An ion-pair reversed-phase HPLC method was evaluated for the separation of synthetic oligonucleotides. Mass transfer in the stationary phase was found to be a major factor contributing to peak broadening on porous C18 stationary phases. A small sorbent particle size (2.5 microm), elevated temperature and a relatively slow flow-rate were utilized to enhance mass transfer. A short 50 mm column allows for an efficient separation up to 30mer oligonucleotides. The separation strategy consists of a shallow linear gradient of organic modifier, optimal initial gradient strength, and the use of an ion-pairing buffer. The triethylammonium acetate ion-pairing mobile phases have been traditionally used for oligonucleotide separations with good result. However, the oligonucleotide retention is affected by its nucleotide composition. We developed a mathematical model for the prediction of oligonucleotide retention from sequence and length. We used the model successfully to select the optimal initial gradient strength for fast HPLC purification of synthetic oligonucleotides. We also utilized ion-pairing mobile phases comprised of triethylamine (TEA) buffered by hexafluoroisopropanol (HFIP). The TEA-HFIP aqueous buffers are useful for a highly efficient and less sequence-dependent separation of heterooligonucleotides.  相似文献   

2.
Ion-interaction chromatography of Plasmocorinth B (a disulphonated azo dye) complexes of Co(III), Cu(II), Fe(III), Ga(III), In(III), Ni(II), V(V) and Zr(IV) was studied. The behaviour of two different reversed-phase C18 columns (5 and 10 μm) was compared and an on-line enrichment procedure was developed following the optimization of eluent (pH, ligand concentration, ionic strength and organic modifier). The described technique, applied to the analysis of metal ions at μg/1 levels in natural waters, gave satisfactory precision and accuracy in comparison with inductively coupled plasma atomic emission spectroscopic results.  相似文献   

3.
4.
Summary Polymeric substances formed from concentrated sodium amoxicillin in an aqueous solution have been separated using two high-performance liquid chromatographic methods. We used a C18 reversed-phase column with tetrabutylammonium chloride as an ion-pairing agent with an acetonitrile gradient and a TSKgel G2500PWxl column with water as the solvent for gel permeation chromatography. The separated materials, ranging in size from the monomer to the tetramer, have been characterized by functional-group chemical analysis, while the identification of the piperazine-2,5-dione was done using a pure standard. A greater number of peaks which were also better defined were obtained using the ion-pair reversed-phase method, and open and closed beta-lactam ring polymer forms could be distinguished. Using the gel permeation method, only a few monomer, piperazine-2,5-dione, dimer, trimer and combined amoxicillin trimer and tetramer peaks were obtained with water, although those obtained were quite well defined. The data on the time-course of formation of the oligomers and the amoxicillin degradation product were virtually identical by both methods. In some countries, particularly the UK, the name of the compound is amoxycillin.  相似文献   

5.
A small, semi-preparative C(4) RP-HPLC column was used to set up the conclusive laboratory-scale purification of Chinese hamster ovary-derived human thyrotropin (hTSH), after a preliminary concentration-purification of an extremely dilute and poorly ( approximately 0.6 microg hTSH/mL; mass fraction=0.35%) conditioned medium on a cation exchanger. Several fractions of this eluate were repeatedly injected on the semi-preparative column, obtaining, in a single run (<1h chromatographic time), a concentrated pool ( approximately 1.2 mg/mL) of highly purified hTSH that could be further concentrated to >3 mg/mL and then efficiently lyophilized. The overall recovery in the rapid RP-HPLC purification step, including concentration and lyophilization, was of the order of 80%. The final product, when tested via a precise, single-dose in vivo bioassay, confirmed that it did not suffer any loss of bioactivity. This same methodology can be easily adapted to the small-scale purification of other recombinant products, even when obtained from genetically modified organisms at extremely low concentrations and mass fractions.  相似文献   

6.
Current knowledge of stereoselective pharmacokinetics and different potencies of drug enantiomers requires the performance of stereoselective analysis during therapeutic drug monitoring in clinical practice. However, in the case of the new antidepressant drug reboxetine, no effort has been made so far to find a such a suitable system. Therefore, as a step towards developing an enantioselective bioanalytical method for reboxetine and the O-desethylreboxetine metabolite, three stereoselective chromatographic approaches have been investigated. Several chiral columns were tested, among them Chiral-AGP, ChiraGrom 2 and Chiral-CBH, which were able to simultaneously separate the two compounds into enantiomers in total running times of 28, 18 and 12 min, respectively.  相似文献   

7.
A hydrophilic interaction chromatography (HILIC) method has been developed and validated as a secondary or orthogonal method complementary to a reversed-phase HPLC (RP-HPLC) method for quantitation of a polar active pharmaceutical ingredient and its three degradation products. The HILIC method uses a diol column and a mobile phase consisting of acetonitrile/water and ammonium chloride. The compounds of interest show significant differences in retention behaviors with the two very different chromatographic systems, which are desired in developing orthogonal methods. The HILIC method is validated and has met all validation acceptance criteria for the support of drug development activities.  相似文献   

8.
9.
For the determination of beta-aminoisobutyric acid (BAIBA) in urine samples in which the beta-alanine concentrations are higher than those of BAIBA, the resolution between these two amino acids, separated by reversed-phase liquid chromatography on an octadecylsilane column, was optimized. The chromatographic analysis included precolumn derivatization of amino acids with o-phthalaldehyde, followed by a 15-min isocratic elution and detection at 340 nm. Because of its simplicity, this method should be useful for monitoring urinary excretion of BAIBA.  相似文献   

10.
11.
A rapid and sensitive high-performance liquid chromatographic technique was developed for the simultaneous determination of gentisic acid, salicyluric acid, acetylsalicylic acid and salicylic acid in plasma and serum. The method involved a single deproteinization step and separation using a reversed-phase column eluted with a buffered methanol (35%) mobile phase. Detection was achieved with a variable-wavelength ultraviolet detector set at 235 nm and a given chromatographic analysis could be completed in less than 10 min. The method was tested in both human and animal (rat) models given a single dose of acetylsalicylic acid.  相似文献   

12.
A novel mixed-mode reversed-phase and cation-exchange high-performance liquid chromatography (HPLC) method is described to simultaneously determine four related impurities of cations, zwitterions and neutral compounds in developmental Drug A. The commercial column is Primesep 200 containing hydrophobic alkyl chains with embedded acidic groups in H(+) form on a silica support. The mobile phase variables of acid additives, contents of acetonitrile and concentrations of potassium chloride have been thoroughly investigated to optimize the separation. The retention factors as a function of the concentrations of potassium chloride and the percentages of acetonitrile in the mobile phases are investigated to get an insight into the retention and separation mechanisms of each related impurity and Drug A. Furthermore, the elution orders of the related impurities and Drug A in an ion-pair chromatography (IPC) are compared to those in the mixed-mode HPLC to further understand the chromatographic retention behaviors of each related impurity and Drug A. The study found that the positively charged Degradant 1, Degradant 2 and Drug A were retained by both ion-exchange and reversed-phase partitioning mechanisms. RI2, a small ionic compound, was primarily retained by ion-exchange. RI4, a neutral compound, was retained through reversed-phase partitioning without ion-exchange. Moreover, the method performance characteristics of selectivity, sensitivity and accuracy have been demonstrated to be suitable to determine the related impurities in the capsules of Drug A.  相似文献   

13.
14.
李志东  傅青  戴卓舜  金郁  梁鑫淼 《色谱》2022,40(1):66-73
环孢素A(cyclosporine A,CsA)是由11个氨基酸组成的中性环状多肽,是临床拮抗器官和组织移植后排异反应的首选药物。高效液相色谱法广泛应用于CsA的分离分析,开展CsA色谱行为的研究是使用制备高效液相色谱纯化CsA的关键。该文首先在C18固定相上比较了CsA在甲醇-水和乙腈-水两种流动相体系中的保留行为,结果表明其保留时间对有机相比例变化比较敏感。控制甲醇比例在84%~88%,或者乙腈比例在75%~85%,CsA的保留因子(k)在3~7范围内。考察了上样量对CsA峰形的影响。随着上样量增加,在两种流动相体系中,CsA的峰形都由对称开始变得拖尾,保留时间前移。因此在进行CsA纯化时,需要特别注意前杂的去除情况。然后采用吸附等温线描述CsA的保留行为,当流动相中CsA的质量浓度较低时,有机相比例对溶质在固定相上的吸附量影响并不明显。随着溶质的质量浓度增加至0.5 g/L以上,有机相比例降低有助于提高CsA在固定相上的吸附量。和甲醇-水体系相比,在乙腈-水体系中固定相对溶质有更大的吸附容量。用模型对CsA的等温吸附曲线拟合,在甲醇-水体系中符合Langmuir模型,在乙腈-水体系中为Moreau模型。由模型参数可知在两种体系下,CsA在C18固定相上均为单层吸附,区别在于乙腈-水体系中CsA会产生较大的分子间作用力。最后,实验采用0~60 min 65%~75%乙腈、60~80 min 75%乙腈的条件开展了环孢素A纯化的探索实验,可将CsA的杂质控制在0.2%以下。本研究结果对采用制备高效液相色谱纯化CsA具有指导意义。  相似文献   

15.
The separation of peptides during RP-HPLC depends mainly upon differential hydrophobic interactions of the individual peptides being separated with the C18 group of the stationary phase. We have examined the behavior of dimeric disulfide-linked model peptides during RP-HPLC in order to study self-induced conformational effects. A set of 18 analogues of the amphipathic alpha-helical sequence Ac-LKLLKKLLKKLKKLLKKL-NH2 was used for this study. These analogues differed only by the successive replacement of each position with a cysteine. Strong peptide-peptide interactions, occurring through interchain hydrophobic forces, resulted in a presenting face to the C18 group, consisting primarily of lysine residues and, in turn, in early retention times. Three homo-dimers were also found to be strongly alpha-helical in water as determined by circular dichroism spectroscopy.  相似文献   

16.
A sensitive determination method for melatonin was developed. Melatonin was derivatized under alkaline conditions in the presence of hydrogen peroxide. The resultant fluorophore was excited at 247 nm and the emission wavelength was 384 nm. The Stokes shift was 137 nm, which was longer than that of melatonin itself (lambda ex 280 nm, lambda em 330 nm). The melatonin derivative was separated by reversed-phase HPLC in about 15 min and the calibration curve was linear from 500 amol to 5 pmol (r > 0.999) with the detection limit of 500 amol (S/N = 5). The sensitivity of this method was about ten times higher than that of previous methods. Both the day-to-day precision and within-day precision were about 5%, and the derivative of melatonin in the aqueous solution was stable for more than 10 days. This method was successfully applied to the determination of melatonin in rat pineal gland.  相似文献   

17.
Ganciclovir is a nucleoside analogue widely used in the treatment of cytomegalovirus infections, which affects mainly immunocompromised patients. Recently, new pharmaceutical dosage forms based on the use of albumin nanoparticles have been developed for improving the efficacy of this drug. The aim of this study was to develop an analytical HPLC method for the determination of ganciclovir in both pharmaceuticals (i.e. albumin nanoparticles) and biological medium samples. The chromatography was performed on a reversed-phase encapped column (LiChrospher Select B C8) with a mobile phase consisting of acetonitrile in 0.05 M ammonium acetate (pH 6.5; 2: 98, v/v). Acyclovir was used as internal standard and the detection wavelength was 254 nm. The limit of quantitation of ganciclovir was 50 ng/ml and the average recoveries over a concentration range of 0.05–10 μg/ml ranged from 98 to 102%. Precision did not exceed 5%. In summary, this assay is a selective, sensitive and reproducible method for the determination of the ganciclovir in albumin nanoparticles. It can be successfully applied to the estimation of the ganciclovir uptake by cultured human corneal fibroblasts.  相似文献   

18.
19.
A simple, rapid and reliable chemical analysis method for microcystins (cyanoginosins) has been studied. Three different mobile phases for high-performance liquid chromatography were selected and optimized. Also the adsorptive powers of three commercially available C18 cartridges were compared and the results successfully applied to the clean up of three of the toxins. Finally a total system for the analysis and isolation of microcystins was established.  相似文献   