首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Guo R  Zhou Q  Cai Y  Jiang G 《Talanta》2008,75(5):1394-1399
A new method is developed for the determination of perfluorooctanesulfonate (PFOS) and perfluorooctanoic acid (PFOA) in sewage sludge samples. The analytes in sewage sludge samples are extracted by methanol and formic acid, cleaned by C18 solid-phase extraction, then separated, identified and quantitated by liquid chromatography/quadrupole time-of-flight mass spectrometry (LC–QTOF-MS). A C18 column (150 mm × 2.1 mm, 3.5 μm) with gradient elution of MeOH–H2O (60:40) containing 5 mmol/L ammonium acetate and MeOH–H2O (80:20) is used for the chromatographic separation. [M−K] ions at m/z 498.93 for PFOS and [M−COOH] ion at m/z 368.97 for PFOA are selected for QTOF-MS in the negative electrospray ionization mode. The detection limits for PFOS and PFOA in sewage sludge samples are 0.5 and 0.8 ng/g, respectively. The spiked recoveries are in the range of 85–114 and 71–98% for PFOS and PFOA, respectively. The proposed method is successfully applied to the analysis of PFOS and PFOA in 16 sewage sludge samples from China. PFOS and PFOA are detected in most sewage sludge samples and the concentrations of PFOS and PFOA are up to 5383 and 4780 ng/g (oven dry weight), respectively.  相似文献   

2.
A high-performance liquid chromatography/single quadrupole mass spectrometry (LC/MS) method is described for the determination of urinary S-phenylmercapturic acid (S-PMA), a specific metabolite of benzene. Urine samples were spiked with [13C6]S-PMA (used as the internal standard) and acidified; then they were purified by solid-phase extraction (SPE) on C18 cartridges. Analyses were conducted on a reversed-phase column by gradient runs with 1% aqueous acetic acid/methanol mixtures at different proportions as the mobile phase. The detector was used in electrospray negative ion mode (ESI-), the ions m/z 238 for S-PMA and 244 for [13C6]S-PMA being recorded simultaneously. The detection limit (for a signal-to-noise ratio = 3) was 0.2 microg/L, thus allowing for the measurement of background excretion of S-PMA in the general population. The use of the internal standard allowed us to obtain good precision (CV% values < 3%) and a linear calibration curve within the range of interest for monitoring occupational exposure to benzene (up to 500 microg/L). The method was applied to assay the metabolite concentration in a group of 299 workers (68 smokers and 231 non-smokers) occupationally exposed to relatively low levels of benzene (environmental concentration = 0.4-220 microg/m3, mean 11.4 microg/m3 and 236 non-exposed subjects (134 smokers and 102 non-smokers). The results clearly showed that smoking must be taken into account for the correct interpretation of the results of S-PMA measurements for the assessment of work-related benzene exposure. When only non-smokers were selected, the mean excretion of S-PMA was significantly higher in workers exposed to benzene (1.2 +/- 0.9 microg/g creatinine) than in the control group (0.7 +/- 0.6 microg/g creatinine) (p < 0.001), thus confirming the role of S-PMA as a biomarker of benzene on a group basis, even for relatively low exposure degrees.  相似文献   

3.
The potential of gas chromatography/tandem mass spectrometry with a triple quadrupole analyzer for determination of 12 polybrominated diphenyl ethers in human breast tissues has been investigated. After extraction with hexane, two purification procedures-automated normal-phase high-performance liquid chromatography and solid-phase extraction-were assayed. Both electron impact ionization, in selected reaction monitoring mode, and negative chemical ionization, in selected ion recording mode, were tested for the optimum determination of analytes. Isotopically labeled standards were added before extraction as surrogates: [13C]BDE47, [13C]BDE99 and [13C]BDE153 for electron impact ionization, and p,p′-DDE-d 8 for negative chemical ionization. The method was validated in terms of accuracy, precision, limits of detection and limits of quantification, using human breast tissue spiked at three levels in the range 1–50 ng/g (5–250 ng/g for BDE209). The analytical approach using solid-phase extraction cleanup followed by gas chromatography/mass spectrometry (negative chemical ionization ) led to lower detection limits (0.006–2 ng/g) and allowed the determination of the most problematic congener, BDE209, whose poor sensitivity made difficult its determination at low residue levels. Special attention was given to the confirmation of the compounds detected in samples in order to avoid reporting false positives. Two tandem mass spectrometry transitions or three m/z ions were selected for each analyte when using electron impact ionization or negative chemical ionization modes, respectively. In both cases, the transition to ion intensity ratio was used as a confirmation parameter. The method developed was applied to the analysis of real human samples. Several brominated diphenyl ethers (congeners 47, 100, 99, 154, 153, 183 and 209) were detected in the range 0.08–0.23 ng/g.  相似文献   

4.
Gestrinone was studied by high performance liquid chromatography (HPLC) for screening and by gas chromatography/mass spectrometry (GC/MS) for confirmation. When the chromatograms of blank, spiked urine and dosed urine were compared by HPLC, two unknown metabolites were found and these were excreted as the conjugated forms. Metabolites 1 and 2 were tested by LC/MS and LC/MS/MS and both had parent ions at m/z 325. The fragment ion of metabolite 1 was at m/z 263 and ions for metabolite 2 were m/z 307 [MH - H(2)O](+), 289, 279 and 241. LC/MS/MS of m/z 263 as the parent ion of metabolite 1 gave fragment ions at m/z 245 and 217, which were assumed to be [263 - H(2)O](+) and [235 - H(2)O](+), respectively. The trimethylsilyl (TMS)-enol-TMS ether derivative of gestrinone displayed three peaks in its GC/MS chromatogram, formed by tautomerism.  相似文献   

5.
On-line atmospheric pressure chemical ionization (APCI) and electrospray ionization (ESI) liquid chromatography/mass spectrometry (LC/MS) were evaluated for the analysis of a variety of steroids. Steroids were classified into three major groups based on the spectra and the sensitivities observed: (I) those containing a 3-one, 4-ene functional group, (II) those containing at least one ketone group without conjugation, and (III) those containing hydroxy group(s) only. In the APCI mode, the best sensitivity and the lowest detection limit for all three groups were obtained by using a mobile phase consisting of methanol and 1%–2% acetic acid in water. The APCI spectra were characterized by MH+, MH+-H2O, MH+-2H2O, etc., with the degree of H2O loss being compound dependent: group I steroids produced stable MH+ and group III steroids showed extensive water loss. In the electrospray mode the best sensitivity and the lowest detection limit for the first two groups were obtained when pure methanol and water were used as the mobile phase. This condition produced abundant stable MNa+ due to ubiquitous sodium. Detection limits in the 5–15 pg range can be easily achieved using ESI LC/MS. Addition of ammonium acetate or use of acetonitrile in the mobile phase, common in the LC/MS analysis of steroids, decreased the sensitivity for the group I and II steroids and thus should be avoided. For group III steroids, the detection limit can be improved by the addition of acetic acid to the mobile phase.  相似文献   

6.
A rapid and sensitive method for the determination of miglitol in human plasma using voglibose as internal standard has been developed and validated. Samples of plasma were deproteinated with acetonitrile and washed with dichloromethane before being analyzed by reversed-phase high-performance liquid chromatography (HPLC). Separation was carried out on a short Nucleosil C(18) column (5 microm, 50 x 4.6 mm i.d.) using 10 mmol/L ammonium acetate at 1.0 mL/min as mobile phase. The detector was an Applied Biosystems Sciex API 4000 mass spectrometer using atmospheric pressure chemical ionization (APCI) for ion production. The instrument was operated at unit resolution in the multiple reaction monitoring mode. The assay was linear over the range 5.00-2000 ng/mL with a limit of detection of 1.00 ng/mL. Intra- and inter-day precision were <2.82% and <2.92%, respectively, with accuracy of 93.3-106%. The assay was successfully applied to a clinical pharmacokinetic study of miglitol given as a single oral dose (50 mg) to healthy volunteers.  相似文献   

7.
A lipidomics strategy, combining high resolution reversed-phase liquid chromatography (RPLC) with high resolution quadrupole time-of-flight mass spectrometry (QqTOF), is described. The method has carefully been assessed in both a qualitative and a quantitative fashion utilizing human blood plasma. The inherent low technical variability associated with the lipidomics method allows to measure 65% of the features with an intensity RSD value below 10%. Blood plasma lipid spike-in experiments demonstrate that relative concentration differences smaller than 25% can readily be revealed by means of a t-test. Utilizing an advanced identification strategy, it is shown that the detected features mainly originate from (lyso-)phospholipids, sphingolipids, mono-, di- and triacylglycerols and cholesterol esters. The high resolution offered by the up-front RPLC step further allows to discriminate various isomeric species associated with the different lipid classes. The added value of utilizing a Jetstream electrospray ionization (ESI) source over a regular ESI source in lipidomics is for the first time demonstrated. In addition, the application of ultra high performance LC (UHPLC) up to 1200 bar to extend the peak capacity or increase productivity is discussed.  相似文献   

8.
Phenoxyacetic acids are widely used herbicides. The toxicity of phenoxyacetic acids is debated, but high-level exposure has been shown to be hepatotoxic as well as nephrotoxic in animal studies. An inter-species difference in toxic effects has been found, with dogs particularly susceptible. In this study a method using liquid chromatography/triple quadrupole mass spectrometry (LC/MS/MS) is described for the analysis of 4-chloro-2-methylphenoxyacetic acid (MCPA), and its metabolite 4-chloro-2-hydroxymethylphenoxyacetic acid (HMCPA), 2,4-dichlorophenoxyacetic acid (2,4-D), and 2,4,5-trichlorophenoxyacetic acid (2,4,5-T) in human urine. The urine samples were treated by acid hydrolysis to degrade possible conjugations. The sample preparation was performed using solid-phase extraction. Analysis was carried out using selected reaction monitoring (SRM) in the negative ion mode. Quantification of the phenoxyacetic acids was performed using [(2)H(3)]-labeled MCPA and 2,4-D as internal standards. The method was linear in the range 0.05-310 ng/mL urine and has a within-run precision of 2-5%. The between-run precision in lower concentration ranges was between 6-15% and between 2-8% in higher concentration ranges. The limit of detection was determined to 0.05 ng/mL. The metabolites in urine were found to be stable during storage at -20 degrees C. To validate the phenoxyacetic acids as biomarkers of exposure, the method was applied in a human experimental oral exposure to MCPA, 2,4-D and 2,4,5-T. Two healthy volunteers received 200 microg of each phenoxyacetic acid in a single oral dose followed by urine sampling for 72 h post-exposure. After exposure, between 90 and 101% of the dose was recovered in the urine. In the female subject, 23%, and in the male subject 17%, of MCPA was excreted as HMCPA.  相似文献   

9.
10.
Rapid, selective, and sensitive methodology for the quantification of perfluorooctanoic acid (PFOA) and perfluorooctane sulfonate (PFOS) in human plasma using packed capillary liquid chromatography coupled to electrospray ionization ion-trap mass spectrometry has been developed. Plasma proteins were precipitated using acetonitrile and the resulting supernatant was diluted 1+1 with water containing 10 mM ammonium acetate (NH4Ac) prior to injection. Sample volumes of 250 microL were loaded onto a 30 mm x 0.32 mm ID 10 microm Kromasil C18 precolumn by a carrier solution consisting of 10 mM NH4Ac in ACN/H2O (5/95, v/v) at a flow rate of 100 microL/min, providing on-line analyte enrichment and sample clean-up. Backflushed elution onto a 100 mm x 0.32 mm ID 3.5 microm Kromasil C18 analytical column was conducted using an ACN/H2O solvent gradient containing 10 mM NH4Ac. In order to improve the robustness and performance of the method, perfluoroheptanoic acid (PFHA) was used as internal standard. Separation and detection of PFOA, PFHA, and PFOS were achieved within 10 minutes. Ionization was performed in the negative mode in the m/z range 250-550. The method was validated over the concentration range 1-200 ng/mL for PFOA and over the range 5-200 ng/mL untreated plasma for PFOS, yielding correlation coefficients of 0.997 (PFOA) and 0.996 (PFOS), respectively. The within-assay (n = 6) and between-assay (n = 6) precisions were in the range 2.1-9.2 and 5.6-12%, respectively. The concentration limits of detection (cLOD) of PFOA was 0.5 ng/mL while the cLOD of PFOS was estimated to be 0.2 ng/mL in untreated plasma.  相似文献   

11.
Gatifloxacin is an advanced-generation, 8-methoxyfluoroquinolone that is active against a broad spectrum of pathogens, including antiobiotic resistant Streptococcus pneumoniae. Development of a rapid, sensitive and selective method for the determination of gatifloxacin in human plasma is essential for understanding the pharmacokinetics of the drug when administered orally or intravenously. Solid phase extraction (SPE) using Oasis HLB was used to extract gatifloxacin and the internal standard ciprofloxacin from plasma. A method based on liquid chromatography/electrospray tandem mass spectrometry (LC/ESI-MS/MS) was developed and validated to quantitate gatifloxacin in human plasma. The precursor and major product ions of the analyte were monitored on a triple quadrupole mass spectrometer with positive ion electrospray ionization (ESI) in the multiple reaction monitoring (MRM) mode. Mechanisms for the formation of collision-induced dissociation products of gatifloxacin are proposed. Linear calibration curves were generated from 10--1000 ng/mL with coefficients of determination greater than 0.99. The interday and intraday precision (%RSD) was less than 6.0% and accuracy (%error) was less than 5.4% for gatifloxacin. The limit of detection (LOD) for the method was 500 pg/mL based on a signal-to-noise ratio of 3.  相似文献   

12.
A new liquid chromatography/mass spectrometry (LC/MS) method is presented for the determination of chloramphenicol (CAP) residues in milk, eggs, chicken muscle and liver, and beef muscle and kidney. CAP is extracted from the samples with acetonitrile and defatted with hexane. The acetonitrile extracts are then evaporated, and residues are reconstituted in 10mM ammonium acetate--acetonitrile mobile phase and injected into the LC system. CAP is determined by reversed-phase chromatography using an Inertsil ODS-2 column and MS detection with negative ion electrospray ionization. Calibration curves were linear between 0.5-5.0 ng/g for all matrixes studied. The relative standard deviations for measurements by this method were generally <12%, and average recoveries ranged from 80 to 120%, depending on the matrix involved. The method detection limits of CAP ranged from 0.2 to 0.6 ng/g, which are comparable to previously reported results. The proposed method is rapid, simple, and specific, allowing a single analyst to easily prepare over 40 samples in a regular working day.  相似文献   

13.
Phenylketonuria is a common metabolic disorder disease. Those affected appear normal at birth, but without treatment they develop severe psychomotor retardation. Throughout life, they must control their blood levels of phenylalanine (Phe) and consume a diet containing adequate amounts of Phe and tyrosine (Tyr). We have developed a liquid chromatographic/mass spectrometric (LC/MS) method for the quantitative evaluation of Phe and Tyr in food samples. This method takes advantage of the good separation of LC and the selective and reliable quantification provided by MS in the electrospray ionization mode. The LC/MS method is very suitable for the determination of selected amino acids in various matrixes. It is sensitive to levels as low as about 0.30 ppm for Tyr and 0.70 ppm for Phe and robust. Nearly 100 nondietary food samples were analyzed by the developed method.  相似文献   

14.
The histamine level in tomato fruits and pastes was determined by 2 orthogonal techniques as a means of comparing accuracy. Close statistical agreement was found between assays for free histamine by capillary electrophoresis (with UV absorbance detection), and for the dansyl derivative by reversed-phase liquid chromatography (LC). Both techniques have adequate sensitivity for the analysis of endogenous histamine in tomatoes, but LC/electrospray tandem mass spectrometry was more sensitive by at least an order of magnitude, down to a level of 0.05 mg/kg.  相似文献   

15.
A rapid analytical method based on liquid chromatography/tandem mass spectrometry (LC/MS/MS) using electrospray ionization in negative ion detection mode was developed for the analysis of underivatized iodoacetic acid in water. The method was applied to model reaction mixtures in the study of the formation of iodoacetic acid after chlorinated tap water was boiled in the presence of potassium iodide or iodized table salt. Samples can be directly analyzed by the LC/MS/MS system without extraction or chemical derivatization. Limit of detection was determined to be 0.3 microg/L (or 0.3 ng/mL) and limit of quantitation was about 1 microg/L (1 ng/mL).  相似文献   

16.
17.
The presence of aristolochic acid in some dietary supplements is a concern to regulators and consumers. A method has been developed, by initially using a reference method as a guide, during single laboratory validation (SLV) for the determination of aristolochic acid I, also known as aristolochic acid A, in botanical species and dietary supplements at concentrations of approximately 2 to 32 microg/g. Higher levels were determined by dilution to fit the standard curve. Through the SLV, the method was optimized for quantification by liquid chromatography with ultraviolet detection (LC-UV) and LC/mass spectrometry (MS) confirmation. The test samples were extracted with organic solvent and water, then injected on a reverse phase LC column. Quantification was achieved with linear regression using a laboratory automation system. The SLV study included systematically optimizing the LC-UV method with regard to test sample size, fine grinding of solids, and solvent extraction efficiency. These parameters were varied in increments (and in separate optimization studies), in order to ensure that each parameter was individually studied; the test results include corresponding tables of parameter variations. In addition, the chromatographic conditions were optimized with respect to injection volume and detection wavelength. Precision studies produced overall relative standard deviation values from 2.44 up to 8.26% for aristolochic acid I. Mean recoveries were between 100 and 103% at the 2 microg/g level, between 102 and 103% at the 10 microg/g level, and 104% at the 30 microg/g level.  相似文献   

18.
Interlaboratory validation studies have been performed on 2 methods for the determination of chlormequat (CLQ) and mepiquat (MPQ). Both methods used identical extraction procedures and stable isotope internal standardization but differed in the use of liquid chromatography/mass spectrometry (LC/MS) or LC/tandem mass spectrometry (LC/MS/MS) for the determination, the amount of internal standard used, and the expected limit of detection. After addition of deuterated internal standards, CLQ and MPQ were extracted with methanol-water and determined by LC//MS or LC/MS/MS with positive electrospray ionization. Eight European laboratories participated in the LC/MS method study, analyzing mushroom, pear, wheat flour, and fruit puree with residues of CLQ in the range 0.040-1.19 mg/kg and of MPQ in the range 0.041-0.39 mg/kg. For CLQ, the Horwitz ratio (HoRat) values for individual test materials/levels were in the range 0.85-1.13 with a mean of 1.00, showing good method performance. For MPQ, the Ho values for mushroom, pear (both levels), and wheat flour were in the range 0.83-0.94, again indicating good method performance. For the determination of MPQ in infant food (fruit puree) at 0.041 mg/kg, the Ho was 1.7 when a value of 0 reported by one participant was excluded. In the LC/MS/MS study, in which 11 laboratories participated, a separate sample set was analyzed with residues of CLQ in the range 0.007-1.03 mg/kg and of MPQ in the range 0.008-0.72 mg/kg. Ho values for CLQ were in the range 0.27-1.36 and for MPQ in the range 0.51-2.10, all corresponding to acceptable method performance.  相似文献   

19.
The determination of tetra- to octachlorodibenzo-p-dioxins and tetra- to octachlorodibenzofurans (PCCD/Fs) by high-resolution gas chromatography/tandem mass spectrometry (HRGC/MS/MS) and high-resolution gas chromatography/triple mass spectrometry (HRGC/MS(3)) in a quadrupole ion trap, equipped with an external ion source, is presented. MS/MS involves a typical four-step process, namely ionization, parent ion isolation, collision-induced dissociation (CID) and mass analysis of the daughter ions. For the MS(3) experiment, the MS/MS scan function is used with the addition of selected daughter ion isolation, their CID and the mass analysis of second-generation product ions called 'grand-daughter ions.' For both methods, the energies necessary for the CID of the 17 PCDD/Fs were determined and optimized using multiple scan functions with different CID amplitudes. The CID efficiency, defined as the signal ratio of fragment ions detected from the major dissociation channels to molecular ions isolated, was 1.15-2.40 V for parent ion dissociation (MS/MS) and 1.05-1.50 V for daughter ion dissociation (MS(3)) and for all the chloro congeners. The same sensitivity (1 pg microl(-1)) can be reached with both the MS/MS and MS(3) methods and linear responses were obtained between 1 and 100 pg microl(-1) injected.  相似文献   

20.
Tripamide is a drug widely used in clinical practice for the treatment of hypertension and edema. This work evaluated a screening method for Tripamide and its urinary metabolites in human urine, using high-performance liquid chromatography diode-array detection (HPLC/DAD). Identification of these metabolites was investigated by high-performance liquid chromatography/electrospray ionization tandem mass spectrometry (HPLC/ESI-MS/MS) after dosing with 15 mg Tripamide. Acid hydrolysis showed that Tripamide is conjugated in the body. Two suspected metabolites were detected by HPLC/DAD. HPLC/ESI-MS/MS analysis suggested that these metabolites were probably hydroxylated together with loss of the -NH(2) group and dehydrogenation. These results will be useful in confirmation methods for Tripamide in doping control.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号