首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
To assess the reproducibility of quantitative measurements of cartilage morphology and trabecular bone structure of the knee at 7 T, high-resolution sagittal spoiled gradient-echo images and high-resolution axial fully refocused steady-state free-precession (SSFP) images from six healthy volunteers were acquired with a 7-T scanner. The subjects were repositioned between repeated scans to test the reproducibility of the measurements. The reproducibility of each measurement was evaluated using the coefficient(s) of variation (CV). The computed CV were 1.13% and 1.55% for cartilage thickness and cartilage volume, respectively, and were 2.86%, 1.07%, 2.27% and 3.30% for apparent bone volume over total volume fraction (app.BV/TV), apparent trabecular number (app.Tb.N), apparent trabecular separation (app.Tb.Sp) and apparent trabecular thickness (app.Tb.Th), respectively. The results demonstrate that quantitative assessment of cartilage morphology and trabecular bone structure is reproducible at 7 T and motivates future musculoskeletal applications seeking the high-field strength's superior signal-to-noise ratio.  相似文献   

2.
The lamellar structure of osteoporotic human trabecular bone was characterized experimentally by means of transmission electron microscopy (TEM). More specifically, the TEM was used to determine if trabecular bone exhibits similar lamellar structural motifs as cortical bone by analyzing unmineralized, mineralized and demineralized bone, and to study the influence of the osteocyte network on the lamellar structure of osteoporotic trabecular bone. Comparison with normal trabecular bone is included. This paper summarizes partial results of a larger study, which addressed the characterization of the hierarchical structure of normal versus osteoporotic human trabecular bone [Rubin, M.A., 2001. Multiscale characterization of the ultrastructure of trabecular bone in osteoporotic and normal humans and in two inbred strains of mice. MS Thesis, Georgia Institute of Technology.] at several structural scales.  相似文献   

3.
A novel segmentation method based on wavelet transform is presented for gray matter, white matter and cerebrospinal fluid in thin-sliced single-channel brain magnetic resonance (MR) scans. On the basis of the local image model, multicontext wavelet-based thresholding segmentation (MCWT) is proposed to classify 2D MR data into tissues automatically. In MCWT, the wavelet multiscale transform of local image gray histogram is done, and the gray threshold is gradually revealed from large-scale to small-scale coefficients. Image segmentation is independently performed in each local image to calculate the degree of membership of a pixel to each tissue class. Finally, a strategy is adopted to integrate the intersected outcomes from different local images. The result of the experiment indicates that MCWT outperforms other traditional segmentation methods in classifying brain MR images.  相似文献   

4.
The purpose of this work was to apply fuzzy logic image processing techniques to characterize the trabecular bone structure with high-resolution magnetic resonance images. Fifteen ex vivo high-resolution magnetic resonance images of specimens of human radii at 1.5 T and 12 in vivo high-resolution magnetic resonance images of the calcanei of peri- and postmenopausal women at 3 T were obtained. Soft segmentation using fuzzy clustering was applied to MR data to obtain fuzzy bone volume fraction maps, which were then analyzed with three-dimensional (3D) fuzzy geometrical parameters and measures of fuzziness. Geometrical parameters included fuzzy perimeter and fuzzy compactness, while measures of fuzziness included linear index of fuzziness, quadratic index of fuzziness, logarithmic fuzzy entropy, and exponential fuzzy entropy. Fuzzy parameters were validated at 1.5 T with 3D structural parameters computed from microcomputed tomography images, which allow the observation of true trabecular bone structure and with apparent MR structural indexes at 1.5 T and 3 T. The validation was statistically performed with the Pearson correlation coefficient as well as with the Bland-Altman method. Bone volume fraction correlation values (r) were up to .99 (P<.001) with good agreements based on Bland-Altman analysis showing that fuzzy clustering is a valid technique to quantify this parameter. Measures of fuzziness also showed consistent correlations to trabecular number parameters (r>.85; P<.001) and good agreements based on Bland-Altman analysis, suggesting that the level of fuzziness in high-resolution magnetic resonance images could be related to the trabecular bone structure.  相似文献   

5.
A novel semi-empirical scattering model of trabecular bone facilitating its characterization and allowing optimization of the interrogating pulse-echo transducer performance was developed. The model accounts for spatial density distribution of the trabeculae and includes measurement conditions such as pressure–time waveform of the probing ultrasound wave, the emitted field structure, and the transfer function and limited bandwidth of the acoustic source operating in pulse-echo mode. These measurement conditions are of importance as they modify the scattered echoes, which in turn are linked to the micro-architecture of the bone. The bone was modeled by a random distribution of long and thin cylindrical scatterers having randomly varying diameters and mechanical properties, and oriented perpendicularly to the ultrasound beam axis. To mimic clinically encountered conditions the relevant empirical data obtained at 1 MHz were input to the model. The data included pulse-echo source pressure field distribution in the focal zone and the above mentioned transfer function. With these data the model allowed frequency dependent backscattering coefficient of the simulated bone structure and its statistical properties to be determined. The results obtained indicated that the computer simulation is of particular relevance in studying scattering properties of the cancellous bone and holds promise as a tool to determine the relationship between the physical dimensions and shape of the scatterers and for monitoring of osteoporosis. The results of simulations also indicated that the new bone model proposed is well suited to mimic clinically relevant conditions. In contrast to the existing bone models, which usually assume scatterers to be randomly distributed as infinitely long identical cylinders with a cross-section much smaller than the probing ultrasound wave, the new model includes two populations of scatterers having different physical dimensions and also allows the mechanical properties of the scatterers to be varied.  相似文献   

6.
Specialized implants are used for transcatheter closure of septal defects, including atrial and ventricular septal defects, and patent foramen ovale. These metallic devices may pose a risk to patients undergoing magnetic resonance imaging (MRI) procedures especially if performed at 3 T. Therefore, this investigation evaluated MRI safety at 3 T for septal repair implants (CardioSEAL Septal Repair Implant and STARFlex Septal Repair Implant, NMT Medical, Boston, MA, USA) by characterizing magnetic field interactions, heating and artifacts. These implants exhibited minor magnetic field interactions; heating was not excessive (+0.5°C); and artifacts will only create a problem if the area of interest is in the same area as or near these devices. Thus, the findings indicated that it would be safe for a patient with these implants to undergo MRI at 3 T or lower. Importantly, because of the minor magnetic field interactions, MRI may be performed immediately after implantation.  相似文献   

7.
Diffusion weighted magnetic resonance imaging (DWI) has been mostly acquired using single-shot echo-planar imaging (ss EPI) to minimize motion induced artifacts. The spatial resolution, however, is inherently limited in ss EPI especially for abdominal imaging, even with the advances in parallel imaging. A novel method of reduced Field of View ss EPI (rFOV ss EPI) has achieved high resolution DWI in human carotid artery, spinal cord with reduced blurring and higher spatial resolution than conventional ss EPI, but it has not been used to pancreas imaging. In the work, comparisons between the full FOV ss-DW EPI and rFOV ss-DW EPI in image qualities and ADC values of pancreatic tumors and normal pancreatic tissues were performed to demonstrate the feasibility of pancreatic high resolution rFOV DWI. There were no significant differences in the mean ADC values between full FOV DWI and rFOV DWI for the 17 subjects using b = 600 s/mm2 (P = 0.962). However, subjective scores of image quality was significantly higher at rFOV ss DWI (P = 0.008 and 0.000 for b-value = 0 s/mm2 and 600 s/mm2 respectively). The spatial resolution of DWI for pancreas was increased by a factor of over 2.0 (from almost 3.0 mm/pixel to 1.25 mm/pixel) using rFOV ss EPI technique. Reduced FOV ss EPI can provide good DW images and is promising to benefit applications for pancreatic diseases.  相似文献   

8.
A Helmholtz-pair local transmit RF coil with an integrated four-element receive array RF coil and foot immobilization platform was designed and constructed for imaging the distal tibia in a whole-body 7T MRI scanner. Simulations and measurements of the B(1) field distribution of the transmit coil are described, along with SAR considerations for operation at 7T. Results of imaging the trabecular bone of three volunteers at 1.5T, 3T and 7T are presented, using identical 1.5T and 3T versions of the 7T four-element receive array. The spatially registered images reveal improved visibility for individual trabeculae and show average gains in SNR of 2.8× and 4.9× for imaging at 7T compared to 3T and 1.5T, respectively. The results thus display an approximately linear dependence of SNR with field strength and enable the practical utility of 7T scanners for micro-MRI of trabecular bone.  相似文献   

9.
Fe3O4 magnetic nanoparticles were prepared by co-precipitation from FeSO4·7H2O and FeCl3·6H2O aqueous solutions using NaOH as precipitating reagent. The nanoparticles have an average size of 12 nm and exhibit superparamagnetism at room temperature. The nanoparticles were used to prepare a water-based magnetic fluid using oleic acid and Tween 80 as surfactants. The stability and magnetic properties of the magnetic fluid were characterized by Gouy magnetic balance. The experimental results imply that the hydrophilic block of Tween 80 can make the Fe3O4 nanoparticles suspending in water stable even after dilution and autoclaving. The magnetic fluid demonstrates excellent stability and fast magneto-temperature response, which can be used both in magnetic resonance imaging and magnetic fluid hyperthermia.  相似文献   

10.
This work investigated macrophages labeled with magnetosomes for the possible detection of inflammations by MR molecular imaging. Pure magnetosomes and macrophages containing magnetosomes were analyzed using a clinical 1.5 T MR-scanner. Relaxivities of magnetosomes and relaxation rates of cells containing magnetosomes were determined. Peritonitis was induced in two mice. T1, T2 and T2* weighted images were acquired following injection of the probes. Pure magnetosomes and labeled cells showed slight effects on T1, but strong effects on T2 and T2* images. Labeled macrophages were located with magnetic resonance imaging (MRI) in the colon area, thus demonstrating the feasibility of the proposed approach.  相似文献   

11.
In preclinical research, genetic studies have made considerable progress as a result of the development of transgenic animal models of human diseases. Consequently, there is now a need for higher resolution MRI to provide finer details for studies of small animals (rats, mice) or very small animals (insects). One way to address this issue is to work with high-magnetic-field spectrometers (dedicated to small animal imaging) with strong magnetic field gradients. It is also necessary to develop a complete methodology (transmit/receive coil, pulse sequence, fixing system, air supply, anesthesia capabilities, etc.). In this study, we developed noninvasive protocols, both in vitro and in vivo (from coil construction to image generation), for drosophila MRI at 9.4 T. The 10*10*80-μm resolution makes it possible to visualize whole drosophila (head, thorax, abdomen) and internal organs (ovaries, longitudinal and transverse muscles, bowel, proboscis, antennae and optical lobes). We also provide some results obtained with a Drosophila model of muscle degeneration. This opens the way for new applications of structural genetic modification studies using MRI of drosophila.  相似文献   

12.
In this study, we present a novel methodology that allows reliable segmentation of the magnetic resonance images (MRIs) for accurate fully automated three-dimensional (3D) reconstruction of the carotid arteries and semiautomated characterization of plaque type. Our approach uses active contours to detect the luminal borders in the time-of-flight images and the outer vessel wall borders in the T(1)-weighted images. The methodology incorporates the connecting components theory for the automated identification of the bifurcation region and a knowledge-based algorithm for the accurate characterization of the plaque components. The proposed segmentation method was validated in randomly selected MRI frames analyzed offline by two expert observers. The interobserver variability of the method for the lumen and outer vessel wall was -1.60%±6.70% and 0.56%±6.28%, respectively, while the Williams Index for all metrics was close to unity. The methodology implemented to identify the composition of the plaque was also validated in 591 images acquired from 24 patients. The obtained Cohen's k was 0.68 (0.60-0.76) for lipid plaques, while the time needed to process an MRI sequence for 3D reconstruction was only 30 s. The obtained results indicate that the proposed methodology allows reliable and automated detection of the luminal and vessel wall borders and fast and accurate characterization of plaque type in carotid MRI sequences. These features render the currently presented methodology a useful tool in the clinical and research arena.  相似文献   

13.
It is a big challenge to segment magnetic resonance (MR) images with intensity inhomogeneity. The widely used segmentation algorithms are region based, which mostly rely on the intensity homogeneity, and could bring inaccurate results. In this paper, we propose a novel region-based active contour model in a variational level set formulation. Based on the fact that intensities in a relatively small local region are separable, a local intensity clustering criterion function is defined. Then, the local function is integrated around the neighborhood center to formulate a global intensity criterion function, which defines the energy term to drive the evolution of the active contour locally. Simultaneously, an intensity fitting term that drives the motion of the active contour globally is added to the energy. In order to segment the image fast and accurately, we utilize a coefficient to make the segmentation adaptive. Finally, the energy is incorporated into a level set formulation with a level set regularization term, and the energy minimization is conducted by a level set evolution process. Experiments on synthetic and real MR images show the effectiveness of our method.  相似文献   

14.

Background and Purpose

Fluid-sensitive MR imaging in postoperative evaluation is important, however, metallic artifacts is inevitable. The purpose is to investigate the feasibility of fat-saturated slice encoding for metal artifact correction (SEMAC)-corrected T2-weighted magnetic resonance (MR) at 3T in patients with spinal prostheses.

Methods

Following institutional review board approval, 27 SEMAC-encoded spinal MRs between September 2012 and October 2013 in patients with spinal metallic prostheses were analyzed. The MR images were scanned on a 3T MR system including SEMAC-corrected and uncorrected fast spin echo (FSE) T2-weighted MR images with fat-saturation. Two musculoskeletal radiologists compared the image sets and qualitatively analyzed the images using a five-point scale in terms of artifact reduction around the prosthesis, visualization of the prosthesis and pedicle, and intervertebral neural foramina. Quantitative assessments were performed by calculating the ratio of signal intensity from the fixated vertebra and that from upper level vertebra. For statistical analyses, paired t-test was used.

Results

Fat-saturated SEMAC-corrected T2-weighted MR images enabled significantly improved metallic artifact reduction (P < 0.05). Quantitative evaluation of the signal intensity ratio of screw-fixated vertebra and upper level vertebra showed a significantly lower ratio on fat-saturated SEMAC images (P < 0.05), however, the high signal intensity of signal pile-up could be not completely corrected.

Conclusion

SEMAC correction in fat-suppressed T2-weighted MR images can overcome the signal loss of metallic artifacts and provide improved delineation of the pedicle screw and peri-prosthetic region. Signal pile-up, however, could not be corrected completely, therefore readers should be cautious in the evaluation of marrow around the prosthesis.  相似文献   

15.
Multi-modality imaging (such as PET-CT) is rapidly becoming a valuable tool in the diagnosis of disease and in the development of new drugs. Functional images produced with PET, fused with anatomical images created by MRI, allow the correlation of form with function. Perhaps more exciting than the combination of anatomical MRI with PET, is the melding of PET with MR spectroscopy (MRS). Thus, two aspects of physiology could be combined in novel ways to produce new insights into the physiology of normal and pathological processes. Our team is developing a system to acquire MRI images and MRS spectra, and PET images contemporaneously. The prototype MR-compatible PET system consists of two opposed detector heads (appropriate in size for small animal imaging), operating in coincidence mode with an active field-of-view of approximately 14 cm in diameter. Each detector consists of an array of LSO detector elements coupled through a 2-m long fiber optic light guide to a single position-sensitive photomultiplier tube. The use of light guides allows these magnetic field-sensitive elements of the PET imager to be positioned outside the strong magnetic field of our 3T MRI scanner. The PET scanner imager was integrated with a 12-cm diameter, 12-leg custom, birdcage coil. Simultaneous MRS spectra and PET images were successfully acquired from a multi-modality phantom consisting of a sphere filled with 17 brain relevant substances and a positron-emitting radionuclide. There were no significant changes in MRI or PET scanner performance when both were present in the MRI magnet bore. This successful initial test demonstrates the potential for using such a multi-modality to obtain complementary MRS and PET data.  相似文献   

16.
In magnetic resonance (MR) imaging of small animals, the gastrointestinal contents may give rise to intense signals on T1-weighted images. The aim of this study was to determine the optimal dietary preparation to reduce gastrointestinal signals in mice and to evaluate the usefulness of this approach. Images of the mouse trunk were obtained using a T1-weighted, three-dimensional fast low-angle shot sequence under various dietary conditions and were compared with respect to the gastrointestinal signals and image quality. The dietary preparation studied included giving alternative diets for 24 h, intestinal cleansing, and 6-h fasting. Mice with and without dietary preparation underwent MR lymphography using gadofluorine 8, and the visualization of abdominal lymph nodes was compared. In the absence of dietary preparation, hyperintense areas were conspicuous in the gastrointestinal system, whereas on the images taken from mice fed potato or sweet potato for 24 h before imaging, gastrointestinal hyperintensity was less prominent. This preparation also reduced artifactual signals and resulted in higher-quality images of the kidneys. Intestinal cleansing, which consisted of 24-h fasting and laxative intake, did not reduce the gastrointestinal signals and caused signal changes that were indicative of fatty liver development. Some of the abdominal lymph nodes of the mice that did not receive dietary preparation were visualized on MR lymphography source images but not on maximum intensity projection (MIP) images. In contrast, on the MIP images of mice fed potato, all the lymph nodes delineated on the source images were successfully visualized. In conclusion, feeding mice potato or sweet potato for 24 h before MR imaging reduces the gastrointestinal signals and image degradation due to artifacts. Appropriate dietary preparations facilitate the display of target structures on MIP images and are expected to enhance the capabilities of small animal MR imaging.  相似文献   

17.
Surface-based functional magnetic resonance imaging (fMRI) analysis is more sensitive and accurate than volume-based analysis for detecting neural activation. However, these advantages are less important in practical fMRI experiments with commonly used 1.5-T magnetic resonance devices because of the resolution gap between the echo planar imaging data and the cortical surface models. We expected high-resolution segmented partial brain echo planar imaging (EPI) data to overcome this problem, and the activation patterns of the high-resolution data could be different from the low-resolution data. For the practical applications of surface-based fMRI analysis using segmented EPI techniques, the effects of some important factors (e.g., activation patterns, registration and local distortions) should be intensively evaluated because the results of surface-based fMRI analyses could be influenced by them. In this study, we demonstrated the difference between activations detected from low-resolution EPI data, which were covering whole brain, and high-resolution segmented EPI data covering partial brain by volume- and surface-based analysis methods. First, we compared the activation maps of low- and high-resolution EPI datasets detected by volume- and surface-based analyses, with the spatial patterns of activation clusters, and analyzed the distributions of activations in occipital lobes. We also analyzed the high-resolution EPI data covering motor areas and fusiform gyri of human brain, and presented the differences of activations detected by volume- and surface-based methods.  相似文献   

18.
Magnetic resonance imaging of inhaled fluorinated inert gases ((19)F-MRI) such as sulfur hexafluoride (SF(6)) allows for analysis of ventilated air spaces. In this study, the possibility of using this technique to image lung function was assessed. For this, (19)F-MRI of inhaled SF(6) was compared with respiratory gas analysis, which is a global but reliable measure of alveolar gas fraction. Five anesthetized pigs underwent multiple-breath wash-in procedures with a gas mixture of 70% SF(6) and 30% oxygen. Two-dimensional (19)F-MRI and end-expiratory gas fraction analysis were performed after 4 to 24 inhaled breaths. Signal intensity of (19)F-MRI and end-expiratory SF(6) fraction were evaluated with respect to linear correlation and reproducibility. Time constants were estimated by both MRI and respiratory gas analysis data and compared for agreement. A good linear correlation between signal intensity and end-expiratory gas fraction was found (correlation coefficient 0.99+/-0.01). The data were reproducible (standard error of signal intensity 8% vs. that of gas fraction 5%) and the comparison of time constants yielded a sufficient agreement. According to the good linear correlation and the acceptable reproducibility, we suggest the (19)F-MRI to be a valuable tool for quantification of intrapulmonary SF(6) and hence lung function.  相似文献   

19.

Purpose

Left ventricular (LV) remodeling is usually assessed using global changes in LV volume. We hypothesized that three-dimensional analysis of regional endocardial curvature from magnetic resonance images could provide clinically useful information on localized LV remodeling. We tested this approach by investigating regional differences in endocardial curvature in normal and hypokinetic ventricles.

Materials and Methods

Images were obtained in 44 patients with normal LV function (NL, N=14), dilated cardiomyopathy (DCM, N=15) or ischemic heart disease (IHD, N=15). Local surface curvedness, normalized to take into account instantaneous LV size (Cn), was calculated throughout the cardiac cycle and compared between segment groups: NL (N=401), IHD (N=92) and DCM (N=255).

Results

In all normal segments, Cn gradually increased during systole and then decreased during diastole. While both maximum and minimum values of Cn were comparable in the basal and midventricular segments, they were significantly higher in the four apical segments and highest in the apical cap. In addition, percent change in Cn was higher in mid and apical compared to basal segments (P<.05). At all LV levels, Cn values in DCM segments were lower (P<.05) than in NL and IHD segments, which were similar. In contrast, percent change in Cn was significantly lower in both IHD and DCM segments compared to NL.

Conclusion

Three-dimensional analysis of LV endocardial curvature yielded quantitative information on regional ventricular shape consistent with the known pathophysiology, supporting its potential clinical usefulness in the evaluation of LV remodeling.  相似文献   

20.
Low grade gliomas were studied with ultra low field magnetic resonance imaging (ULF MRI). The tumors exhibited high tissue contrast in both T1 and T2-weighted images as compared to normal brain tissue. Moreover they were sharply delineated towards the surrounding brain tissue. When compared with X-ray computed tomography the tumors were more readily detected and delineated by using ultra-low field magnetic imaging. A computerassisted classification procedure was used to define new regions of interest for relaxation time estimation. By using this procedure more accurate estimations of the T1 and T2 values were obtained.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号