首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 421 毫秒
1.
The effect of laser defocusing on analytical performance of laser ablation inductively coupled plasma atomic emission spectrometry (LA-ICP-AES) was studied by varying laser focus conditions with respect to the surface of a low-alloy steel and a powdered sediment pellet. Laser-induced plasma (LIP) and LA-ICP-AES emission signals and LIP excitation temperatures (LIP Tex) were determined and compared for different laser defocus conditions. LIP Fe and LA-ICP-AES Fe emission signals and LIP Tex decreased when the laser was defocused for the low-alloy steel. On the other hand, when the sediment pellet was ablated, LIP Tex decreased when the laser was defocused. However, LA-ICP-AES Fe emission signals increased at first, then decreased when the laser was defocused more. It was concluded that LIP Tex and LIP and LA-ICP-AES Fe emission signals are dependent on laser shot conditions (focus–defocus), and are also dependent on sample type (texture, mineralogy, hardness, conductivity and heat capacity).  相似文献   

2.
Potential of infrared laser ablation (LA) coupled with ICP-AES as a technique suitable for the determination of trace elements (Zn, Cu, Ni, Cr, and V) in agricultural soils was studied. Operating parameters such as laser beam energy, laser beam focusing with respect to the sample surface, and velocity of the sample translation in the plane perpendicular to the laser beam were optimized. Soil samples were mixed with powdered Ag as a binder, and an internal standard (GeO(2)), and pressed into pellets. Calibration samples were prepared by adding known amounts of oxides of elements of interest into soils of known elemental composition and then processed in the same way as the analyzed samples. Calibration curves were found to be linear at least up to several hundreds of mg kg(-1) for the elements of interest. The elemental contents obtained by using LA-ICP-AES were compared with those obtained by analysis using wet chemistry followed by ICP-AES with pneumatic nebulization (PN). The results were in good agreement. Accuracy was also tested using certified reference soils with a bias not exceeding 10% relative.  相似文献   

3.
Despite the large number of successful applications of laser ablation, elemental and isotopic fractionation coupled to inductively coupled plasma mass spectrometry (ICP-MS) remain as the main limitations for many applications of this technique in the fields of analytical chemistry and Earth Sciences. A substantial effort has been made to control such fractionations, which are well-established features of nanosecond laser ablation systems. Technological advancements made over the past decade now allow the ablation of solids by femtosecond laser pulses in the deep ultraviolet (UV) region at wavelengths less than 200 nm. Here the use of femtosecond laser ablation and its effects on elemental and isotopic fractionation is investigated. The Pb/U system is used to illustrate elemental fractionation and stable Fe isotopes are used to illustrate isotopic fractionation. No elemental fractionation is observed beyond the precision of the multiple-collector inductively coupled plasma mass spectrometry (MC-ICP-MS) measurements. Without a matrix match between standard and sample, elemental fractionation is absent even when using different laser ablation protocols for standardization and samples (spot versus raster). Furthermore, we found that laser ablation-induced isotope ratio drifts, commonly observed during nanosecond laser ablation, are undetectable during ultraviolet femtosecond laser ablation. So far the precision obtained for Fe isotope ratio determinations is 0.1‰ (2 standard deviation) for the 56Fe/54Fe ratio. This is close to that obtainable by solution multiple-collector inductively coupled plasma mass spectrometry. The accuracy of the results appears to be independent of the matrix used for standardization. The resulting smaller particle sizes reduce fractionation processes. Femtosecond laser ablation carries the potential to solve some of the difficulties encountered during the two prior decades since the introduction of laser ablation.  相似文献   

4.
A laser ablation-inductively coupled plasma-mass spectrometric (LA-ICPMS) technique utilizing a titanium-sapphire (TiS) femtosecond laser (fs-laser) has been developed for elemental and isotopic analysis. The signal intensity profile, depth of the ablation pit and level of elemental fractionation were investigated in order to evaluate the analytical capability of the present fs-laser ablation-ICPMS technique. The signal intensity profile of (57)Fe, obtained from iron sulfide (FeS(2)), demonstrated that the resulting signal intensity of (57)Fe achieved by the fs-laser ablation was almost 4-times higher than that obtained by ArF excimer laser ablation under a similar energy fluence (5 J/cm(2)). In fs-laser ablation, there is no significant difference in a depth of the ablation pit between glass and zircon material, while in ArF laser ablation, the resulting crater depth on the zircon crystal was almost half the level than that obtained for glass material. Both the thermal-induced and particle size-related elemental fractionations, which have been thought to be main sources of analytical error in the LA-ICPMS analysis, were measured on a Harvard 91500 zircon crystal. The resulting fractionation indexes on the (206)Pb/(238)U (f(Pb/U)) and (238)U/(232)Th (f(U/Th)) ratios obtained by the present fs-laser ablation system were significantly smaller than those obtained by a conventional ArF excimer laser ablation system, demonstrative of smaller elemental fractionation. Using the present fs-laser ablation technique, the time profile of the signal intensity of (56)Fe and the isotopic ratios ((57)Fe/(54)Fe and (56)Fe/(54)Fe) have been measured on a natural pyrite (FeS(2)) sample. Repeatability in signal intensity of (56)Fe achieved by the fs-laser ablation system was significantly better than that obtained by ArF excimer laser ablation. Moreover, the resulting precision in (57)Fe/(54)Fe and (56)Fe/(54)Fe ratio measurements could be improved by the fs-laser ablation system. The data obtained here clearly demonstrate that, even with the fundamental wavelength (NIR operating at 780 nm), the fs-laser ablation system has the potential to become a significant tool for in-situ elemental and isotopic analysis of geochemical samples including heavy minerals and metallic materials.  相似文献   

5.
UV laser ablation inductively coupled plasma atomic emission spectrometry (LA-ICP-AES) has been applied to the direct determination of additives in solid poly(vinyl chloride) materials. A Nd:YAG laser, operating at its fourth harmonic (266 nm), was used with a beam masking device, in the most reproducible conditions, to introduce solid particles into the plasma torch of a simultaneous ICP-AES system. Emphasis was placed on both precision and accuracy in the analysis of PVC materials by LA-ICP-AES. A series of six in-house PVC reference materials was prepared by incorporating several additives in increasing concentrations. Three alternative methods were evaluated to certify the amount of incorporated elements: ICP-AES with sample dissolution, NAA and XRF. Satisfactory results and good agreement were obtained for seven elements (Al, Ca, Cd, Mg, Sb, Sn and Ti) among the ten incorporated. Sample homogeneity appeared to be satisfactory, and calibration graphs obtained by LA-ICP-AES for several elements are presented. Finally, the performance of the technique in terms of repeatability (1.6-5%), reproducibility (2–5%), and limits of detection was investigated.  相似文献   

6.
The laser ablation (LA) method is an effective technique for quantitative analysis. In the present work, a new LA system was developed for the high-sensitivity analysis of metal materials using inductively coupled plasma mass spectrometry (ICP-MS). This system consists of a high-frequency Q-switched laser and 2 scanning mirrors for scanning the ablation spot in an adequately large area of the specimen without vacant spaces. The influence of elemental fractionation (non-stoichiometric generation of vapor species) can be eliminated by repetitive irradiation of this pattern on the same area. Particles generated with an average laser power of 0.6 W with the developed LA system gave intensity and stability substantially similar to that of a 500 microg/ml solution steel sample in solution ICP-MS. The analytical performance of the developed LA-ICP-MS was compared with that of a solution ICP-MS using NIST steel SRMs. The performance of the newly-developed system is comparable to that of conventional solution ICP-MS in both accuracy and precision. The correlation coefficients between the contents and the intensity ratios to Fe were over 0.99 for most elements. The relative standard deviation (RSD) obtained by LA-ICP-MS revealed that this system can analyze iron samples with good precision. The results of ultra trace level analysis of high-purity iron showed that developed LA-ICP-MS is capable of analyzing ppm concentration levels with a 20 - 30 ppb level standard deviation. The detection limit was on the order of 10 ppb for most elements.  相似文献   

7.
The influence of sample matrix composition, absorption behavior and laser aerosol particle size distribution on elemental fractionation in laser ablation inductively coupled plasma mass spectrometry was studied for nanosecond laser ablation at a wavelength of 266 nm. To this end, lithium tetraborate glass samples with different iron oxide contents and trace amounts of a group of 11 elements were prepared synthetically. The samples were characterized in terms of optical absorbance, melting points, trace element concentrations and homogeneity. UV/VIS spectra showed that sample absorption rises with increasing Fe2O3 content. Crater depths and time-dependent particle size distributions were measured, and ablated and transported sample volumes were estimated. Furthermore, the laser aerosol was filtered using a particle separation device and transient ICP-MS signals were acquired with and without filtering the aerosol. The results demonstrate that the amount of ablated sample is related to the absorption coefficient of the sample and therefore to the optical penetration depth of the laser beam into the sample. The higher energy densities resulting from the shorter penetration depths result in smaller average particle sizes for highly absorbing samples, which allows more efficient transport to and atomization and excitation of the ablated material within the ICP. The particle size distribution changes continuously with ablation time, and larger particle fractions occur mainly at the beginning of the ablation, which leads to particle-related fractionation processes at the beginning of the transient signal. Exceeding a critical depth to diameter ratio, laser-related elemental fractionation processes occur. Changes in the volatile to non-volatile element intensity ratio after the aerosol is filtered indicate that particle size-related enrichment processes contribute to elemental fractionation.  相似文献   

8.
A study of LA-ICP-MS analysis of pressed powdered tungsten carbide precursors was performed to show the advantages and problems of nanosecond laser ablation of matrix-unified samples. Five samples with different compositions were pressed into pellets both with silver powder as a binder serving to keep the matrix unified, and without any binder. The laser ablation was performed by nanosecond Nd:YAG laser working at 213 nm.The particle formation during ablation of both sets of pellets was studied using an optical aerosol spectrometer allowing the measurement of particle concentration in two size ranges (10-250 nm and 0.25-17 μm) and particle size distribution in the range of 0.25-17 μm. Additionally, the structure of the laser-generated particles was studied after their collection on a filter using a scanning electron microscope (SEM) and the particle chemical composition was determined by an energy dispersive X-ray spectroscope (EDS).The matrix effect was proved to be reduced using the same silver powdered binder for pellet preparation in the case of the laser ablation of powdered materials.The LA-ICP-MS signal dependence on the element content present in the material showed an improved correlation for Co, Ti, Ta and Nb of the matrix-unified samples compared to the non-matrix-unified pellets. In the case of W, the ICP-MS signal of matrix-unified pellets was influenced by the changes in the particle formation.  相似文献   

9.
采用自制的大气压下介质阻挡放电装置串联在激光剥蚀池与ICP炬管之间, 对激光剥蚀产生的气溶胶进行预电离. 结果表明, 元素瞬时信号轮廓的平滑度得以改善, 元素分析信号精密度(RSD, n=3)可提高2.55%. 在ArF准分子激光(193 nm)和Nd∶YAG 固体激光(213 nm)两种不同波长的激光剥蚀系统中, 元素分馏因子均比常规模式下更接近于1, 表明采用介质阻挡放电对气溶胶预电离后元素分馏效应得以有效抑制. 相比两种不同波长的激光剥蚀系统, 介质阻挡放电对213 nm固体激光的元素分馏效应改善作用明显.  相似文献   

10.
In laser ablation inductively coupled plasma mass spectrometry (LA-ICPMS), the properties of laser-generated aerosols, such as size and composition, are crucial for matrix-independent quantification. In this study, the aerosol particle morphology and elemental composition generated by two state-of-the-art laser systems (ArF excimer nanosecond-UV laser and Ti:sapphire femtosecond-IR laser) were investigated by electron microscopic techniques. Electrostatic sampling of the aerosols directly onto transmission electron microscopy (TEM) grids allowed us to study the morphology and elemental composition of the aerosols using TEM and TEM–EDX (energy dispersive X-ray spectroscopy) analyses, respectively. The results of the electron microscopic studies were finally compared to the LA-ICPMS signals of the main matrix components. The investigations were carried out for non-conducting materials (glass and zircon), metallic samples (steel and brass) and semiconductors (sulfides). The studies confirm that ns-LA-generated aerosols dominantly consist of nanoparticle agglomerates while conducting samples additionally contain larger spherical particles (diameter typically 50 to 500 nm). In contrast to ns-laser ablation, fs-LA-generated aerosols consist of a mixture of spherical particles and nanoparticle agglomerates for all investigated samples. Surprisingly, the differences in elemental composition between nanoparticle agglomerates and spherical particles produced with fs-LA were much more pronounced than in the case of ns-LA, especially for zircon (Si/Zr fractionation) and brass (Cu/Zn fractionation). These observations indicate different ablation and particle formation mechanisms for ns- and fs-LA. The particle growth mechanism for ns-LA is most likely a gas-to-particle conversion followed by agglomeration and additional hydrodynamic sputtering for conducting samples. On the other hand, phase explosion is assumed to be responsible for the mixture of large spherical particles and nanoparticle agglomerates as found for fs-LA-generated aerosols. Based on these mechanisms, the overall temporal elemental fractionation effects in ns-LA-ICPMS seem to occur mainly during the ablation. This effect was not observed for fs-LA-ICPMS despite the element separation into different particle fractions, which, on the other hand, could induce severe ICP-induced fractionation.  相似文献   

11.
The large surface area of barks from many tree species enables the effective accumulation of pollutants. Therefore, the analysis of bark material will provide useful information about the degree of pollution of a certain region. The determination of main, minor, and trace elements (Al, Ca, Cd, Ce, Cr, Cu, Fe, Mn, P, Pb, S, Ti and Zn) in bark was performed with an Nd:YAG laser coupled to an ICP-MS system. Bark standards for the calibration by laser ablation ICP-MS were prepared from different bark layers which differ for some relevant elements in concentrations. Four digestion procedures for the decomposition of the standard pellets, the numbers of laser shots per sample and of samples per region necessary have been investigated. Representative results were obtained for 5 or more samples taken from different individuals of one species of a sampling area and the averaged element concentrations of 10 separately placed laser shots for each sample. Laser ablation ICP-MS was applied for the characterization of real bark samples from different regions with high and low pollution burden. It was shown that the method is well suited to characterize different degrees of environmental impact. Anthropogenic sources were responsible for the higher concentrations of most of the elements under investigation.  相似文献   

12.
This report details the application of laser ablation quadrupole ICP-MS for the (multi)elemental mapping of 100-μm-thick sections of rat brain. The laser spot size used was 60 μm, and the laser scan speed was 120 μm s−1. The analysis was relatively rapid, allowing mapping of a whole brain thin section (≈1 cm2) in about 2 h. Furthermore, the method was amenable to multi-element data collection including the physiologically important elements P and S and afforded sub μg g−1 detection limits for the important trace elements Cu and Zn. Calibrations were performed with pressed pellets of biological certified reference materials, and the elemental distributions and concentrations of Cu, Zn, and Fe were determined in whole rat brain sections. The distributions and concentration ranges for these elements were consistent with previous studies and demonstrate the utility of this technique for rapid mapping of brain thin sections.  相似文献   

13.
The large surface area of barks from many tree species enables the effective accumulation of pollutants. Therefore, the analysis of bark material will provide useful information about the degree of pollution of a certain region. The determination of main, minor, and trace elements (Al, Ca, Cd, Ce, Cr, Cu, Fe, Mn, P, Pb, S, Ti and Zn) in bark was performed with an Nd:YAG laser coupled to an ICP-MS system. Bark standards for the calibration by laser ablation ICP-MS were prepared from different bark layers which differ for some relevant elements in concentrations. Four digestion procedures for the decomposition of the standard pellets, the numbers of laser shots per sample and of samples per region necessary have been investigated. Representative results were obtained for 5 or more samples taken from different individuals of one species of a sampling area and the averaged element concentrations of 10 separately placed laser shots for each sample. Laser ablation ICP-MS was applied for the characterization of real bark samples from different regions with high and low pollution burden. It was shown that the method is well suited to characterize different degrees of environmental impact. Anthropogenic sources were responsible for the higher concentrations of most of the elements under investigation. Received: 26 April 1999 / Revised: 24 August 1999 / /Accepted: 28 August 1999  相似文献   

14.
A novel laser ablation and ionization time-of-flight mass spectrometer has been used for direct elemental analysis of alloys. The system was incorporated with an ion guide cooling cell to reduce the kinetic energy distribution for the purpose of better resolution. Parametric studies have been conducted on the system with respect to the buffer gas pressure and the distance from sample to the nozzle to obtain the maximal signal intensities. In order to obtain satisfactory relative sensitivity coefficients (RSC) for different elements, the influence of the laser irradiance, nozzle voltage, rf frequency and voltage of the hexapole were also investigated. Under the optimized conditions, the RSC of different elements were available for direct semi-quantitative analysis. The mass resolving power (FWHM) of the spectrometer was approximately 7000 (m/Δm) and the limit of detection (LOD) was 10− 6 g/g.  相似文献   

15.
Laser ablation in analytical chemistry-a review   总被引:4,自引:0,他引:4  
Russo RE  Mao X  Liu H  Gonzalez J  Mao SS 《Talanta》2002,57(3):425-451
Laser ablation is becoming a dominant technology for direct solid sampling in analytical chemistry. Laser ablation refers to the process in which an intense burst of energy delivered by a short laser pulse is used to sample (remove a portion of) a material. The advantages of laser ablation chemical analysis include direct characterization of solids, no chemical procedures for dissolution, reduced risk of contamination or sample loss, analysis of very small samples not separable for solution analysis, and determination of spatial distributions of elemental composition. This review describes recent research to understand and utilize laser ablation for direct solid sampling, with emphasis on sample introduction to an inductively coupled plasma (ICP). Current research related to contemporary experimental systems, calibration and optimization, and fractionation is discussed, with a summary of applications in several areas.  相似文献   

16.
H Yasuhara  T Okano  Y Matsumura 《The Analyst》1992,117(3):395-399
A rapid quantitative analysis of the trace elements in steel by laser ablation inductively coupled plasma mass spectrometry is described. The conditions for laser ablation and normalization methods to improve the analytical precision are given. The optimum conditions for laser ablation were achieved when the ion yield was a maximum at the focus position in the fixed Q pulse mode, and above the focus position in the Q-switched pulse mode. It was found that the fixed Q pulse mode was most suitable for the determination of trace metal elements in steel, and that the Q-switched pulse mode was most suitable for both non-metallic elements and elements with a high boiling-point. In order to improve the analytical precision for those elements with a strong background intensity, normalization methods with both the matrix ion, 57Fe+, and 38Ar+ are proposed.  相似文献   

17.
The spectroscopic line emissions of copper and zinc from atomized particles generated by orthogonal pre-pulse laser ablation of brass and transported from the ablation cell through tubes into an ICP have been simultaneously measured end-on with fast photomultipliers. It was shown that simultaneous line monitoring of major elements provides not only information on the aerosol transport in laser ablation ICP-spectrometry, but also on the ratios of small to single larger particles and their respective elemental compositions and, therefore, on possible elemental fractionation problems. Furthermore, the spectroscopic information can be easily exploited for proper adjustment of the laser fluence in order to minimize the production of large particles, to improve the transport efficiency and to reduce the noise of analytical signals in laser ablation ICP-spectrometry. The present particular experiment on orthogonal pre-pulse laser ablation of brass confirms the recent finding that such kind of double-pulse arrangement produces predominantly ultra-fine particles. Individual brass particles with diameters ≳ 250 nm could be analyzed. They showed large Zn depletions as expected. Finally, strong accumulations of aerosol particles were found in the ablation cell used even at low laser pulse frequencies.  相似文献   

18.
Coedo AG  Padilla I  Dorado MT 《Talanta》2005,67(1):136-143
Element determination in solid waste products from the steel industry usually involves the time-consuming step of preparing a solution of the solid. Laser ablation (LA) inductively coupled plasma mass spectrometry (ICP-MS) has been applied to the analysis of Cr, Ni, Cu, As, Cd and Sn, elements of importance from the point of view of their impact on the environment, in electric arc furnace flue dust (EAFD). A simple method of sample preparation as pressed pellets using a mixture of cellulose and paraffin as binder material was applied. Calibration standards were prepared spiking multielement solution standards to a 1:1 ZnO + Fe2O3 synthetic matrix. The wet powder was dried and mechanically homogenised. Quantitative analysis were based on external calibration using a set of matrix matched calibration standards with Rh as a internal standard. Results obtained using only one-point for calibration without matrix matched, needing less time for standardization and data processing, are also presented. Data are calculated for flue dust reference materials: CRM 876-1 (EAFD), AG-6203 (EAFD), AG-6201 (cupola dust) and AG-SX3705 (coke ashes), and for two representative electrical arc furnace flue dusts samples from Spanish steelmaking companies: MS-1 and MS-2. For the reference materials, an acceptable agreement with certificate values was achieved, and the results for the MS samples matched with those obtained from conventional nebulization solutions (CN). The analytical precision was found to be better than 7% R.S.D. both within a single pellet and between several pellets of the same sample for all the elements.  相似文献   

19.
In this study we developed a dried-droplet method for laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS). The proposed method provides accurate and precise results when building calibration curves and determining elements of interest in real liquid samples. After placing just 1 μL of a liquid standard solution or a real sample onto the filter surface and then converting the solution into a very small, thin dry spot, the sample could be applied as an analytical subject for LA. To demonstrate the feasibility of this proposed method, we used LA-ICP-MS and conventional ICP-MS to determine the levels of 13 elements (Li, V, Mn, Co, Ni, Cu, Zn, As, Mo, Cd, Sb, Tl, and Pb) in five water samples. The correlation coefficients obtained from the various calibration curves ranged from 0.9920 (205Tl) to 0.9998 (51V), sufficient to allow the determination of a wide range of elements in the samples. We also investigated the effects of Methylene Blue (MB) and the NaCl concentration on the elemental analyses. MB could be used as an indicator during the ablation process; its presence in the samples only negligibly influenced the intensities of the signals of most of the tested elements. Notably, high NaCl contents led to signal suppression for some of the elements. In comparison with the established sample introduction by nebulization, our developed technique abrogates the need for time-consuming sample preparation and reduces the possibility of sample contamination.  相似文献   

20.
硫化物矿物LA-ICP-MS激光剥蚀元素信号响应   总被引:3,自引:0,他引:3  
采用193 nm ArF准分子激光剥蚀电感耦合等离子体质谱(LA-ICP-MS)对5种天然硫化物矿物进行激光剥蚀分析, 基于不同硫化物矿物的剥蚀形貌特征和元素瞬时信号响应, 考察了硫化物矿物的元素分馏效应及激光频率、能量和激光斑径对硫化物矿物激光剥蚀行为的影响. 结果表明, 不同硫化物矿物的激光剥蚀形貌和元素分馏效应存在明显差异, 其中黄铁矿、辉钼矿和闪锌矿的剥蚀晕约为剥蚀斑径的10倍, 而黄铜矿和磁黄铁矿的剥蚀晕约为剥蚀斑径的14倍; 黄铜矿、磁黄铁矿和闪锌矿元素分馏因子(EFI)约为1.0, 其元素分馏效应可以忽略, 而黄铁矿和辉钼矿存在明显的元素分馏效应. 在对硫化物矿物的LA-ICP-MS分析中, 选择较大的激光剥蚀斑径、较小的激光剥蚀频率与激光能量可获得理想的信号强度和准确的分析结果.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号