首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 11 毫秒
1.
A novel, rapid and sensitive isocratic liquid chromatography/tandem mass spectrometry (LC/MS/MS) method was developed for quantification of docetaxel in human plasma with paclitaxel as internal standard. The high sensitivity and specificity of MS/MS detection enabled the use of a small volume of plasma (0.05 mL) and a simple liquid-liquid extraction procedure. Furthermore, a very short run-time (3 min) fulfilled the need for monitoring plasma levels of docetaxel from large-scale clinical studies. The calibration curve for docetaxel was linear over the range 5-1000 ng/mL with coefficients of correlation >0.999 using only 0.05 mL plasma. The intra- and inter-day precisions (CV) of analysis were <7%, and accuracy ranged from 96 to 110%. The applicability of the method was demonstrated in a pharmacokinetic study of a 1-h infusion of docetaxel with dosages of 75 mg/m(2). Possible conjugated metabolites of docetaxel were not detected in patients' samples.  相似文献   

2.
A simple and highly sensitive LC/MS method was developed for the simultaneous determination of six ionophores--lasalocid, monensin, laidlomycin, maduramycin, salinomycin, and narasin--in feed. The procedure involved extraction of 1 g of feed with 4 mL of methanol-water (9 + 1, v/v) by shaking on a platform shaker for 45 min. After centrifugation, the extracts were diluted with methanol-water (75 + 25, v/v) and analyzed without any cleanup. The analysis was performed on a Betasil C18 column (150 x 4.6 mm id, 5 pm particle size) connected to an LC/MS system operated in the atmospheric pressure chemical ionization (APCI) mode. We believe this to be the first method that uses the APCI mode for the analysis of ionophores. The mobile phase consisted of 50 mM ammonium acetate as solvent A and acetonitrile-methanol (7 + 3, v/v) as solvent B in a gradient run. Excellent recoveries of 81-120% were found for all compounds at fortification levels of 1-200 microg/g, with RSD < or =15% (except 17% for maduramycin at 2 and 5 microg/g, and 16% for salinomycin at 1 microg/g). At 0.5 microg/g, recoveries of 87-119% were obtained, with RSD < or =20%. However, recovery of lasalocid was 133% and salinomycin 79% in sow and horse feed, respectively. Average RSD values of lasalocid and salinomycin were 22 and 21%, respectively. Finally, proficiency test samples analyzed with the method demonstrated favorable agreement with the certified values.  相似文献   

3.
4.
Aromatic amines are one of the sources of carcinogenicity in cigarette and tobacco smoke. Accurate quantification of these chemicals is needed to assess public health risk. A new validated rapid, sensitive and analyte specific liquid chromatography/electrospray ionization tandem mass spectrometric (LC/MS/MS) method has been developed for the simultaneous determination of six aromatic amines in mainstream cigarette smoke using research reference cigarette 2R4F. Three popular Indian brand cigarettes were also analyzed using the same procedure. The limit of detection of this method ranged from 0.04 to 0.59 ng/cig using an injection volume of 7 μl. The identification of each amine was established by chromatographic retention times, analyte specific fragmentation pattern and relative peak area ratios of two product/precursor ion pairs. The method showed excellent reproducibility and was also rapid, selective and robust for aromatic amine determination from cigarette smoke.  相似文献   

5.
Two different isotope-dilution liquid chromatography/tandem mass spectrometry (LC/MS/MS) methods for the quantitative determination of folic acid (FA) in multivitamin/multielement tablets are reported. These methods represent distinct improvements in terms of speed and specificity over most existing microbiological and chromatographic methods for the determination of FA in dietary supplements. The first method utilizes an aqueous/organic-based extraction solvent combined with positive-ion mode LC/MS/MS detection of protonated [M + H]+ FA molecules and the second method utilizes a pure aqueous-based extraction solvent combined with negative-ion mode LC/MS/MS detection of deprotonated [M - H]- FA molecules. The LC/MS/MS methods exhibit comparable linear dynamic ranges (> or =3 orders of magnitude), limits of detection (0.02 ng on-column) and limits of quantification (0.06 ng on-column) for FA. Two methods employing different extraction and different MS detection modes were developed to allow method cross-validation. Successful validation of each measurement procedure supports the use of either method for the certification of FA levels in dietary supplements. The accuracy and precision of each measurement procedure were evaluated by applying each method to the quantitative determination of FA in a NIST standard reference material (NIST SRM 3280 multivitamin/multielement tablets). The FA measurement accuracy for both methods was > or =95% (based on the manufacturer's assessment of the FA level in SRM 3280) with corresponding measurement precision values (% RSD) of approximately 1%.  相似文献   

6.
Artemisinin is a widely used antimalarial drug. To evaluate the pharmacokinetics of artemisinin in rats, a sensitive and specific liquid chromatography/tandem mass spectrometric (LC/MS/MS) method was developed and validated for the determination of artemisinin in rat plasma. For detection, a Sciex API 4000 LC/MS/MS instrument with an electrospray ionization (ESI) TurboIonSpray inlet in the positive ion multiple reaction monitoring (MRM) mode was used to monitor precursor ([M+NH4]+) --> product ions of m/z 300.4 --> 209.4 for artemisinin and m/z 316.4 --> 163.4 for artemether, the internal standard (IS). The plasma samples were pretreated by a simple liquid-liquid extraction with ether. The standard curve was linear (r > 0.99) over the artemisinin concentration range of 1.0-200.0 ng/mL in plasma. The method had a lower limit of quantification of 1.0 ng/mL for artemisinin in 100 microL of plasma, which offered a satisfactory sensitivity for the determination of artemisinin. The intra- and inter-day precisions were measured to be within +/-5.3% and accuracy between -2.6% and 1.2% for all quality control samples, lower limit of quantification and upper limit of quantification samples. The extraction recoveries of artemisinin and the IS were 95.4 +/- 4.5% and 92.8 +/- 3.9%, respectively. This present method was successfully applied to the characterization of the pharmacokinetic profile of artemisinin in rats after oral administration.  相似文献   

7.
Isoniazid and ethambutol are commonly used in various combination treatments for tuberculosis, and for this reason a rapid and sensitive liquid chromatography/tandem mass spectrometry (LC/MS/MS) method was developed and validated for simultaneous quantification of these two drugs in human plasma. After a simple protein precipitation using methanol, the analytes and the internal standard metformin were chromatographed on a C18 column and detected by MS/MS. An atmospheric pressure chemical ionization interface was chosen to reduce ion suppression from sample matrix components and provide high sensitivity. The LC retention times for isoniazid and ethambutol were 2.46 and 2.27 min, respectively. The method was linear in the concentration range of 10.0-5000 ng/mL for each analyte using 100 microL plasma. The intra- and inter-day precisions, expressed as the relative standard deviation (RSD), were less than 5.7 and 6.4%, determined from QC samples for isoniazid and ethambutol, and the accuracies were within +/-2.1% and +/-4.5% in terms of relative error, respectively. The method was successfully employed in a pharmacokinetic study after oral administration of a multicomponent formulation containing 150 mg isoniazid, 500 mg ethambutol, 150 mg rifampicin and 250 mg pyrazinamide.  相似文献   

8.
An HILIC-PI APCI MS/MS method is developed for the determination of seven biogenic amines (cadaverine, histamine, putrescine, spermidine, spermine, tryptamine and tyramine) in cheese. Their presence and relative amounts give useful information about freshness, level of maturing, quality of storage and cheese typicization. The major drawback in the analysis is represented by the relevant matrix effect and the general unbalanced concentrations of the different amines in cheese. The method proposed represents an improvement with respect to an HPLC-MS/MS method already developed in this laboratory. The new method permits better sensitivities it makes use of a Waters Atlantis HILIC (150.0 mm x 2.1 mm i.d., 3 microm) stationary phase and of a mobile phase of acetonitrile and ammonium formate 50.0 mM in ultrapure water brought to pH 4.00 for formic acid, flowing under gradient conditions. The chromatographic system is interfaced with a 3200QTrap LC-MS/MS system (Applied Biosystem, Foster City, CA, USA) by a Turbo V interface equipped with Heated Nebuliser (APCI) and Turbo Ion Spray (TIS) probes. LOQ values lower than 10 microg L(-1) are obtained. The method is applied in the analysis of Castelmagno cheese.  相似文献   

9.
A novel multi-analyte method for the simultaneous determination of 46 compounds of environmental concern, most of them belonging to the category of persistent organic pollutants, was developed using high-performance liquid chromatography and the results were compared to those obtained by gas chromatography. This study was performed in perspective of a cumulative exposure assessment of substances of health concern in environments where high levels, relatively to airborne particulate matter, can be found. The target compounds included polychlorinated biphenyls, brominated flame–retardants and derivatives of polycyclic aromatic hydrocarbons.

The multi-analyte method was evaluated in air particulate matter in terms of reproducibility, linearity, recovery, limits of detection and quantification and matrix effect. The recovery was above 70% for all the analytes, whereas limits of quantification ranged between 23 and 390 pg?m?3 in liquid chromatography and less than ten times in gas chromatography–mass spectrometry.

Matrix effect was generally negligible for both the techniques, except the case of the detection of oxygenated derivatives of polycyclic aromatic hydrocarbons by gas chromatography.

In order to demonstrate the efficacy and to assess the method performances (accuracy and precision), both the techniques were applied to standard reference materials, and the results were compared, discussing their advantages and disadvantages.

The method was finally applied to a real sample of indoor airborne particulate matter with aerodynamic diameter ≤4 μm (PM4).

We demonstrated that liquid chromatography was the only technique able to analyse the 46 compounds, including thermally degradable ones, with a single chromatographic run without derivatisation steps. On the other hand, gas chromatography still presents higher sensitivity for the detection of some of the investigated compounds. This study can be considered only explorative and further improvements can be expected with new-generation LC-MS instruments (10–100 times more sensitive).  相似文献   

10.
A method based on solid-phase extraction (SPE) coupled to high-performance liquid chromatography (HPLC) with positive ion electrospray ionization tandem mass spectrometry (ESI-MS/MS) detection was developed for the simultaneous determination of lamivudine (3TC) and zidovudine (AZT) in human serum, using didanosine (ddI) as internal standard. The acquisition was performed in multiple reaction monitoring (MRM) mode, monitoring the transitions m/z 230.0 --> 111.8 for 3TC, m/z 268.1 --> 126.8 for AZT, and m/z 237.2 --> 136.8 for ddI. The limits of detection and quantitation were 3 and 10 ng/mL for 3TC, and 5 and 15 ng/mL for AZT. The method was linear in the studied ranges (10-1500 ng/mL for 3TC and 15-3000 ng/mL for AZT), with r(2) > 0.99 for each drug, and the run time was 4 min. The intra-assay precisions (%) were in the ranges 1.9-8.7 (3TC) and 2.2-8.9 (AZT), the inter-assay precisions were in the ranges 2.6-9.0 (3TC) and 4.2-8.1 (AZT), and the intra- and inter-assay accuracies were >97% for both drugs. The absolute recoveries were 95-99% for 3TC (45, 600 and 1200 ng/mL) and 104-112% for AZT (45, 1000 and 2400 ng/mL). The analytical method was applied to a bioequivalence study in which 24 healthy adult volunteers received single oral doses of the reference formulation and two test combined AZT/3TC tablets, in an open, three-period, balanced, randomized, crossover protocol. Based on the 90% confidence interval of the individual ratios (test formulation/reference formulation) for C(max) (peak serum concentration) and AUC(0-inf) (extrapolated area under the serum concentration vs. time curve from time zero to infinity), it was concluded that the two test formulations are bioequivalent to the reference formulation with respect to the rate and extent of absorption of both 3TC and AZT.  相似文献   

11.
A sensitive, rapid and specific quantitative liquid chromatography/tandem mass spectrometry (LC/MS/MS) method was developed and validated for the determination of apomorphine (APO) in canine plasma. The analytes were prepared using one-step liquid-liquid extraction, and analyzed on a Waters Symmetry C(18) column interfaced with triple quadrupole tandem mass spectrometer. A mixture of methanol/0.1% formic acid in water (70: 30, v/v) was employed as the isocratic mobile phase. Positive electrospray ionization was utilized as the ionization source. The analyte and clenbuterol (internal standard) were both detected using multiple reaction monitoring (MRM) mode. The limit of detection (LOD) obtained was 0.03 ng/mL. The assay was linear over the concentration range of 0.1-100 ng/mL, and provided good precision (RSD) and good accuracy (RE). The analyte was stable by using antioxidants throughout the whole study. The experimental results show that LC/MS/MS is a rapid and sensitive method to analyze APO in plasma. Finally, the proposed method was successfully applied to a pharmacokinetic study of APO after intranasal administration of 0.5 mg apomorphine to 10 healthy beagle dogs.  相似文献   

12.
Ye S  Yao Z  Na G  Wang J  Ma D 《Journal of separation science》2007,30(15):2360-2369
This paper describes a rapid method for the determination of 14 kinds of sulfonamides (SAs) in wastewater using SPE, and LC-MS/MS with positive ESI (ESI(+)) and selected reaction monitoring (SRM) mode. The SPE was performed on an Oasis hydrophilic-lipophilic-balanced (HLB) cartridge. Chromatographic separation on a C18 column was achieved using a binary eluent containing methanol and water with 0.2% formic acid. Typical recoveries of the analytes ranged from 22.3 to 87.0% at a fortification level of 100 ng/L. The LODs in wastewater except sulfathiazole (3 ng/L) could be detected and quantified at levels as low as 1 ng/L. Finally, the method was applied to water from the municipal outlet and the aquaculture wastewater effluent. Sulfamethazine (SM(2)), sulfamethoxypyridazine (SMP), and sulfamethoxazole (SMZ) were most frequently found in wastewater in a concentration range between 1.2 and 31.7 ng/L.  相似文献   

13.
An HPLC/MS/MS method for the determination of arbidol in human plasma was developed. Arbidol and internal standard (loratadine) were extracted from alkaline plasma with tert-butyl methyl ether and analyzed on a Zorbax SB C18 column (30 x 2.1 mm id, 3.5 microm particle size). The detection was by monitoring arbidol at m/z 479.1 --> 434.1 and the internal standard at m/z 383.2 --> 337.2. The method was validated according to U.S. Food and Drug Administration guidelines. The calibration curve was linear over the range of 0.5-500 ng/mL using a 100 microL sample volume. The intraday and interday precisions were less than 6.5%, and acceptable values were obtained for accuracy, recovery, and sensitivity. The developed method was selective, simple, sensitive, and easily applicable.  相似文献   

14.
Shi Y  Sun C  Gao B  Sun A 《Journal of chromatography. A》2011,1218(42):7655-7662
A method for simultaneous determination of eight adulterants including two appetite suppressants, two energy expenditure-enhancing drugs, one diuretic and three cathartics in slimming functional foods by high performance liquid chromatography with electrospray ionization-tandem mass spectrometry (HPLC-ESI-MS/MS) was established. After samples were ultrasonically extracted with 70% (v/v) methanol aqueous solution and centrifuged, the components of ephedrine, norpseudoephedrine, fenfluramine, sibutramine, clopamide, emodin, rhein, and chrysophanol in sample solution were separated by a Hypersil Gold column (2.1 mm × 150 mm, 5 μm) using a programmed gradient elution. A mobile phase consisting of 0.02% (v/v) formic acid-ammonium formate buffer solution (pH=3.50) and methanol was used for elution with a flow rate set at 250 μL/min and column temperature of 25 °C. Qualitative determination was based on characteristic ion pairs and retention time of the targeted compounds using SRM (selective reaction monitoring) mode. Clenbuterol and ibuprofen were internal standards in positive and negative ionization mode, respectively. The internal standard curves were used for quantification measurement. The average recoveries of three different concentrations were from 80.2% to 94.5%. The limits of detection (LODs) were from 0.03 to 0.66 mg/kg (except chrysophanol 1.6 mg/kg). The linear dynamic range covered from 1 to 500 μg/L (except chrysophanol 50-5000 μg/L) for the twelve samples analyzed. Adulterants in four different kinds of slimming functional foods were determined by this developed method, and satisfactory results were obtained. These experimental results showed that, adulteration of sibutramine or/and fenfluramine were the major adulterating components with contents varying from 6.1 to 1.3×10(3) mg/kg and 1.9 to 9.7×10(3) mg/kg, respectively. In addition, three cathartic compounds were detected in six of those tested samples, and ephedrine, norpseudoephedrine and clopamide were not detected in all samples.  相似文献   

15.
A simple, sensitive and rapid ultra-performance liquid chromatography/positive electrospray ionization tandem mass spectrometry (UPLC/ESI-MS/MS) method has been developed and validated for the determination of lercanidipine in human plasma. Lercanidipine and the internal standard, nicardipine, were extracted from plasma by liquid-liquid extraction using tert-butyl methyl ether as the extraction solvent. UPLC analysis was performed isocratically on an AcQuity UPLC BEH C18 analytical column (2.1 x 50.0 mm i.d., particle size 1.7 microm). The mobile phase consisted of 70% acetonitrile in water containing 0.2% v/v formic acid and pumped at a flow rate of 0.30 mL/min. ESI in positive ion mode, with multiple reaction monitoring (MRM), was chosen for the detection of the analytes. The assay was linear over a concentration range of 0.05-30 ng/mL for lercanidipine with a limit of quantitation of 0.05 ng/mL. Quality control samples (0.05, 0.15, 15 and 25 ng/mL) in five replicates from five of analytical runs demonstrated intra-assay precision (% CV < or =7.3%), inter-assay precision (% CV < or =6.1%) and an overall accuracy (% relative error) of less than 6.2%. A run time of less than 1.0 min for each sample made it possible to analyze a large number of human plasma samples per day. The method can be used to quantify lercanidipine in human plasma covering a variety of pharmacokinetic or bioequivalence studies.  相似文献   

16.
Salvianolic acid A (SAA), a major effective constituent of Salvia miltiorrhizas, is widely used in traditional Chinese medicine. A sensitive rapid analytical method was established and validated for SAA in rat plasma, which was further applied to assess the pharmacokinetics of SAA in rats receiving a single oral dose of SAA. The method used liquid chromatography tandem mass spectrometry in multiple reaction monitoring mode with chloramphenicol as the internal standard. A simple liquid-liquid extraction based on ethyl acetate was employed. The combination of a simple sample cleanup and short chromatographic run time (3 min) increased the throughput of the method substantially. The method was validated over the range 1.4-1000 ng/mL with a correlation coefficient >0.99. The lower limit of quantification was 1.4 ng/mL for SAA in plasma. Intra- and inter-day accuracies for SAA were 95-113 and 98-107%, and the inter-day precision was less than 12%. This method is more sensitive and faster than previous methods. After a single oral dose of 100 mg/kg of SAA, the mean peak plasma concentration (Cmax) of SAA was 318 ng/mL at 0.5 h, the area under the plasma concentration-time curve (AUC0-12 h) was 698 +/- 129 ng.h/mL, and the elimination half-life (T1/2) was 3.29 h.  相似文献   

17.
Hydrophilic interaction liquid chromatography (HILIC) interfaced with atmospheric pressure ionization (API) sources and a tandem mass spectrometer (MS/MS) was developed for the simultaneous determination of dasatinib, imatinib and nilotinib in mouse plasma samples. The retention profiles of all analytes on several silica stationary phases under HILIC conditions were explored. The influences of experimental factors such as the compositions of mobile phases on the chromatographic performance and the ionization efficiency of all analytes in positive ion mode were investigated. The applicability of the proposed HILIC/MS/MS approach following a protein precipitation procedure for the quantitative determination of dasatinib, imatinib and nilotinib at low nano‐mole levels was examined with respect to assay specificity and linearity. The analytical results obtained by various HILIC/MS/MS approaches were found to be in good agreement with those obtained by reversed‐phase liquid chromatography/tandem mass spectrometry (RPLC/MS/MS) methods in terms of assay sample throughputs, sensitivity and accuracy. Furthermore, the potential of matrix ionization suppression on the proposed HILIC/MS/MS systems was investigated using the post‐column infusion technique. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

18.
This work presents two liquid chromatography/tandem mass spectrometry (LC/MS/MS) acquisition modes: multiple reaction monitoring (MRM) and neutral loss scan (NL), for the analysis of 28 compounds in a mixture. This mixture includes 21 compounds related to the metabolism of three amino acids: tyrosine, tryptophan and glutamic acid, two pterins and five deuterated compounds used as internal standards. The identification of compounds is achieved using the retention times (RT) and the characteristic fragmentations of ionized compounds. The acquisition modes used for the detection of characteristic ions turned out to be complementary: the identification of expected compounds only is feasible by MRM while expected and unexpected compounds are detected by NL. In the first part of this work, the fragmentations characterizing each molecule of interest are described. These fragmentations are used in the second part for the detection by MRM and NL of selected compounds in mixture with and without biological fluids. Any preliminary extraction precedes the analysis of compounds in biological fluids.  相似文献   

19.
Mass spectrometry of ochratoxin A (OTA) and B (OTB) under electrospray ionization (ESI) and atmospheric pressure chemical ionization (APCI) was studied. ESI offers higher sensitivities and less fragmentation than APCI. A sensitive LC/MS/MS method for the determination of ochratoxin A (OTA) in human plasma samples was developed. The absolute minimum detection limit was around 10-20 pg per injection, corresponding to 0.5 ppb in an injection equivalent to 20-40microg of human plasma. Ochratoxin B (OTB) was used as an internal standard and its absence in real-life samples was carefully checked before samples were spiked with the internal standard. It was found that these two ochratoxins are susceptible to sodium adduct formation. Fragment ions from the [M + H](+) and [M + Na](+) ions of both OTA and OTB were monitored in the multiple reaction monitoring mode. Three quantitative approaches, standard addition method, internal standard method (using ochratoxin B as an internal standard) and external standard method, were compared in the analysis of human blood plasma. Results from the mass spectrometric method were comparable to those from a conventional LC/fluorescence method. The LC/MS/MS method was also applied to the analysis of contaminated coffee samples.  相似文献   

20.
Findings of illegal hormone preparations such as syringes, bottles, cocktails, and so on, are an important information source for the nature of the current abuse of anabolic steroids and related compounds as growth-promoting agents in cattle. A new screening method for steroids in cocktails is presented based on liquid chromatography (LC) with diode-array UV-absorbance detection and electrospray ionization time-of-flight mass spectrometry (ESI-TOFMS). Accurate mass measurements were performed at a mass resolution of 4000 using continuous introduction of a lock mass through a second (electro)sprayer. Similar experiments were carried out using dual-sprayer quadrupole time-of-flight mass spectrometry (ESI-QTOFMS/MS) at a mass resolution of 10 000 with data-dependent MS/MS acquisition; i.e. beyond an intensity threshold for the [M + H](+) ions, MS/MS spectra were automatically acquired at three different collision energies. Elemental compositions were calculated for precursor and product ions and it is shown that the combined information from LC retention behavior, UV spectra, elemental compositions, and accurate mass MS/MS spectra yield a fast impression of the steroids present in the complex mixture. Using a new software tool for structure elucidation of MS/MS spectra, an additional non-steroidal additive was identified as well.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏