enantiomers from eluted fractions was 40.8–65.6%, yielding 16.4 mg of the S enantiomer and 10.2 mg of the R enantiomer. At the same time, we attempted to enantioseparate the anti‐inflammatory drug loxoprofen by countercurrent chromatography and high‐performance liquid chromatography using a chiral mobile phase additive. However, no successful enantioseparation was achieved so far.  相似文献   

16.
The potential of using CE frontal analysis (CE‐FA) to study the interactions between a range of charged low molecular weight drug substances and liposomes was evaluated. The liposomes used were net negatively charged and consisted of 2‐oleoyl‐1‐palmitoyl‐sn‐glycero‐3‐phosphocholine and 1,2‐dipalmitoyl‐sn‐glycero‐3‐phosphate monosodium salt in a ratio of 80/20 mol%. Apparent distribution coefficients (Dmem), defined as the molar concentration of drug substance in the membrane phase divided by the molar concentration of drug substance in the aqueous phase, were successfully determined for six positively and eight negatively charged drug substances with log Dmem ranging from 1.35 to 3.63. The extent of liposome–buffer distribution was found to be dependent on the drug concentration. The results obtained with the developed CE‐FA method were in good agreement with results obtained by equilibrium dialysis. Furthermore, the CE‐FA method was faster, less labor intensive and required smaller sample volumes (~50 μL) compared with equilibrium dialysis. Thus, CE‐FA is an efficient and useful tool for the characterization of interactions between liposomes and low molecular weight drug substances.  相似文献   

17.
Various chiral selectors have been employed in CE and among them linear polysaccharides exhibited powerful enantioselective properties. Different from linear polysaccharides, the use of branched polysaccharides as chiral selectors in CE has not been reported previously. In this study glycogen belonging to the class of branched polysaccharides was used as a novel chiral selector for the enantiomeric separations for the first time. Since glycogen is electrically neutral, the method is applicable to ionic compounds. Eighteen chiral compounds including 12 basic drugs and six acidic drugs have been tested to demonstrate the potential of this chiral selector. BGE and selector concentrations and buffer pH were systematically optimized in order to obtain successful chiral separations. Among the tested compounds, the enantiomers of ibuprofen, which is an acidic drug, were successfully recognized by 3.0% w/v glycogen with 90 mM Tris‐H3PO4 buffer (pH 7.0). The enantiomers of basic drugs such as citalopram, cetirizine and nefopam were also baseline‐resolved with 50 mM Tris‐H3PO4 buffer (pH 3.0) containing 3.0% glycogen. Amlodipine belonging to basic compound only gave partial enantioseparation under the above‐mentioned condition.  相似文献   

18.
The enantio‐separations of eight 2‐arylpropionic acid nonsteroidal anti‐inflammatory drugs (2‐APA NSAIDs) were established using reversed‐phase high‐performance liquid chromatography with hydroxypropyl‐β‐cyclodextrin (HP‐β‐CD) as chiral mobile phase additive for studying the stereoselective skin permeation of suprofen, ketoprofen, naproxen, indoprofen, fenoprofen, furbiprofen, ibuprofen and carprofen. The effects of the mobile phase composition, concentration of HP‐β‐CD and column temperature on retention and enantioselective separation were investigated. With 2‐APA NSAIDs as acidic analytes, the retention times and resolutions of the enantiomers were strongly related to the pH of the mobile phase. In addition, both the concentration of HP‐β‐CD and temperature had a great effect on retention time, but only a slight or almost no effect on resolutions of the analytes. Enantioseparations were achieved on a Shimpack CLC‐ODS (150 × 4.6 mm i.d., 5 μm) column. The mobile phase was a mixture of methanol and phosphate buffer (pH 4.0–5.5, 20 mM) containing 25 mM HP‐β‐CD. This method was flexible, simple and economically advantageous over the use of chiral stationary phase, and was successfully applied to the enantioselective determination of the racemic 2‐APA NSAIDs in an enantioselective skin permeation study. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

19.
In this work is described the investigation of bivalent versus monovalent enantioselective molecular recognition in the context of enantioselective separations. Electrospray ionization-mass spectrometry (ESI-MS) and tandem mass spectrometry (MS/MS) are used for evaluating enantioselective systems through the measurement of (1) relative solution-phase binding constants via titration and (2) relative gas-phase binding via collision threshold dissociation. In HPLC, a cinchonane-type chiral stationary phase (CSP) based on tert.-butylcarbamoylquinine provides vastly increased retention and enantioselectivity for separation of bivalent versus monovalent alkoxy-benzoyl-N-blocked leucine enantiomers. The bivalent enantiomers are able to span and simultaneously interact with multiple interaction sites on the CSP surface, leading to enhanced separation. ESI-MS titration measurements also show an increased avidity for binding between bivalent selector and bivalent selectand, compared with the monovalent system. However, enhanced enantioselectivities measured in HPLC for the bivalent system cannot be reproduced by MS due to inherent mechanistic differences. Assumed discrepancies in relative response factors also give rise to systematic errors which are discussed. The results of MS/MS gas-phase experiments show that enantioselectivity is essentially lost in the absence of solvation, but that dissociation thresholds can provide a measure of relative dissociation energy in the bivalent interaction system compared to the monovalent counterpart. Such measurements may prove useful and efficient in better understanding multivalent interactions, in line with current theoretical considerations of effective concentrations and ion trap effects. This is the first application of mass spectrometric methods for assessing increased avidity of binding in multivalent enantioselective molecular recognition.  相似文献   

20.
The methods for the enantioseparation of m‐nisoldipine, a new 1,4‐dihydropyridine calcium ion antagonist, were developed. The elaborated methods of m‐nisoldipine enantiomers separation were successfully performed using an anionic CD–sulfobutyl ether‐β‐CD (SBE‐β‐CD) or carboxymethyl‐β‐CD as chiral selector. However, the results indicated that SBE‐β‐CD was a better chiral selector for enantioseparation of the neutral m‐nisoldipine. Furthermore, comparing the two SBE‐β‐CDs, the derivative with a higher degree of substitution (DS) of 7.0 induced better enantioresolution than the one with low DS (4.0). In addition, possible chiral recognition mechanisms of dihydropyridines were discussed.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号