首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Cloud point extraction (CPE) was applied as a preconcentration step prior to graphite furnace atomic absorption spectrometry (GFAAS) determination of manganese(II) and iron(III) in water samples. After complexation with 1-phenyl-3-methyl-4-benzoyl-5-pyrazolone (PMBP), the analytes could be quantitatively extracted to the phase rich in the surfactant p-octylpolyethyleneglycolphenylether (Triton X-100) and be concentrated, then determined by GFAAS. The parameters affecting the extraction efficiency, such as solution pH, concentration of PMBP and Triton X-100, equilibration temperature and time, were investigated in detail. Under the optimum conditions, preconcentration of 10 ml of sample solution permitted the detection of 0.02 ng ml(-1) of Mn(II) and 0.08 ng ml(-1) of Fe(III) with enrichment factors of 31 and 25 for Mn(II) and Fe(III), respectively. The proposed method was applied to determination of trace manganese(II) and iron(III) in water samples with satisfactory results.  相似文献   

2.
In this paper, flame atomic absorption spectrometry was used for the determination of silver in various materials. The proposed preconcentration method is based on the continuous precipitation of silver as p-dimethylaminobenzilidene-rhodanine (PDBR) complex and dissolution of the precipitate with potassium cyanide. EDTA was added to the sample solution to mask large concentrations of Fe(III), Ni(II), Cu(II), Zn(II), Pb(II), Co(II) and Al(III). An enhancement factor of 20 was obtained for a preconcentration time of 3 min, resulting in a sampling frequency of 16 h(-1). The detection limit (3sigma) in the sample solution was 5 ngml(-1). The relative standard deviation at 30 ngml(-1) level was 4.7%. Analytical results obtained for alloy, biological reference material and ore samples analyzed were in good agreement with the certified values and comparable to those obtained with other techniques.  相似文献   

3.
建立了微晶蒽分离富集环境水样中痕量Co(II)的方法。在pH3.0条件下,1-亚硝基-2-萘酚与Co(II)形成红棕色螯合物被微晶蒽定量吸附,能使Co(II)与Pb(II)、Ni(II)、Mn(II)、Cu(II)、Cd(II)、Zn(II)、Fe(III)、Cr(III)、Al(III)等常见离子分离。本法富集倍数达100倍,检出限为0.14μg/L,回收率97.5%~105%,已应用于不同水样中Co(II)的测定。  相似文献   

4.
A separation/preconcentration procedure based on the coprecipitation of Pb(II), Fe(III), Co(II), Cr(III) and Zn(II) ions with copper(II)-N-benzoyl-N-phenyl-hydroxylamine complex (Cu-BPHA) has been developed. The analytical variables including pH, amount of BPHA, amount of copper(II) as carrier element, and sample volume were investigated for the quantitative recoveries of the elements. No interfering effects were observed from the concomitant ions when present in real samples. The recoveries of the analyte ions were in the range of 95–100%. The detection limits (3 s) for Pb(II), Co(II), Fe(III), Cr(III) and Zn(II) ions were found to be 2.3, 0.7, 0.7, 0.3 and 0.4 µg L?1, respectively. The validation of the procedure was performed by the analysis of CRM (SRM NIST-1547 peach leaves and LGC6019 river water) standard reference materials. The method was applied to the determination of the analytes in real samples including natural waters, hair, urine, soil, sediment and peritoneal fluids samples etc., and good results were obtained (relative standard deviations <4%, recoveries >95%).  相似文献   

5.
A new adsorbent is synthesized on the basis of silica consecutively modified by polyhexamethylene guanidine and 4,5-dihydroxy-1,3-benzenedisulfonic acid (Tiron) for the group preconcentration of Fe(III), Al(III), Cu(II), Pb(II), Zn(II), and Mn(II) followed by determination by inductively coupled plasma atomic emission spectrometry. The adsorbent in the batch mode quantitatively (recovery 98?99%) extracts Fe(III), Al(III) and Cu(II) ions at pH 4.0 and Fe(III), Al(III), Cu(II), Pb(II), Zn(II), and Mn(II) ions at pH 7.0; the time of attainment of an adsorption equilibrium does not exceed 10 min. Consecutive preconcentration at pH 4.0 and 7.0 in the batch and dynamic modes ensures the quantitative separation of Fe(III), Al(III), and Cu(II) from Pb(II), Zn(II), and Mn(II) and their separate determination. The quantitative desorption of metals was attained with 0.5?1.0 M HNO3 (5 or 10 mL). In preconcentration from 200 mL of solution with 5 mL of a desorbing solution, the preconcentration coefficient was equal to 40. The developed procedure was used for the determination of metal ions in river waters of Krasnoyarsk Krai. The results obtained were verified by the added?found method.  相似文献   

6.
李全民  吴宏伟  刘国光 《化学学报》2006,64(11):1169-1172
建立了一种利用修饰有结晶紫(CV)的微晶酚酞作为固态吸附剂分离富集溶液中痕量Zn(II)的新方法, 富集后的Zn(II)含量可直接用光度法测定. 控制一定条件, Zn(II)能与常见阳离子Ni(II), Cd(II), Al(III), Ca(II), Mg(II), Co(II), Mn(II), Cu(II), Pb(II), Fe(III)等完全分离, 且富集时基本不受, , Br, Cl, I,等阴离子影响. 微晶酚酞对Zn(II)的吸附容量为25.8 mg/g; 富集因数可达200倍, 回收率在97.7%~102%之间, RSD小于2.7%. 该方法已成功应用于实际水样中Zn(II)的富集测定, 结果令人满意.  相似文献   

7.
A new chelating resin, Xylenol Orange coated Amberlite XAD-7, was prepared and used for preconcentration of Cd(II), Co(II), Cu(II), Fe(III), Ni(II) and Zn(II) prior to their determination by flame atomic absorption spectrophotometry. The optimum pH values for quantitative sorption of Cd(II), Co(II), Cu(II), Fe(III), Ni(II) and Zn(II) are 4.5-5.0, 4.5, 4.0-5.0, 4.0, 5.0 and 5.0-7.0, respectively, and their desorptions by 2 mol L(-1) HCl are instantaneous. The sorption capacity of the resin has been found to be 2.0, 2.6, 1.6, 1.6, 2.6 and 1.8 mg g(-1) of resin for Cd, Co, Cu, Fe, Ni and Zn, respectively. The tolerance limits of electrolytes, NaCl, NaF, NaI, NaNO3, Na2SO4 and of cations, Mg2+ and Ca2+ in the sorption of the six metal ions are reported. The preconcentration factor was between 50 and 200. The t1/2 values for sorption are found to be 5.3, 2.9, 3.2, 3.3, 2.5 and 2.6 min for the six metals, respectively. The recoveries are between 96.0 and 100.0% for the different metals at preconcentration limits between 10 to 40 ng mL(-1). The preconcentration method has been applied to determine the six metal ions in river water samples after destroying the organic matter (if present in very large amount) with concentrated nitric acid (RSD < or = 8%, except for Cd for which it is upto 12.6%) and cobalt content of vitamin tablets with RSD of approximately 3.0%.  相似文献   

8.
Pyrrolidinedithiocarbamate (PDTC) chelates of Zn(II), Cu(II), Ni(II), Co(III), Fe(III), Mn(II), Cr(III), and VO(II) were analysed by capillary GC on a DB-1701 column (30 m x 0.25 mm id) with flame ionisation detection (FID). Linear calibrations were attained within "1-30 microg/mL" for Ni(II), Fe(III), Mn(II), Cr(III), Cu(II), and VO(II), and within "2-50 microg/mL" for Co(III) and Zn(II). The limits of detection were in the "150-500 ng/mL" range, corresponding to 15-50 pg amounts reaching the FID system. The optimised method was applied to the determination of Cu(II) and Ni(II) in coins, and that of Zn(II), Cu(II), Ni(II), Fe(III), Mn(II), Cr(III), and VO(II) in pharmaceutical preparations with relative standard deviations within 1.1-5.2%. The results obtained are in good agreement with sewage water samples and the declared values for the pharmaceutical formulations, or with the results of AAS of metal contents in coins, pharmaceutical preparations, and sewage water samples.  相似文献   

9.
A method for heavy metal monitoring using spectrophotometric detection is presented. Traces of Cu(II), Pb(II) and Cd(II) at the low microg l(-1) level can be determined simultaneously after both selective removal of metal interferences and preconcentration using 'extraction chromatographic resins'. Lewatit TP807'84, which contains di(2,4,4-trimethylpentyl)phosphinic acid as active component, was used as solid adsorbent. Two minicolumns containing this resin were used: one at pH 3.2 for the removal of interferences, such as Zn(II) and Fe(III), and the other at pH 5.5 for the selective preconcentration of the target analytes. Spectrophotometric determination used FIA methodology with sulfarsazene as chromogenic reagent and partial least-squares multivariate calibration. The method was successfully applied to the analysis of surface waters from the Llobregat river and ground water samples from wells in the Guadiamar basin. Accuracy, expressed in terms of recoveries, was in the range 80-120% and relative standard deviations were below 10%.  相似文献   

10.
We have covalently grafted phenyl-iminodiacetic acid groups onto multi-walled carbon nanotubes via a diazotation reaction. The resulting material was characterized by FT-IR and UV–vis spectroscopy, by TGA, XPS and SEM. It is shown to be a valuable solid-phase extraction adsorbent for the preconcentration of trace quantities of Fe(III), Cu(II) and Pb(II) ion from aqueous solution prior to their determination by ICP-OES. Various factors affectting the separation and preconcentration were investigated. The enrichment factor typically is 100. Under optimized experimental conditions, the maximum adsorption capacities for Fe(III), Cu(II) and Pb (II) are 64.5, 30.5 and 17.0?mg?g-1, respectively, the detection limits are 0.26, 0.15 and 0.18?ng?mL-1, and the relative standard deviations are <2.5% (n?=?6). The new adsorbent shows superior reusability and stability. The procedure was successfully applied to the determination of trace quantities of Fe(III), Cu(II) and Pb (II) in water samples.
Figure
Multiwalled carbon nanotubes grafted with phenyl-iminodiacetic acid (PIDA-MWCNTs) is prepared and employed as solid phase extraction sorbent to determinate the trace Fe(III), Cu(II) and Pb (II) in water samples. The method has been applied to the preconcentration of trace amount of Fe(III), Cu(II) and Pb (II) in water samples with satisfactory results.  相似文献   

11.
A sensitive and simple method for determination of iron species after separation/preconcentration by cloud point extraction (CPE) has been developed. When the temperature is higher than the cloud point extraction temperature (60 °C), the complexes of iron(II) and iron(III) species with ferron enter the surfactant-rich phase. Total amount of iron in the surfactant-rich phase was analyzed by FI-AAS, whereas, Fe(II) concentration was determined by a spectrophotometric method using mathematical equation to overcome the interference of Fe(III), when they are both present in the same solution. In this way the time-consuming and labor-intensive steps of preoxidation of Fe(II) or reduction of Fe(III) were eliminated. The parameters affecting could point extraction, such as concentrations of ferron and Triton X-114, pH, and equilibrium temperature were systematically investigated. Under the optimum conditions, the calibration curves were linear over the range of 10-250 and 5-150 μg l-1 for 20 and 40 ml preconcentration volume, respectively. The detection limit was 1.7 μg l-1, and relative standard deviation (RSD) was 2.1% for 20 ml preconcentration volume. The method was applied to the determination of iron species in water samples and total iron in milk. The accuracy was determined by recovery experiment, independent analysis by furnace atomic absorption spectrometry and analysis of certified reference water.  相似文献   

12.
A solid co-precipitated material obtained from an ion-pair of 2-(5-bromo-2-pyridylazo)-5-diethylaminophenol (5-Br-PADAP) and tetraphenylborate (TPB), and microcrystals of naphthalene has been tried as an adsorbent for the column preconcentration of copper(I), iron(II), nickel(II) and Zn(II). The retention of the metal ions was found to be maximum and constant in the pH range 3.0-8.0 for Cu, 3.8-7.5 for Fe, 4.5-7.5 for Ni and 8.5-11.0 for Zn. The elements were determined by FAAS after dissolving the metal along with the adsorbent in an organic solvent (10 mL of DMF). The characteristic concentration for 1% absorption was found to be 0.0332, 0.0536, 0.0537 and 0.0142 (aqueous medium 0.0512, 0.0638, 0.1294 and 0.0216) microg mL(-1) for Cu, Fe, Ni and Zn, respectively. The calibration plot was linear in the range 1.5-20.0, 2.0-38.0, 2.5-25.0 and 0.5-15.0 micro g in the final 10 mL of DMF solution for Cu, Fe, Ni and Zn, respectively. Various parameters such as pH, volume of buffer, amount of adsorbent, flow rate, preconcentration factor and effect of diverse salts and cations were studied. The optimised conditions were utilized for the determination of Cu, Fe, Ni and Zn in various water, beverage and human hair samples.  相似文献   

13.
Pu X  Hu B  Jiang Z  Huang C 《The Analyst》2005,130(8):1175-1181
A method has been developed for the speciation of trace dissolved Fe(II) and Fe(III) in water by coupling gallic acid (GA) modified nanometer-sized alumina micro-column separation with inductively coupled plasma mass spectrometry (ICP-MS). The separation of Fe(II) and Fe(III) was achieved based on the obvious difference in reaction kinetics between Fe(II) and Fe(III) with GA. Fe(III) was selectively retained on the micro-column at pH 5.5-6.5, while Fe(II) could not be retained by the micro-column at the whole tested pH range of 1.0-6.5, and passed through the micro-column. The Fe(II) can be determined by ICP-MS directly without preconcentration/separation procedure, while Fe(III) retained on the micro-column was then eluted with 1.0 mL of 1 mol L(-1) HCl and determined by ICP-MS. The parameters affecting the separation of Fe(II) and Fe(III) were investigated systematically and the optimum separation conditions were established. Under the optimized conditions, the detection limits of 0.48 microg L(-1) and 0.24 microg L(-1) with relative standard deviation of 5.6% and 4.3%(C= 5 microg L(-1), n= 7) for Fe(II) and Fe(III) were found, respectively. No obvious effect on the speciation of Fe(II) and Fe(III) was found with the change of the ratio of Fe(II) and Fe(III) from 0 ratio 10 to 10 ratio 0. The proposed method was applied for the determination of trace Fe(II) and Fe(III) in environmental water and the recoveries for spiked samples were found to be in the range of 97-105%.  相似文献   

14.
Li Zhu 《Talanta》2010,80(5):1873-159
In this paper, a solid-phase extraction (SPE) method based on mixed hemimicelles of cetyltrimethyl ammonium bromide (CTAB) on silica-coated magnetic nanoparticles (MNPs) is developed for extraction and preconcentration of compounds from the biological samples. We selected rhein and emodin which are the major active anthraquinones of rhubarb as model analytes. A high performance liquid chromatography-fluorescence detection (HPLC/FLD) method was developed for the determination of rhein and emodin in urine and serum samples. The main factors influencing the extraction efficiency including the amount of surfactant, the concentration of MNPs, the shaking time and the desorption ability of organic solvents were investigated and optimized. No interferences were caused by proteins or endogenous compounds in urine and serum samples. Good linearities (r2 > 0.9995) for all calibration curves were obtained, and the limits of detection (LODs) for rhein and emodin were 0.2 and 0.5 ng/mL in urine samples and 7 and 10 ng/mL in serum samples, respectively. Satisfactory recoveries (92.76-109.90% and 97.53-107.72% for rhein and emodin) in the biological matrices were achieved.  相似文献   

15.
Silva MF  Fernandez LP  Olsina RA 《The Analyst》1998,123(9):1803-1807
An extraction methodology based on cloud point phase separation of non-ionic surfactants has been developed for the preconcentration of ppb amounts of gadolinium in urine as a prior step to its determination by an absorptiometric procedure. A method based on the formation of complexes with 2-(3,5-dichloro-2-pyridylazo)-5-dimethylaminophenol was used for the extraction of Gd(III) in the surfactant-rich phase of non-ionic surfactant polyethyleneglycolmono-p-nonylphenylether (PONPE 7.5). The variables affecting the combined preconcentration-absorptiometric method have been evaluated and optimised. The extraction efficiency, linearity, and the limit of detection (LOD) of the method were determined. The optimised procedure was applied to determine total and free Gd(III) contents in real urine samples of patients after the NMR imaging diagnostic examination with contrast agent.  相似文献   

16.
《Analytical letters》2012,45(9):1807-1820
ABSTRACT

5-amino-1,3,4-thiadiazole-2-thiol groups attached on a silica gel surface have been used for adsorption of Cd(II), Co(II), Cu(II), Fe(III), Ni(II), Pb(II) and Zn(II) from aqueous solutions. The adsorption capacities for each metal ion were (in mmol.g?1): Cd(II)= 0.35, Co(II)= 0.10, Cu(II)= 0.15, Fe(III)= 0.20, Hg(II)= 0.46, Ni(II)= 0.16, Pb(II)= 0.13 and Zn(II)= 0.15. The modified silica gel was applied in the preconcentration and quantification of trace level metal ions present in water samples (river, and bog water).  相似文献   

17.
A simple back-extraction method was developed for the separation and preconcentration of trace levels of zinc from different matrices. Ethyl-2-(4-methoxybenzoyl)-3-(4-methoxyphenyl)-3-oxopropanoylcarbamate (EMPC) was used as a new complexing agent for the extraction of zinc(II) from the aqueous sample phase to the methyl isobutyl ketone (MIBK) phase as Zn(EMPC)2 complexes. The Zn(II) can be selectively stripped with 1?mL of 0.5?mol?L?1 HCl from Mn+(EMPC)n complexes [Ag(I), Al(III), Cd(II), Cr(III), Cu(II), Fe(II), Fe(III), Mn(II), Ni(II), Pb(II) and Pd(II)] which dissolved in MIBK phase. Some experimental parameters, which are important for the whole extraction process, including pH, sample volume, shaking time, amount of the EMPC reagent, amount of MIBK, ionic strength, and type of back-extractant were investigated. The recovery for Zn(II) was greater than 95%. The detection limit of the method was found to be 0.2?µg?L ? 1 and the relative standard deviation as 6.4%. The concentrations of Zn(II) in the certified reference materials (LGC6019 river water and NIST-1547 peach leaves) by the presented method were in good agreement with the certified values. The proposed method was succesfully applied to the determination of zinc in some natural waters, rice, hair, soil, and tea samples.  相似文献   

18.
A sensitive solid-phase extraction technique (SPE) for the enrichment of Fe(III), Co(II), Mn(II) and Cr(III) prior to atomic absorption spectrometric analysis is described. Escherichia coli immobilized on Amberlite XAD-4 was used as a solid-phase extractor. The effects of the pH, amount of solid-phase, eluent type and volume of the sample solution on the recovery of the metal ions were investigated. The effect of diverse ions was also investigated. The recoveries of Fe(III), Co(II), Mn(II) and Cr(III) under the optimum conditions were found to be 99 +/- 2, 99 +/- 3, 98 +/- 2, 98 +/- 3%, respectively, at the 95% confidence level. The detection limits of the metal ions were found as to be 2.4, 3.8, 1.3 and 1.7 ng ml(-1) for Fe(II), Co(II), Mn(II) and Cr(III) respectively, by applying a preconcentration factor of 25. The proposed enrichment method was applied to the determination of analytes in Atatürk Dam water samples, and alloy samples (RSD < 5%). The accuracy of the method was verified on certified alloy samples (NBS SRM 85b and NBS SRM 59a). The analytes were determined with a relative error lower than 5% in water and alloy samples.  相似文献   

19.
A new method based on the combination of magnetic solid phase extraction (MSPE) and spectrofluorimetric determination was developed for isolation and preconcentration of fluoxetine form aquatic and biological samples using sodium dodecyl sulfate (SDS) coated Fe(3)O(4) nanoparticles (NPs) as a sorbent. The unique properties of Fe(3)O(4) NPs including high surface area and strong magnetism were utilized effectively in the MSPE process. Effect of different parameters influencing the extraction efficiency of fluoxetine including the amount of Fe(3)O(4) and SDS, pH value, sample volume, extraction time, desorption solvent and time were optimized. Under optimized condition, the method was successfully applied to the extraction of fluoxetine from water and urine samples and absolute recovery amount of 85%, detection limit of 20 μg L(-1) and a relative standard deviation (RSD) of 1.4% were obtained. The method linear response was over a range of 50-1000 μg L(-1) with R(2)=0.9968. The relative recovery in different aquatic and urine matrices were investigated and values of 80% to 104% were obtained. The whole procedure showed to be conveniently fast, efficient and economical for extraction of fluoxetine from environmental and biological samples.  相似文献   

20.
The use of the chemically modified silica gel N-(3-propyl)-O-phenylenediamine (SiG-NPPDA) adsorbent, for the preconcentration and separation of trace heavy metals, was described. SiG-NPPDA sorbs quantitatively (90-100% recovery) trace amounts of nine heavy metals, viz., Cd(II), Zn(II), Fe(III), Cu(II), Pb(II), Mn(II), Cr(III), Co(II) and Ni(II) at pH 7-8. The sorption capacity varies from 350 to 450 micromol g(-1). Desorption was found to be quantitative with 1-2 M HNO3 or 0.05 M Na2EDTA. The distribution coefficient, Kd and the percentage concentration of the investigated metal ions on the adsorbent at equilibrium, C(M,eqm)% (Recovery, R%), were studied as a function of experimental parameters. The logarithmic values of the distribution coefficient, log Kd, ranges between 4.0 and 6.4. Some foreign ions caused little interference in the preconcentration and determination of the investigated nine metals by flame atomic absorption spectrometry (AAS). The adsorbent and its formed metal chelates were characterized by IR (absorbance and/or reflectance), potentiometric titrations and thermogravimetric analysis (TGA and DTG). The mode of chelation between the SiG-NPPDA adsorbent and the investigated metal ions is proposed to be due to the reaction of the investigated metal ions with the two nitrogen atoms of the SiG-NPPDA adsorbent. The present adsorbent coupled with flame AAS has been used to enrich and determine the nine metal ions in natural aqueous systems and in certified reference materials (RSD < or = 5%). The copper, iron, manganese and zinc present in some pharmaceutical vitamin samples were also preconcentrated on SiG-NPPDA adsorbent and determined by flame AAS (RSD < or = 4.2%). Nanogram concentrations (0.07-0.14 ng ml(-1)) of Cd(II), Zn(II), Fe(III), Pb(II), Cr(III), Mn(II), Cu(II), Co(II) and Ni(II) can be determined reliably with a preconcentration factor of 100.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏