Cotinine, the main metabolite of nicotine in human body, is widely used as a biomarker for assessment of direct or passive exposure to tobacco smoke. A method for molecularly imprinted solid-phase extraction (MISPE) of cotinine from human urine has been investigated. The molecularly imprinted polymer (MIP) with good selectivity and affinity for cotinine was synthesized using cotinine as the template molecule, methacrylic acid as the functional monomer, and ethylene glycol dimethacrylate as the cross-linker. The imprinted polymer was evaluated for use as a SPE sorbent, in tests with aqueous standards, by comparing recovery data obtained using the imprinted form of the polymer and a non-imprinted form (NIP). Extraction from the aqueous solutions resulted in more than 80% recovery. A range of linearity for cotinine between 0.05 and 5 μg mL−1 was obtained by loading 1 mL blank urine samples spiked with cotinine at different concentrations in acetate buffer of pH 9.0, and by using double basic washing and acidic elution. The intra-day coefficient of variation (CV) was below 7% and inter-day CV was below 10%. This investigation has provided a reliable MISPE–HPLC method for determination of cotinine in human urine from both active smokers and passive smokers. Figure  相似文献   

2.
In this paper we describe, for the first time, a molecularly imprinted polymer (MIP) for the antibiotic amoxicillin (AMX), synthesised by a noncovalent molecular imprinting approach and used to extract AMX selectively from urine samples. The MIP was applied as a molecularly selective sorbent in molecularly imprinted SPE (MISPE) in an off-line mode, where it showed useful cross-selectivity for a structurally related antibiotic, cephalexin (CPX). By using a MISPE protocol, the MIP was able to selectively extract both AMX and CFX from 5 mL of water spiked with 10 mg/L with recoveries of 75 and 78% for AMX and CFX, respectively. When applied to real samples (urine) at clinically relevant concentrations, recoveries from 2 mL of human urine spiked with 20 mg/L decreased slightly to 65 and 63% for AMX and CFX, respectively. To demonstrate further the selectivity of the MIP obtained, a comparison with commercially available SPE cartridges was performed. Improvements in the retention of both AMX and CFX on the MIP were obtained relative to the commercially available cartridges, and the MISPE extracts were considerably cleaner, due to molecularly selective analyte binding by the MIP.  相似文献   

3.
In this work, novel magnetic molecularly imprinted polymers were prepared for the selective extraction of osthole from Libanotis Buchtomensis herbal extract. During the synthesis process, double bonds grafted on the surface of Fe3O4 nanoparticles could not only drive the temple molecules to locate onto the surface of vinyl‐functionalized magnetic nanoparticles by π–π conjugation, which makes the distribution of binding sites ordered, but also direct the occurrence of imprinting polymerization at the surface of magnetic nanoparticles by the copolymerization of vinyl terminal groups with functional monomers and cross‐linking agent. The characteristics of the resulting polymers were evaluated by transmission electron microscopy, X‐ray diffraction, Fourier‐transform infrared spectroscopy, and vibrating sample magnetometry. Adsorption kinetics, isotherms, selectivity, reproducibility, and reusability were discussed, which suggest that the obtained nanomaterials possess rapid binding kinetics, high adsorption capacity of 17.65 mg/g, and favorable selectivity for the target molecule. Satisfactory reproducibility and reusability were verified as well. Meanwhile, the resultant imprinted nanoparticles were successfully applied to selectively separate osthole from the herbal extract, which show great potential in extracting active ingredients from traditional Chinese medicine.  相似文献   

4.
Using nanoattapulgite as matrix, both diethylstilbestrol surface molecularly imprinted polymer and non-imprinted polymer were synthesized in this work. Compared with each other, the diethylstilbestrol surface molecularly imprinted polymer is superior to non-imprinted polymer in adsorption capacity, selectivity and mass transfer property. The maximum static adsorption capacities of diethylstilbestrol surface molecularly imprinted polymer, non-imprinted polymer and nanoattapulgite for diethylstilbestrol was 105.14, 78.54 and 28.50 mg g−1, respectively. As the packing material of solid-phase extraction, the diethylstilbestrol surface molecularly imprinted polymer has been applied to concentrating diethylstilbestrol in pond water and fish samples. A corresponding analytical method to determine diethylstilbestrol has been developed. The limit of detection for diethylstilbestrol in pond water sample and fish samples were 3 μg L−1 and 15 μg kg−1.  相似文献   

5.
A novel water-compatible molecularly imprinted polymer (MIP), prepared with enrofloxacin (ENR) as the template, has been optimised for the selective extraction of fluoroquinolone antibiotics in aqueous media. The results of a morphological characterisation and selectivity tests of the polymer material for ENR and related derivatives are reported. High affinity for the piperazine-based fluoroquinolones marbofloxacin, ciprofloxacin, norfloxacin and ofloxacin was observed, whereas no retention was found for nonrelated antibiotics. Various parameters affecting the extraction efficiency of the polymer have been optimised to achieve selective extraction of the antibiotics from real samples and to reduce nonspecific interactions. These findings resulted in a MISPE/HPLC-FLD method allowing direct extraction of the analytes from aqueous samples with a selective wash using just 50% (v/v) organic solvent. The method showed excellent recoveries and precision when buffered urine samples fortified at five concentration levels (25–250 ng mL−1 each) of marbofloxacin, ciprofloxacin, norfloxacin, enrofloxacin and sarafloxacin were tested (53–88%, RSD 1–10%, n = 3). Moreover, the biological matrix of the aqueous samples did not influence the preconcentration efficiency of the fluoroquinolones on the MIP cartridges; no significant differences were observed between the recovery rates of the antibiotics in buffer and urine samples. The detection limits of the whole process range between 1.9 and 34 ng mL–1 when 5-mL urine samples are processed. The developed method has been successfully applied to preconcentration of norfloxacin in urine samples of a medicated patient, demonstrating the ability of the novel MIP for selective extraction of fluoroquinolones in urine samples.  相似文献   

6.
A method is proposed for the clean-up and preconcentration of natural and synthetic estrogens from aqueous samples employing molecularly imprinted polymer (MIP) as selective sorbent for solid-phase extraction (SPE). The selectivity of the MIP was checked toward several selected natural and synthetic estrogens such as estrone (E1), 17β-estradiol (β-E2), 17α-estradiol (α-E2), estriol (E3), 17α-ethinylestradiol (EE2), dienestrol (DIES) and diethylstilbestrol (DES). Ultrahigh pressure liquid chromatography (UHPLC) coupled to a TSQ triple quadrupole mass spectrometry (QqQ) was used for analysis of target analytes. The chromatographic separation of the selected compounds was performed in less than 2 min under isocratic conditions. The method was applied to the analysis of estrogens in spiked river and tap water samples. High recoveries (>82%) for estrone, 17β-estradiol, 17α-estradiol, estriol and 17α-ethinylestradiol were obtained. Lower but still satisfactory recoveries (>48%) were achieved for dienestrol and diethylstilbestrol. The method was validated and found to be linear in the range 50-500 ng L(-1) with correlation coefficients (R(2)) greater than 0.995 and repeatability relative standard deviation (RSD) below 8% in all cases. For analysis of 100-mL sample, the method detection limits (LOD) ranged from 4.5 to 9.8 ng L(-1) and the limit of quantitation (LOQ) from 14.9 to 32.6 ng L(-1). To demonstrate the potential of the MIP obtained, a comparison with commercially available C(18) SPE was performed. Molecularly imprinted SPE showed higher recoveries than commercially available C(18) SPE for most of the compounds. These results showed the suitability of the MIP-SPE method for the selective extraction of a class of structurally related compounds such as natural and synthetic estrogens.  相似文献   

7.
A new molecularly imprinted polymer, prepared following a non-covalent approach, was synthesised using enrofloxacin as a template molecule. The imprinting effect of the polymer was verified by chromatographic evaluation and, interestingly, this evaluation also revealed that the imprinted polymer showed a high degree of cross-reactivity for ciprofloxacin, the major metabolite of enrofloxacin. The molecularly imprinted polymer was then applied as a selective sorbent in a two-step solid-phase extraction method focussing upon complex biological matrices, specifically human urine and pig liver. This two-step solid-phase extraction protocol, in which a commercial Oasis HLB cartridge and a molecularly imprinted solid-phase extraction cartridge were combined, allowed enrofloxacin and ciprofloxacin to be determined by liquid chromatography coupled to a UV detector at levels below the maximum residue limits established by the European Union. The quantification and detection limits in tissue samples of enrofloxacin and ciprofloxacin were established at 50 μg kg−1 and 30 μg kg−1, respectively.  相似文献   

8.
Rao RN  Maurya PK  Khalid S 《Talanta》2011,85(2):950-957
A novel water-compatible molecularly imprinted solid-phase extraction (MISPE) combined with zwitterionic hydrophilic interaction liquid chromatography (ZIC-HILIC) method for selective extraction and determination of sitagliptin in rat serum and urine was developed and validated. The effects of progenic solvents, pH, cross linker and amount of monomer were studied to optimize the efficiency and selectivity. The adsorption kinetics and isotherms were measured. The molecularly imprinted polymer (MIP) showed good specific adsorption capacity with an optimum of 180 mg/g at pH 7.5 and selective extraction of sitagliptin from rat plasma and urine. The recovery of sitagliptin from rat urine and plasma was >98%. The limits of detection (LOD) and quantification (LOQ) were 0.03 and 0.10 μg/L respectively. The proposed method overcomes the matrix effects of phospholipids generally encountered while preparation of plasma samples by precipitation of proteins.  相似文献   

9.
Stir‐bar sorptive extraction is based on the partitioning of target analytes between the sample (mostly aqueous‐based liquid samples) and a stationary phase‐coated magnetic stir bar. Until now, only PDMS‐coated stir bars are commercially available, restricting the range of applications to the non‐selective extraction of hydrophobic compounds due to the apolar character of PDMS. In this work, a novel stir bar coated with molecularly imprinted polymer as selective extraction phase for sorptive extraction of thiabendazole (TBZ) was developed. Two different procedures, based on physical or chemical coating, were assessed for the preparation of molecularly imprinted stir bars. Under optimum conditions, recoveries achieved both in imprinted and non‐imprinted polymer stir bars obtained by physical coating were very low, whereas TBZ was favourably retained by imprinted over non‐imprinted polymer stir bars obtained by chemical coating and thus the latter approach was used in further studies. Different parameters affecting both stir‐bars preparation (i.e. cross‐linker, porogen, polymerization time) and the subsequent selective extraction of TBZ (i.e. washing, loading and elution solvents, extraction time) were properly optimized. The molecularly imprinted coated stir bars were applied to the extraction of TBZ from citrus samples (orange, lemon and citrus juices) allowing its final determination at concentrations levels according to current regulations.  相似文献   

10.
ABSTRACT

In this work, a magnetic molecularly imprinted polymer (Fe3O4@SiO2@MIPs) was prepared via a surface-imprinted method for the determination of the triazines in environmental water samples combined with high-performance liquid chromatography tandem mass spectrometry (HPLC-MS/MS). The Fourier transform infrared spectroscopy (FTIR) and vibrating sample magnetometer showed that the Fe3O4@SiO2@MIPs was successfully synthesised and exhibited superparamagnetism. The isotherm adsorption, selectivity and adsorption kinetics experiments showed that the Fe3O4@SiO2@MIPs exhibited excellent specific recognition and fast adsorption equilibrium for triazines. The adsorption process is spontaneous and endothermic. The isotherm adsorption was consistent with Scatchard model and adsorption kinetic fit pseudo-second-order kinetic model. Under the optimised adsorption conditions, the Fe3O4@SiO2@MIPs was directly used to selectively enrich six triazines in environmental water samples. The enrichment volume was up to 500 mL, and the matrix effects were down to 0.7–12.4%. The built method has excellent linearities in the range of 0.25–500 ng L?1 with R2 in the range of 0.998–0.999, lower limit of detections (0.02–0.08 ng L?1) and higher precision (2.4–7.2%). The Fe3O4@SiO2@MIPs is expected to be widely applied to the direct enrichment of triazines in bulk environmental water samples.  相似文献   

11.
A new approach, combining metal coordination with the molecular imprinting technique, was developed to prepare affinity materials. Magnetic poly(glycidyl methacrylate) microspheres in monosize form were used for specific recognition toward the target protein. The magnetic poly(glycidyl methacrylate) microspheres were prepared by dispersion polymerization in the presence of magnetite nanopowder. Surface imprinted magnetic poly(glycidyl methacrylate) microspheres based on metal coordination were prepared and used for the selective recognition of human serum albumin. Iminodiacetic acid was used as the metal coordinating agent and human serum albumin was anchored by Cu2+ ions on the surface of magnetic poly(glycidyl methacrylate) microspheres by metal coordination. The magnetic poly(glycidyl methacrylate) microspheres were coated with a polymer formed by condensation of tetraethyl orthosilicate and 3‐aminopropyltrimethoxysilane. The human serum albumin imprinted magnetic poly(glycidyl methacrylate) microspheres were characterized by scanning electron microscopy, attenuated total reflectance Fourier transform infrared spectroscopy and particle size analysis. The maximum adsorption capacity of human serum albumin imprinted magnetic poly(glycidyl methacrylate) microspheres was 37.7 mg/g polymer at pH 6.0. The selectivity experiments of human serum albumin imprinted magnetic poly(glycidyl methacrylate) microspheres prepared with different concentrations in the presence of lysozyme, bovine serum albumin and cytochrome C were performed in order to determine the relative selectivity coefficients.  相似文献   

12.
A molecularly imprinted polymer has been synthesized to specifically extract adefovir, an antiviral drug, from serum and urine by dispersive solid‐phase extraction before high‐performance liquid chromatography with UV analysis. The imprinted polymers were prepared by bulk polymerization by a noncovalent imprinting method that involved the use of adefovir (template molecule) and functional monomer (methacrylic acid) complex prior to polymerization, ethylene glycol dimethacrylate as cross‐linker, and chloroform as porogen. Molecular recognition properties, binding capacity, and selectivity of the molecularly imprinted polymers were evaluated and the results show that the obtained polymers have high specific retention and enrichment for adefovir in aqueous medium. The new imprinted polymer was utilized as a molecular sorbent for the separation of adefovir from human serum and urine. The serum and urine extraction of adefovir by the molecularly imprinted polymer followed by high‐performance liquid chromatography showed a linear calibration curve in the range of 20–100 μg/L with excellent precisions (2.5 and 2.8% for 50 μg/L), respectively. The limit of detection and limit of quantization were determined in serum (7.62 and 15.1 μg/L), and urine (5.45 and 16 μg/L). The recoveries for serum and urine samples were found to be 88.2–93.5 and 84.3–90.2%, respectively.  相似文献   

13.
A molecularly imprinted polymer (MIP) based on free‐radical polymerization was prepared with 1‐(N,N‐biscarboxymethyl)amino‐3‐allylglycerol and N,N‐dimethylacrylamide as functional monomers, N,N‐methylene diacrylamide as the cross‐linker, copper ion‐clonazepam as the template and 2,2‐azobis(2‐methylbutyronitrile) as the initiator. The imprinted polymer was characterized by Fourier transform infrared spectroscopy, elemental analysis, thermogravimetric analysis, and SEM. The MIP of agglomerated microparticles with multipores was used for SPE. The imprinted polymer sorbent was selective for clonazepam. The optimum pH and sorption capacity were 5 and 0.18 mg/g at 20°C, respectively. The profile of the drug uptake by the sorbent reflects good accessibility of the active sites in the imprinted polymer sorbent. The MIP‐SPE was the most feasible technique for the extraction of clonazepam with a high recovery from human plasma and urine samples.  相似文献   

14.
A molecularly imprinted polymer (MIP) against lamotrigine (LTG) was prepared, characterized, and its recognition properties were compared with a blank nonimprinted polymer (NIP). Two classes of binding sites were found in the MIP--high affinity (K(D) = 16.2 microM) and low affinity (K(D) = 161.3 microM). Selectivity of the synthesized MIP was examined using compounds with similar structures or therapeutic uses to LTG. In compounds which had structural similarity to LTG, the presence of amine groups appeared to affect binding to the MIP, however overall shape of the molecule was also important. Under the optimal conditions developed, other anticonvulsant drugs tested did not bind the MIP. A molecularly imprinted SPE (MISPE) procedure was developed which had a recovery of 84-89%, interday variation of less than 3.4% and intraday variation of less than 2.8%. The MISPE procedure was compared with a routine liquid-liquid extraction (LLE) procedure used for the HPLC determination of LTG in serum from patients. The data indicated that the MIP synthesized showed both good selectivity and high affinity for LTG and could be used for the extraction of the drug from serum samples or as the receptor layer for an LTG selective biosensor.  相似文献   

15.
In this work, a novel magnetic nanomaterial functionalized with a molecularly imprinted polymer was prepared for the extraction of protoberberine alkaloids. Molecularly imprinted polymers were made on the surface of Fe3O4 nanoparticles by using berberine as template, acetonitrile/water as porogen, acrylamide as functional monomer and ethylene glycol dimethacrylate as cross‐linker. The optimized molar ratio of template/functional monomer was 1:7. The polymeric magnetic nanoparticles were characterized by transmission electron microscopy and Fourier transform infrared spectroscopy. The stability and adsorption capacity of the molecularly imprinted polymers were investigated. The molecularly imprinted polymers were used as a selective sorbent for the magnetic molecularly imprinted solid‐phase extraction and determination of jatrorrhizine, palmatine, and berberine. Extraction parameters were studied including loading pH, sample volume, stirring speed, and extraction time. Finally, a magnetic molecularly imprinted solid‐phase extraction coupled to high‐performance liquid chromatography method was developed. Under the optimized conditions, the method showed good linear range of 0.1–150 ng/mL for berberine and 0.1–100 ng/mL for jatrorrhizine and palmatine. The limit of detection was 0.01 ng/mL for berberine and 0.02 ng/mL for jatrorrhizine and palmatine. The proposed method has been applied to determine protoberberine alkaloids in Cortex phellodendri and rat plasma samples. The recoveries ranged from 87.33–102.43%, with relative standard deviation less than 4.54% in Cortex phellodendri and from 102.22–111.15% with relative standard deviation less than 4.59% in plasma.  相似文献   

16.
A cross‐linked methacrylate molecularly imprinted polymer (poly‐4‐vinylpyridine‐co‐trimethylolpropane‐trimethacrylate) selective for bisphenol A (BPA) was synthesized, using a fluorinated BPA derivative (4,4′‐(hexafluoroisopropylidene)‐diphenol) as a mimic template, and applied to the analysis of real‐world samples of process and potable waters. The molecularly imprinted polymer also showed a high affinity and selectivity for 17‐β‐estradiol and ethynylestradiol. A method to analyze BPA, 17‐β‐estradiol, and ethynylestradiol at ultratrace levels was thus developed from a screening procedure to monitor endocrine‐disrupting chemicals in water samples. The method consists of the BPA‐selective cleanup by molecularly imprinted SPE using cartridges packed with the polymer developed, its recovery by stir bar sorptive extraction after ad hoc derivatization to obtain the corresponding BPA‐acetate, and its analysis by GC‐time window‐SIM‐MS after online thermal desorption. The method showed good linearity in the working range (R2=0.9969), high repeatability (RSD% <10.1), recoveries always above 90%, and very low LOD (10 pg/L) and LOQ (1 ng/L) and can easily be extended to the determination of 17‐β‐estradiol and ethynylestradiol ultratraces. The method's effectiveness was evaluated by analyzing the real‐world water samples; it enabled preconcentration and detection of BPA at ultratrace levels.  相似文献   

17.
The estrogenic compound diethylstilbestrol (DES) is widely studied because of its potential endocrine disruption effects. The prohibition of the use of diethylstilbestrol as a growth promoter has not been enough to ensure the total disappearance of this compound from environmental matrices. Due to the low levels of DES present in the environment, preconcentration and clean up methods are necessary for its analysis. This paper describes the synthesis and use of a molecularly imprinted polymer (MIP) as sorbent for on-column solid-phase extraction of DES from aqueous samples. The selectivity of the DES-MIP was evaluated towards several selected estrogens such as hexestrol (HEX), estrone (E1), estriol (E3), estradiol (E2) and ethynylestradiol (EE2). HPLC-DAD was used to quantify all analytes at 230-nm wavelength. The method has been successfully applied to the analysis of DES in spiked river and tap water samples, with recoveries of 72% and 83% respectively.  相似文献   

18.
This work describes an on-line molecularly imprinted solid-phase extraction (MISPE) method for spectrophotometric determination of nicotine in urine samples of smokers. This method is based on manganese (VII) to manganese (VI) reduction in an alkaline medium, promoted by nicotine. Two wash solutions (1:4 (v/v) acetonitrile:sodium hydroxide - pH 11.4, and nitric acid - pH 2.5) were employed to circumvent interferences. Aqueous solutions containing nicotine plus different possible concomitants (cotinine, anabasine, norcotinine and caffeine) were tested individually. The analytical calibration curve was prepared in urine samples collected from non-smokers and spiked with nicotine standard from 1.1 to 60 μmol L−1 (r2 > 0.998). The limit of quantification and the analytical frequency were 1.1 μmol L−1 and 11 h−1, respectively. The precision, evaluated using 3, 10 and 30 μmol L−1 nicotine in urine, was 10, 10 and 4% (intra-day precision) and 12, 13 and 5% (inter-day precision), respectively. Accuracy was checked through high performance liquid chromatography and the results did not present significant differences at the 95% confidence level according to the Student's t-test.  相似文献   

19.
An analytical methodology for the analysis of four polar organophophorus pesticides (monocrotophos, mevinphos, phosphamidon, omethoate) in water and soil samples incorporating a molecularly imprinted solid-phase extraction (MISPE) process using a monocrotophos-imprinted polymer was developed. Binding study demonstrated that the polymer showed excellent affinity and high selectivity to monocrotophos. The MISPE procedure including the clean-up step to remove any interferences was optimized. The accuracy and selectivity of the MISPE process developed were verified using a non-imprinted (blank) polymer and a classical ENVI-18 cartridge as the SPE matrix during control experiments. The use of MISPE improved the accuracy and precision of the GC method and lowered the limit of detection. The recoveries of four polar organophosphorus pesticides (OPPs) extracted from 1 L of river water at a 100 ng/L spike level were in the range of 77.5-99.1%. The recoveries of organophosphorus pesticides extracted from a 5-g soil sample at the 100 microg/kg level were in the range of 79.3-93.5%. The limit of detection varied from 10 to 32 ng/L in water and from 12 to 34 microg/kg in soil samples. The molecularly imprinted polymer (MIP) enabled the selective extraction of four organophosphorus pesticides successfully from water and soil samples, demonstrating the potential of molecularly imprinted solid-phase extraction for rapid, selective, and cost-effective sample pretreatment.  相似文献   

20.
Sun H  Qiao F  Liu G  Liang S 《Analytica chimica acta》2008,625(2):154-159
A simple and sensitive method for the simultaneous determination of six fluoroquinolones from serum samples was developed by selective molecularly imprinted matrix solid-phase dispersion (MI-MSPD) coupled with chromatographic separation. By using ethylene glycol dimethacrylate as crosslinker and reformative methanol–water system as reaction medium, the improved water-compatible imprinted polymers were synthesized which show higher affinity to template and its analogues in aqueous environment. The molecularly imprinted polymers (MIPs) were applied as the selective dispersant of matrix solid-phase dispersion (MSPD) could selectively extracted the six fluoroquinolones from serum, while interferences originated from serum matrices were eliminated simultaneously. Good linearity was obtained in a range of 0.05–100 μg mL−1 with the correlation coefficients >0.999. The average recoveries of the six fluoroquinolones at four different spiked levels (0.25–10 μg mL−1) were ranged from 72.2% to 114.1% with the relative standard deviations less than 6.6%. This method is simple and sensitive, and can be used as an alternative tool to the existing HPLC methods for analyzing the residues of fluoroquinolones in biological samples.  相似文献   