首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A high‐throughput and sensitive liquid chromatography–tandem mass spectrometry (LC–MS/MS) method has been developed and validated for the determination of flunarizine in human plasma. Liquid–liquid extraction under acidic conditions was used to extract flunarizine and flunarizine‐d8 from 100 μL human plasma. The mean extraction recovery obtained for flunarizine was 98.85% without compromising the sensitivity of the method. The chromatographic separation was performed on Hypersil Gold C18 (50 × 2.1 mm, 3 μm) column using methanol–10 mm ammonium formate, pH 3.0 (90:10, v/v) as the mobile phase. A tandem mass spectrometer (API‐5500) equipped with an electrospray ionization source in the positive ion mode was used for detection of flunarizine. Multiple reaction monitoring was selected for quantitation using the transitions, m/z 405.2 → 203.2 for flunarizine and m/z 413.1 → 203.2 for flunarizine‐d8. The validated concentration range was established from 0.10 to 100 ng/mL. The accuracy (96.1–103.1%), intra‐batch and inter‐batch precision (CV ≤ 5.2%) were satisfactory and the drug was stable in human plasma under all tested conditions. The method was used to evaluate the pharmacokinetics of 5 and 10 mg flunarizine tablet formulation in 24 healthy subjects. The pharmacokinetic parameters Cmax and AUC were dose‐proportional.  相似文献   

2.
A simple, sensitive, and selective molecularly imprinted solid‐phase extraction and spectrophotometric method has been developed for the clean‐up and preconcentration of indapamide from human urine. Molecularly imprinted polymers were prepared by a non‐covalent imprinting approach using indapamide as a template molecule, 2‐(trifluoromethyl) acrylic acid as a functional monomer, ethylene glycol dimethacrylate as a crosslinker, N,N‐azobisisobutyronitrile as a thermal initiator and acetonitrile as a porogenic solvent. A non‐imprinted polymer was also prepared in the same way, but in the absence of template. Molecularly imprinted polymer and non‐imprinted polymer sorbents were dry‐packed into solid‐phase extraction cartridges. Eluates from cartridges were analyzed using a spectrophotometer for the determination of indapamide by referring to the calibration curve in the range 0.14–1.50 μg/mL. Preconcentration factor, limit of detection, and limit of quantification were 16.30, 0.025 μg/mL, and 0.075 μg/mL, respectively. A relatively high imprinting factor (9.3) was also achieved and recovery values for the indapamide spiked into human urine were in the range of 80.1–81.2%. In addition, relatively low within‐day (0.17–0.42%) and between‐day (1.1–1.4%) precision values were obtained as well. The proposed molecularly imprinted solid‐phase extraction and spectrophotometric method was successfully applied to selective extraction, preconcentration, and determination of indapamide from human urine samples.  相似文献   

3.
A rapid and sensitive reversed‐phase high‐performance liquid chromatographic (RP‐HPLC) method was developed to investigate pharmacokinetics of columbianadin, one of the main bioactive constituents in the roots of Angelica pubescens f. biserrata, in rat plasma after intravenous administration to rats at two doses of 10 and 20 mg/kg. The method involves a plasma clean‐up step using liquid–liquid extraction by diethyl ether, followed by RP‐HPLC separation and detection. Separation of columbianadin was performed on an analytical Diamonsil? ODS C18 column, with a mobile phase of MeOH–H2O (85 : 15, v/v) at a flow‐rate of 1.0 mL/min, and UV detection was set at 325 nm. The retention time of columbianadin and scoparone (internal standard) was 6.7 and 3.5 min, respectively. The calibration curve was linear over the range of 0.2–20.0 μg/mL (r2 = 0.9986) in rat plasma. The lower limits of detection and quantification were 0.05 and 0.1 μg/mL, respectively. The extraction recovery from plasma was in the range of 81.61–89.93%. The intra‐ and inter‐day precisions (relative standard deviation) were between 1.01 and 9.33%, with accuracies ranging from 89.76 to 109.22%. The results indicated that the method established was suitable for the determination and pharmacokinetic study of columbianadin in rat plasma. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

4.
A sensitive ultra high performance liquid chromatography with tandem mass spectrometry method was developed for the simultaneous determination of darunavir, ritonavir and tenofovir in human plasma. Sample preparation involved a simple liquid–liquid extraction using 200 μL of human plasma extracted with methyl tert‐butyl ether for three analytes and internal standard. The separation was accomplished on an Acquity UPLC BEH C18 (50 mm x 2.1 mm, 1.7 μm) analytical column using gradient elution of acetonitrile/methanol (80:20, v/v) and 5.0 mM ammonium acetate containing 0.01% formic acid at a flow rate of 0.4 mL/min. The linearity of the method ranged between 20.0 and 12 000 ng/mL for darunavir, 2.0 and 2280 ng/mL for ritonavir, and 14.0 and 1600 ng/mL for tenofovir using 200 μL of plasma. The method was completely validated for its selectivity, sensitivity, linearity, precision and accuracy, recovery, matrix effect, stability, and dilution integrity. The extraction recoveries were consistent and ranged between 79.91 and 90.04% for all three analytes and internal standard. The method exhibited good intra‐day and inter‐day precision between 1.78 and 6.27%. Finally the method was successfully applied for human pharmacokinetic study in eight healthy male volunteers after the oral administration of 600 mg darunavir along with 100 mg ritonavir and 100 mg tenofovir as boosters.  相似文献   

5.
A specific and rapid liquid chromatography–tandem mass spectrometry method is proposed for the simultaneous determination of metformin (MET), saxagliptin (SAXA) and its active metabolite, 5‐hydroxy saxagliptin (5‐OH SAXA) in human plasma. Sample preparation was accomplished from 50 μL plasma sample by solid‐phase extraction using sodium dodecyl sulfate as an ion‐pair reagent. Reversed‐phase chromatographic resolution of analytes was possible within 3.5 min on ACE 5CN (150 × 4.6 mm, 5 μm) column using acetonitrile and10.0 mm ammonium formate buffer, pH 5.0 (80:20, v /v) as the mobile phase. Triple quadrupole mass spectrometric detection was performed using electrospray ionization in the positive ionization mode. The calibration curves showed good linearity (r 2 ≥ 0.9992) over the established concentration range with limit of quantification of 1.50, 0.10 and 0.20 ng/mL for MET, SAXA and 5‐OH SAXA respectively. The extraction recoveries obtained from spiked plasma samples were highly consistent for MET (75.12–77.84%), SAXA (85.90–87.84%) and 5‐OH SAXA (80.32–82.69%) across quality controls. The validated method was successfully applied to a bioequivalence study with a fixed‐dose formulation consisting of 5 mg SAXA and 500 mg MET in 18 healthy subjects. The reproducibility of the assay was demonstrated by reanalysis of 87 incurred samples.  相似文献   

6.
A selective, sensitive and high‐throughput liquid chromatography–tandem mass spectrometry bioanalytical method has been developed for the estimation of cycloserine in human plasma, employing cytosine as the internal standard. The extraction of the analyte was facilitated by solid‐phase extraction using 100 μL of human plasma. The separation was carried out on a BDS Hypersil C18 (150 × 4.6 mm, 5 μm) column using a mixture of 0.2% formic acid in HPLC‐grade water, methanol and acetonitrile (70:15:15, v/v/v) as mobile phase at a flow rate of 1.0 mL/min. The method was linear over the range of 0.20–20 μg/mL with r2 > 0.99. Complete validation of the method was performed as per US Food and Drug Administration guidelines and the results met acceptance criteria. Applying the present method, the clinical pharmacokinetics of cycloserine following oral administration of 250 mg cycloserine was studied under fasting conditions. Assay reproducibility was also verified by incurred sample reanalysis.  相似文献   

7.
This paper describes a simple, rapid and sensitive liquid chromatography/tandem mass spectrometry assay for the determination of aliskiren in human plasma using nevirapine as an internal standard. Analyte and the internal standard were extracted from 100 μL of human plasma via liquid–liquid extraction using tert‐butyl methyl ether. The chromatographic separation was achieved on a C18 column using a mixture of acetonitrile and 0.1% formic acid (90:10, v/v) as the mobile phase at a flow rate of 0.9 mL/min. The calibration curve obtained was linear (r2 ≥ 0.99) over the concentration range of 0.10–1013 ng/mL. Method validation was performed as per US Food and Drug Administration guidelines and the results met the acceptance criteria. A run time of 2.2 min for each sample made it possible to analyze a greater number of samples in a short time, thus increasing the productivity. The proposed method was found to be applicable to clinical studies. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

8.
An accurate and sensitive LC–MS/MS method for determining thalidomide, 5‐hydroxy thalidomide and 5′‐hydroxy thalidomide in human plasma was developed and validated using umbelliferone as an internal standard. The analytes were extracted from plasma (100 μL) by liquid–liquid extraction with ethyl acetate and then separated on a BETASIL C18 column (4.6 × 150 mm, 5 μm) with mobile phase composed of methanol–water containing 0.1% formic acid (70:30, v/v) in isocratic mode at a flow rate of 0.5 mL/min. The detection was performed using an API triple quadrupole mass spectrometer in atmospheric pressure chemical ionization mode. The precursor‐to‐product ion transitions m/z 259.1 → 186.1 for thalidomide, m/z 273.2 → 161.3 for 5‐hydroxy thalidomide, m/z 273.2 → 146.1 for 5′‐hydroxy thalidomide and m/z 163.1 → 107.1 for umbelliferone (internal standard, IS) were used for quantification. The calibration curves were obtained in the concentrations of 10.0–2000.0 ng/mL for thalidomide, 0.2–50.0 ng/mL for 5‐hydroxy thalidomide and 1.0–200.0 ng/mL for 5′‐hydroxy thalidomide. The method was validated with respect to linear, within‐ and between‐batch precision and accuracy, extraction recovery, matrix effect and stability. Then it was successfully applied to estimate the concentration of thalidomide, 5‐hydroxy thalidomide and 5′‐hydroxy thalidomide in plasma samples collected from Crohn's disease patients after a single oral administration of thalidomide 100 mg.  相似文献   

9.
A simple, rapid, and sensitive method based on dispersive liquid–liquid microextraction combined with HPLC‐UV detection applied for the quantification of chlordiazepoxide in some real samples. The effect of different extraction conditions on the extraction efficiency of the chlordiazepoxide drug was investigated and optimized using central composite design as a conventional efficient tool. Optimum extraction condition values of variables were set as 210 μL chloroform, 1.8 mL methanol, 1.0 min extraction time, 5.0 min centrifugation at 5000 rpm min?1, neutral pH, 7.0% w/v NaCl. The separation was reached in less than 8.0 min using a C18 column using isocratic binary mobile phase (acetonitrile/water (60:40, v/v)) with flow rate of 1.0 mL min?1. The linear response (r2 > 0.998) was achieved in the range of 0.005–10 μg mL?1 with detection limit 0.0005 μg mL?1. The applicability of this method for simultaneous extraction and determination of chlordiazepoxide in four different matrices (water, urine, plasma, and chlordiazepoxide tablet) were investigated using standard addition method. Average recoveries at two spiking levels were over the range of 91.3–102.5% with RSD < 5.0% (n = 3). The obtained results show that dispersive liquid–liquid microextraction combined with HPLC‐UV is a fast and simple method for the determination of chlordiazepoxide in real samples.  相似文献   

10.
Fat‐soluble vitamins play a pivotal role in the progression of atherosclerosis and the development of cardiovascular disease. Therefore, plasma monitoring of their concentrations may be useful in the diagnosis of these disorders as well as in the process of treatment. The study aimed to develop and validate an HPLC–MS/MS method for determination of retinol, α‐tocopherol, 25‐hydroxyvitamin D2 and 25‐hydroxyvitamin D3 in plasma of patients with cardiovascular disease. The analytes were separated on an HPLC Kinetex F5 column via gradient elution with water and methanol, both containing 0.1% (v/v) formic acid. Detection of the analytes was performed on a triple‐quadrupole MS with multiple reaction monitoring via electrospray ionization. The analytes were isolated from plasma samples with liquid–liquid extraction using hexane. Linearity of the analyte calibration curves was confirmed in the ranges 0.02–2 μg/mL for retinol, 0.5–20 μg/mL for α‐tocopherol, 5–100 ng/mL for 25‐hydroxyvitamin D2 and 2–100 ng/mL for 25‐hydroxyvitamin D3. Intra‐ and inter‐assay precision and accuracy of the method were satisfactory. Short‐ and long‐term stabilities of the analytes were determined. The HPLC‐MS/MS method was applied for the determination of the above fat‐soluble vitamin concentrations in patient plasma as potential markers of the cardiovascular disease progression.  相似文献   

11.
A new multiple monolithic fiber solid‐phase microextraction using a polydopamine‐based monolith as the extraction medium is proposed. The monolith was synthesized by facile in situ copolymerization of N‐methacryldopamine and dual cross‐linkers (divinylbenzene/ethylenedimethacrylate) in the presence of N ,N‐dimethylformamide. The effect of the contents of N‐methacryldopamine and porogen in the polymerization mixture on the extraction performance was investigated thoroughly. A series of characterization studies was performed to validate the structure and properties of the monolith. The prepared multiple monolithic fibers were used for the extraction of triazine herbicides in environmental water samples. After the optimization of the extraction parameters, a convenient, sensitive, cost‐effective, and environmentally friendly method for the determination of trace triazine herbicides in water samples was developed by coupling multiple monolithic fibers solid‐phase microextraction with high‐performance liquid chromatography and diode array detection. The results indicated that the limits of detection and quantification for the target compounds were 0.031–0.14 and 0.10–0.45 μg/L, respectively. Good precision and reproducibility were obtained with the relative standard deviations below 10%. The developed method was applied to the analysis of the triazine herbicides in different water samples (lake, river, and farmland waters). The recoveries of the method were in the range between 79.6 and 117%.  相似文献   

12.
A simple gas chromatographic method with mass spectrometry detection was developed and validated for the determination of lacosamide in human plasma. Lacosamide and the internal standard, levetiracetam‐d6, were extracted from 200 μL plasma, by a solid‐phase extraction through HF Bond Elut C18 columns, and derivatized using N‐methyl‐Ntert‐butyldimethylsilyltrifluoroacetamide with 1% tert‐butyldimethylsilylchloride in acetonitrile. The limit of quantification was found to be 0.20 μg/mL and the assay was linear up to 20.0 μg/mL with correlation coefficient ≥0.994. The intra‐ and interday precision values were <4.1% in terms of relative standard deviation (%) and the values of intra‐ and interday accuracy were found to be within –7.2 and 5.3% in terms of relative error (%). Absolute recovery of the method for lacosamide was determined at three concentration levels and ranged from 92.5 to 97.6%. The developed method uses small volumes of plasma and proved to be simple, rapid, and sensitive for the determination of lacosamide in plasma. This method can be used in routine every day analysis of plasma samples obtained from patients who follow respective antiepileptic treatment and for the investigation of clinical and forensic cases where lacosamide is involved.  相似文献   

13.
A sensitive and selective liquid chromatography–tandem mass spectrometry (LC–MS/MS) method is described for the simultaneous determination of silodosin (SLD) and its active metabolite silodosin β‐d ‐glucuronide (KMD‐3213G) in human plasma. Liquid–liquid extraction of plasma samples was carried out with ethyl acetate and methyl tert‐butyl ether solvent mixture using deuterated analogs as internal standards. The extraction recoveries of SLD and KMD‐3213G were in the ranges 90.8–93.4 and 87.6–89.9%, respectively. The extracts were analyzed on a Symmetry C18 (50 × 4.6 mm, 5 μm) column under gradient conditions using 10 mm ammonium formate in water and methanol–acetonitrile (40:60, v/v), within 6.0 min. For MS/MS measurements, ionization of the analytes was carried out in the positive ionization mode and the transitions monitored were m/z 496.1 → 261.2 for SLD and m/z 670.2 → 494.1 for KMD‐3213G. The method showed good linearity, accuracy, precision and stability in the range 0.10–80.0 ng/mL for SLD and KMD‐3213G. The IS‐normalized matrix factors obtained were highly consistent, ranging from 0.962 to 1.023 for both analytes. The method was used to support a bioequivalence study of SLD and its metabolite in healthy volunteers after oral administration of 8 mg silodosin capsules.  相似文献   

14.
A sensitive and specific liquid chromatography tandem mass spectrometric method was developed and validated for the simultaneous determination of rosuvastatin (ROS) and N‐desmethyl rosuvastatin (NOR‐ROS) in human plasma using deuterium‐labeled internal standards. The plasma samples were prepared using liquid–liquid extraction with diethyl ether. Chromatographic separation was accomplished on an Xterra MS C18 column. The mobile phase consisted of a gradient mixture of 15 µmol/L ammonium acetate in water and in methanol, maintained at a flow rate of 0.4 mL/min. Mass spectrometric detection was carried out in negative electrospray ionization mode and monitored by quantification and qualification transitions for each analyte. Using 300 μL plasma samples, the lower limits of quantification of ROS and NOR‐ROS were 0.05 and 0.02 µg/L respectively. The linearity of ROS and NOR‐ROS ranged from 0.05 to 42 and 0.02 to 14 µg/L respectively. The relative standard deviations of ROS and NOR‐ROS were <13 and 9%, respectively, while the deviations from expected values were within ?4.7–9.8 and ?5.2–4.6%, respectively. The present method offered high sensitivity and was successfully applied to a 24 h pharmacokinetic study of ROS and NOR‐ROS in healthy subjects receiving a single dose of 10 mg ROS. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

15.
An original method based on liquid chromatography with single quadrupole electrospray ionization mass spectrometry was developed for the determination of sunitinib in human plasma. The quantitation limit of the method at 0.10 ng/mL is comparable to that of tandem mass spectrometry assays. The handling of all solutions containing sunitinib was performed under low‐intensity red light to avoid the isomerization of sunitinib and enable quantitation using a single peak. Liquid–liquid extraction with a mixture of n‐hexane/isopropanol (90:10 v/v) allowed recoveries at the level of 70%. Measurements were performed using a Zorbax SB‐C18 column (3.0 mm × 150 mm, 3.5 μm) and isocratic elution with (A) 0.1% aqueous formic acid and (B) acetonitrile/methanol (80:20 v/v) in an A/B ratio of 55:45 at 35°C. Under these conditions, sunitinib is eluted at 3.8 min in 6 min of the total run time. The linearity of the calibration curve ranges from 0.10 to 150 ng/mL. The baseline separation of sunitinib and its primary metabolite, Ndes‐ethyl sunitinib (SU12662), as well as sharp peak shapes, suggest a possibility of extending the applied methodology to the quantitative determination of both compounds. Isotopically labeled sunitinib was used as the internal standard. All required validation tests met the acceptance criteria and proved the method's reliability and robustness. The method may be conveniently applied to study the pharmacokinetics of sunitinib in humans.  相似文献   

16.
A novel and sensitive dispersive liquid–liquid microextraction method based on the solidification of the floating organic drop combined with high‐performance liquid chromatography and ultraviolet detection was used for the determination of atorvastatine in blood serum samples. The chromatographic separation of atorvastatin was carried out using methanol as the mobile phase organic modifier. Various parameters affecting the extraction efficiency were optimized, such as the kind and volume of extraction solvent (1‐undecanol) and disperser solvent (acetonitrile), pH, and the extraction time. The calibration curve was linear in the range of 0.2–6000 μg/L of atorvastatin (r2 = 0.995) with a limit of detection of 0.07 μg/L. The relative standard deviation for 100 μg/L of atorvastatin in human plasma was 8.4% (n = 4). The recoveries of plasma samples spiked with atorvastatin were in the range of 98.8–113.8%. The obtained results showed that the proposed method is fast, simple, and reliable for the determination of very low concentrations of atorvastatin in human plasma samples.  相似文献   

17.
A simple and sensitive liquid chromatography–electrospray ionization–tandem mass spectrometry (LC‐ESI‐MS/MS) technique was developed and validated for the determination of sibutramine and its N‐desmethyl metabolites (M1 and M2) in human plasma. After extraction with methyl t‐butyl ether, chromatographic separation of analytes in human plasma was performed using a reverse‐phase Luna C18 column with a mobile phase of acetonitrile–10 mm ammonium formate buffer (50:50, v/v) and quantified by ESI‐MS/MS detection in positive ion mode. The flow rate of the mobile phase was 200 μL/min and the retention times of sibutramine, M1, M2 and internal standard (chlorpheniramine) were 1.5, 1.4, 1.3 and 0.9 min, respectively. The calibration curves were linear over the range 0.05–20 ng/mL, for sibutramine, M1 and M2. The lower limit of quantification was 0.05 ng/mL using 500 μL of human plasma. The mean accuracy and the precision in the intra‐ and inter‐day validation for sibutramine, M1 and M2 were acceptable. This LC‐MS/MS method showed improved sensitivity and a short run time for the quantification of sibutramine and its two active metabolites in plasma. The validated method was successfully applied to a pharmacokinetic study in human. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

18.
A method was developed that applies hydrophilic interaction liquid chromatography with tandem mass spectrometry in the multiple reaction monitoring mode to separate and accurately quantify trimethylamine and trimethylamine N‐oxide in a single chromatographic run. This was achieved by converting trimethylamine to ethyl betaine, which is less volatile and hence results in greatly improved quantitation. Ethyl betaine also gives a similar response to trimethylamine N‐oxide using positive‐ion electrospray ionization mass spectrometry. It is readily separated from trimethylamine N‐oxide by hydrophilic liquid chromatography in a 5 min run and with improved peak shape compared to underivatized trimethylamine. Validation of the method yielded a limit of detection (S/N ≥ 3) of 0.5 ng/mL for trimethylamine and 0.25 ng/mL for trimethylamine N‐oxide. Method accuracies of 91.4–105.3% with precisions of 0.4–5.5% were obtained for standard mixtures over the range of 2.5–500 ng/mL. Recoveries measured for the extraction of trimethylamine and trimethylamine N‐oxide spikes into mouse plasma were both >90%. The method, which simultaneously measures trimethylamine and trimethylamine N‐oxide, was successfully applied to mouse plasma samples and could be adapted for use with other biological fluids.  相似文献   

19.
Yonkenafil is a promising drug for treatment of male erectile dysfunction. Previous studies showed that the piperazine‐N,N’‐deethylation metabolite, piperazine‐N‐deethylation metabolite, and piperazine‐N‐deethylation‐N,N’‐deethylation metabolite were the major metabolites of yonkenafil after extensive metabolism. We developed a sensitive and selective method for the simultaneous quantification of yonkenafil and its major metabolites using high‐throughput liquid chromatography with tandem mass spectrometry. Analytes and internal standard were extracted from a small quantity of plasma (50 μL) using liquid–liquid extraction with diethyl ether/dichloromethane (60:40, v/v), and the baseline separation was achieved on Zorbax SB‐C18 column using ammonia/water/methanol (0.2:20:80, v/v/v) as the mobile phase. The assay was performed with an electrospray positive ionization mass spectrometry through the multiple‐reaction monitoring mode within 2 min. Calibration curve of the method was linear within the range of 1.00–1000 ng/mL for all the analytes with the intra‐ and interday precisions of 4.0–5.2 and 4.0–5.3% for yonkenafil, 3.1–4.9 and 3.1–5.2% for the piperazine‐N,N’‐deethylation metabolite, 4.8–6.8 and 4.8–7.3% for the piperazine‐N‐deethylation metabolite, and 2.9–6.1 and 5.4–6.3% for the piperazine‐N‐deethylation‐N,N’‐deethylation metabolite, respectively. The recoveries were above 90% with low matrix effects. The validated assay was successfully applied to support a preclinical pharmacokinetic study in six rats using a single oral dose of yonkenafil (8 mg/kg).  相似文献   

20.
Linezolid is an antimicrobial agent for the treatment of multiresistant Gram‐positive infections. A practical high‐performance liquid chromatography method was developed for the determination of linezolid in human plasma and saliva. Linezolid and an internal standard (o‐ethoxybenzamide) were extracted from plasma and saliva with ethyl acetate and analyzed on a Capcell Pak C18 MG column with UV detection at 254 nm. The calibration curve was linear through the range 0.5–50 µg/mL using a 200 μL sample volume. The intra‐ and interday precisions were all <6.44% for plasma and 5.60% for saliva. The accuracies ranged from 98.8 to 110% for both matrices. The mean recoveries of linezolid were 80.8% for plasma and 79.0% for saliva. This method was used to determine the plasma and saliva concentrations of linezolid in healthy volunteers who were orally administered a 600 mg dose of linezolid. Our liquid–liquid extraction procedure is easy and requires a small volume of plasma or saliva (200 μL). This small volume can be advantageous in clinical pharmacokinetic studies, especially if children participate. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号